Product type designation. General information. CiR - Configuration in RUN. Input current. Power loss. Memory

Similar documents
100 ms. 30 µs; Time per I/O byte. 24 V DC No; Power supply via system power supply. Not relevant for 400 series (300 series set)

Product type designation. General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory

Product type designation. General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory

SIMATIC S7-400, CPU KB WORKING MEMORY (384 KB CODE, 384 KB DATA) 1. INTERFACE MPI/DP 12 MBIT/S 2.IF PROFIBUS DP, 3.

General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory

Supply voltage. Input current. Power loss. Memory. Battery. CPU processing times

CPU 412H. Function. Parameterizable properties

CPU 412. Function. Programmable properties

Product type designation. General information. Supply voltage. Input current. Power losses

General information. Supply voltage. Input current

Product type designation. General information. Supply voltage. Input current. Power loss

Programming package STEP 7 V5.2 SP1 or higher with HSP 0126

General information. Supply voltage. Input current

General information. Supply voltage. Input current

General information. Supply voltage. Input current

General information. Supply voltage. Input current

General information. Supply voltage

General information. Engineering with. Supply voltage. Load voltage L+ Input current. Power losses. Memory. Work memory.

CPU 317F-2 DP. Page 1603 Mar 2008 Siemens ITS

Product type designation. General information. Supply voltage

CPU 319F-3 PN/DP. Page 1682 Mar 2008 Siemens ITS

6ES7151-8AB01-0AB0. 5/18/2011 Siemens Industry IA/DT/BT Service&S. siemens.com/ww/llisapi.dll?func=csl 1/10 ET200S, IM151-8 PN/DP CPU, 192 KB

Parameterizable properties The S7 configuration as well as the properties and response of the CPUs can be parameterized using STEP 7:

SIPLUS CPU 313C-2DP. Function

Product type designation. General information. Supply voltage. Input current

64 kbyte ; 64 KB / 21K instructions RAM (integrated) Yes ; 4 KB: bit memory, counter, times and data

General information. Display. Control elements. Supply voltage

General information. Configuration control. Display. Control elements. Supply voltage

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

Product type designation

General information. Configuration control. Display. Control elements. Supply voltage

General information. Configuration control. Control elements. Supply voltage. Input current. Power. Power loss. Memory

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

General information. Display. Control elements. Supply voltage

General information. Display. Control elements. Supply voltage

Product type designation. General information. Supply voltage

SIMATIC PC-based controller

PROFINET/Industrial Ethernet Controllers / Modular controllers / SIMATIC S7-400

SIMATIC. ET 200S IM CPU Interface Module. Introduction. New features 2. Technical specifications 3. Product Information 06/2007 A5E

Data sheet VIPA CPU 214PG (214-2BE03)

Data sheet VIPA CPU 214NET PG (214-2BT13)

Multi Panel options. SIMATIC WinAC MP 2/169

General information. Display. Supply voltage. Input current

Data sheet CPU 315SB/DPM (315-2AG12)

General information. Display. Supply voltage

Data sheet CPU 315SB/DPM (315-2AG12)

Data sheet CPU 315SN/NET (315-4NE12)

Data sheet CPU 315SN/NET (315-4NE12)

Data sheet CC 03, Commander Compact (603-1CC21)

General information. Display. Supply voltage. Input current

General information. Supply voltage

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage

Data sheet CPU 315SN/PN ECO (315-4PN33)

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current

Data sheet CPU 015PN (015-CEFPR01)

Data sheet VIPA CPU M13C (M13-CCF0000)

General information. Display. Supply voltage. Input current

Data sheet CPU 015PN (015-CEFPR00)

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Data sheet VIPA CPU 115DP (115-6BL22)

Data sheet CPU 115 (115-6BL02)

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Data sheet SLIO CPU 015PN (015-CEFPR01)

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Output current. Power loss. Memory

General information. Display. Supply voltage. Input current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

Data sheet CPU 013C (013-CCF0R00)

Supply voltage. Input current. Encoder supply. Memory

Commander compact. Commander compact Lines displays. System SLIO. System 100V. Lines displays Commander compact 603-1CC CC21.

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

SIMATIC NET. S7-CPs for PROFIBUS. CP Extended for PROFIBUS. Manual Part B4

General information Engineering with Programming package. Display with display

Supply voltage. Input current. Encoder supply. Memory SIMATIC S7-200, CPU 221 COMPACT UNIT, DC POWER SUPPLY 6 DI DC/4 DO DC, 4 KB CODE/2 KB DATA,

6ES7212-1BD30-0XB0. permissible range, lower limit (DC) permissible range, upper limit (DC)

General information. Configuration control. Display. Control elements. Supply voltage

CPU 224. The compact high-performance CPU With 24 inputs/outputs on board Expandable with up to 7 expansion modules Design

S7-400, M7-400 Programmable Controllers

CPU 1214C. Overview. Design. The compact CPU 1214C has:

Main Catalog 2012/2013 for specialists in automation and control technology

SIMATIC S /4 Central processing units 4/4 Compact CPUs 4/21 Standard CPUs 4/43 Technology CPUs 4/51 Fail-safe CPUs

SIMATIC. STEP 7 From S5 to S7. Preface, Contents Part 1: Planning Your Conversion. Introduction. Hardware. Software. Part 2: Converting Programs

Central processing units CPU 221, CPU 222, CPU 224, CPU 224 XP, CPU 224 XPsi, CPU 226

SIMATIC S Central processing units

STEP 7. Function. Page 1791 Mar 2008 Siemens ITS

SIMATIC demo6\simatic 300 站点 \CPU 313C 06/22/ :02:45 PM

Transcription:

Data sheet SIMATIC S7-400, CPU 412-2 CENTRAL PROCESSING UNIT WITH: 512 KB WORKING MEMORY, (256 KB CODE, 256 KB DATA), 1. INTERFACE MPI/DP 12 MBIT/S, 2. INTERFACE PROFIBUS DP Product type designation General information Firmware version V5.0 Engineering with Programming package STEP7 V 5.3 SP2 or higher with HW update CiR - Configuration in RUN CiR synchronization time, basic load 100 ms CiR synchronization time, time per I/O byte 200 µs Input current from backplane bus 5 V DC, typ. from backplane bus 5 V DC, max. from backplane bus 24 V DC, max. from interface 5 V DC, max. Power loss Power loss, typ. Memory Type of memory Work memory Integrated integrated (for program) integrated (for data) expandable Load memory 0.9 A 1.1 A 300 ma; 150 ma per DP interface 90 ma; At each DP interface 4 W other 512 kbyte 256 kbyte 256 kbyte No Page 1/11 11.06.2015 Copyright Siemens AG

expandable FEPROM expandable FEPROM, max. integrated RAM, max. expandable RAM expandable RAM, max. Backup present with battery Without battery 64 Mbyte 512 kbyte 64 Mbyte No Battery Backup battery Backup current, typ. 125 µa; Valid up to 40 C Backup current, max. 550 µa; Dealt with in the module data manual with the secondary conditions and the factors of influence Feeding of external backup voltage to CPU 5 to 15 VDC CPU processing times for bit operations, typ. for word operations, typ. for fixed point arithmetic, typ. for floating point arithmetic, typ. 75 ns 75 ns 75 ns 225 ns CPU-blocks DB Number, max. 3 000; Number range: 1 to 16000 Size, max. FB Number, max. 1 500; Number range: 0 to 7999 Size, max. FC Number, max. 1 500; Number range: 0 to 7999 Size, max. OB Number, max. see instruction list Size, max. Number of time alarm OBs 2 Number of delay alarm OBs 2 Number of cyclic interrupt OBs 2 Number of process alarm OBs 2 Number of isochronous mode OBs 2 Number of multicomputing OBs 1 Nesting depth per priority class 24 Page 2/11 11.06.2015 Copyright Siemens AG

additional within an error OB 1 Counters, timers and their retentivity S7 counter Number 2 048 Retentivity can be set lower limit 0 upper limit 2 047 preset Z 0 to Z 7 Counting range lower limit 0 upper limit 999 IEC counter present Type SFB S7 times Number 2 048 Retentivity can be set lower limit 0 upper limit 2 047 preset No times retentive Time range lower limit 10 ms upper limit 9 990 s IEC timer present Type SFB Data areas and their retentivity retentive data area in total Total working and load memory (with backup battery) Flag Number, max. Retentivity available Retentivity preset MB 0 to MB 15 Number of clock memories 8; in 1 memory byte Data blocks Number, max. 3 000; Number range: 1 to 16000 Size, max. Local data adjustable, max. 8 kbyte preset Page 3/11 11.06.2015 Copyright Siemens AG

Address area I/O address area Inputs Outputs of which distributed MPI/DP interface, inputs 2 kbyte MPI/DP interface, outputs 2 kbyte DP interface, inputs DP interface, outputs Process image Inputs, adjustable Outputs, adjustable Inputs, default 128 byte Outputs, default 128 byte consistent data, max. 244 byte Access to consistent data in process image Subprocess images Number of subprocess images, max. 15 Digital channels Inputs 32 768 of which central 32 768 Outputs 32 768 of which central 32 768 Analog channels Inputs 2 048 of which central 2 048 Outputs 2 048 of which central 2 048 Hardware configuration Number of expansion units, max. 21 connectable OPs 31 Multicomputing ; 4 CPUs max. (with UR1 or UR2) Interface modules Number of connectable IMs (total), max. 6 Number of connectable IM 460s, max. 6 Number of connectable IM 463s, max. 4; IM 463-2 Number of DP masters Integrated 2 via IM 467 4 Via CP 10; CP 443-5 Extended Page 4/11 11.06.2015 Copyright Siemens AG

Mixed mode IM + CP permitted No; IM 467 cannot be used with CP 443-5 Ext., IM 467 cannot be used with CP 443-1 EX40 in PROFINET IO mode via interface module 0 Number of pluggable S5 modules (via adapter 6 capsule in central device), max. Number of IO Controllers Via CP Via CP 443-1 EX 41 in PROFINET mode; max. 4 in central controller Number of operable FMs and CPs (recommended) FM Limited by number of slots and number of connections CP, point-to-point Limited by number of slots and number of connections PROFIBUS and Ethernet CPs 14; Of which 10 CP or IM max. as DP master and PROFINET controller Slots required slots 1 Time of day Clock Hardware clock (real-time clock) battery-backed and synchronizable Resolution 1 ms Deviation per day (buffered), max. 1.7 s; Power off Deviation per day (unbuffered) max. 8.6 s; For power On Operating hours counter Number 8 Number/Number range 0 to 7 Range of values 0 to 32767 hours Granularity 1 hour retentive Clock synchronization to MPI, master to MPI, slave to DP, master to DP, slave in AS, master in AS, slave on Ethernet via NTP Via CP Time difference in system when synchronizing via MPI, max. 200 ms Interfaces Number of RS 485 interfaces 2 Number of other interfaces 0 Page 5/11 11.06.2015 Copyright Siemens AG

1. Interface Interface type Integrated Physics RS 485 / PROFIBUS Isolated Power supply to interface (15 to 30 V DC), max. 150 ma Number of connection resources MPI: 32, DP: 16 Functionality MPI DP master DP slave MPI Number of connections 32 Transmission rate, max. 12 Mbit/s Services PG/OP communication Routing Global data communication S7 basic communication S7 communication DP master Number of connections, max. 16 Transmission rate, max. 12 Mbit/s Number of DP slaves, max. 32 Services PG/OP communication Routing S7 basic communication S7 communication Equidistance mode support SYNC/FREEZE Activation/deactivation of DP slaves Direct data exchange (slave-to-slave communication) Address area Inputs, max. 2 kbyte Outputs, max. 2 kbyte User data per DP slave User data per DP slave, max. 244 byte Inputs, max. 244 byte Outputs, max. 244 byte Slots, max. 244 Page 6/11 11.06.2015 Copyright Siemens AG

per slot, max. 128 byte DP slave Number of connections 16 GSD file http://support.automation.siemens.com/ww/view/en/113652 Transmission rate, max. 12 Mbit/s Address area, max. 32 User data per address area, max. 32 byte User data per address area, of which 32 byte consistent, max. Services PG/OP communication Routing Transfer memory Inputs 244 byte Outputs 244 byte 2. Interface Interface type Integrated Physics RS 485 / PROFIBUS Isolated Power supply to interface (15 to 30 V DC), max. 150 ma Number of connection resources 16 Functionality DP master DP slave DP master Number of connections, max. 16 Transmission rate, max. 12 Mbit/s Number of DP slaves, max. 64 Services PG/OP communication Routing Global data communication No S7 basic communication S7 communication Equidistance mode support SYNC/FREEZE Activation/deactivation of DP slaves Direct data exchange (slave-to-slave communication) Address area Inputs, max. Page 7/11 11.06.2015 Copyright Siemens AG

Outputs, max. User data per DP slave User data per DP slave, max. 244 byte Inputs, max. 244 byte Outputs, max. 244 byte Slots, max. 244 per slot, max. 128 byte DP slave Number of connections 16 GSD file http://support.automation.siemens.com/ww/view/en/113652 Transmission rate, max. 12 Mbit/s Address area, max. 32 User data per address area, max. 32 byte User data per address area, of which 32 byte consistent, max. Services Routing Transfer memory Inputs 244 byte Outputs 244 byte Isochronous mode Isochronous operation (application synchronized up to terminal) User data per isochronous slave, max. 244 byte Equidistance shortest clock pulse 1.5 ms; 0.5 ms without use of SFC 126, 127 max. cycle 32 ms Communication functions PG/OP communication Number of connectable OPs without message 31 processing Number of connectable OPs with message 31; When using alarm_s and alarm_d processing Global data communication Number of GD loops, max. 8 Number of GD packets, transmitter, max. 8 Number of GD packets, receiver, max. 16 Size of GD packets, max. 54 byte Size of GD packet (of which consistent), max. 1 variable S7 basic communication Page 8/11 11.06.2015 Copyright Siemens AG

User data per job, max. 76 byte User data per job (of which consistent), max. 1 variable S7 communication User data per job, max. User data per job (of which consistent), max. 462 byte; 1 variable S5 compatible communication ; (via CP max. 10 and FC AG_SEND and FC AG_RECV) User data per job, max. 8 kbyte User data per job (of which consistent), max. 240 byte Number of simultaneous AG-SEND/AG-RECV 24/24 orders per CPU, max. Standard communication (FMS) ; Via CP and loadable FB Open IE communication ISO-on-TCP (RFC1006) Via CP 443-1 Adv. and loadable FB Data length, max. 1452 Web server No; Via CP Number of connections overall 32 usable for PG communication reserved for PG communication 1 usable for OP communication reserved for OP communication 1 S7 message functions Number of login stations for message functions, max. 31; Max. 31 with alarm_s and alarm_d (OP's); max. 8 with alarm_8 and alarm_p (e.g. WinCC) Symbol-related messages Block related messages simultaneously active Alarm-S blocks, max. 70 Alarm 8-blocks Number of instances for alarm 8 and S7 300 communication blocks, max. preset, max. 150 Process control messages Number of archives that can log on simultaneously 4 (SFB 37 AR_SEND) Number of messages overall, max. 512 in 100 ms grid, max. 0 in 500 ms grid, max. 256 Page 9/11 11.06.2015 Copyright Siemens AG

in 1000 ms grid, max. 256 Number of additional values with 100 ms grid, max. 0 with 500, 1000 ms grid, max. 1 Test commissioning functions Status block Single step Number of breakpoints 4 Status/control Status/control variable Variables Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters Number of variables, max. 70 Forcing Forcing Forcing, variables Inputs/outputs, bit memories, distributed I/Os Number of variables, max. 64 Diagnostic buffer present Number of entries, max. 400 can be set preset 120 Programming Command set see instruction list Nesting levels 7 Access to consistent data in process image System functions (SFC) see instruction list System function blocks (SFB) see instruction list Programming language LAD FBD STL SCL CFC GRAPH HiGraph Number of simultaneously active SFCs DPSYC_FR 2 D_ACT_DP 4 RD_REC 8 WR_REC 8 Page 10/11 11.06.2015 Copyright Siemens AG

WR_PARM 8 PARM_MOD 1 WR_DPARM 2 DPNRM_DG 8 RDSYSST 8 DP_TOPOL 1 Number of simultaneously active SFBs RDREC 8 WRREC 8 Know-how protection User program protection/password protection Dimensions Width Height Depth Weights Weight, approx. 25 mm 290 mm 219 mm 720 g last modified: 10.06.2015 Page 11/11 11.06.2015 Copyright Siemens AG