INSTALLATION SPECIFICATION DIGITAL TO FINE/COURSE XYZ SYNCHRO MODEL, ADC-600, P/N

Similar documents
DESIGN SPECIFICATION AIR DATA ADAPTER UNIT P/N

DESIGN SPECIFICATION # R1 Model AHRS-500 P/N ARINC 407 TO ARINC 429 ADAPTOR CTRL # /17/96

DESIGN SPECIFICATION Model LRN-500, P/N DIGITAL TO ANALOG ADAPTOR

EQUIPMENT INSTALLATION MANUAL. for the GDC66 FUEL QUANTITY ADAPTER UNIT P/N Rev B

EQUIPMENT INSTALLATION MANUAL. for the GDC59 CONVERTER P/N

EQUIPMENT INSTALLATION MANUAL. for the ARINC ALTITUDE ALERTER INTERFACE P/N

Installation Manual and Operating Instructions. Model MD32 Series Remote Magnetometer

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS. TI1200-( ) Series Static Electrical Power Inverter

EQUIPMENT INSTALLATION MANUAL. for the GFD11 COCKPIT CONTROL UNIT

ETM RECORDER P/N:

Installation Manual and Operating Instructions

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS. TI500-( ) Series Static Electrical Power Inverter

Installation Manual and Operating Instructions

Installation Manual and Operating Instructions

Installation Manual and Operating Instructions

Installation and Operation Manual. Quiet Power Dual USB Charger. QP100 Series

P/N ( )

Indian Technical Standard Order

SG102 AHRS. See what s next

E105 1/2-ATR Short Fan cooled VME Enclosure

EQUIPMENT INSTALLATION MANUAL, GDC64, TABLET AIRCRAFT INTERFACE UNIT Rev C

SYNCHRO HEADING INPUT TO A-429 CONVERTER

T1203 DME, ATC, LRA DISCRETE FUNCTION INTERFACE UNIT

uavionix and Ping are registered trademarks of uavionix Corporation and may not be used without express permission of uavionix.

Enhanced Mini-Chansim Model VCS-232

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS Series Electric Attitude Indicator

PRODUCT SPECIFICATION

H-series (Rectifier Module)

FLEX Ex Spring Clamp Terminal Base

PRODUCT SPECIFICATION

MSR 2400R. Rugged Power System for Military and Heavy Duty Applications

Line Impedance Stabilization Network (LISN)

Installation and Operation Manual. Model 251 Passenger Speaker Amplifier

LFWLP350 SERIES 350 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.00

skybeacon TM STC Installation Manual

TM3DI16G module TM3-16 inputs spring

Junos WebApp Secure 5.0 Hardware Guide

General information Engineering with Programming package. Display with display

LFWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 90% at 90V AC)

INSTRUCTION MANUAL HIGH CURRENT DRIVER BOARD STAND ALONE

Technical Manual RosenView LX

AIS-380 DC Fuel Flow Adapter P/N:

PRODUCT DESCRIPTION. Vertically cooled 2RU rectifiers with wide range of output modules available.

TM3DI16 module TM3-16 inputs

LFMWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00

TF501, TF521 Terminal Bases

DMP-200 Digital Media Player Installation Manual

DPS SERIES DC POWER SUPPLIES

NI REM Remote I/O Overview DATASHEET. Analog Output Module for Remote I/O

OCT 17 Rev A

TM3TI4 module TM3-4 inputs temperature

X SERIES X SERIES. Single-Phase Rectifier Module SINGLE-PHASE RECTIFIER MODULE. Overview

Universal Power Supplies

FEATURES DESCRIPTION FEATURES

Microair Avionics Pty Ltd Airport Drive Bundaberg Queensland 4670 Australia Tel: Fax:

NI PXIe-1062Q Power Supply Shuttle

INSTRUCTION SHEET. Eaton Logic Controller ELCB Controllers

TU531, TU532 Terminal Unit

General information. Display. Supply voltage. Input current. Encoder supply. Output current. Power loss. Memory

CM-4004F0-AERO-ITAP series Cloudberry 4 Port Airborne Gigabit Ethernet Inline Tap

LOGIC Component Technology DEFINED LOGIC LOGIC & INTERFACE Defined Logic Overview Data Sheet: DS-DL-13

Megabit Modem MM300S INSTALLATION GUIDE

FDCCM1-MM-L & FDCCM1-MM-R

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

ATR012-HEX-3U. 1/2 ATR Chassis, Sealed w/heat Exchange KEY FEATURES

NI PXI-1042 Series Power Supply Shuttle

Test and Measurements Automated Systems Component Device Testing Semiconductor Processing & Burn-in Aerospace & Satellite Testing

Microair Avionics Pty Ltd Airport Drive Bundaberg Queensland 4670 Australia Tel: Fax:

RT12-240V/2.4kW Rectifier Specification

60 Watt Medical (MWLT)

Electrical Specifications. Input Current 115 VAC: 1 A max. 230 VAC: 0.5 A max.

COCKPIT DOOR SURVEILLANCE SYSTEM - DESCRIPTION AND OPERATION

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

NI PXI-1042 POWER SUPPLY SHUTTLE USER GUIDE

(877) CPCI-3U Series. Input Voltage Range AC Input. Input Voltage Range 48VDC Input. Input Voltage Range 24/28VDC Input

DI572 Digital Input Module

VSI200E Vertical Speed Indicator with Altitude Encoder

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

General Specifications. P2-8AD4DA-2 Analog Input/Output

Model volt to 24 volt DC to DC Converter. Table of Contents. Introduction. 2. Specifications.. 2. Operation... 2

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

Features. Line Regulation. Load Regulation. Safety. Cooling. Input Connectors. Output Connectors. Overvoltage Protection. Over Temperature Protection

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

DI561 Digital Input Module

(877) CPCI-6U Series. Input Voltage Range AC Input. Input Voltage Range 48VDC Input. Input Voltage Range 24/28VDC Input

Output Voltage* (nom.)(adjustable)

PFC Mini TM Power Factor Corrected AC-DC Switchers

*Approved by CSA for non-hazardous locations (Group Safety Publication IEC Third Edition).

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

4 x 2 x 0.75 Inches Form factor. 180 Watts with Forced Air Cooling. Approved to EN/IEC Efficiencies up to 92% Standby Power < 0.

Marine User Guide. USBT202 Series High Power USB Charging Port

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

Aug04 Rev D EC

L200 LINE/SUM/MIKE AMPLIFIER OPERATING AND MAINTENANCE MANUAL

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 95% at 85V AC)

NI REM Remote I/O Overview DATASHEET. Digital Input Module for Remote I/O

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

Installation Manual AIS 200B-35

CMSA-100 Manual. Cinema Media Server Automation

Transcription:

INSTALLATION SPECIFICATION DIGITAL TO FINE/COURSE XYZ SYNCHRO SKYLIGHT AVIONICS 38629 6th St. East Palmdale, Ca. 93550 (661) 265-0497

TABLE OF CONTENTS REFERENCE SECTION PAGE (i) OPERATING INSTRUCTIONS 1 (ii) EQUIPMENT LIMITATIONS 1 (iii) INSTALLATION PROCEDURES & LIMITATIONS 2 (iv) INSTALLATION MECHANICAL DIAGRAMS 3 (v) INSTALLATION WIRING DIAGRAMS 4 (vi) SPECIFICATIONS 5 (vii) MAJOR COMPONENTS 6 (viii) ENVIRONMENTAL QUALIFICATION FORM 8 ILLUSTRATIONS REFERENCE TITLE PAGE (iv-1) MECHNICAL INSTALLATION DRAWING 3 (v-1) ELECTRICAL PINOUT DRAWING 4 (vii-1) INTERCONNECT BLOCK DIAGRAM 6, 7 i

(i) OPERATING INSTRUCTIONS The ADC-600 Adapter, by it's design has only one operating control. The unit is design with a discrete select input, enabling the operator to select the ADC source of the ARINC-429 input. This is accomplished with an externally mounted switch. The ADC-600 will not switch to an invalid source if valid data is available. Strapping of the installation allows choice of either Label 203 or 204 from the input to be decoded. Operating instructions of the systems that are interconnected need to be followed. The ADC-600 should appear transparent to the systems connected. The ADC-600 Adapter, is limited to accepting (2) ARINC-429 Digital ADC s, selectable for source and converting the data as required. In normal operation the unit will monitor both inputs for valid data and present a low valid output for the status of each and a low level to signify the system being used. The unit will use the # 1 Input for data collection as the primary unless the data becomes invalid or the operator has selected the alternate input. In the event of the primary input becoming invalid the unit will switch to the secondary input if it is valid and lite # 2 ADC. The unit will function in reverse order if the operator has selected the alternate input. In the event the selected input fails the unit will return to the primary input. (ii) EQUIPMENT LIMITATIONS The adapter is limited to converting the digital output of the new digital ADC s to ARINC- 565 Fine / Coarse Synchro altitude and a Manchester encoded digital format. The ADC-600 Adapter, as an integral component of the on board Air Data System, the update speed and accuracy is directly limited to the output driving the unit. In effect, it is a component of that system and therefore subjected to all inherent limitations of that system. A hardware design assurance of "Level D" per RTCA DO-254 Design Assurance Guidance for Airborne Electronic Hardware will be applied to design verification, documentation and manufacturing. Failure Condition Classification Minor Failure Condition Description Failure conditions that would not significantly reduce aircraft safety, and which would involve flight crew actions that are will within their capabilities. Minor failure conditions may include: a slight reduction in safety margins or functional capabilities, a slight increase in flight crew workload, such as routine flight plan changes, or inconvenience to occupants. Hardware Design Assurance Level Definition D Hardware functions whose failure or anomalous behavior, as shown by the hardware safety assessment, would cause a failure of system function resulting in a minor failure condition for the aircraft" The conditions and test required for TSO approval of this article are minimum performance standards. It is the responsibility of those desiring to install this article either on or within a specific type or class of aircraft to determine that the aircraft installation conditions are within the TSO standards. If not within the TSO standards, the article may be installed only if further evaluation by the applicant documents an acceptable installation and is approved by the administrator. The ADC-600 is classified as "ON CONDITION" with no preventative maintenance required. No overhaul time limitations apply. No scheduled inspections to determine operational status are required. In the event of a failure the operator or cognizant maintenance facility shall remove the appliance and return it to Skylight Avionics for the repair or replacement. 1

(iii) INSTALLATION PROCEDURES 1. INTRODUCTION This section contains information relative to the installation of the, ADC-600 Adapter, to assure satisfactory performance of the unit. (See Sections "iv" and "v" for detailed mechanical and wiring diagrams.) 2. UNPACKING AND INSPECTING EQUIPMENT After unpacking the unit, make a visual inspection of the unit for evidence of damage incurred during shipment. If a claim for damage is to be made, save the shipping container to substantiate the claim. 3. PREINSTALLATION CHECK Perform a continuity and power check on the wiring harness before connecting equipment. 4. POWER REQUIREMENTS The ADC-600 operates from a standard 27.5 Volt DC aircraft power source, and 26 VAC 400 HZ reference. Provide circuit protection with an in line 1 AMP breaker on the 27.5 VDC. 5. POST INSTALLATION CHECK There is no in-aircraft adjustment required for the ADC-600. All alignment and adjustment procedures are accomplished during bench maintenance. 6. PREFLIGHT CHECK Following the manufactures check out procedures of the on board Instruments, verify that the Indications being driven by the ADC-600 are accurate. 2

(iv) INSTALLATION MECHANICAL DIAGRAMS The ADC-600 is designed for flat mounting anywhere on board the aircraft, pressurized or non-pressurized compartments. The unit has four (4) mounting holes for number (6) size screws. (NOTE: Screws and other miscellaneous mounting hardware are NOT included with the ADC-600. Mechanical Drawing of ADC-600 J1 3.6500 1.7500 6.980 7.3300 0.7500 Unit Connector - DB-37P with Screw lock Retainers Mate - DB-37S MECHNICAL INSTALLATION DRAWING ILLUSTRATION (iv-1) 3

(v) INSTALLATION WIRING DIAGRAMS ADC-600 P/N 99100003 FLAG ADC # 1 ADC # 2 ADC # 2 FAIL ADC # 1 FAIL FINE Y X Z SHIELD COURSE Y X Z SHIELD MANC HI MANC LO SHIELD 429A 429B SHIELD 1 3 4 5 6 26 27 28 25 22 23 24 21 31 30 32 16 15 14 28V = Valid (Inuse ADC Valid, and 26VAC must be valid) Gnd = #1 Inuse (ADC #1 selected, #1 Valid) ADC # 2 Valid = Gnd ADC # 1 Valid = Gnd or (ADC#2 selected but invalid, #1 Valid), or (ADC#1 selected both ADC's invalid), Gnd = #2 Inuse (ADC #2 selected, #2 Valid) or (ADC#1 selected but invalid, #2 Valid), or (ADC#2 selected both ADC's invalid), ARINC-565 SYNCHRO ANALOG ALTITUDE ALTITUDE PRE-SELECTOR OR FLIGHT DATA RECORDER MANCHESTER ALTITUDE COLLINS ADC-80 SYSTEMS # 1 DIGITAL ADC ARINC 429 LABEL 204 OR 203 429A 19 429B 18 SHIELD 17 ADC Sel 12 Label Sel 13 Sel Com Gnd 11 28VDC Input Power Ground 26VAC Ref Hi 26VAC Ref Lo Chassis Gnd 36 35 9 8 33 Open = #1 ADC, Gnd = #2 ADC Open = Label 204, Gnd = Label 203 SEL COMM # 2 DIGITAL ADC ARINC 429 LABEL 204 OR 203 1a 28 VDC ESSENTIAL BUS 28 VDC RETURN 400Hz 26 VAC INSTURMENTATION BUS NOTE 1 400Hz 26 VAC RETURN AIRFRAME NOTE1, The 26 VAC REF is isolated and may require inverting on some installations. ILLUSTRATION (v-1) ELECTRICAL PINOUT DRAWING 4

(vi.) SPECIFICATIONS SPECIFICATION Compliance RTCA/DO-160D CHARACTERISTICS TSO C106 (Application Package) A1D2/B/A/B/S2BM/X/X/X/X/X/X/Z/A/A/A/Z/VVV/M/XXC3/X/X/A Physical Dimensions Height 3.650" Length 7.330" Width 1.750" Weight 1.5lb Temperature Range Operational -55 C to +70 C Storage -55 C to +85 C Altitude Power Requirements 50,000' 28 VDC @.8 AMP Peak.3 AMP Normal 26 VAC @.1 AMP Reference only Inputs 99100003 (2) ARINC 429 RECEIVERS, Labels 203 & 204. (2) SELECT INPUT (Discrete Ground) 99100003-1 (2) ARINC 419 RECEIVERS, Labels 203 & 204. (2) SELECT INPUT (Discrete Ground) ARINC-565Output COLINS ADC-80 Output Discrete output (5) FINE / COARSE SYNCHRO ALTITUDE Fine = 360 DEG / 5000 Ft. +/-.1 Degree Coarse = 360 Deg * 375 Ft. +/-.1 Degree MANCHESTER ENCODED ALTITUDE Label 09 (2) VALID INDICATORS, LOW LEVEL (2) SOURCE INDICATORS, LOW LEVEL (1) SYSTEM VALID, 28 VDC Limitations Limited to the manufactures specifications of the digital input bus and to the specifications listed herein. 5

(vii.) EQUIPMENT SYSTEMS MAJOR COMPONENT Equipment Supplied: 1ea Model ADC-600, Part Number 99100003 Equipment Required But Not Supplied: 4ea. #6 Mounting Screws Connector: Standard DB37S, with Retention Screws. Wiring Harness Interconnect cable 540-25100-001 Altitude Pre-Selector / IDC 27050-01-01 Air Data Unit / Meggitt 28010-00-01 Encoding Altimeter / Meggitt # 1 ADC ARINC 429 Bus Label 203 & 204 # 2 ADC ARINC 429 Bus Label 203 & 204 SELECT 1/2 Label Select ADC-600, P/N 99100003 DIGITAL TO FINE/COURSE XYZ SYNCHRO ALTITUDE ALTITUDE FINE/COURSE SYNCHRO PRE-SELECTOR OR FLIGHT DATA RECORDER MANCHESTER ENCODED ALTITUDE, LABEL 09 PRE-SELECTOR INPUT FOR COLLINS ADC-80 SYSTEMS ILLUSTRATION (vii-1) 6

(vii.) EQUIPMENT SYSTEMS MAJOR COMPONENT ILLUSTRATION (vii-2) INTERCONNECT BLOCK DIAGRAM 7

iii. ENVIRONMENTAL QUALIFICATION FORM NOMENCLATURE: DIGITAL TO SYNCHRO ADAPTER TYPE / MODEL / PART NO: ADC-600, P/N 99100003 MANUFACTURE S SPECIFICATI0N; MANUFACTURE: SKYLIGHT AVIONICS ADDRESS: 38629 6 th STREET EAST PALMDALE, CA. 93550-3717 RTCA/DO-160D, Dated July 29, 1997 Conditions Section Description of Conducted Tests Temperature and Altitude 4.0 Equipment tested to Category A1/D2 Auxiliary air cooling not required. Temperature Variation 5.0 Equipment tested to Category B Humidity 6.0 Equipment tested to Category A Operational Shock and 7.0 Equipment tested to Category B Crash Safety Vibration 8.0 Equipment tested to Category S, Zone 2, Curves B & M Explosion 9.0 Category X no test required Waterproofness 10.0 Category X no test required Fluids Susceptibility 11.0 Category X no test required Sand and Dust 12.0 Category X no test required Fungus 13.0 Category X no test required Salt Spray 14.0 Category X no test required Magnetic Effect 15.0 Equipment tested to Category Z Power Input 16.0 Equipment tested to Category A Voltage Spike 17.0 Equipment tested to Category A Audio Frequency 18.0 Equipment tested to Category A Susceptibility Induced Signal 19.0 Equipment tested to Category Z Susceptibility Radio Frequency 20.0 Equipment tested to Category VVV Susceptibility Radio Frequency 21.0 Equipment tested to Category M Emission Lightning Induced 22.0 Equipment tested to Category XXC3 Transient Susceptibility Lightning Direct Effects 23.0 Category X no test required Icing 24.0 Category X no test required Electrostatic Discharge 25.0 Equipment tested to Category A SECTIONS 4 THUR 8 ENVIROMENT ASSOCIATES, INC. TEST REPORT # 9604 VARIEL AVENUE 20702-1013365 CHATSWORTH, CALIFORNIA 91311 SECTIONS 16 THUR 25 NEMKO-EESI TEST REPORT # 9604 VARIEL AVENUE 21-231 CHATSWORTH, CALIFORNIA 91311 8