Data sheet SIMATIC HMI KTP900F MOBILE, 9.0'' TFT DISPLAY, 800 X 480 PIXELS,16M COLOR, KEY AND TOUCH OPERATION, 10 FUNCTION KEYS, 1 X PROFINET/INDUSTRIAL ETHERNET INTERFACE; 1 X MULTIMEDIA CARD, 1 X USB, ACKNOWLEDGEMENT SWITCH, EMERGENCY-STOP BUTTON, CONFIGURABLE FROM WINCC COMFORT V13 SP1 General information Product type designation SIMATIC HMI KTP900F Mobile Display Design of display TFT widescreen display, LED backlighting Screen diagonal 9 in Number of colors 16 777 216 Resolution (pixels) Horizontal image resolution 800 Pixel Vertical image resolution 480 Pixel Backlighting MTBF backlighting (at 25 C) 50 000 h Backlight dimmable ; 0-100 % Control elements Keyboard fonts Function keys Number of function keys 10 Keys with LED System keys Page 1/10 24.03.2016 Copyright Siemens AG
Numeric/alphabetical input Numeric keyboard ; Onscreen keyboard alphanumeric keyboard ; Onscreen keyboard Touch operation Design as touch screen Design as multitouch screen Special operator controls Stop button (forced blocking) Emergency stop button (forced blocking) Emergency stop button (illuminated and forced blocking) Acknowledgement button (3-stage) Key-operated switch Illuminated pushbutton Camera integrated camera Expansions for operator control of the process DP direct LEDs (LEDs as S7 output I/O) F1...Fx 10 Direct keys (keys as S7 input I/O) F1...Fx 10 Direct keys (touch buttons as S7 input I/O) 32 Supply voltage Type of supply voltage Rated value (DC) permissible range, lower limit (DC) permissible range, upper limit (DC) Input current Current consumption (rated value) Starting current inrush I²t Power Power consumption, typ. Processor Processor type Memory Flash RAM Memory available for user data Type of output Power LED DC 24 V 19.2 V 28.8 V 450 ma 0.135 A² s 11 W ARM 12 Mbyte Page 2/10 24.03.2016 Copyright Siemens AG
LED for safe LED for communication LED for battery Vibrations Time of day Clock Hardware clock (real-time clock) Software clock retentive synchronizable Interfaces Number of industrial Ethernet interfaces 1 Number of PROFINET interfaces 1 Number of RS 485 interfaces 0 Number of USB interfaces 1; USB 2.0 Number of 20 ma interfaces (TTY) 0 Number of RS 232 interfaces 0 Number of RS 422 interfaces 0 Number of parallel interfaces 0 Number of other interfaces 0 Number of SD card slots 1 With software interfaces WLAN Number of wireless interfaces 0 Protocols PROFINET Supports protocol for PROFINET IO PROFIsafe PROFIBUS MPI Protocols (Ethernet) TCP/IP DHCP SNMP DCP LLDP WEB characteristics HTTP HTTPS HTML XML Page 3/10 24.03.2016 Copyright Siemens AG
CSS Active X JavaScript Java VM Further protocols MODBUS EtherNet/IP other bus systems Communication functions Wireless communication supported standards Radio standard WLAN 802.11 Bluetooth radio standard Interrupts/diagnostics/status information Diagnostic messages Diagnostic information readable EMC Emission of radio interference acc. to EN 55 011 Limit class A, for use in industrial areas Limit class B, for use in residential areas Degree and class of protection IP65 (all-round) Standards, approvals, certificates CE mark culus RCM (formerly C-TICK) KC approval Suitable for safety functions Marine approval Germanischer Lloyd (GL) American Bureau of Shipping (ABS) Bureau Veritas (BV) Det rske Veritas (DNV) Lloyds Register of Shipping (LRS) Nippon Kaiji Kyokai (Class NK) Polski Rejestr Statkow (PRS) Highest safety class achievable in safety mode Performance level according to EN ISO 13849- PLe 1:2008 SIL acc. to IEC 61508 SIL 3 Page 4/10 24.03.2016 Copyright Siemens AG
Use in hazardous areas ATEX Zone 2 ATEX Zone 22 IECEx Zone 2 IECEx Zone 22 culus Class I Zone 1 culus Class I Zone 2, Division 2 FM Class I Division 2 Ambient conditions Free fall Fall height, max. 1.2 m Ambient temperature during operation min. 0 C max. 45 C Ambient temperature during storage/transportation min. -20 C max. 60 C Relative humidity Operation, max. 90 % Operating systems proprietary pre-installed operating system Windows CE Configuration Message indicator Alarm logging system (incl. buffer and acknowledgment) Process value display (output) Process value default (input) possible Recipe administration Configuration software STEP 7 Basic (TIA Portal) STEP 7 Professional (TIA Portal) WinCC flexible Compact WinCC flexible Standard WinCC flexible Advanced WinCC Basic (TIA Portal) WinCC Comfort (TIA Portal) WinCC Advanced (TIA Portal) WinCC Professional (TIA Portal) Page 5/10 24.03.2016 Copyright Siemens AG
Languages Online languages Number of online/runtime languages 32 Project languages Languages per project 32 Functionality under WinCC (TIA Portal) Libraries Applications/options Web browser Pocket Word Pocket Excel PDF Viewer Media Player SIMATIC WinCC Sm@rtServer SIMATIC WinCC Audit Number of Visual Basic Scripts Task planner time-controlled task-controlled Help system Number of characters per info text 500 Multiproject Number of projects (internal) 0 Number of projects (external) 0 Message system Number of alarm classes 32 Bit messages Number of bit messages 4 000 Analog messages Number of analog messages 200 S7 alarm number procedure System messages HMI System messages, other (SIMATIC S7, Sinumerik, Simotion, etc.) Number of characters per message 80 Number of process values per message 8 Acknowledgment groups Message indicator Message buffer Number of entries 1 024 Circulating buffer Page 6/10 24.03.2016 Copyright Siemens AG
retentive maintenance-free Recipe administration Number of recipes 300 Data records per recipe 500 Entries per data record 1 000 Size of internal recipe memory 2 Mbyte Recipe memory expandable Variables Number of variables per device 2 048 Number of variables per screen 400 Limit values Multiplexing Structures Arrays Images Number of configurable images 500 Permanent window/default Global image Image selection by PLC Image number in the PLC Image objects Number of objects per image 400 Text fields I/O fields Graphic I/O fields (graphics list) Symbolic I/O fields (text list) Date/time fields Switches Graphic display Icons Geometric objects Complex image objects Number of complex objects per screen 20 Alarm view Trend view User view Status/control Sm@rtClient view Recipe view f(x) trend view Page 7/10 24.03.2016 Copyright Siemens AG
System diagnostics view Media Player Bar graphs Sliders Pointer instruments Analog/digital clock Lists Number of text lists per project 500 Number of entries per text list 500 Number of graphics lists per project 500 Number of entries per graphics list 500 Archiving Number of archives per device 50 Number of entries per archive 20 000 Message archive Process value archive Archiving methods Sequential archive Short-term archive Memory location Memory card USB memory Ethernet Data storage format CSV TXT RDB Security Number of user groups 50 Number of user rights 32 Number of users 50 Password export/import SIMATIC Logon Logging through printer Alarms Report (shift log) Hardcopy Electronic print to file Character sets Keyboard fonts US English Page 8/10 24.03.2016 Copyright Siemens AG
Transfer (upload/download) MPI/PROFIBUS DP USB Ethernet Wireless LAN using external storage medium Process coupling S7-1200 S7-1500 S7-200 S7-300/400 LOGO! WinAC SINUMERIK SIMOTION Allen Bradley (EtherNet/IP) Allen Bradley (DF1) Mitsubishi (MC TCP/IP) Mitsubishi (FX) OMRON (FINS TCP) OMRON (LINK/Multilink) Modicon (Modbus TCP/IP) Modicon (Modbus) OPC UA Client OPC UA Server Service tools/configuration aids Backup/Restore manually Backup/Restore automatically Simulation Device switchover Peripherals/Options Peripherals Printer SIMATIC HMI MM memory card: Multi Media Card SIMATIC HMI SD memory card: Secure Digital memory card USB memory Network camera Additional software components loadable ; Backup/restore ; WinAC RTX ; without NC channel ; SIMATIC options Mechanics/material Page 9/10 24.03.2016 Copyright Siemens AG
Enclosure material (front) Plastic Aluminum Stainless steel Dimensions Width of the housing front Height of housing front Weights Weight without packaging Weight incl. packaging 307.5 mm 223.5 mm 1.6 kg 1.7 kg last modified: 23.03.2016 Page 10/10 24.03.2016 Copyright Siemens AG