SSP 301 Z-Wave Switch and Repeater

Similar documents
SES 302 and SES 303 Temperature & Humidity Sensor. User and Installation Instructions BGX

SSR 303 One Channel 3 Amp Switch (Rx Only) - Z-Wave. User and Installation Instructions

Wireless Lighting Control ZRM-M80 Z-Wave Smart Plug (with switch and energy meter) USER MANUAL

Adding to Z-Wave TM Network 1

Quick start Energy Switch EU

PACKAGE CONTENTS SPECIFICATIONS

Features. ! Single vector/bi vector/tri vector measurement! Time of day metering with maximum demand registration

2. Press Fn switch 3 times in a row again to exclude the device from Z-Wave network.

POP_ Z-Wave Schuko Plug-in Switch plus Power Meter Firmware Version : 1.1

Instruction Manual Power plug Model number: STW-W3350WU

Please refer to the chapters below for detailed information about all aspects of the products usage.

F O R E S T S H U T T L E S / L Z - W

Motion Sensor 2 with temperature sensor

AEO_SES3_EU Inline Smart Energy Switch. Quick Start. What is Z-Wave? Product description. Before Device is installed

Please refer to the chapters below for detailed information about all aspects of the products usage.

PRODUCT DESCRIPTION PACKAGE CONTENTS

Z-Wave AC Motor Shutter Controller

Z-Wave Dimmable LED Light Bulb

Flood Sensor. Product Description. Prepare for Installation / Reset Please read the user manual before installing the product.

Aeon Labs Nano Switch

PowerNodes NP160-F NP162-F

PHI_PAN06 Relay Insert 2 * 1.5 KW

DUW_ Wall Switch Set for Design Duwi Everlux Firmware Version : 1.0

Adding to Z-Wave TM Network

HEATIT Z-DIN 616. DIN-rail module. Installation- and user manual

PAN11. Smart energy plug in switch

AXIS T8341 PIR Motion Sensor. User Manual

PAN11-1B Smart energy plug in switch

Communication over Modbus protocol Connection with multiple controllers Application upgrade by using an SD 1) card or a USB stick

MCO Home Glass Touch Switch GEN5 (2 Buttons)

HRT4-ZW THERMOSTAT MANUAL Z-WAVE INFORMATION

Please refer to the chapters below for detailed information about all aspects of the products usage.

Aeon Labs Smart Switch 6 (Z-Wave Smart Switch 6)

WALL MOUNTED SWITCH MANUAL

Universal Z-Wave Key Pad

PAD02. Z-Wave Smart Dimmer Socket. Adding to Z- Wave TM Network

ERF910. RF Repeater. Synco living

POPE Z-Wave 10 Year Smoke Detector with Siren Function

PACKAGE CONTENTS SPECIFICATIONS PRODUCT DIAGRAM

PRODUCT DIAGRAM PACKAGE CONTENTS

CO2 Controller Operating Instructions Models: RAD-0501, RAD-0501A, RAD-0501E 1. Product Description

Instruction Manual. T3110 T3110L T3110Ex

Z-Wave CO Detector. Product Description. Prepare for Installation / Reset Please read the user manual before installing the product.

A11 User s Manual (ZigBee Wireless Smart Plug) Ver. 1.04

Cashpower Three Phas e

TP5000 Si Range Electronic 5/2 day programmable room thermostat Mains, Battery and RF versions Installation and User Instructions

Nano Shutter is also a security Z-Wave plus device and supports Over The Air (OTA) feature for the products firmware upgrade.

Wall Controller WALLC

Operating Instructions

I-RK01 Radio Keypad. Installation Guide. 2 abc. 3 def. 4 ghi. 6 mno. 5 jkl. 8 tuv 9 wxyz. 7 pqrs

ZXT-310 (Z-Wave-to-AV IR Extender)

PRODUCT DESCRIPTION PACKAGE CONTENTS

Operating Instructions

MULTIREG Z-WAVE SCENE CONTROLLER

Universal Z-Wave Key Pad

Aeon Labs Dual Nano Switch

AEO_HDS Heavy Duty Switch

Aeon Labs Nano Dimmer

RF adapter plugs, dimming

LoRaWAN Pressure / Depth and Temperature Sensor

Rain Sensor. Quickstart. What is Z-Wave? Product Description. Prepare for Installation / Reset. Installation

Wireless Lighting Control. On/Off. Outdoor Module.

Rain Sensor SKU: POPE700168

Home Automation Gateway HA102

HomePro ZRF113. Z-Wave Radio Frequency (RF) Controlled, 120 VAC, Isolated Contact Fixture Module, Series 200, Release 2.2

LoRaWAN Pressure / Level and Temperature Sensor

QSW16M 16 Chn PoE managed switch

Bosch Smart Home. Plug Instruction Manual

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

Adding to Z-Wave TM Network

Type MVTT 14 and MVTT 15: Static Digital Time delay relays

PowerNodes User Guide

Neutrik 20A powercon with 2nd order EMI filter & GDT/VDR protection circuit against Lightning Strike & Local Power Surge Circuit A

Reyrolle Protection Devices. 7SG117 Argus 7 Synchronising Relay. Answers for energy

PRODUCT DIAGRAM PACKAGE CONTENTS

Home automation hub installation and setup guide

ZONETOUCH DAMPER CONTROL SYSTEM Operation Manual

PowerLINE 1000, 1010 and 1200 Adapters

LED Driver. LED Driver. LED Driver

HomePro ZDP100. Radio Frequency Controlled, 300W, 120 VAC, Plug-In Lamp Module, Release 2.0 ZDP100 PLUG-IN LAMP MODULE INSTALLATION

LED Bulb Manual. Familiarize yourself with your LED Bulb.

PAN03 ; PAN10 Switch Module with meter

GETTING STARTED WITH SWITCHEE

USER MANUAL DHP-P500AV/DHP-P501AV VERSION 1.2

GETTING STARTED WITH SWITCHEE

Operating Instructions

Aeon Labs Doorbell Gen5 (Z Wave Doorbell Gen5)

Version /25/2014. User Manual. PowerLine AV 500 Passthrough Mini Adapter DHP P308AV / DHP-P309AV

Aeon Labs Dual Nano Switch

ZME_WCD2 Z-Wave Double Paddle Wall Controller DURO white

User Manual. For more information, visit

smanos K2 Smart Hub Contents

RCD Fused Connection Unit Model: RCD10WPV. RCD Double Sockets Models: RCD05WAV, RCD06WPV, RCD07MAV, RCD08MPV. Installation & Operating Instructions

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

Z-Wave to Systemair HVAC Adapter

User Guide. Video Borescope. Models BR200 and BR250

PAT-Cal 2 TECHNICAL MANUAL

TZ75 Roller shutter controller

Aeon Labs Range Extender 6. (Z-Wave Range Extender)

Pro. LCN1840/05 Wireless gateway. Specification sheet. Connected lighting. Find out more about Interact

Transcription:

SSP 301 Z-Wave Switch and Repeater User and Installation Instructions BGX501-920-R03 1

SSP 301 The Secure SSP 301 is a switch and repeater that forms part of a Z-Wave Plus home automation network. The SSP 301 is a mainspowered device that will switch (power On/Off) a connected appliance either by the Z-Wave network or manually by pressing its integrated button. Z-Wave Controller out of range controller cannot communicate directly with device SSP Repeater Lamp Load The SSP 301 acts as a repeater in a Z-Wave network by helping messages from other devices reach there destinations. 2

The SSP 301 is a fully compliant Z-Wave Plus device that will work with other manufacturer's Z-Wave devices. Installation Step 1: Unpack, and insert the SSP 301 into the wall socket. Ensure that the redcoloured network status LED is flashing (once per second). Note: If the network status LED is not flashing check the following. Ÿ Button Ensure that the wall socket switch is on. Ÿ Press the top button, the relay status LED should switch ON and glow green. Ÿ If the relay status LED does not glow then the device is not functioning. Relay Status LED 3

Ÿ It is possible that the SSP 301 was part (joined) of another network previously; if so, exclude it first before attempting to include onto a new netwrok. Refer to step-2 for the exclusion process. Ÿ Avoid locations alongside or behind large metal surfaces that could interfere with the low power radio signals between the unit and the controller. Step 2: Including and Excluding a Device To include the SSP 301 onto a network, put the controller into inclusion mode. Now, press and hold the button on SSP 301 for 4 to 7 seconds t h e n r e l e a s e. T h e network status LED will start flashing (twice per second) on successful s t a r t o f i n c l u s i o n process. Note: Inclusion means add and exclusion means delete. Relay Status LED Relay Status LED 4

Note: Refer to the controller's manual for controller relevant actions. On successful inclusion the LED will turn off. The total process can take up to 20 seconds (Refer to the Technical specifications Radio section for details). If the device fails to join the network it will go back to the factory default state and the Network status LED will start flashing once per second. If there is an issue with RF communication, re-locate the device and repeat the inclusion process. To exclude the SSP 301 from a network, put the controller into exclusion mode (refer to controller instructions) and follow the same sequence as per the inclusion process for include node. After successful exclusion the network status LED will start flashing once per second, and the device will reset to factory default. 5

If exclusion fails, the SSP 301 network status LED will turn off after about 5 seconds. Note: Exclusion only works when the device is in direct range of the controller (no repeater allowed) Associating SSP 301 in a Z-Wave Network (follow step 3 to 5) Note: Association process only works after the device has been included onto network Step 3: Put the controller into Association Mode. Note: Some controllers can automatically associate. Always check with the manufacturer's manual. Step 4: Identify the device to the controller by sending the node information, to do this press and hold the SSP 301 button for more than 1 second, but less than 4 seconds, and then release. Step 5: The controller should confirm association when the process is successfully completed this depends on your controller see the manufacturers documentation supplied with your controller for this information. 6

Appliance Socket Press the SSP 301 button (less than one second) to supply power to its socket. By default, the green LED will be lit when the supply is On. The socket type will vary with country. The figure shows the UK variant. Ensure that the appliance plug is firmly plugged into the appliance socket. Combined Button & LEDs Relay Status LED *Socket type will vary with country Relay Status LED: ON power switched to front socket 7

Button Actions Button press time Less than 1 second 1-4 seconds Operation Toggles supply to socket outlet Send NIF (used for Association) LED status Toggles green LED NA 4-7 seconds 7-11 Seconds Inclusion/exclusion SSP 301 resets to factory default (Refer 'Device Reset Locally' command class) Red LED flashes twice per second Red LED flashes once per second 8

Z-Wave Plus command classes Z-Wave Plus Device Classes Generic Specific Basic Command Class Implemented Device Class Binary Switch On/OFF Power Switch Routing Slave Commands Supported Basic (V1) Get Set Report Mapped on Binary Switch Command class (V1) Binary switch (V1) Get Set Report Manufacturer Specific (V2) Get Report Manufacturer ID = 0x0059 Product Type ID = 0x000E Product ID = 0x0001 (UK & EU) Product ID = 0x0002 (ANZ) 9

Version (V2) Association (V2) Get Report Version Command Class Get Version Command Class Report Set Get Report Remove Supported Groupings Get Supported Groupings Report Specific Group Get Command Specific Group Report Command Product supports one association group that have maximum of 4 nodes. Configuration (V1) Set Get Report See Configuration Parameters for details Device Reset Locally (V1) Report Please use this procedure only when the primary controller is missing or otherwise inoperable, 10

Power cycle the device, press and hold the button for 7-11 seconds within the 60 seconds of power cycle to put the device in factory default. It reset all configuration and association to factory default. It also removes the device from Z-Wave network. Association Group Info (V1) Group Name Get Group Name Report Group Info get Group Info Report Group Command List Get Group Command List Report Only one association group is supported and its name is Lifeline Profile MSB - ASSOCIATION_GROUP_INFO_REPORT_PROFILE_ GENERAL Profile LSB - ASSOCIATION_GROUP_INFO_REPORT_PROFILE_ GENERAL_NA Supported Command class and command : Command Class - COMMAND_CLASS_SWITCH_BINARY, Command - SWITCH_BINARY_REPORT 11

Z-Wave Plus Info (V2) Get Report Role Type - ZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SLAVE_ ALWAYS_ON Node Type - ZWAVEPLUS_INFO_REPORT_NODE_TYPE_ZWAVE PLUS_NODE Installer Icon- ICON_TYPE_GENERIC_ON_OFF_POWER_SWITCH User Icon- ICON_TYPE_GENERIC_ON_OFF_POWER_SWITCH Power Level (V1) Power Level Set Power Level Get Power Level Report Power Level Test Node Set Power Level Test Node Get Power Level Test Node Report Note: For more information about Z-Wave command classes and their use refer to SDS12652 Z-Wave command Class Specification version 3 or above and SDS12657 Z-Wave Command Class Specification version 2 or above. 12

Configuration Parameters 1 to 3 N Type 1 Delta based switch Status reporting Unit Size Bytes Max Value NA 1 1 Factory Default Value 2 Time interval Sec. 2 65520 0 based Switch Status Reporting Controllers may only allow configuring signed values. In order to set values in the range 32768 65520, the value sent in the application shall be equal to desired value minus 65520. For example, to set time interval to 36000 seconds it may be needed to set a value 36000 65536= 29536. 3 Relay & LED configuration NA 1 3 0 Refer Table Relay and green LED configuration for details. Common attributes: Ÿ Minimum Value is zero for above parameters. Ÿ Zero configuration mean corresponding functionality is disabled. Ÿ Value set more than maximum allowable limit will be rejected silently, and SSP 301 will retain it last configuration value. Important: When any configuration is set, then it shall be recommended that user should read back and verify that has been set correctly. 1 13

Relay and green LED configuration Config Value Relay Status LED Status After Power Cycle 0 Open ON for Relay Close 1 Retain last status over the power cycle OFF for Relay Open ON for Relay Close OFF for Relay Open 2 Open ON for Relay Open 3 Retain last status over the power cycle OFF for Relay Close ON for Relay Open OFF for Relay Close SSP 301 is shipped with zero default relay LED configuration 14

Visual Indication of a Communication Failure The SSP 301 can indicate a communication failure state to the end user in the following situation: if the SSP 301 is configured with TIME-INTERVAL based data reporting (Configuration parameters #2) and at least one node is associated to it. In that situation, if there is no Communication Acknowledge with any associated device in the network for more than one hour the device will indicate a communication fail status. The communication fail status will be represented on the device by the continuous glowing of the network status LED. When the device establishes communication with any associated node in the network it will come out of the communication fail state. 15

Technical specifications Electrical Purpose of control: Electrical control Supply: 230V±10% AC, 50Hz Current rating (load): Resistive Inductive UK: 13 A 0.4 3 A EU: 16 A 0.4 3 A ANZ: 10 A 0.4 3 A Control type: Micro-disconnection Control action: Type 1B Software class: Class A Burden: <1W in standby Mechanical Dimensions (WxDxH): UK: 60 x 61 x 119mm EU: 60 x 95 x 119mm ANZ: 60 x 69 x 119mm Product weight with single unit packing: Case material: UK: 250 ± 30 g EU: 340 ± 30 g ANZ: 240 ± 30 g Thermoplastic, flame retardant 16

After Care: Clean only with a clean damp cloth - do not use any aggressive cleaning agents. If cleaning agents are necessary, check compatibility before use. Mounting: UK: Type G EU: Schuko Type E & Type F ANZ: Type I Ball Pressure Test Temperature: 75 C Environmental Impulse voltage rating:cat II 2500V Storage temperature: -20 C to 55 C Operating temperature: 0 C to 40 C Environmental humidity range: 0%RH to 95%RH Atmospheric range: 980hPa to 1035hPa Pollution degree: Degree 2 Enclosure protection: IP30 17

Radio RF frequency Europe & UK: 868.42MHz ANZ: 921.42MHz RF range: 100m line of sight in open air Class: 3 Inclusion: If the Z-Wave controller does not respond within 2-seconds then the SSP 301 will try with NWI (Network Wide Inclusion). The total process can take up to 20 seconds. This is a Z-Wave certified product and can be used with Z-Wave controllers that support its functionality. Please refer to the documentation provided by the gateway or controller manufacturer. See the Z-Wave alliance website www.z-wavealliance.org for certified controllers. Compliance ROHS EN 60730-1 R&TTE directive BS 1363-3 (for UK) IEC 60884-1 (for EU) ETSI EN 300 220-2, EN 301 489 part 1 & 3 AS/NZS 3122 and RCM ACMA (for ANZ) 18

European Head Office Secure Controls (UK) Ltd. South Bristol Business Park Roman Farm Road Bristol, BS4 1UP, UK e: info@securetogether.com www.securetogether.com European Sales Office CEWE Instrument AB Box 1006, 611 31 Nyköping t: +46 8 600 80 60 e: info@securetogether.com www.securetogether.com Australia Sales Office Secure Australasia Pty Ltd 258 Darebin Road Fairfield VIC 3078 Australia p: +61 3 9485 6000 f: +61 3 9485 6099 e: info@securetogether.com www.securetogether.com 19

Secure Meters Ltd Pratap Nagar Industrial Area Udaipur 313003 India p: +91 294 2492 300-05 f: +91 294 2492 310 e: mktg@securetogether.com www.securetogether.com Elegant Metering Solutions FZE 4EA 326, P.O. Box 54857 Dubai Airport Free Zone Dubai, UAE p: +971 50 6575166 f: +971 04 204 5619 e: emsfze@emsdxb.ae www.securetogether.com 20