PV Inverter SUNNY BOY 2000HF-US/2500HF-US/3000HF-US

Similar documents
PV Inverter SUNNY BOY 3000TL-US / 3800TL-US / 4000TL-US / 5000TL-US / 6000TL-US / 7000TL-US / 7700TL-US

PV Inverter SUNNY BOY 3000 US 3800 US 4000 US

Installation Manual SMA RS485 MODULE

hdpv.org Ampt Communications Unit Installation Manual D

NIMBUS a personal dashboard for your digital life

Bluetooth Mini Keyboard. User s Manual. Version /05 ID NO: PAKL-231B

System Manual COMPACT MV POWER PLATFORM

Big Blue Wireless Earbuds CRYSTAL CLEAR MUSIC AND PHONE CALLS ON THE GO

Wireless Noise Cancelling Earbuds HEAR YOUR MUSIC AND NOTHING ELSE

User Manual SMA CLUSTER CONTROLLER

Z-Wave 4-in-1 Multi Sensor HZS-300E/HZS-300A

Z-Wave Ceiling-mount Smoke Detector HZS-200E/HZS-200A

Logitech Alert 700i/750i System Requirements & Support Guide

Owner s Instruction Manual

Communication Interface for SMA Inverters SMA BLUETOOTH PIGGY-BACK

Always there to help you. Register your product and get support at AEA1000. Question? Contact Philips.

Central Inverter MV POWER PLATFORM 1.0 MW / 1.25 MW / 1.44 MW MV POWER PLATFORM 1.5 MW / 1.6 MW Open/Canopy Version with Disconnect Unit

INSTALLATION INSTRUCTIONS

INDOOR/OUTDOOR SPEAKER WITH BLUETOOTH WIRELESS TECHNOLOGY PART NUMBER PA360 EXPERIENCE 360 OF SOUND. pulseaudio1.com vanco1.com


+Cam Quick Start Guide

Installation Manual SMA SENSOR MODULE

INSTALLATION GUIDE DM-20 English Version 1.10 EN DM20 V1.10A

PUSH-TO-TALK USER GUIDE

4 Port USB Power Hub. Model: JH-800 USER MANUAL

TRF-ZW1 Z-Wave Extender. Owner s Manual

BLUETOOTH SPEAKER. for ipod/iphone/ipad/android. User s Manual. Item #TA-11BTSP. PC Mac Ultrabook COMPATIBLE BLUETOOTH WIRELESS USB

Bluetooth Enabled Access Control MODEL BG-FE. Operating Instructions

Wireless Surround Sound Earphones WITH REVERSE SOUND TECHNOLOGY

PTT-100-VZ Wireless Speaker Microphone

Labtec Wireless Optical Desktop. Getting Started Guide

USER GUIDE. Laptop Charger NS-PWLC591/NS-PWLC591-C. Before using your new product, please read these instructions to prevent any damage.

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

mart atch B502 User Manual

Disclaimers. Important Notice

HD40H(X) Performance Series Camera. User Guide

Disclaimers. Important Notice

GUIDELINES LAID DOWN BY FCC RULES FOR USE OF THE UNIT IN THE U.S.A. (not applicable to other areas). NOTICE

Lightshow Box with Speaker

Contents Attentions... 2 Preparation... 4 Technical Specification... 7

LED FOLDING WORKLIGHT TM

EN-9235TX-32 Quick Installation Guide

Central Inverter MV POWER PLATFORM 1.0 MW / 1.25 MW / 1.44 MW MV POWER PLATFORM 1.5 MW / 1.6 MW Enclosure Version without Disconnect Unit

User Guide Wireless Charging Plate DT-903

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

Wireless 3D Headphones VIRTUAL 3D SURROUND SOUND ACTIVE NOISE CANCELLATION

BW50 SportBuds. User Guide. Control Buttons & Operations. On / Off. Play / Pause / Answer. Volume / Track Selection. Models: GDI-EXBW50...

PLEASE READ BEFORE OPERATING THIS EQUIPMENT.

Bluetooth Wireless Technology Enabled Optical Mouse

Activity Tracker. User s Manual

Blackwire C610 Blackwire C620

User Guide Microsoft Portable Power (DC-21)

EXO-110 Bluetooth Headband

Hardware Installation 1. Install two AA batteries in the mouse. Pairing Process in Vista and Windows XP SP2

SMART SWITCH. User s Manual. This product is to be used with the MySmartBlinds automation kit.

Wireless Smart Pad And Mini Keyboard User s Manual

Super Stack. (Little Stack Wireless + Big Stack)

Bluetooth USB Adapter TALUS. User Guide

USER GUIDE. Element Wireless Smart Plug Model: E1C-NB6

Maintenance Manual SUNNY CENTRAL 500CP-US/CA / 500CP-US/CA 600V / 630CP-US/CA / 720CP-US/CA / 750CP-US/CA / 800CP-US/CA / 850CP-US/CA / 900CP-US/CA

4 Channel RFID reader LF 125KHz with CAN bus LT-LFS03 USER MANUAL

Operating Instructions

BLUETOOTH RECEIVER (RX) FOR IPOD DOCKING SPEAKER

1. Product Description. 2. Product Overview

Installation/User Manual

SySTIUM TECHNOLOGIES. Assembly Guide. Model 133i

QUICK INSTALL GUIDE. YourType FOLIO + KEYBOARD

SPOTTER the multipurpose sensor

FCC ID: 2AJQ5GPDPOCKET2 Model Name : Pocket 2. Chapter one Start to learn your computer

USB Transfer Cable. for Windows and Mac User s Guide

OWC Mercury On-The-Go Pro USER GUIDE

BTH-800. Wireless Ear Muff headset with PTT function

Wa r n i n g-wa r n i n g-wa r n i n g

W10 PRO QUICK START GUIDE

User Guide Nokia Wireless Charger DT-601

Quick Start Guide KB20. A3 10 Type Case CJB1G9KALAAB

Always there to help you. Register your product and get support at SHL3750NC. Question? Contact Philips.


Quick Start Guide Bluetooth to Serial Adapter

WS must be used in a temperature controlled place. It is compliant to ETS Class T

Smartphone Photo Printer

1. Product description

Activity Tracker. User s Manual. Model No. Model No. Model No. Model No. IFACT115.0 IFACT215.0 IFVUEWM115.0 IFVUEWM215.0

BTH-900. Wireless Ear Muff headset w/dual Connections

powerstation keychain Made for USB-C smartphones and wearables USER MANUAL

Chicony Standard Bluetooth Keyboard Users Manual. Model No.: KT-1063

user s manual Battery case model #: IPB3500S Battery Case Charger for iphone 6

WorkForce 1100 Series. Notices and Warranty

iq 16 Sync Charge Box

MW-145BT Mobile Printer

Serial Port Plug - F2M01SXA Brief Datasheet. Features. Applications. General Description. Provides transparent RS-232 serial cable replacement.

PRODUCT DIAGRAM PACKAGE CONTENTS

550 Watt Power Supply

Bluetooth Stereo Headset

Prime bolt User Manual

Installation/User Manual

WIRELESS BLUETOOTH BOOMBOX

W Remote Control 1

OWC Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE

BLUETOOTH EARPHONES ITEM NO.: NJEP- 1. Quick Start Guide

Transcription:

PV Inverter SUNNY BOY 2000HF-US/2500HF-US/3000HF-US User Manual HF_STP_US-BUS095110 TBUS-20HF Version 1.0 CA US

Power curve or energy curve of the past 16 feedin hours or past 16 days (switching the display is done by knocking on the lid) Failure that can be removed on-site (see chapter 10.3 ) Device fault Please contact SMA. Knocking on the upper lid: Activating the background illumination Switching through the power values of the past 16 feedin hours to the daily power values of the past 16 days Switching through the line display Bluetooth connection to other Sunny Boys Grid relay Input voltage / input current Output voltage / output current PV array event number Power reduction due to excessive temperature Clean the fan (if necessary) Sunny Boy might need better ventilation Grid event number Sunny Boy event number Actual output Daily energy Total energy fed in since the Sunny Boy was installed Event text

SMA America, LLC Legal Restrictions Copyright 2011 SMA America, LLC. All rights reserved. No part of this document may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photographic, magnetic or otherwise, without the prior written permission of SMA America, LLC. Neither SMA America, LLC nor SMA Solar Technology Canada Inc. makes no representations, express or implied, with respect to this documentation or any of the equipment and/or software it may describe, including (with no limitation) any implied warranties of utility, merchantability, or fitness for any particular purpose. All such warranties are expressly disclaimed. Neither SMA America, LLC nor its distributors or dealers nor SMA Solar Technology Canada Inc. nor its distributors or dealers shall be liable for any indirect, incidental, or consequential damages under any circumstances. (The exclusion of implied warranties may not apply in all cases under some statutes, and thus the above exclusion may not apply.) Specifications are subject to change without notice. Every attempt has been made to make this document complete, accurate and up-to-date. Readers are cautioned, however, that SMA America, LLC and SMA Solar Technology Canada Inc. reserve the right to make changes without notice and shall not be responsible for any damages, including indirect, incidental or consequential damages, caused by reliance on the material presented, including, but not limited to, omissions, typographical errors, arithmetical errors or listing errors in the content material. All trademarks are recognized even if these are not marked separately. Missing designations do not mean that a product or brand is not a registered trademark. The Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by SMA America, LLC and SMA Solar Technology Canada Inc. is under license. SMA America, LLC 3801 N. Havana Street Denver, CO 80239 U.S.A. SMA Solar Technology Canada Inc. 2425 Matheson Blvd 8th Floor Mississauga, ON L4W 5K5 Canada User Manual HF_STP_US-BUS095110 3

Important Safety Instructions SMA America, LLC IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for models Sunny Boy 2000HF US, 2500HF US, 3000HF US PV inverter, that must be followed during installation and maintenance of the PV inverter. The models Sunny Boy 2000HF-US, 2500HF-US, 3000HF-US are designed and tested according to international safety requirements, but as with all electrical and electronic equipment, certain precautions must be observed when installing and/or operating the models Sunny Boy 2000HF-US, 2500HF-US, 3000HF-US. To reduce the risk of personal injury and to ensure the safe installation and operation of the models Sunny Boy 2000HF-US, 2500HF-US, 3000HF-US, you must carefully read and follow all instructions, cautions and warnings in this user manual. Warnings in this document A warning describes a hazard to equipment or personnel. It calls attention to a procedure or practice, which, if not correctly performed or adhered to, could result in damage to or destruction of part or all of the SMA equipment and/or other equipment connected to the SMA equipment or personal injury. DANGER DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury. CAUTION CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE NOTICE is used to address practices not related to personal injury. 4 HF_STP_US-BUS095110 User Manual

SMA America, LLC Important Safety Instructions Other Symbols in this document In addition to the safety and hazard symbols described on the previous pages, the following symbol is also used in this user manual: Information This symbol accompanies notes that call attention to supplementary information that you must know and use to ensure optimal operation of the system. Markings on this product The following symbols are used as product markings with the following meanings. Warning regarding dangerous voltage The product works with high voltages. All work on the product must only be performed as described in it s documentation. Beware of hot surface The product can become hot during operation. Do not touch the product during operation. Observe the operating instructions Read the product s documentation before working on it. Follow all safety precautions and instructions as described in the documentation. This inverter is evaluated to UL 1741, which includes assessment to all of the requirements of IEEE1547 and IEEE1547.1, which are an outgrowth and further development of the IEEE recommended practices and guidelines contained in IEEE Std. 929-2000. IEEE 929-2000 provides recommendations regarding the proper equipment and functionality necessary to ensure compatible operation when power generation is connected to the utility grid. The inverter is additionally evaluated to CAN/CSA C22.2 No. 107.1-1. User Manual HF_STP_US-BUS095110 5

General Warnings SMA America, LLC General Warnings General Warnings All electrical installations must be done in accordance with the local codes and National Electrical Code ANSI/NFPA 70 or the Canadian Electrical Code CSA C22.1. The Sunny Boy contains no user-serviceable parts except for the fan on the bottom of the enclosure. For all repair and maintenance always return the unit to an authorized SMA Service Center. Before installing or using the Sunny Boy, read all of the instructions, cautions, and warnings on the Sunny Boy in this installation guide. Before connecting the Sunny Boy to the power distribution grid, contact the local power distribution grid company. This connection must be made only by qualified personnel. 6 HF_STP_US-BUS095110 User Manual

SMA America, LLC Table of Contents Table of Contents 1 Notes on this Manual.............................. 9 1.1 Validity............................................ 9 1.2 Target Group....................................... 9 1.3 Additional Information................................ 9 1.4 Nomenclature....................................... 9 2 Safety......................................... 10 2.1 Appropriate Usage.................................. 10 2.2 Safety Instructions................................... 11 2.3 Identifying the Product............................... 12 3 Operating Modes................................ 13 3.1 LED Displays....................................... 14 3.1.1 All LEDs are off............................................... 14 3.1.2 Green LED is flashing.......................................... 14 3.1.3 Green LED is continuously lit..................................... 14 3.1.4 Red LED is continuously lit....................................... 15 3.1.5 Blue LED is continuously lit...................................... 15 4 Information on the Display........................ 16 4.1 Display Information Overview......................... 16 5 Maintenance and Cleaning........................ 19 5.1 Cleaning the Fan.................................... 19 5.2 Cleaning the Display................................. 19 5.3 Checking the SMA DC Disconnect...................... 20 6 FCC Compliance Information...................... 21 7 Contact........................................ 22 User Manual HF_STP_US-BUS095110 7

Table of Contents SMA America, LLC 8 HF_STP_US-BUS095110 User Manual

SMA America, LLC Notes on this Manual 1 Notes on this Manual This manual contains instructions for operating the Sunny Boy inverter. Store this manual so that it is always easily accessible. 1.1 Validity This manual applies to the following inverters: Sunny Boy 2000HF-US (SB 2000HF-US 30) Sunny Boy 2500HF-US (SB 2500HF-US 30) Sunny Boy 3000HF-US (SB 3000HF-US 30) 1.2 Target Group This manual has been prepared for use by qualified personnel and those operating the inverter. Activities to be carried out by qualified personnel have been noted with safety instructions. Qualified Personnel Qualified personnel have received training and have demonstrated skills and knowledge in the construction and operation of the device. Qualified personnel are trained to deal with the dangers and hazards involved in installing electric devices. Operator The operator has been adequately trained and instructed by qualified personnel in order to ensure safe operation of the inverter. 1.3 Additional Information The installation guide included with the equipment contains information regarding assembly, installation, commissioning and maintenance of the inverter as well as technical specifications pertaining to the equipment. Further information about SMA America Production, LLC equipment is available in the download section of the website www.sma-america.com. The download section includes, among others, the technical description: SMA Bluetooth Wireless Technology. 1.4 Nomenclature In this document SMA America Production, LLC and SMA Solar Technology Canada Inc. are referred to in the following as SMA. User Manual HF_STP_US-BUS095110 9

Safety SMA America, LLC 2 Safety 2.1 Appropriate Usage The Sunny Boy is a solar inverter that converts the DC current of the PV array into an AC current and feeds it into the grid. Refer to the inverter installation guide for detailed information about the product and its intended use. The limit values specified in the installation guide of the respective inverter must be strictly adhered to. The inverter may only be operated with PV arrays (modules and cabling) that have protective insulation. Do not connect any power sources other than PV modules to the inverter. Do not use the inverter for purposes other than those described here. Alternative uses, modifications to the inverter or the installation of components not expressly recommended or sold by the manufacturer void the warranty claims and operating permission. Contact the SMA Serviceline if you need clarification regarding proper use of the inverter. Principle of the string inverter The string inverter connects solar modules that are connected in series (strings) to the power distribution grid. Thus, even large PV arrays can be set up using multiple individual strings, each having its own respective string inverter. Principle of a grid-connected PV system with a Sunny Boy Position A B C D E F Description PV array Sunny Boy with integrated DC disconnect Line circuit breaker Load Engery meter Power distribution grid 10 HF_STP_US-BUS095110 User Manual

SMA America, LLC Safety 2.2 Safety Instructions DANGER High voltages in the inverter. Death resulting from electric shock and burns. The following work on the inverter may be carried out by qualified personnel only. Electrical installation Repairs Modification Even if an external supply is not present, the equipment may still be under high voltage. This high voltage can lead to death or severe injuries. CAUTION The enclosure of the Sunny Boy can get hot during operation. Risk of burn injuries. Do not touch the enclosure during operation. Only touch the lid and display during operation. NOTICE Damage to the inverter due to overvoltage. Verify that the DC voltage of your installation does not exceed the maximum values specified on the type rating label. User Manual HF_STP_US-BUS095110 11

Safety SMA America, LLC 2.3 Identifying the Product You can identify the inverter by the type plate. The type plate is on the right side of the enclosure. The type plate specifies among other things the device type (Type / Model), the serial number (Serial No.) and device-specific key data of the product. 12 HF_STP_US-BUS095110 User Manual

SMA America, LLC Operating Modes 3 Operating Modes The inverter indicates various operating conditions with the help of 3 LEDs on the enclosure lid. The equipment must be connected to a DC power supply. Furthermore the equipment must be connected to the grid on the AC side to be able to indicate its operational state via display and integrated LEDs. There must be adequate solar radiation for the inverter to receive the necessary DC voltage. LED A B C Description Green LED LED lit: Inverter in normal operating mode LED flashing: Inverter waiting for adequate solar radiation Red LED LED lit: Fault in the inverter. Note the serial number of the inverter and the fault number and contact your installer. The fault number is indicated on the inverter display unit. Blue LED LED lit: Inverter is connected to a Bluetooth network and can communicate with other devices having the same NetID. LED display In case you do not have any communication devices available, monitor the LEDs of the inverter and graphic display regularly at various times during the day and under varying conditions of solar radiation, particularly in the first year after installation. Thus, you can detect any potential faults in the system in a timely manner. The following section contains a detailed description of various LED displays and inverter operating states. User Manual HF_STP_US-BUS095110 13

Operating Modes SMA America, LLC 3.1 LED Displays 3.1.1 All LEDs are off Overnight shutdown The DC voltage on the inverter is too low for grid feeding. If this operating state occurs during the day with proper solar radiation, have your installer check the DC voltage. 3.1.2 Green LED is flashing Startup The DC voltage is adequate for the inverter to be calibrated. However, the DC voltage is not adequate for feeding operation of the inverter. Usually, inverter calibration requires less than 10 seconds. Thereafter, the inverter commences normal feeding operation. 3.1.3 Green LED is continuously lit Feeding operation The inverter is operating normally and is feeding power to the power distribution grid. 14 HF_STP_US-BUS095110 User Manual

SMA America, LLC Operating Modes 3.1.4 Red LED is continuously lit The inverter has detected a malfunction within the device or in the grid. The inverter has disconnected from the power distribution grid. The inverter indicates the error number on the display unit (see section 4.1 Display Information Overview (page 16)). Note the serial number of the inverter and the error number and contact your installer. Troubleshooting by installer Contact your installation technician, who will troubleshoot the error or get in touch with the SMA Serviceline. 3.1.5 Blue LED is continuously lit The inverter is connected to a Bluetooth network. User Manual HF_STP_US-BUS095110 15

Information on the Display SMA America, LLC 4 Information on the Display The Sunny Boy provides information on the display unit during operation. Activate display unit background illumination Activate the display background illumination by tapping on the cover of the enclosure lid. The background illumination switches off automatically. 4.1 Display Information Overview Position A B C D E Description Performance chart of the past 16 hours / last 16 days. The inverter displays the feed-in power in the performance diagram. By default, the inverter displays the feed-in power of the past 16 hours. The inverter refreshes the display every 5 seconds. When you tap on the cover of the enclosure lid, the display changes and shows the power fed over the past 16 days. A malfunction has occurred. The inverter displays this icon when it detects a malfunction in the equipment or the power grid. The inverter indicates the error number on its display unit. Note the serial number of the inverter and the error number and contact your installer. Current inverter output power. Total energy produced on this day. Total energy output of the inverter since commissioning. 16 HF_STP_US-BUS095110 User Manual

SMA America, LLC Information on the Display Position A B C D Description Current DC voltage at the inverter. Quality of the link to other PV system Bluetooth devices. You can see whether the inverter has a radio link to a device of its PV system on the link quality icon. The number of rings indicates the quality of the Bluetooth connection between the devices. The more rings displayed, the better the link quality. Status display of power feed Switch closed: The Sunny Boy feeds power to the power distribution grid and supplies power to loads connected to it directly. Switch open: The Sunny Boy does not feed power into the power distribution grid and does not supply power to any loads connected to it directly. Current AC main voltage User Manual HF_STP_US-BUS095110 17

Information on the Display SMA America, LLC Position A B C D E Description PV array event number Shows events that have occurred on the PV array. Warning icon for power reduction. The temperature in the inverter is too high. The inverter reduces power output in order to cool down. If the inverter fan is dirty, clean it (see section 5.1 Cleaning the Fan (page 19)). If the inverter displays the icon even after the fan has been cleaned, ensure proper ventilation. Inverter event number. It displays events that have occurred on the inverter. Grid event number. This displays events that have taken place on the power distribution grid. Event display line of text. The text field displays additional information if any events have occurred on the PV array or on the power distribution grid. Tapping on the lid leads you to further information on the event. Display messages The inverter installation manual provides detailed information regarding event numbers, various error and malfunction messages. Measurement accuracy The inverter does not have a calibrated meter. The values on the display unit may differ from the actual values. You may not use the values as the basis for any billing purposes. 18 HF_STP_US-BUS095110 User Manual

SMA America, LLC Maintenance and Cleaning 5 Maintenance and Cleaning Check for proper inverter operation at regular intervals. Dirt, such as dust, can cause heat accumulation, which can lead to yield losses. Check the inverter and cables for any signs of external damage. Have repairs carried out if necessary. 5.1 Cleaning the Fan WARNING Only qualified personnel may dismantle the inverter fan. The procedure for dismantling the fan for cleaning is described in the inverter installation guide. If the fan guards are dirty with loose dust, then you can clean them with a vacuum cleaner. Hold the pipe of the vacuum cleaner below the fan of the inverter (see Figure). If you are unable to clean the fan properly, contact your installer who will dismantle the fan in order to clean it. 5.2 Cleaning the Display If the status LED's or the display unit are dirty and cannot be read clearly, clean them using a moist cloth. Cleaning the status LED's and the display unit Do not use any solvents, abrasives or corrosive substances for cleaning. User Manual HF_STP_US-BUS095110 19

Maintenance and Cleaning SMA America, LLC 5.3 Checking the SMA DC Disconnect When used appropriatly the SMA DC Disconnect does not need maintenance. It is recommended, though not compulsory to: Check the SMA DC Disconnect regularly. Operate the SMA DC Disconnect once a year 10 times. Operating the switch will clean the contacts of the SMA DC Disconnect. 20 HF_STP_US-BUS095110 User Manual

SMA America, LLC FCC Compliance Information 6 FCC Compliance Information SMA PV inverter, model Sunny Boy 2000HF-US, Sunny Boy 2500HF-US, Sunny Boy 3000HF-US This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and the receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help. The user is cautioned that changes or modifications not expressly approved by SMA America, LLC could void the user s authority to operate this equipment. Contact SMA America for more information. RF-exposure Statement The SMA Sunny Boy 2000HF-US, Sunny Boy 2500HF-US, Sunny Boy 3000HF-US contains a modular transmitter. Thus it must have a separation of at least 8 in. (20 cm) between the antenna and the body of the user or nearby persons, excluding hands, wrists, feet, and ankles. User Manual HF_STP_US-BUS095110 21

Contact SMA America, LLC 7 Contact If you have technical problems with our products, please contact our Serviceline. We require the following information in order to provide you with the necessary assistance: Inverter type Serial number of the Sunny Boy Type and number of modules connected Event number or display message of the Sunny Boy Type of communication, if applicable Type of fault signaling contact connected, if applicable SMA Solar Technology America, LLC 6020 West Oaks Blvd, Ste 300 Rocklin, CA 95765 Tel. +1 916 625 0870 Tel. +1 877-MY SMA TECH Tel. +1 877 697 6283 (Toll free, available for USA, Canada and Puerto Rico) Fax +1 916 625 0871 Service@SMA-America.com www.sma-america.com SMA Solar Technology Canada Inc. 2425 Matheson Blvd, 8th Floor Mississauga, ON L4W 5K5, Canada Tel. +1 877 506 1756 (Toll free, available for Canada) Service@SMA-Canada.ca www.sma-canada.ca 22 HF_STP_US-BUS095110 User Manual

For product and purchase inquiries contact: www.ecodirect.com