APC Smart-UPS Available Units We re waiting for your call or email. 800--440 uptime@uptime4u.com Tower Series (40 5000 VA) Rack Mount Series (750 5000 VA) 08 Volt Series (000 5000 VA) Extended Runtime (750 5000 VA)
Smart-UPS Tower Series Superior design, high-volume manufacturing and continuous quality enhancement give the APC Smart-UPS line unsurpassed reliability. Award-winning APC Smart-UPS towers are an ideal UPS for protecting business-critical fileservers (Intel or UNIX based), minicomputers, network switches and hubs, point of sale, retail/bank back office and ATMs. Specifications for Smart-UPS Model: 40 60 700 000 500 00 3000 5000 Part # SU40NET SU60NET SU700NET SUA000 SUA500 SU00NET SU3000NET SU5000TXFMR SU40 and SU60 also offer built-in data-line protection for RJ- and 0BaseT ethernet protection. Support for Windows NT/000/XP, Windows Server 003, Novell NetWare, SCO UnixWare, Solaris and Linux. Additional management platform integration plug-ins and application shutdown utilities available for download at www.apc.com/tools/download/. Input Line, 6 ft. line cord NEMA 5-5P NEMA 5-0P NEMA L5-30P NEMA L6-30P Output Receptacles 4 NEMA 5-5R 8 NEMA 5-5R NEMA L6-0R 4 NEMA 5-5R Communication Ports Serial Serial & USB Serial Number of SmartSlot bays n/a, ind. mgmt. card Maximum Dimensions (HxWxD)(in.) 6.6x4.7x4.5 6.x5.4x4. 8.5x6.7x7.3 7 x 7.7 x.5 0.8x7.5x6. Net Weight (lbs.) 7 9 4 53 3 35 Shipping Weight (lbs.) 4 9 3 46 58 34 4 360 Replacement Battery Cartridge RBC RBC 4 RBC 5 RBC 6 RBC 7 RBC RBC Two RBC Service Level SB- SB- SB-3 SB-4 OPERATION SU40NET SU60NET SU700NET SUA000 SUA500 SU00NET SU3000NET SU5000TXFMR Nominal Input Voltage 0 Vac, single phase, 50 or 60 Hz (auto-selectable) 08VAC (50-60 Hz) milliseconds, includes detection time AVR Boost/AVR Trim 30% / % % / % 30% / % % / % Default Input Voltage 8-44 VAC 9-47 VAC 8-44 VAC 57-55 VAC Max input voltage range (adjustable for mains without battery discharge) 75-54 VAC 86-54 VAC 75-54 VAC 5-68 VAC Output Voltage Range 06-7 VAC 03-3 VAC 06-7 VAC 0-08 VAC Capacity (Volt-Amps, Watts) 40, 60 60, 390 700, 450 000, 670 500, 980 00, 980 3000, 700 4500, 3375 Surge energy rating, 4 Joules, 6.5kA 480 Joules, 6.5kA 459 Joules, 6.5kA 880 Joules, 6.5kA 00 Joules, 6.5kA peak current capability 0 ns, <5ns typical Normal mode surge voltage let <0.7% of peak typical <0.3% of peak typical through (IEEE 587 Cat. A 6kV test) Recharge time to 90% capacity 5 hours 3 hours 6 hours 3,000 m max elevation, 0-95% humidity, non-condensing, 3-04 degf 5, 000 m max elevation, 5-3 deg F Audible noise at 3.3 ft. ( m) <45 dba <4 dba <45 dba <53 dba < 47 dba Thermal Dissapation (BTU/Hr) 50 70 85 00 35 75 375 708 LOAD SU40NET SU60NET SU700NET SUA000 SUA500 SU00NET SU3000NET 3 SU5000TXFMR Watts 4 (VA) 00 40 min 45min 60hr 00min 7min 336min 336min 47min 300 40 n/a 7min min 5min 5min min min 3min 600 840 n/a n/a n/a 7min 7min 5min 5min 98min 900 60 n/a n/a n/a n/a 8min 8min 8min 59min 400 960 n/a n/a n/a n/a n/a 3min 3min 3min 000 080 n/a n/a n/a n/a n/a n/a 7min 7min 3 Additional battery pack (SU48BP) available for extra runtime. 4 Servers and other IT equipment are moving to Power Factor Corrected (PFC) power supplies of.0, where the power drawn in Volt-Amps (VA) is equal to Watts(W). For accurate sizing, use the watt rating of the equipment to determine the correct UPS and runtime. If the watt rating is unavailable use the Amp (A) rating and multiply by the voltage to obtain VA. For the most recent sizing information, please consult the Size-UPS section of APC s website at www.apc.com/sizing.
Smart-UPS Rack-mount Series Available in a broad range of sizes, Smart-UPS rack-mounts are easy to install and compatible with all popular rack systems. They offer an ideal solution for rack-optimized servers, server appliances, blade servers and other rack mounted network switches, hubs and gateways. Specifications for Smart-UPS Model: 750 000 750 000 500 00 3000 3000 5000 Part #: SUA750RMU SUA000RMU SUA750RMU SUA000RMU SUA500RMU SUA00RMU SUA3000RMU SU3000RMNET SU5000RMT5UXFMR Support for Windows NT/000/XP, Windows Server 003, Novell NetWare, SCO UnixWare, Solaris and Linux. Additional management platform integration plug-ins and application shutdown utilities available for download at www.apc.com/tools/download/. Input Line, 8 ft. line cord NEMA 5-5P NEMA 5-0P NEMA L5-30P NEMA L6-30P Output Receptacles 4 NEMA 5-5R 6 NEMA 5-5R 6 NEMA 5-5R, NEMA 5-0R 8 NEMA 5-5R NEMA L6-0R NEMA 5-5R NEMA-50R Communication Ports Serial & USB Serial Number of SmartSlot bays Smart Slot Bay Included, ind. mgmt. card Maximum Dimensions (H x W x D) (in.).75x7x6 3.5x9x8 3.5x9x6 8.8x9x7.8.3x9x5 Net Weight (lbs.) 48 48 6 63 96 96 30 Shipping Weight (lbs.) 56 55.3 69 70. 5 45 355 Replacement Battery Cartridge RBC 34 RBC RBC 3 RBC 4 RBC 43 RBC Two RBC Service Level SBC SBC 3 SBC 4 OPERATION SUA750RMU SUA000RMU SUA750RMU SUA000RMU SUA500RMU SUA00RMU SUA3000RMU SU3000RMNET SU5000RMT5UXFMR Nominal Input Voltage 0 Vac, single phase, 50 or 60 Hz (auto-selectable) 08 Vac, 50-60 Hz. Servers and other IT equipment are moving to Power Factor Corrected (PFC) power supplies of.0, where the power drawn in Volt-Amps (VA) is equal to Watts(W). For accurate sizing, use the watt rating of the equipment to determine the correct UPS and runtime. If the watt rating is unavailable use the Amp (A) rating and multiply by the voltage to obtain VA. For the most recent sizing information, please consult the Size-UPS section of APC s website at www.apc.com/sizing. milliseconds, includes detection time AVR Boost/AVR Trim 30% / % % / % Default Input Voltage Range 8-44 VAC 9-47 VAC 57-53 VAC Max input voltage range (adjustable for mains without battery discharge) 75-54 VAC 86-54 VAC 5-68 VAC Capacity (Volt-Amps, Watts) 750, 480 000, 640 750, 480 000, 670 500, 980 00, 980 3000, 700 3000, 50 4500, 3375 Output Voltage Range 06-7 VAC 03-3 VAC 0, 08 VAC Surge energy rating, 480 Joules, 6.5 ka 459 Joules, 6.5 ka 480 Joules, 6.5 ka 880 Joules, 6.5kA 00 Joules, 6.5 ka peak current 0 ns, <5ns typical Normal mode surge voltage let <0.3% of peak typical through (IEEE587 Cat A 6kV test) Recharge time to 90% capacity hours 3 hours 6 hours 3,000 m max elevation, 0-95% humidity, non-condensing, 3-04 degf 5, 000 m max elevation, 5-3 deg F Audible noise at 3.3 ft ( m) <45 dba <36 dba <46 dba <47 dba <53 dba Thermal Dissapation (BTUs/Hr) 30 68 89 7 300 400 430 LOAD SUA750RMU SUA000RMU SUA750RMU SUA000RMU SUA500RMU SUA00RMU SUA3000RMU SU3000RMNET SU5000RMT5UXFMR Watts VA 300 40 0min min 70min 64min 55min 35min min 6min 6min 600 840 98min 5min 33min 30min 9min min - 6min - 900 60 59min 8min 0min 8min 9min - - - - 400 960 3min 3min min 0min - - - - - 000 800 7min 7min 6min - - - - - - 3000 400 8min - - - - - - - -
Smart-UPS 08V Series APC Smart-UPS 08V models support high-powered servers, networking equipment and telecom equipment. Many of today s IT manufacturers are requiring 08V because it uses less current and requires smaller wiring circuit protection. Additionally, it delivers greater power than 0V systems. Telecom equipment has traditionally used 08V and continues to broaden its base in this power range. Tower Units All T models provide 400VA of 0V power. The 0 VAC output is a fixed ratio from the 08 VAC output. Rack-mount Units Specifications for Smart-UPS Model: 000 3000 5000 000 3000 5000 5000 Part#: SU00XLTNET SU3000TNET SU5000T SU00RMXLTNET SUA3000RMTU SU5000RMT5U SU5000RMXLT5U Support for Windows NT/000/XP, Windows Server 003, Novell NetWare, SCO UnixWare, Solaris and Linux. Additional management platform integration plug-ins and application shutdown utilities available for download at www.apc.com/tools/download/. Input Line Cord NEMA L6-0P NEMA L6-30P NEMA L6-0P NEMA L6-30P NEMA L6-30P Input Cord Length 6 foot 8 foot 0 foot Output receptacles (5-5R receptacles NEMA L6-30R NEMA L6-30R NEMA L6-30R NEMA L6-0R NEMA L6-30R NEMA L6-0R provide up to 400VA of 0V power ) NEMA L6-0R NEMA L6-0R NEMA L6-0R NEMA L6-30R NEMA L6-0R NEMA L6-30R NEMA 5-5R NEMA 5-5R NEMA 5-5R NEMA 5-5R Communication Ports Serial Serial & USB Serial Number of SmartSlot Bays, inc. mgt card, inc. mgmt card Maximum Dimensions (inches) 7 x 7.7 x.5 7.3 x 9 x 6. 8.8 x 9 x 7.8 3.5x9x6 8.8 x 9 x 5 8.75x9x5 Net Weight (lbs) 37 37 30 3 96 5 5 Shipping Weight (lbs) 67 56 50 5 5 45 45 Replacement Battery Cartridge RBC Two RBC RBC RBC 43 Two RBC Two RBC Pricing Level for Service Options SB-3 SB-4 SB-3 SB- SB-4 OPERATION SU00XLTNET SU3000TNET SU5000T SU00RMXLTNET SUA3000RMTU SU5000RMT5U SU5000RMXLT5U Nominal Input Voltage 08 Vac, single phase, 50 or 60 Hz (auto-selectable) milliseconds, includes detection time AVR Boost/AVR Trim % / % 30%/% %/% Default Input Voltage 57-55 VAC 4-55 VAC 57-55 VAC Max input voltage adjustable range for mains without battery discharge 5-68 VAC 3-68 VAC 5-68 VAC Output Voltage Range 78-30 VAC 85-5 VAC 78-30 VAC Capacity (Volt-Amps, Watts) 750, 600 000, 800 00, 600 400, 050 3000, 700 00, 750 Surge energy rating, 960 Joules 6.5 ka 00 Joules, 6.5kA 960 Joules 6.5 ka 480 Joules 6.5 ka 00 Joules 6.5 ka peak current capability 0 ns, <5ns typical Normal mode surge voltage let <0.3% of peak typical through (IEEE 587 Cat. A 6kV test) Recharge time to 90% capacity 3 hours 3,000 m max elevation, 0-95% humidity, non-condensing, 3-04 degf 5, 000 m max elevation, 5-3 deg F Audible noise at 3.3 feet ( m) <53 dba Thermal Dissapation (BTUs/Hr) 75 375 430 305 400 430 Load SU00XLTNET SU3000TNET SU5000T SU00RMXLTNET SUA3000RMTU SU5000RMT5U SU5000RMXLT5U Watts 3 VA 800 0 34min 34min 69min 34min 3min 69min 69min 400 960 3min 3min 3min 3min min 3min 3min 000 800 n/a 7min 7min n/a 6min 7min 7min 3000 400 n/a n/a 8min n/a n/a 8min 8min Uses Additional Battery Pack(s) SU48XLBP SU48BP n/a SU48RMXLBP n/a n/a SU48R3XLBP or UXBP48 or UXBP48 For extended runtimes refer to the table on page 0. 3 Servers and other IT equipment are moving to Power Factor Corrected (PFC) power supplies of.0, where the power drawn in Volt-Amps (VA) is equal to Watts(W). For accurate sizing, use the watt rating of the equipment to determine the correct UPS and runtime. If the watt rating is unavailable use the Amp (A) rating and multiply by the voltage to obtain VA. For the most recent sizing information, please consult the Size-UPS section of APC s website at www.apc.com/sizing.
Smart-UPS XL Series Available in tower and rack-optimized form factors. APC s Smart-UPS XL is ideal for mission-critical applications where long term runtimes are essential. Voice-over-IP (VoIP) gateways, telephone PBXs, critical application servers and data communications links will benefit from the added availability of Smart-UPS Availability Achieving 99.999% uptime requires a UPS with a runtime of greater than one hour, or a generator. Up time levels can be dramatically enhanced by increasing the run time of your UPS from five minutes to one hour. the XL models with additional battery packs. Tower Units Rack-mount Units Specifications for Smart-UPS model: 750 000 00 400 00 00 3000 5000 Part #: SUA750XL SUA000XL SU00XLNET SU400RMXL3U SU00RMXLNET SU00RMXL3U SU3000RMXL3U SU5000RMXLT5U Support for Windows NT/000/XP, Windows Server 003, Novell NetWare, SCO UnixWare, Solaris and Linux. Additional management platform integration plug-ins and application shutdown utilities available for download at www.apc.com/tools/download/. Input Line Cord NEMA 5-5R NEMA L5-30P NEMA 5-5P NEMA L5-30P NEMA L6-30P Input Cord Length 6 foot 8 foot 0 foot Output receptacles (IEC30) 8 NEMA 5-5R 6 NEMA 5-5R 8 NEMA 5-5R 8 NEMA 5-0R NEMA L6-0R, NEMA L6-30R Communication Ports Serial & USB Serial Number of SmartSlot bays SmartSlot bay included, Incl. Mgmt. Card Maximum Dimensions (H x W x D) (in) 8.5x6.7x7.3 7x7.7..5 5.5x9x5.5 8.8x9x7.8 5.5x9x6 8.75x9x5 Net Weight (lb) 53 70 4 4 5 Shipping Weight (lb) 58 40 8 43 39 45 Replacement Battery Cartridge RBC7 RBC RBC5 RBC RBC7 () RBC Service Level SB SB3 SB SB SB3 SB4 OPERATION SUA750XL SUA000XL SU00XLNET SU400RMXL3U SU00RMXLNET SU00RMXL3U SU3000RMXL3U SU5000RMXLT5U Nominal Input Voltage 0 Vac, single phase, 50 or 60 Hz (auto-selectable) milliseconds, includes detection time AVR Boost/AVR Trim 30%/% % / % Default Input Voltage 8-44 VAC 9-47 VAC 57-55 VAC Max input voltage (adjustable range for mains without battery discharge) 75-54 VAC 86-54VAC 5-68 VAC Output Voltage Range 06-7 VAC 03-3 VAC 78-30 VAC Capacity (Volt-Amps, Watts) 750, 600 000, 800 00, 600 400, 050 00, 600 00, 750 3000, 400 5000, 4000 Surge energy rating, 40 Joules, 6.5 ka 480 Joules, 6.5kA 800 Joules, 6.5kA 880 Joules, 6.5kA 00 Joules, 6.5kA peak current capability 0ns, <5ns typical Normal mode surge voltage let <0.3 % of peak, typical through (IEEE 587 Cat. A 6kV test) Recharge time to 90% Servers and other IT equipment are moving to Power Factor Corrected (PFC) power supplies of.0, where the power drawn in Volt-Amps (VA) is equal to Watts(W). For accurate sizing, use the watt rating of the equipment to determine the correct UPS and runtime. If the watt rating is unavailable use the Amp (A) rating and multiply by the voltage to obtain VA. For the most recent sizing information, please consult the Size-UPS section of APC s website at www.apc.com/sizing. 3 Hours 3,000 m max elevation, 0-95% humidity, non-condensing, 3-04 degf 5, 000 m max elevation, 5-3 deg F Audible noise at 3.3 ft ( m) <4dBA < 53 dba <46 dba < 53dBA Thermal Dissapation (BTUs/Hr) 00 0 305 55 75 375 375 430 Load SUA750XL SUA000XL SU00XLNET SU400RMXL3U SU00RMXLNET SU00RMXL3U SU3000RMXL3U SU5000RMXLT5U Watts VA 300 40 5 5 55 7 7 38 800 840 7 7 5 9 5 56 56 98 600 0 n/a 0 34 34 37 37 69 400 960 n/a n/a 3 n/a 3 4 4 3 000 800 n/a n/a n/a n/a n/a n/a 7 7 3000 400 n/a n/a n/a n/a n/a n/a n/a 8 Uses Additional Battery Pack(s) SUA4XLBP SUA4XLBP SU48XLBP SU4RMXLBPU SU48RMXLBP SU48R3XLBP SU48R3XLBP SU48R3XLBP Ultra Extended Runtime Battery Pack UXBP4 UXBP4 UXBP48 n/a UXBP48 n/a n/a n/a For extended runtimes refer to the table on page 0.
Smart-UPS XL and UX Battery Packs Long battery life By packaging the batteries in an enclosure separate from the UPS electronics, the batteries operate at reduced temperatures. Battery life is further enhanced through CellGuard intelligent battery management with high precision FastCharge, and automatic true-load battery tests. APC Smart-UPS XL increases your availability with N+ batteries Extended battery packs running in parallel with internal batteries provide extended runtime and redundancy, if a battery should fail. Smart- UPS XL battery packs are hot-swappable so you never have to take down your mission-critical loads to service the unit. Simple maintenance A battery change usually requires trained service personnel or the expense of hiring an electrician. This is not the case with APC s Smart- UPS XL. The modular Smart-UPS XL allows the user to easily replace battery packs in minutes, while the protected equipment remains up and running. Battery Packs SPECIFICATION SUA4XLBP/SU48XLBP/SU48BP SU4RMXLBPU SU48RMXLBP SU48R3XLBP UXBP4/UXBP48 Maximum Dimensions (H x W x D) 8.5 x 6.7 x 7.3 3.37 x 7 x 9" 7 x 9 x 7.8 5.5 x 9 x 6". x 7.6 x 9.7 Net Weight (lbs.) 69 lb. 67 lb. 36 lb. 40 lb. 80 lb. Shipping Weight (lbs.) 73 lb. 80 lb. 53 lb. 55 lb. 34 lb. Replacement Battery Cartridge RBC () RBC 6 () RBC () RBC 7 RBC3 Pricing Level for Service Options SB- SB- SB- SB- SB- APC Smart-UPS with UX battery packs provide ultra-extended runtime for maximum uptime APC Smart-UPS 750XL and 000XL Extended Run Tower Models Note: Runtimes are expressed in hours and are a function of the total load in watts. The actual VA may be determined by using the appropriate power factor of the attached load. The SUA750XL and SUA000XL can accept an unlimited number of external battery packs. For the most accurate and comprehensive sizing information consult the Size-UPS section of APC's website at www.apc.com. SUA750XL/SUA000XL with: SUA4XLBP SUA4XLBP 3 SUA4XLBP UXBP4 UXBP4 00W 5.3 9. 3.0 7.4 35.4 400W.5 4.6 6.7 9.0 8.7 600W.5 3.0 4.4 6.0.6 800W.0. 3. 4.4 9.4 Does not apply to SUA750XL. SU00XLNET, SU00XLTNET with: SU48XLBP SU48XLBP 3 SU48XLBP UXBP48 UXBP48 600W. 3.6 5.0 6.5. 800W.5.6 3.6 4.8 9. 400W 0.7.3.9.6 5. Does not apply to SU00RMXL3U Does not apply to SU00RMXL3U or SU3000RMXL3U Extended Run Rack-mount Models Note: Runtimes are expressed in hours and are a function of the total load in watts. The actual VA may be determined by using the appropriate power factor of the attached load. The UXBP48 is not rack mountable. For the most accurate and comprehensive sizing information consult the Size-UPS section of APC's website at www.apc.com. SU400RMXL3U with: SU4RMXLBPU SU4RMXLBPU 3 SU4RMXLBPU 8 SU4RMXLBPU 0 SU4RMXLBPU 300W.5 5.0 7. 8.4.8 500W.5.9 4.3. 4.0 800W 0.8.6.5 7.0 8.7 000W 0.5..0 5.5 7.0 SU00RMXL3U, SU3000RMXL3U, SU48R3XLBP SU48R3XLBP 3 SU48R3XLBP 8 SU48R3XLBP 0 SU48R3XLBP (SU5000RMXLT5U, SU5000R5XLTXFMR) with: 800W.0 (.8) 3.8 (4.4) 5.5 (6.) 4.0 (4.5) 7.5 (8.0) 400W.0 (.5).0 (.5) 3.0 (3.5) 8.0 (8.5) 0.0 (0.5) 000W 0.5 (0.9).3 (.6).0 (.3) 5.5 (5.8) 7.0 (7.3) 3000W (0.5) (.0) (.4) (3.8) (4.7)