with Fiber Management Bar

Similar documents
Wall Mounted Building Entrance Enclosure Instructions

SYSTIMAX 360 ipatch 96F LC Upgrade Kit

SYSTIMAX 360 ipatch Network Manager Module Faceplate Instructions

SD Splicing Cassette

imvision Controller Programming of ipatch 96F-LC and 32-MPO Shelves and Panels Instructions

3 Angled Connector Housing (MC) Installation

SYSTIMAX imvision impower Power Extender Installation

Pretium Rack-mountable 1U Housing Hardware

Mini Wall-mount Building Terminal (WBM)

HD Flex Zero RU Cassette Holder and Bracket

ONE SD-LAN Wall Mount Splitter Housing (1LAN-SPLT C)

SYSTIMAX 360 Evolve Modular Panel Installation Instructions

SYSTIMAX 360 PATCHMAX Modular Panel Instructions

Rack Installation Instructions

SYSTIMAX GS3 and 1100GS6 Evolve Modular Panel Instructions

AMP NETCONNECT* Gen II Vertical Storage Area Management (SAM) System

HP EVA4400 M6412 drive enclosure

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

System Storage EXP3000 Rack Installation Instructions

Dell Networking S4100-ON Series. Set-Up Guide

CommScope and Cisco - The ideal connectivity system for multilayer directors

Rack Installation Instructions

FreeNAS Mini and Mini XL Network Upgrade Kit

M204SMB Surface Mount Box Instructions

S5048F-ON. Set-up Guide

G12/G12x USER S MANUAL

Removing and Replacing Parts

Fiber Management Tray (FMT) User Manual

Gateway Profile 4 service guide

5000, 7000 Series StorSimple Appliance. Rack Installation Guide

Installing the Cisco SFS 3504 Server Switch

Optical Line Splitter Installation Instructions

TABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION

OCM5 Splitters and Pass-Through Modules for CSX-3 Cabinets

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

Next Generation Frame Fiber Termination Block With MPO Connectors (FTB w/mpo) User Manual

Thermal Transfer Option Rev.C

IBM. Rack Installation Instructions

Model 2380 Rack-Mount Kit

Print Mechanism Maintenance Kit

Installing the Cisco MDS 9020 Fabric Switch

CommScope standard density fiber optic panels. High-performance communication solutions

Installing the ASA 5550

NG3 High-Density Fiber Distribution Frame System Termination, Termination/Splice, VAM, and MPO Panels

MULTI-MOUNT. Assembly Manual

Table of Contents Chapter 3 Installing the Switch

Model 2380 Rack-Mount Kit

Customer Replacement Procedure

Series 3700 Screw Terminal Assemblies Installation Instructions

FiberExpress Brilliance Connectors

OFS 300 Optical Fiber Scope User s Guide

3M Fibrlok II Angle Fiber Splice 2529-AS 3M Fibrlok 250 µm Angle Fiber Splice 2540-AS

Pretium EDGE Tap Module Installation and Testing

VEP4600. Setup Guide

CSS1 Contractor Series Light Sources and CSM1 Contractor Series Optical Power Meters User s Guide

High Density PEACOC v. 3.0 Fiber Patch Panel& FleT

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

S4112-ON Series. Setup Guide

Installation Guide Philips MP20/30/40/50/60/70 IntelliVue M-Series Arm Rail Mount Kit

MASTERLINE Ultimate Hybrid High Voltage 4/12 (MLUH HV 4/12) blunt cut at BTS side

2U, 4U, and 7U Systems

HD40H(X) Performance Series Camera. User Guide

PM-212-SI3 Pocket Optical Power Meter INSTRUCTION MANUAL

Dell Latitude C800 Service Manual

DCS200/DCS200-09/DCS DCS300/DCS300-09/DCS355

Full HD IP Vandal Dome Camera

Tower to Rack and Rack to Tower System Conversion Guide

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

Multi-Mount for Mac Pro " to 5.25" Drive Bay Converter Bracket. Assembly & Installation Manual

Survival Laser SL-001.4PB Laser Parts Bundle Assembly & Operation Instructions

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Cable Routing Procedures for Dell PowerEdge R630 Systems

OPERATOR MANUAL. OSD2053P SERIES MICRO 10/100Base-T to 100Base-X MEDIA CONVERTER. WITH PoE SOURCE

Sheath Removal of 3456-Fiber RocketRibbon Extreme-Density Cable

Customer Upgrade Procedure

User Manual. Revision B

Distribution Module Cat 5E Panels

PM-212-MPO Pocket Optical Power Meter INSTRUCTION MANUAL

and Network Interface Modules Installation Instructions

Ruger SR22. Operator s Manual RUGER SR22 SR9C SR40C 9E LMS-RMSR

Encore XT Manual Gun Upgrade Kit

Rack Installation Instructions

CNK600 Cable-Nook Interconnect Box

Peel & Present Option Rev.C

ReadyTM Fiber Solution

8~14-Port Managed Ethernet Switch

Mounting on the Ceiling Using Flush Mount (Face Down)

Charging Cabinet Owner s Manual

System Storage DS3950 Quick Start Guide

TM-SERIES TABLE MOUNTING BRACKETS USER S GUIDE

Dell OptiPlex All-in-One. Stand Installation Guide

SYSTIMAX Rack and Cabinet Solution

PowerFlex 700S Phase II Drives DriveLogix Option Card Battery Extension Cable

Connect Router to the Network

Survival Laser SL-VPB Laser Parts Bundle Assembly & Operation Instructions

Crimplok ST* and SC Non-Adhesive Fiber Optic Single & Multi-mode Connectors

Installation Manual. Table of Contents

BPL SERIES INSTALLATION INSTRUCTIONS THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

Transcription:

Issue 1, June 2014 SYSTIMAX 1100A Angled Fiber Termination Panel with Fiber Management Bar General The SYSTIMAX 1100A angled fiber termination panel is a 19 wide x 1.75 high (483mm x 44mm) 1U panel designed to accept 360 InstaPATCH Plus modules and a variety of available MPO adapters and blank panels. The angular panel configuration matches that of SYSTIMAX copper panel offerings. The panel is ipatch ready and is intended for indoor use or can be used outdoors in a suitable protective enclosure. Ordering information is listed below: Material ID Part No. Description 760198614 1100A-FIBER-IPR-1U 1100A angled fiber termination panel How to Contact Us SYSTIMAX 1100A Angled Fiber Termination Panel To find out more about CommScope products, visit us on the web at / For technical assistance: - Within the United States, contact your local account representative or technical support at 1-800-344-0223. Outside the United States, contact your local account representative or PartnerPRO Network Partner. - Within the United States, report any missing/damaged parts or any other issues to CommScope Customer Claims at 1-866-539-2795 or email to claims@commscope.com. Outside the United States, contact your local account representative or PartnerPRO Network Partner. Tools Required Philips screwdriver 2014 CommScope, Inc. All rights reserved Page 1 of 6

Optional Tools Fiber optic connector cleaning and inspection kit (760053199) Fiber optic connector cleaning and inspection consumables (760053207) Parts List Verify parts against the parts list below: Quantity 1 1U angled panel Description 1 Fiber management bar with brackets 1 Retainer kit 4 Fiber routing clips 4 #12-24 x 1/2 screws (for 19 and 23 rack/cabinet mounting) 4 M6 x 12 screws (for ETSI rack/cabinet mounting) 1 Instruction sheet Related Components for 1100A Angled Panel Ordering information for available accessories is listed below. Material ID Product No. Description 760032102 MODG2-BLANK G2 modular blank panel bezel (package of 4) 760032110 MODG2-MGS G2 modular MGS bezel (package of 4) 760039875 G2-SRF Liquid-tight cable fitting kit for small-diameter cables 760039883 G2-23BRKT Frame mounting bracket kit for 23 frames and ETSI frames 760107482 DP360-BLANK 360 InstaPATCH blank panel (package of 4) 760107490 DP360-2MPO 360 InstaPATCH 2 MPO adapter panel 760107508 DP360-4MPO 360 InstaPATCH 4 MPO adapter panel 760107516 DP360-6MPO 360 InstaPATCH 6 MPO adapter panel 760107524 DP360-8MPO 360 InstaPATCH 8 MPO adapter panel 760058677 RMB-6-1/2 InstaPATCH Plus attachment bracket, rack mounted, 6 1/2" fittings 760058685 RMB-6-3/8 InstaPATCH Plus attachment bracket, rack mounted, 6 3/8" fittings Note: Contact your SYSTIMAX sales representative for more information on a wide variety of modules, panels, trunk cables and accessories that are compatible with these panels. Precautions 360 InstaPATCH Plus modules contain fiber optic cable and passive optical components. When removed from protective packing, they should be handled carefully and installed in appropriate racks for mechanical support and protection. 360 InstaPATCH Plus modules require virtually no maintenance to maintain their performance. They contain no user-serviceable components, and any damage to the anti-tamper label or removal of top cover or front adapter mounting panel will void the warranty. Fiber optic trunk cable and jumper performance is sensitive to bending, pulling, and crushing. Minimum bend radius must be maintained during installation per the manufacturer s specification. Appropriate pulling grips must be used during installation, and pulling forces shall not exceed manufacturer s recommendations. Use caution to avoid kinking trunk cables. Care should be taken not to compromise the stability of the rack by installation of this equipment. To be installed in restricted access areas only. Page 2 of 6

860574433 CAUTIONS Isopropyl Alcohol is flammable, and can cause eye irritation on contact. If eye contact occurs, flush with water for at least 15 minutes. In case of ingestion, consult a physician. Use only in well ventilated areas. Disconnected optical components may emit invisible optical radiation that can damage your eyes. Never look directly into an optical component that may have a laser coupled to it. Serious and permanent retinal damage is possible. If accidental exposure to laser radiation is suspected, consult a physician for an eye examination. Wearing safety glasses during installation of this panel is recommended. Although standard safety glasses provide no protection from potential optical radiation, they offer protection from accidental airborne hardware and cleaning solvents. Connector Cleaning 360 InstaPATCH Plus modules are pre-terminated, with either protective dust caps (SC) or integral hinged shutters (LC) installed on all adapters. Connectors internal to the adapters are clean when purchased. Clean trunk cable and jumper connectors per manufacturer s recommendations prior to connection to the panel. If trunk cables or jumpers are removed, replace provided dust caps (SC) on the adapters to protect the internal connectors. Step 1 Mount Panel to Equipment Rack 1. Determine the rack/cabinet size and desired mounting location. For 19-inch rack (as shown) Mount panel to equipment rails using four #12-24 screws provided. For 23-inch rack Use the G2-23BRKT accessory kit (available separately) and install two conversion brackets to the panel mounting flanges, using the four #10-32 x 3/8 conversion screws included in the accessory kit. One conversion bracket and two screws per side. Mount the panel to the equipment rails using four #12-24 x 3/8 screws (provided with panel). For ETSI rack Use the G2-23BRKT accessory kit (available separately) and install one conversion bracket to either of the panel mounting flanges, using two of the four #10-32 x 3/8 conversion screws included in the accessory kit. The panel will not be centered when mounted in the rack. Mount the panel to the rack using four M6 x 12 mm screws (provided with panel). Page 3 of 6

Step 2 Mount Fiber Management Bar to Equipment Rails 1. After panel is installed onto equipment rails, locate bar retention brackets on opposite flange of equipment rail and loosely secure them in place with two 12-24 screws each. Note: Position brackets so they are located on the same U increment as the panel. 3. Slide bar into brackets until it contacts the back side of the panel. 4. Fully tighten four 12-24 screws to secure bar in position. Note: To use the fiber management system in a cabinet or rack using an L-shaped rail as opposed to a channel shaped rail, a hardware kit (760110098) is provided. Assembly is shown in the bottom figure. Page 4 of 6

860574433 Step 3 Install Modules 1. Remove blank covers from panel openings at desired locations. 2. Position module in ALPHA or BETA orientation as required and slide into opening in panel until latches engage with an audible click. 3. Repeat for remaining positions. Step 4 Install and Route Trunk Cables 1. Terminate MPO connectors into modules. 2. Slip fiber routing clips over fiber management bar approximately where required. 3. Spread open a slot position provided on fiber routing clip and secure fiber cable inside. 4. Repeat until all cables are secured and adjust position of clips as required for a smooth routing. Note: It is recommended to begin routing fiber cables from the module nearest the side of planned fiber exit and work toward module furthest away. Page 5 of 6

Step 5 Install Labels 1. Affix labels to front surface of panel as shown above. Note: Position labels over modules on right side of panel and under modules on left side of panel. 2. Labels included with modules may be used or printable label templates are available on the CommScope website, which can be used along with available label stock to create finished port numbering labels. Note: To print a designation label, go to http:///resources/labeling-templates and scroll down to the 360G2 Panels and Shelves and select the appropriate label template. Page 6 of 6