AMBIFLEX MF626 - USER GUIDE

Similar documents
Ambiflex MF820 OPERATOR S MANUAL

Model: Available in : Sapphire Black and Glacier White

16 Amp 1 Channel Multi Purpose Programmer User Instructions

Model: Available in : Sapphire Black and Glacier White

BACVIEW MANUAL Software Version 3.06 INSTALLATION AND OPERATION MANUAL

Table of Contents. Model: -hw. -hw. Series. Available in : Sapphire Black and Glacier White. Product Image. 16 Table of Contents

RVL470. Heating controller. G2522en. Installation Instructions. 1 Installation. 2 Commissioning Wall mounting DIN rail mounting

Model: Touchpad (TFT) Model: TFT

FCU-4 FAN COIL CONTROLLER

Temperature control unit

FP735Si Electronic 3-Channel Full Programmer for Heating and Hot Water with Service Interval Timer. Installation Guide MAKING MODERN LIVING POSSIBLE

ScottishPower Connect. User Guide

RWB29 Programmer. Daily Programming

RAMSES D GB F NL. Installation and operating instructions Room thermostat. RAMSES 832 top2

FCU-4 FAN COIL CONTROLLER

BLDA-1 & 2 Water Leak Detection Manual. CMR Electrical Ltd Bolton House Five Chimneys Lane Hadlow Down East Sussex TN22 4DX Tel:

Touchpad User Guide. National Sales. Product Support. Freecall: Ph:

Heatmiser MC Operating Instructions

CS2000 Automatic control V3 Quick Guide

DESIGO PX PXM20 / PXM20-E operator unit User's guide. Version 2.2 and later. Building Technologies

BUP2 5/2 12/4/07 12:49 AM Page 1. Introduction

Simplified Operating Instructions T105-C / T108-C / T106-C / T17B-C DISPLAYS DAY OR DAY BLOCK PROG 00:0000 PROG PROG ALWAYS OFF

D GB F NL I E P. Overview per day of the programmed switching. Channel statuses are displayed ON / OFF

A quick look at the operations of the Matrix Programmable Controller by

REMOTE CONTROLLER CS244-R OWNER S MANUAL

Brivis Touch. Owner s Manual

CP-EX252N/CP-EX302N/CP-EW302N

OPERATION MANUAL. Room thermostat EKRTW

Livezi Central. 4 speed fan Control System. Operating Instructions

Operating instructions for RAMSES 811 top2_812 top2 and RAMSES 831 top2_832 top2

Weekday / weekend room temperature controller

Model FP700 Owner s Instructions

Operation 6035 ENGLISH PROG MENU

Dryer. M720 Programming and Operation Manual. July 15, 2015 Revision 1.51

Home Screen...4. Quick Start Guide...5. MyAir Standalone Zone Controls only...5. MyAir Zone Controls With Integrated Unit On/Off Control...

OPERATION MANUAL. Remote controller BRC1D527

Model: EP210. Dual channel programmable controller. Installation Manual

Allows detailed and easy monitoring and operation of VRV systems (maximum 2 x 64 groups / indoor units)

Touchpad User Guide (Model: C-LCD-122-TL)

RoomMaster ABR-2. Commissioning

ST9100A User Guide. Features

ACCX Air Conditioning

Programmable Room Thermostat. User Guide UFHPROGB & UFHPROGRFB

Model: TM-1 / TM1-N. 1 Time Clock Series

USER'S GUIDE BARD-LINK TM LC /LC SOLID STATE DUAL UNIT LEAD/LAG CONTROLLER & TEC-EYE HAND-HELD DIAGNOSTIC TOOL

Code of Practice on Services for Pay As You Go Keypad Meter Customers. Ireland has a new energy. Northern Ireland Residential Electricity Customers

User Guide. For controller on CXAO / RTXB heat pumps CGCM / CXCM 2 circuit units. CNT-SVU005C-GB Original instructions

itouch touch screen keypad

METERING/DISPLAY MANUAL

Wall mounted units. Please read carefully and thoroughly this manual before operating this unit and save it in a safe place for future reference.

Quick Reference Card Please consult your spa user manual for complete info on the features of your spa system. in.k1000. touch screen keypad

Security System User Guide

2 Zone Time Clock. User Guide UFHTIME2B

PREPARING FOR 2017/2018 TIMETABLE AND USING OPTIONS

ZONETOUCH DAMPER CONTROL SYSTEM Operation Manual

DFx Series 1e Controller Instruction Manual

The UP and DOWN buttons will toggle or scroll through the options in each section.

7-day room temperature controller

Colour Graphic Terminal User Manual. Rev 3.1

Operation Guide CT101

OPERATION INSTRUCTIONS

Operation Guide CT32 ENGLISH

3000 CONTROLLER TRAINING MANUAL. April 26, 2012 Software Version

Desigo PX PXM20 / PXM20-E operator unit User's guide. Version 6.1 and later. Building Technologies. CM110754en_

WIRED REMOTE CONTROLLER OPERATION MANUAL

National Grid Short Term Operating Reserve System User Manual. National Grid Short Term Operating Reserve System User Manual

Communicating Wall Control Owner s Manual TSTAT0101SC


for User Manual for: Climatix HMI Control Panel Model POL /STD Use on: AHU Application

A quick look at the basic functions of the Hercules Programmable Controller by

Integriti User Manual. Elite / EliteX LCD Terminal Keypads

SUPERVISION AND CONTROL FOR HYDRONIC TERMINAL UNITS

ML Multi Stage Thermostat Installation & User Guide

Operating Instructions. Radio timer thermostat display. Table of contents

7-day room temperature controller

Instruction Manual. ROYTRONIC EXCEL Series AD9 Programming Guide Electronic Metering Pumps

VIPER MANUAL TM0019. TM0019 Page 1 of 48 Issue 2.01

Instructions manual. Thermostat User Manual

TECHNICAL MANUAL. e-kronos Code CB1137. Technical manual e-kronos Rev

Smarther X8000-X8000W

Digital Room Thermostat for Underfloor Heating Applications

M2000/M800 HARDWIRED CONTROL UNITS MANAGER S MANUAL

Desigo Insight Management station, V6.0 Getting started. CM110490en_ Building Technologies

Service Bulletin SB685. Date: 8/18/2017 TriPac EVOLUTION Communications Update Bulletin Location: TSA Info Central\Service Bulletins

U-FLASH Setup Guide U-FLASH.

7 Day Digital Programmer 2 Channel Surface Mount

Chilled Water REMOTE CONTROLLER OPERATION MANUAL MAN-O-CRC4AH intensity.mx

Using your keypad meter card

V0STAT51P-2 Programmable Wired Controller

Weekday / weekend room temperature controller

M2500 Engine Controller Operator Manual

Electronic Tap timer Owners Manual

GRUNDFOS INSTRUCTIONS. Control MPC. Installation and operating instructions

Chapter 3. Using the System CHANGING CHANNELS USING THE MENUS OPENING THE MENUS CLOSING THE MENUS MENU OPTIONS

SERVICE MANUAL VMF-E5

Overview - Danfoss Link and Connect software versions

User Guide. Multipipe Units CMAA / RTMA CNT-SVU004B-GB

Operating Instructions

Instructions for Use

Heatmiser Netmonitor

Transcription:

AMBIFLEX MF626 - USER GUIDE CONTENTS Page No Product Overview 2 Features 3 Standby Display 4 User Facilities 5 Status Display Mode 6 Measured Temperatures 6 Time Channel Information 7 What is happening now? 8 Any problems? 9 User Adjusts 10 Override Actions Dedicated Pushbuttons 11 Override Actions Keypad 13 Alarms/Event lists 14 User Level, Access Unlock 16 Further Info, User Adjusts, Optimisation Times 17 Time Table Scheduling 18 Diary Calendar Scheduling 20 British Summer Time (BST) 22 Access Lock 22 MF626 Menu Map 23 1

PRODUCT OVERVIEW The MF626 is a freely programmable controller with features normally available only in much more expensive systems. It has been designed with override and adjustment facilities for the non technical user. The front panel has a keypad and display that can show temperatures, alarms and generally what is happening with the system at the two User levels and can be used for commissioning at the two Engineer levels. All levels except the lowest user level are password protected. This guide introduces the two user levels A modem may be used on some controllers, allowing automatic dial-out of alarm messages to a PC or standard off the shelf fax machine. Alternatively the controllers can utilise an existing intranet system by communicating via an Ethernet device. For systems requiring greater capacity than that provided by the MF626, please contact the Ambiflex office (details on the back of this booklet). 2

FEATURES As a freely programmable controller the MF626 is capable of sophisticated levels of integrated and demand based control. These would typically include: Optimisation Compensation Boiler sequencing Pump run on Integrated heating and cooling control Independent zone control Multiple stage frost protection Economy settings including high limits for room and outside air Hot water services control including anti-legionella boost Lighting control Meter reading Alarm handling Automatic BST/GMT changeover 3

STANDBY DISPLAY With the MF626 in its normal locked mode, the display reverts to standby mode whenever the escape key is pressed or approximately 20 minutes after the last keystroke by the user. The following information is shown in the standby mode. Machine Type Time, Date & Day MF626 10:14 15/07/02 Monday [0] = Info [#0] = Adjust [# ] = Unlock Quick Keys Machine Type Machine type and revision number. Time, Date, Day Time is in 24 hour format. The date is always displayed in the Day/Month/Year format. Quick Keys The keys to press (shown in brackets) which will take the user directly to that part of the program. 4

USER FACILITIES In addition to the standby display three additional facilities are available to the User in the locked mode. These are: Display Where temperature values and system status conditions may be displayed. User Adjusts Where preprogrammed controlled temperature adjustments may be made. Override Actions Where pre-programmed override actions may be selectively implemented. These are carried out by pressing any of the four black user override buttons: 1 2 3 4 Alternatively further overrides may have been programmed using quick keys as itemised on the standby display in place of the unlock prompt. Words describing the specific override function will appear in the display window when the quick key is pressed. 5

STATUS DISPLAY MODE A wider range of information regarding the status of the MF626 can be displayed in more detail whilst the machine is locked. This is very straightforward only three keys are used: 0 5 and # The 0 key is pressed to access User Display from the standby display. The 5 key is pressed to scroll down the menu from Measured Temps. The # key is pressed to view the items contained in the menu. MEASURED TEMPERATURES Press 0 from the standby display and the screen below will appear. User Display Measured temperatures [#] = view [5] = Channel status [ ] = escape From here each of the measured temperatures in C can be displayed by pressing # to view. These appear on the bottom line with the name on the left, and the value on the right, e.g.: Room 1 21.3 To view the next temperature, press # again and so on. With the cursor flashing on M of Measured temperatures, other status information can be selected for display by pressing 5 Alternatively, to escape to the default display press 6

TIME CHANNEL INFORMATION Key 5 from measured temperatures and the display will change to: User Display Time channel info [#] = view [5] = Current status [ ] = escape From here information concerning each of the time channels can be displayed by repeatedly pressing # These appear on the display and tell the user which time channel it is, whether it is on or off and whether it is in an occupancy period. e.g. Heating On Occupancy [#]=nxtchn With the cursor flashing on T of Time channel info. other status information can be selected for display by pressing 5 Alternatively, to escape to the default display press 7

WHAT IS HAPPENING NOW? Key 5 from time channel info and the display will change to: User Display What is happening now? [#] = view [5] = Fault reports [ ] = escape From here the user can see anything which may be affecting the normal control status by repeatedly pressing # Anything which appears in this section is not a problem but is something which may be holding the boilers/pumps on or off. For example, high outside air temperature holding the heating off as an economy feature. These appear on the bottom line e.g. Heating OFF hi room If there is nothing happening the display reads no news. With the cursor flashing on W of What is happening now? Other status information can be selected for display by pressing 5 Alternatively to escape to the default display press 8

ANY PROBLEMS? Key 5 from what is happening now and the display will change to: User Display Any problems? [#] = view [5] = Temperatures [ ] = escape From here the user can see whether there are any problems that should be reported by repeatedly pressing # If anything appears within this section, contact your maintenance provider. This controller will not show every possible problem that could affect your heating and hot water, however, it may give an early warning. Serious problems will also appear within the Alarm/Event list see page 14. These appear on the bottom line e.g. Room 1 sensor FAULT If there is nothing within this menu the display reads no probs. With the cursor flashing on A of Any problems? the next status information menu Measured temperatures can be accessed by pressing key 5 Alternatively, to escape to the default display, press 9

USER ADJUSTS From the default display press # hold and press 0 These keys pressed together will take the user directly to this screen. User Adjust Room day target 21.0 [9]=change [5]=nxtAdj To change this press 9 and the bottom line of the display changes to: 21.0 [ 2=Up 5=Down 0=Reset #ok ] 2 takes the temperature up by half a degree. 5 takes the temperature down by half degree. 0 takes the temperature to the default programmed in. # accepts the changes made. # again to return to normal display. When the cursor is flashing over User Adjust 1 e.g. Room day target move the cursor to the next setpoint, if one is available. 5 will Alternatively, to escape to the default display, press 10

OVERRIDE ACTIONS DEDICATED PUSHBUTTONS These override actions are accessed via black pushbuttons. The four pushbuttons are normally used for: Heating day extension PB Switch 1 Hot water day extension PB Switch 2 Summer mode PB Switch 3 Holiday mode PB Switch 4 The name of the programmed override function will be shown in the top left hand side of the display screen. Press 1 and the display will show: override name user action required Extend heating by Switch 1 to action exb 00:30 now/no current override status Where Switch 1 to action means press pushbutton 1 to increment day heating extension times by 30 min.when 1 is pressed once, nowno will change to nowyes and Switch 1 to action will change to Switch 1 steptime 1 again and +00:30 changes to +01:00 1 again and +01:00 changes to +01:30 11

The green LED will come on to show that the extension has been programmed, this will then start to flash when the timer has started to run back at the end of normal occupancy. The extension can be programmed in at any time during the day and it will operate once the normal occupancy period has finished. The override action can be cancelled at any time by pressing 1 to access the override from the standby display and then holding 1 down for a minimum of 3 seconds. The nowyes will change to nowno and the green LED will go off. 2 Is normally used to extend the Hot Water On time and the operation is identical to 1 3 The display will normally show: Summer - heating OFF Switch 3 to action now NO Press 3 again and nowno changes to nowyes and the green light alongside flashes. All heating will be switched off but not hot water. This is a manual switch and the effect is immediate, it will also stay active until it is cancelled. The override action can be cancelled at any time by pressing 3 to access the override from the standby display and then pressing 3 again. The nowyes will change to nowno and the green LED will go off. 4 Is used as a Holiday all OFF switch and the operation is identical to 3 N.B. During summer and holiday shutdown frost protection remains active. 12

OVERRIDE ACTIONS KEYPAD Other override actions may have been programmed into your controller if there are any more then there will be a prompt from the standby display as below: MF626 10:14 15/07/02 Monday [0] = Info [#0] = Adjust [9] = Override In the above example an override has been programmed. Press Key typically the display below may appear: 9 and User Action Maintenance Override [#=YES] nowno Normally this is for emergency maintenance use when activated the controller will force everything on for a maximum of thirty minutes as a default setting. 13

ALARMS/EVENT LIST If critical alarms are being monitored by the controller they may either: Bring on the alarm red light Operate the inbuilt sounder Send out an alarm message via a modem or Ethernet device. or any combination of all three. To silence the alarm sounder, or stop the red light flashing, the entire list must be reviewed: A Press the red alarm push button. The display will show the current alarm or event, for example: 1] Node # 35 General Plant fault A _ on @ 09:12 16/03 A maximum of 24 alarms/events can be stored on the list. Node # nn is the internal condition number assigned to that alarm, for Ambiflex engineering use only. 14

If the alarm condition had cleared, the bottom line would read: A _ on @ 09:12 16/03 clr @ 14:10 16/03 Where clr @ hh:mm dd/mm indicates the time and date at which the alarm condition cleared. Keep pressing A and the display will step through the alarm list until the last event has been displayed and the screen will show: Alarm review No more incidents Press [Alarm] to accept You must now press A again to accept and return to the default display. Once accepted the sounder will mute and the red flashing light will become steady. The red light itself will not disappear until the alarm has not only been reviewed but has also cleared. Please contact your service/maintenance provider if the red light has not cleared. 15

USER LEVEL At this level the user may be allowed access to: 1. More user information including engineering information and meter readings. 2. More user adjusts. 3. Optimisation times recorded by the controller. 4. Change the on/off time in an existing time table line. 5. Change existing diary events (holiday dates). From the default display press # hold and press These keys pressed together will take the user directly to this screen. Access Unlock?????? locked Key [9] to open Follow the prompts on the display and press key password: 1 2 1 2 1 2 9 Then enter the low level To accept the password press # hold and press 0 These keys pressed together correctly will pull up this screen. Access Unlock?????? open, user If the bottom line still reads locked then either the password has been entered incorrectly or the # and 0 keys have not been pressed together correctly. Press key to return to the standby display. 16

FURTHER USER INFORMATION From the standby display press 0 for information, then press 5 to scroll down the User Display menu until Info for engineers is reached. Typically diagnostic information will be stored here. Press # to view. If key 5 is pressed again then Accumulator values should appear. Press # to view. Any meter readings will be here as well as boiler run hours, pump run hours etc. Press the key to return to the standby display. FURTHER USER ADJUSTS From the standby display press # hold and press 0 These keys pressed together correctly should pull up the User Adjust screen automatically. Navigate down from User Adjust Setpoint 1 by pressing key 5 Further user adjusts may appear. Edit these by following the prompts on the display (see Page 10). Press the key to return to the standby display. OPTIMISATION TIMES From the standby display press # hold and press 0 These keys pressed together correctly should pull up the User Adjust screen automatically. Move the cursor from the first setpoint to Adjust by pressing key 1 then navigate down through the menu to Optimes by pressing key 5 Press # to view. A log will appear showing when the system has optimised on and off with a date stamp. Any day which does not appear means that there was no optimisation on that day. Press the key to return to the standby display. 17

TIME TABLE SCHEDULING For most day to day operation it is not necessary to make changes to the Time Schedule settings. This is because override facilities are provided by the 4 black pushbuttons. When the controller has been unlocked to User Level as previously described (See Page 16) then the on/off times of an existing time table line may be altered. It does not allow the user to: a. Add new switching times. b. Delete existing time switching commands. Please ask your service engineer about adding and deleting time commands. From the standby display position press # + 2 together and the display changes to: TimeTabl Review chnl 1 Any day Heating [#] = view [5] = nxt chn # View the time table for channel 1 on every day of the week e.g. TimeTabl [time ch: Channel 1 ] Chn 1 Opsrt 12345.. 07:30 Therefore on Channel 1 there is an optimised start on Monday to Friday at 7:30 in the morning. A cursor appears on the bottom line and this can be moved by using the cursor keys on the keypad 2 is up, 5 is down, 1 is left and 3 is right. As the cursor is moved an expanded description appears on the top line. 18

For example, if the cursor is under the command section Opsrt, the upper line will read: TimeTabl [command: Optimised START ] Where a dot. appears it means that the same command is set for the same time for the day where the dot is positioned, i.e. a dot in position 3 would mean the same command is set for Wednesday. A dash _ means the command is not set for that day. Repeat pressing # to view all command lines for channel 1. Then 5 to move the cursor from Chnl 1 to Chnl 2 to view other existing time channels. To change the on/off time of a command line first select the required Time Channel, then carry out the review procedure for that channel for Any day by pressing # until the line to be changed appears on the bottom line of the display, move the cursor over the time by pressing key 3 then key 9 to edit. If the controller is not already unlocked this option will change the display to the Access Menu for the password to be entered. When this has been done, the controller will automatically revert the screen back to the event to be altered. 9 And the cursor will move to the left hand digit of the time currently set. h h m m to enter the new switching time. e.g. 0 7 4 5 would set a time of 07:45 (24 hour format). Once the correct time has been set, it can be entered into the system by # + 0 together once. Then keep pressing # until no more appears on the bottom line. To make changes to other time channels, select the required channel by scrolling ( 5 or 2 ) whilst the cursor is on the top line next to chnl. Press the key to return to the standby display. 19

DIARY - CALENDAR SCHEDULING At USER level access, existing dates for suspending and restoring daily time schedules may be changed. CHANGING EXISTING DIARY DATES As a standard convention, all MF626 controllers are programmed to the following statement: The holiday dates make all channels inactive i.e. suspend all daily time programmes. The holiday dates are inclusive i.e. normal operation resumes the day after the last date entered. From the standby display position press # + 3 together and the display will show typically: Diary Review [#]=view [5]=D.Logs Move the cursor from Diary to Review by pressing key 3 and press # to view the default Diary Event, which appears as: Holiday Cal: all OFF 25/12/xx to 26/12 After reviewing existing dates, review again until the first date to be changed is displayed then Key 9 to edit, if the controller if not already unlocked this option will change the display to the Access Menu for the password to be entered. When this has been done, the controller will automatically revert the screen back to the event to be altered. 20

9 then select event required i.e. Holiday # + 0 to accept. Then key in the start date, this is in Date/Month/Year format. If only the Date and Month are entered then this event will occur every year, otherwise if a specific year is entered, the event will be deleted once it has occurred. # + 0 to accept. Then key in the date for the last day of holiday operation e.g. A holiday like Christmas Day and Boxing Day occurring every year could be entered as: Holiday call: all OFF 25/12/xx to 26/12 # + 0 to accept. # to move to the next event to be edited. Carry on until all dates have been reviewed, changed and accepted. N.B. CALENDAR DATES IN THE DIARY CAN ROLL CONTINUOUSLY OR BE YEAR SPECIFIC. Inserting and deleting calendar dates can only be done at higher levels of access, please ask your service and maintenance engineer for further information. 21

BRITISH SUMMER TIME (BST) The default for the BST start date is set with the month only, e.g. 00/03 for March the MF626 will change from Winter to Summer Time automatically at 02:00 on the last Sunday in March, every year. The GMT start date is also set with the month only, e.g. 00/10 Occasionally this will be wrong for a period of 1 week only in some years when the time change takes place on the Sunday before the last Sunday in the month. Specific dates can be entered into the controller if required from Service level access and above. ACCESS LOCK From the default display press # hold and press These keys pressed together will take the user directly to this screen. Access Unlock?????? open, user Press key 1 to move the cursor to Unlock then key 5 to change to Lock. Follow the prompts on the display and press key 9 Then change the setting to locked by pressing key 5 and update the controller by pressing the # and 0 keys together. Press the key to return to the standby display. 22

MF626 Menu Map User Action Programmed Action Display Measured temperatures Time channel info. What is happening now? Any problems? Info for engineers. Accumulator Values Adjust Room day target etc OpTimes Access Lock Unlock TimeTabl Review Heating etc Anyday DLinkStat CalSched Review Status Datalogs View #1 Daily etc Timekeep Clockset The above is for free access and USER level access. 23