Open Smart Metering Gateway EWIO-9180-M. Energy consumption monitoring and energy monitoring in buildings, on machines, installations and systems

Similar documents
Modbus RTU components. for automation in buildings, installations and systems

Modbus RTU components. for automation in buildings, installations and systems

Product summary. I/O components LON FT5000. I/O components CAN. Guiding icons. with spring clamp terminal block. LF-DI230 4 digital inputs

D80 IP65. T/M Converter 4 channels Input module P/N temperature inputs

The Next Level of Energy Data Management Fast Data Acquisition via Parameterization No Programming

WAGO Energy Data Management Efficiency Is That Easy!

AC500-eCo: your PLC from ABB Unique scalable concept, optimal costs... Change for more!

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O

Z-GPRS2-SEAL THE SIMPLEST REMOTE MANAGEMENT SYSTEM FOR UNIVERSAL APPLICATIONS GSM/GPRS DATALOGGER WITH BUILT-IN I/O S AND TELECONTROL FUNCTIONS

UMG 96RM. UMG 96RM Universal measurement instrument. Areas of application

A NEW DATA LOGGER Stand alone. Secure. Fast.

THE RAINBOW SCADA D-700

iologik E2200 Series Smart Ethernet remote I/O with Click&GO Logic Introduction Remote I/O PC-Free Alarm and Control Intelligence

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O Daisy-Chained Ethernet I/O Connection

Communication Interface

Standard protocol support (e.g. MODBUS, SNMP, M-Bus), possibility to install dedicated user protocols

Submittal Data Sheet WAGO Node for itm

mark150s mark150/485s DDC controllers Summary

COMTRAXX COM460IP. BMS-Ethernet-Gateway

Smart Building Automation System Solutions

ICP DAS. ICP DAS 2015 M2M WLAN Wireless Solutions

Version 1.0c May 6, 2010 ATK3

with Backlight Graphic LCD Screen

The securityprobe5es-x20 s software motion detection and a rich notification suite keeps you up to date 24 hours a day. securityprobe5es-x20

The new Expert Logger 400: Industry 4.0 ready!

ZLAN5443A. User Manual

Smart Monitoring System compact, secure, efficient

PXR Series Advanced Self-Tuning Temperature and Process Controllers

Web-enabled DAQ System

Ammonit Meteo-40 Data Logger

COMTRAXX COM465DP. Condition Monitor with integrated gateway for the connection of Bender devices to PROFIBUS DP and Ethernet TCP/IP networks

icex-cmtm General specs and Installation guide

Transportation Solutions LÜTZE Rail Technology. Product overview Control Technology

SecurityHawk SecurityHawk 8-20

QUICK-START EMU M-BUS CENTER ENGLISH

EXOcompact. Freely programmable controller

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

Compatible with all of the AKCP range of Intelligent Sensors it provides a complete environmental, access control and security monitoring solution.

MXPLC. Compact PLC process station. Summary. Application HVAC control systems, data acquisition, interfacing 3 rd party systems.

- Ovens - Food processing - Dryers, etc.

COMTRAXX COM465IP. Condition Monitor with integrated gateway for the connection of Bender devices to Ethernet TCP/IP networks

COMTRAXX COM465IP. Condition Monitor with integrated gateway for the connection of Bender devices to Ethernet TCP/IP networks

Standard protocol support (e.g. MODBUS, SNMP, M-Bus), possibility to install dedicated user protocols

Standard protocol support (e.g. MODBUS, SNMP, M-Bus), possibility to install dedicated user protocols

8B SLX300 Data Acquisition System

UniMod Intelligent Communication for all Metering Application

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

General information. Display. Supply voltage

Free Programmable Control Units

Smart Energy & Power Quality Solutions. ProData data logger. Data collection and recording

Features and Benefits. Certifications

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

MPC / 6. First interface. distance up to 15m, speed up to 19,2Kbit/s, GSM modem support. 4 band 850/900/1800/1900 MHz

Electronic Multi-channel Load PMLA. 150 W / 600 W 40 V up to 240 V 1 A up to 120 A. Preliminary Edition

iologik 2500 HSPA/GPRS/WLAN Series

General information. Display. Supply voltage. Input current

EXOcompact. Third generation freely programmable controllers

General information. Display. Supply voltage. Input current

iothinx 4500 Series (45MR) Modules

DS 500 Intelligent chart recorder for compressed air and gases

MIC-2 Multi-instrument DATA SHEET

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function

Sensor Control... Access Control... securityprobe 5E-X20

Open Platform for Developing and Testing Smart Grid Automation Systems. Igor Alvarado National Instruments Corp.

General information. Display. Supply voltage. Input current. Encoder supply. Output current

X-Log Expert Data Logger

General information. Display. Supply voltage

BMS-Ethernet-Gateway COM460IP

Features. :. Introduction. :. Leader 5000 Appearance. Ethernet-Based Block I/O System

Com X 210, Com X 510 Technical Datasheet

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

The ECL Apex 20 is operated by means of either a PC or the ECL Apex Web Panel. Temperature input signals are based on Pt 1000 or 0-10 V.

VersaMax Micro and Nano Technical Product Presentation

INSTRUMENTATION. Hydropower and water control applications

IMIO100 IMIO105. DDC controllers. Summary

Laboratory automation

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

ProfiMessage. NEW Modular. Secure. Adaptable.

iologik 2500 Series Quick Installation Guide

FOUR FUNCTIONS ONE SOLUTION

- Ovens - Food processing - Dryers, etc.

WattmonMEGA Remote Monitoring & Control Platform

Efficient. Innovative. Sustainable.

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

General information. Display. Supply voltage. Input current

PEAK TM. PEAK TM controllers. Mid-Market BAS Smart equipment controllers. HVAC/R controllers

The securityprobe5e-x60 s rich notification suite keeps you up to date 24 hours a day. securityprobe5es-x60. securityprobe5es-x60

FLEXIBLE AND MODULAR PROCESSOR T11 MULTI I/O MODULES. The Heart of ADwin Pro-II. All-rounder with A/D, D/A, counters, SSI and EtherCAT

General information. Display. Supply voltage. Input current. Encoder supply. Output current

PBSCONTROL. AMS-R4000 Modular RTU. Remote Terminal Unit

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

Smart Energy & Power Quality Solutions. ProData datalogger. Datalogger and Gateway

CHP GAS MONITOR GDR 1404

Transcription:

Open Smart Metering Gateway EWIO-9180-M Energy consumption monitoring and energy monitoring in buildings, on machines, installations and systems

Open Smart Metering C Logline Powerful components for energy data collection Energy consumption monitoring and energy monitoring in buildings, on machines, installations and systems. is extending its C Logline range further by including products for building and industry automation using the powerful data logger EWIO-9180-M. The EWIO-9180-M (Ethernet Web I/O 9180 Metering) is a powerful data logger for tasks in energy management and energy controlling and the like. Counter data, temperature and other sensor signals can be detected via the integrated I/Os of the M-Bus interface, and switching and actuating signals can be generated. The data for higher-level energy management systems are provided by an integrated database via LAN. Communication with the management level can also be established, alternatively, via WLAN or UMTS adapter. An integrated web server allows the EWIO-9180-M to be configured and parameterized via a web browser, independently of the platform. Various applications can be programmed using the Linux Shell installed on the server or using C/C++ or the JAVA development environment. The number of I/Os can be increased flexibly by means of extension modules that can be connected as an option. DIN EN ISO 50001 describes the requirements of an energy management system. Its core elements are energetic evaluation and energy performance indices: Among other things, the company must: a) analyze the use of energy and energy consumption on the basis of measure ments b) identify the main energy users on the basis of energy consumption c) perform activities for improving energy-based services d) determine, record and regularly check appropriate energy performance indices. For carrying out all these activities, an easyto-operate energy data collection central unit, a metering gateway, is required. To meet these requirements and based on experience with more than 1,000 installations, has developed the open smart metering gateway "EWIO-9180-M". This open smart metering gateway creates consumption transparency, promotes energy efficiency and increases energetic use. The EWIO-9180-M (M stands for metering) is an IP-based solution, allowing the user to give the consumer exact data related to his energy consumption and his meter counts. The device concept is directed at so-called VARs (Value-Added Resellers) and OEMs (Original Equipment Manufacturers). For these user groups, the two following applications are possible. The "Open Smart Metering" approach from gives users the option to adjust the EWIO-M to their own application situation.

Applications for the ewio-9180-m Application 1 - Application programming using the ewio-9180-m The EWIO-M offers the option of implementing standard-language-based individual functions by means of shell script or even C/C++ that run directly on the EWIO-M. This gives the programmer access down to the core of the Linux operating system. The reason for this is that the programming target group of VARs and OEMs wants to differentiate it increasingly from the competition via a specific use. EWIO-M gives it a software and hardware platform that frees it from having to develop its own device. Target users: Energy evaluation service providers and embedded Linux programmers who want to run their own applications on/with EWIO-M. Application 2 - Data evaluation using the ewio-9180-m In its basic functionality, the EWIO-M is a fully functional smart metering gateway, a data logger. It collects meter counts and temperatures via the M bus, saves them in accordance with the reading period ((5 min.) 15 minutes, 1 hour,...) for up to 40 days and more for 80 meters or data points power-failure-proof in an implemented SQLite database and transfers the data records in intelligently structured CSV files to the evaluating computer via FTP or by e-mail. These CSV files can also be edited directly from MS Excel. Target users: Energy evaluation software service providers that communicate with the EWIO-M exclusively via the TCP/IP interface. At the center of this device approach, various extension modules and bus modules are additionally available, and for configuration a web browser integrated into the EWIO-M is available. The web browser allows the end user to operate the inputs and outputs of the EWIO-M directly protected by password. He can set the relays and query the inputs. This is a useful function for carrying out start/stop or ON/OFF interventions by hand. EWIO-9180-M product characteristics Inputs and outputs 4 relay outputs (changeover contact, 5 A) 4 digital contact inputs 4 S0 meter pulse inputs 4 constant-voltage outputs for potential-free signal contacts 2 analog inputs 0 to 10 V / can be switched to 2 temperature PT1000 2 analog inputs 0 to 20 ma 2 analog outputs 0 to 10 V 2 analog outputs 0 to 20 ma Field buses M-Bus (DIN EN 13757 -T1,2,3) EW-RS485 extension bus for 6 s RS485 (Modbus prepared) Other Micro-SD card slot in base fitted with 2-GB SD (up to a max. of 8-GB SD pluggable) USB interface for WLAN adapter and UMTS modem (types on request) RJ45 Ethernet 10/100BaseT autosensing, TCP/IP

Special properties EVU/VNB measuring period synchronization M-Bus "freeze" support Width 125 mm, (7 HP), suitable for mounting as installation distributor Operating voltage 24 V DC, with NG4 power supply via jumper also operatable in 230 V AC installations 6 extension modules connectable via jumper and/or JY(ST)Y 2 x 2 x 0.8 80 M-Bus loads can be switched directly no M-Bus level converter required Second RS485 (Modbus) interface Documentations included in delivery Quick start User manual Driver M-Bus interface Driver Modbus (RTU) interface Driver system interface Linux manual WLAN manual WLAN connection Configuration and setup of a ppp connection Wiring diagram of the ewio-9180-m DC supply Extensions RS485 (Modbus RTU) M-Bus DC supply Extensions Ethernet 2GB (max. 8GB) Micro SD DC supply 4 S0 inputs 4 digital inputs 24 V DC/20 ma 24 V DC/20 ma 24 V DC/20 ma 15 V DC/30 ma 4 analog outputs 2 x 0..10 V DC/5 ma 2 x 0(4)..20 ma 4 analog inputs 2 x voltage: 0..10 V Resistance: 40 Ohm.. 4 MOhm 2 x current: 0-20 ma USB 1) S0 pulse from counter 2) Contact with 24 V DC external voltage 3) Potential-free contact

Overview of the range of products EWIO-9180-M P/N 110910 C Logline - Extension modules for the ewio-9180-m EW-DI4 4 digital inputs P/N 1109541319 EW-DI10 10 digital inputs P/N 1109511319 EW-AI8 8 individually configurable inputs (0 to 10 V DC, temp.) P/N 11095213 EW-TO4 4 digital triac outputs P/N 11095013 EW-DO4 4 relay outputs (changeover contacts) P/N 1109561321 EW-AO4 4 analog outputs (0 V to 10 V DC) P/N 1109551302 EW-DIO4/2 4 digital inputs and 2 relay outputs (changeover contacts) P/N 1109531326 EW-DIO4/2 IP65 4 digital inputs and 2 relay outputs (changeover contacts) P/N 1109531326IP S0/M converter, 4-channel 4 S0 inputs according to DIN EN 62053-31 Class A P/N 110556 S0/M converter, dual-tariff 2 S0 inputs and 1 S0 dual-tariff input P/N 110556-01 T/M converter, 4-channel 4 S0 inputs according to DIN EN 62053-31 Class A P/N 110562 Power supply NG4 gray P/N 110561-01 Our website offers comprehensive information on all technical details.

GmbH is member in the following organizations and associations. USA Inc. 200 Tornillo Way Tinton Falls, NJ 07712 USA Phone + 1-732-389-1300 Fax + 1-732-389-9066 France SAS 28, Rue Schweighaeuser 67000 Strasbourg France Phone + 33 3886 170 73 Fax + 33 3886 194 73 (SINGAPORE) PTE. LTD. 1 Kaki Bukit Ave 3 # 10-01 KB-1 Singapore 416087 Phone + 65 6747 0998 Fax + 65 6746 31 20 Shanghai Branch Room 1518, Xu Hui Business Building, 168, Yu De Road, XuHui District, Shanghai 200030 China Phone + 86 21 33 6342 28 Phone + 86 21 33 634334 Fax + 86 21 33 6342 24 GmbH Im Tal 2 78176 Blumberg Germany Phone + 49 7702 533-0 Fax + 49 77 02 533-189 info@metz-connect.com 899364-01 06/2013