Computer Mainframe MPC-127

Similar documents
NMEA 0183 Amplifier-distributor Unit With Integrated Combiner ADU-202

Universal digital repeater DR-109

Data Terminal DT-310

EPC-APL. Quick Reference Guide. Intel Pentium /Celeron Processor Fanless Tiny System. Copyright Notice. 1 st Ed 12 September 2017

Thank you for selecting UTC RETAIL s innovative Model 1170 Point of Sale solution!

Smart CAT5 Switch 16 IP Installation Guide

Hardware Reference Manual

Itona TC7521d. Hardware User Guide

Itona TC73yy Hardware User s Guide

FEATURES DESCRIPTION GENERAL SPECIFICATIONS

Industrial PC IPC191V2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter

PCIE-Q57A Quick Installation Guide

Industrial PC IPC191C2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter

2190 POS System User Guide

High Performance Computing

IP402 COM Express TYPE6 Baseboard USER S MANUAL Version 1.0A

2100 POS System User Guide

Junos WebApp Secure 5.0 Hardware Guide

Industrial PC IPC191V3 (Linux OS) IPC191V3WIN (Windows OS) General Operating, Maintenance and Installation Manual

Part Number Class Category Title UPC Code Image Download Country of Origin Cost MSRP. Short Description. Long Description. Main Specifications

FEATURES FEATURES. Macro Function Usage Supports strong Visual Basic script language which includes more than 500 built-in functions.

MPC-2150 Series Quick Installation Guide

MB-i67Q0. CPU Intel LGA1155 Socket Processors. LAN Intel 82579LM PCIe 10/100/1000 Base-T Ethernet, Intel 82583V PCIe 10/100/1000 Base-T Ethernet

We live electronics! Wir leben Elektronik! IPC-4. The compact industrial PC

PCIE-Q670-R20 Quick Installation Guide Version 2.01

NVR-CV. Network Video Recorder Hot-Swappable Tray for 3.5 HDD x 4 or 2.5 HDD x 4 Gigabit Ethernet x 2 COM x 2, USB2.0 x 6. VGA x 1, DVI-D x 1

IMB-Q354 Quick Installation Guide Version 1.0

Itona DxxS Hardware User s Guide

Copyright...1. Trademarks...1. Chapter 1 -Introduction...2. Chapter 2 - Hardware Installation...7

Part Number Class Category Title UPC Code Image Download Country of Origin Cost MSRP. Short Description. Long Description. Main Specifications

Workstation Rack-Mount 4 RU Workstation, 4 RU Rack-Mount, Hexa-Core 3.5 GHz CPU, 16 GB DDR4 RAM, 256 GB SSD

DMS / DLS / VNS Recorders

IP300 USER S MANUAL. 3.5-inch form factor ETX Base Board. Version 1.0A

8806 Series. 15 Multi-functional Touch Panel PC. Quick Reference Guide

4100 POS System User Guide

PB600/H1 BASIC SYSTEM

ARP992/ ARP992-B User Reference Manual

MPC-FR Series Fanless Ruggedized Marine Computer

ARL992/ ARL992-B User Reference Manual

We don t deliver just our mobile Data Capturing Devices with Standard Software...

ATP2B15 User Manual [Ver. 1.1] Just Touch autobasetouch. Intelligent Touch Panel Computer.

RCO-6000 Rugged Fanless Embedded System with LGA 1151 socket for Intel 6th Gen. (Skylake) Desktop Processor

NANO-945GSE2 Quick Installation Guide Version 1.0

ATH15 User Manual [Ver. 1.0] Just Touch autobasetouch. Intelligent Touch Panel Computer.

Features and Benefits. Certifications

RCO-3000 Advanced Fanless System with 5 th Gen Intel Broadwell Core i5/i3 or Celeron Processor, 2x LAN

Rugged Panel PC AcuPanel 17 User Manual Revision 1.5

IMBA-H610 Quick Installation Guide Version 1.0

Dell Inspiron 1300 Basic Features, Affordable Widescreen DELL INSPIRON 1300 REVIEWERS GUIDE. Basic Features, Affordable Widescreen

SD " Panel PC. Features. Specifications. 15 Intel ATOM D2550 Industrial Panel PC

TRBOnet Swift Mic Adapter M002

4170 POS System Installation Guide

PM-LX2 Quick Installation Guide Version 1.0

MEC-COM-M114. User s Manual

ATP15/15P/17/19 User Manual [Ver. 1.1] Just Touch autobasetouch. Intelligent Touch Panel Computer.

HEC. General Operating, Maintenance and Installation Manual

Fujitsu PRIMERGY TX100 S2 Server

RADCOM s Platform Specifications. Valid from Version 7.10

TANK- 800-D H61. Embedded System. Features. Versatile Expansion Interface. Rich I/O Function

ARL 945/ ARL945-B User Reference Manual

Overview BookSize PC. BookSize B6. BookSize B2. BookSize B1. DSM-Hotline: +49 (0) BookSize PC NEW. Page.

Compact, fanless, vibration-proof computers for rolling stock applications. Features and Benefits. Certifications

PANEL-MOUNTED INDUSTRIAL PC. ports (Ethernet, USB, serials, parallel, peripherals commonly utilized in the industrial

Example for a VISONIK system configuration:

LPC-08 Series. Quick Reference Guide. 8 Multi-functional Touch Panel PC. Copyright Notice. 2 nd Ed May 2010

Cisco MCS 7825-I1 Unified CallManager Appliance

CPC501. Best solutions to fit your demands! 6U CompactPCI Pentium M SBC.

MEC-COM-M154. User s Manual

DHS/CWS-DK-Series. Reference Manual

RCO Rugged Fanless System w/ Intel Broadwell-U Core i5/i3 or Celeron Processor

RCO Compact Rugged Fanless System with Intel Atom E3827/E3845 or Celeron J1900

UNO-2053GL. LX MHz Automation Computer with 2 x LAN, 2 x USB, 2 x RS-232, Audio. User Manual

ARP 945 User Reference Manual

User s Manual Full-Size PICMG 1.3 SHB Version 1.0

WS600/H1 BASIC SYSTEM

ACO In-Vehicle Fanless System w/ Intel Broadwell-U Core i5/i3 or Celeron Processor

2xGbE (1x Intel I210, 1x Realtek RTL8111G), 1x HDMI, 1x VGA, 1x USB3.0, 2x USB2.0

AFL-17i-HM55 17" TFT LCD Touch Panel PC. Features Highlight

Key Features. Instant Reboot The CV-100/P2000 Series supports 0.2 second instant reboot for critical factory application.

It s Under Control. Installation and Operation Guide CPB-1. Control Port Connecting Block V 1.1

Key Features. Instant Reboot The CV-100/P2000 Series supports 0.2 second instant reboot for critical factory application.

NEC Express5800/R120e-1M System Configuration Guide

IPC194. ipconv Protocol Converter

LS8000 USER MANUAL. Kitchen Display Station Controller. with Android TM

Introducing the Cisco NAM 2220 Appliance

UPLB-S , SUPPLY AND DELIVERY OF INFORMATION TECHNOLOGY PARTS, ACCESSORIES AND PERIPHERALS TECHNICAL SPECIFICATION FOR THE PUBLIC BIDDING OF:

ARL 970/ ARL970-B User Reference Manual

VARTECH. User s Guide Panel Mount PC. Model VTPC170Pi / PSi. Solutions for Demanding Applications S Y S T E M S I N C.

FabiaTech Corporation

User's Manual. Version 1.0

Dell Inspiron 580: Comprehensive Specifications

VARTECH. User s Guide Panel Mount PC. Model VTPC190P / PSS. Solutions for Demanding Applications S Y S T E M S I N C.

MIL-STD Rugged Computer User's Manual. Version 1.0 Revision Date: July. 05, 2017 THOR200. MIL-STD Rugged Computer

3U 19-inch IEC native PRP/HSR computers with Intel Celeron, Core i3 or i7 CPU. Features and Benefits. Certifications

QuickSpecs. HP 200 G1 Slim Tower Business PC. Overview. Front 1. Power Button 2. (1) Combo Jack (CTIA) 3. (1)Media Card Reader 4. (2) USB 2.

MPC 21 Series. Quick Reference Guide. 21 Multifunctional Touch Panel PC. 1 st Ed 28 october Part No. E201721W3A1R

Quick Installation Guide

IMBA-9454B-R11 Quick Installation Guide

ACS-2630 Box PC User Manual

Key Features. Instant Reboot The CV-100/P2000 Series supports 0.2 second instant reboot for critical factory application.

Transcription:

Computer Mainframe MPC-127 Operating Manual (127-2-17012012) St. Petersburg 2012

Table of Contents 1. DEVICE DESCRIPTION...4 2. DELIVERY SET...4 3. SPECIFICATIONS...5 4. DESCRIPTION OF THE DEVICE CONNECTORS...6 5. CONTROLS...9 6. DEVICE MOUNTING...10 7. TRANSPORTATION AND STORAGE...12 8. WARRANTY...13 9. DATE OF PACKING...14 10. ACCEPTANCE DETAILS...14 11. DATE OF COMMISSIONING...14 APPENDIX 1 DEYAILED DRAWING...15 Page 2

This operating manual (OM) is designed for computer mainframe MPC-127. The OM is designed for study of design, operation principles and operation rules of the device for its intended use and maintenance. The OM may also be a source of information about the device to compile relevant sections of the equipment operational documentation in which the device can be used as an integral part. Important! The company-manufacturer does not assume any responsibility that comes with loss or damage resulting from use of this product or related documentation. All information in this manual is distributed by the company for information purposes only. They are subject to change without notice of consumers; they may contain errors or inaccuracies. Information specified may not include an obligation on the part of the company Unicont Spb Ltd. Page 3

1. DEVICE DESCRIPTION MPC-127 is a computer mainframe used to perform various tasks that conform to its specification (manufacturing process control, electronic mapping, automation systems, etc.) 2. DELIVERY SET 1. Computer mainframe 1 piece 2. Brackets for destop/floor mounting 2 pieces 3. Operation Manual 1 piece 4. Feeding cable 1 piece Page 4

3. SPECIFICATIONS Power supply voltage: 90 264 V, 50/60 Hz Power demand: max. 250 W Protection class: IP 22 Computer: Processor: RAM: Type of hard drive: Hard Disc Drive Space: Video: DVD-RW Drive: Ports: Pentium Dual Core 2.5 GHz DDR3 1024 MB 1333 MHz (for Dual Channel mode) HDD, (SSD, CF(8Gb) Optional) 120 GB (250 GB Optional) Intel GMA 4500, on board DVD±RW (slim) 4 x SATA II 3.0 GB/s (does not support RAID and HOT Plug) 1 x ATA100IDE supports two IDE-devices. Operation: Dimensions: 335 x 300 x 160 mm Protection class: IP 22 Weight: max. 14 kg Storage temperature: -25 +70 C Operating temperature: -15 +55 C Output interfaces: 1 x RS-232 (DB-9M, standard COM-port) 1 x LPT (DB-25F) 4 x USB (Type A, on the rear panel) 2 x USB (Type A, on the front panel) 2 x PS/2 (keyboard and mouse/trackball) 8 x 3.5 mm jack (8-channel audio output) 2 x Ethernet (RJ-45) 1 x VGA (standard D-SUB) Expansion slots: 2 x PCI Page 5

4. DESCRIPTION OF THE DEVICE CONNECTORS There are following connectors in the rear panel of the device: Name Type Designation М PS/2 To connect mouse or trackball manipulators К PS/2 To connect the keyboard COM DB-9M To connect RS-232 serial interface USB1 To connect external USB-devices USB2 USB3 USB4 USB5 USB6 USB Type A LPT DB-25F To connect printers VGA DB-15F To connect the external display A_IN 8 x 3.5 mm jack Audio input line. To connect an external audio source. A_OUT 8 x 3.5 mm jack Audio output line. To connect an external audio amplifier. Mic 8 x 3.5 mm jack To connect the microphone Power LAN1 LAN2 Power Connector RJ-45 To connect the power source TO connect Ethernet network equipment (10 Mb/100 Mb). Pin Designation number 1 With source power of 220 VAC L. With source power of 10 36 VDC + 2 With source power of 220 VAC N. With source power of 10...36 VDC - Earthing terminal Mouse (M) and Keyboard (K) Connectors Pin Designation number 1 Keyboard signal 2 Mouse signal 3 GND 4 5 VDC 5 Keyboard sync signal 6 Mouse sync signal Page 6

COM1 Connectors Pin number 1 DCD 2 RxD 3 TxD 4 DTR 5 GND 6 DSR 7 RTS 8 CTS 9 RI Designation VGA Connector Pin number 1 Red 2 Green 3 Blue 4 NC 5 NC 6 GND 7 GND 8 GND 9 NC 10 GND 11 GND 12 GND 13 HSYNC 14 VSYNC 15 NC Designation Page 7

LPT1 Connector Pin number 1 -STROBE 2 DATA0 3 DATA1 4 DATA2 5 DATA3 6 DATA4 7 DATA5 8 DATA6 9 DATA7 10 -ACKN 11 BUSY 12 PE 13 SELECT 14 -AUTOFD 15 -ERROR 16 -INIT 17 -SLCTIN 18 25 GND Designation Page 8

5. CONTROLS The following elements are located on the front panel: - 2 USB connectors (Type A) - Power button to turn the power on/off - Reset button - Power indicator - HDD (Hard Disc Drive) activity indicator - Switch - DVD-drive DVD±RW drive HDD activity indicator Power indicator USB connectors Reset button Switch Power on/off button Page 9

6. DEVICE MOUNTING Device casing provides for it to be mounted on the desktop, on the floor or even in the rack. Before mounting choose the mounting type (with or without brackets). Following the dimensional drawing (ref. to Figure 1) prepare the place for mounting. Use brackets as necessary (ref. to Figure 2Ошибка! Источник ссылки не найден.). Mount the device, fix it with screws. Mounting being completed, lay connecting cables from external devices and connect it to the matching connectors on MPC-127. Tighten the fixing screws to avoid their inadvertent disengagement. 6 branches Figure 1 Dimensional Drawing of the Mainframe without Brackets Page 10

4 branches Figure 2 Dimensional Drawing of the Mainframe with Brackets manual. For the detailed information on the mainframe dimensions refer to the Appendix 1 of this Page 11

7. TRANSPORTATION AND STORAGE The battery charger shall be stored in heated space at air temperature of +5 ºС to +35 ºС (maximum values of -25 ºС to +70 ºС), at relative humidity of air not exceeding 95 % at temperature of +25 C and content of dust, oil, moisture and aggressive admixtures in the air not exceeding the norms envisaged by GOST 12.1.005-88 for the working zone of production areas. The device shall be transported in transport container of the manufacturer in closed transport. Means of transport: automobile and railway closed transport (covered wagons, universal containers) by air (in pressurized and heated bays of airplane) by sea (in dry service spaces). The device shall be transported in accordance with the transport regulations in force for the particular transport. During handling operations and transportations strictly observe the requirements of handling marks on boxes and do not allow bumps and impacts which can affect preservation and serviceability of the device. Packed devices shall be reliably secured in vehicles. After storage in stores or transportation at temperature below +10 ºС the devices shall be unpacked only in heated spaces after keeping them unpacked in under normal climatic conditions for12 hours. Page 12

8. WARRANTY The manufacturer guarantees the unit MPC-127 complies with this manual provided that the operation, transportation and storage conditions are adhered to during the warranty period. The unit s warranty period expires 24 months from the date of its shipping from the manufacturer s storehouse. Within the warranty period, the owner is entitled for a free repair, or a replacement of a separate part, provided that the malfunction occurred through the manufacturer s fault. Warranty repair is provided if the unit is submitted with the manufacturer s label and a legible serial number available on it, as well as this operating manual. The manufacturer is not responsible and cannot guarantee the unit s operation: 1. After the warranty period is over; 2. In case of the failure to observe the unit s operation, transportation, storage and installation rules and conditions; 3. If the unit is in an unmarketable condition, or has a damaged body, and other causes beyond the manufacturer s control; 4. If self-made electrical devices were used. 5. If there was an attempt to repair the unit by a person who is not an authorized representative of the manufacturer. If the owner loses this operating manual or the manufacturer s label with a serial number, the manufacturer shall not provide their copies, and the owner shall be divested of the right for a free repair during the warranty period. Upon the warranty expiry, the manufacturer shall facilitate the repair of the unit at the owner s expense. Note: in case of warranty repair, the unit s disassembling from the installation site and its delivery to the manufacturer s service center are done at the owner s expense. Visit the manufacturer s website www.unicont.spb.ru (section support/warranty ) to find: forms to fill in claims, full warranty description; full description of the warranty service rendering procedure. The manufacturer service center s address and contact details: Unicont SPb, Ltd. Bld. 26Е Kibalchich Str., Saint Petersburg, 192174, Russia tel.: + 7 (812) 622 23 10, +7 (812) 622 23 11 fax: +7 (812) 362 76 36 e-mail: service@unicont.spb.ru Page 13

9. DATE OF PACKING Computer Mainframe MPC-127 name of article designation serial number Packed Unicont SPb Ltd., Russia. Manufacturer according to the requirements of the current technical documentation. post signature clarification of signature year, month, day 10. ACCEPTANCE DETAILS Computer Mainframe MPC-127 name of article designation serial number was manufactured and accepted in accordance with the regulatory requirements of the state standards and applicable technical documentation, and is suitable for operation. Quality control representative Stamp here signature clarification of signature year, month, day 11. DATE OF COMMISSIONING Computer Mainframe MPC-127 name of article designation serial number The unit has been put into operation. Date of installation: Place of installation: Person in charge of installation: Page 14

APPENDIX 1 DEYAILED DRAWING (Front) (Back) Page 15