C E R T I F I C A T E O F C O M P L I A N C E

Similar documents
C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

E A54-UL 2012-AUGUST-29 XP POWER L L C SUITE E DYER RD SANTA ANA CA 92705

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

CERTIFICATE OF COMPLIANCE

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

C E R T I F I C A T E O F C O M P L I A N C E

UL TEST REPORT AND PROCEDURE

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

File E Project 91SC COMPONENT POWER SUPPLIES INFORMATION TECHNOLOGY EQUIPMENT INCLUDING ELECTRICAL BUSINESS EQUIPMENT

C E R T I F I C A T E O F C O M P L I A N C E

UL TEST REPORT AND PROCEDURE

Page 1 of 2. Power Supply SL POWER ELECTRONICS CORP 6050 KING DRIVE, BLDG A VENTURA CA 93003, USA

File E Project 93ME39941, Issued: November 29, 1993 New: April 26, 2006 REPORT COMPONENT - POWER SUPPLIES. For Use In

File E Project 01ME October 15, 2001 REPORT

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

COVER PAGE FOR TEST REPORT

File E Project 89ME November 30, 1989 REPORT COMPONENT - POWER SUPPLY. Vicor Corp. Andover, MA

Page 1 of 2. Component - Power Supply SL POWER ELECTRONICS CORP 6050 KING DR. BLDG A VENTURA, CA 93003, USA

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

File E Project 90ME March 12, 1991 REPORT

File E Project 98ME March 9, 1998 REPORT

Procedure And/Or Report Material

File E Project 03ME REPORT COMPONENT - POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL BUSINESS EQUIPMENT

COVER PAGE FOR TEST REPORT

CERTIFICATE OF COMPLIANCE

C E R T I F I C A T E O F C O M P L I A N C E

Universal input VAC <250mW No load power consumption -25 C to +80 C Operating temperature, with derating

C E R T I F I C A T E O F C O M P L I A N C E

Page 1 of 2. Component - Power Supply SL POWER ELECTRONICS CORP BLDG A, 6050 KING ST VENTURA CA 93003, USA

File E Page T1-1 of 2 Issued:

Universal input VAC <150mW No load power consumption

C E R T I F I C A T E O F C O M P L I A N C E

File E Project 07SC April 8, 2008 REPORT COMPONENT TEMPERATURE INDICATING AND REGULATING EQUIPMENT

ISAFJORDSGATAN 16B SE STOCKHOLM SWEDEN

File E Project 03ME Issued: March 4, 2004 REPORT COMPONENT - POWER SUPPLIES, SPECIALTY - COMPONENT

File E Project 11SC May 15, 2012 REPORT COMPONENT DRIVERS FOR LIGHT-EMITTING-DIODE ARRAYS, MODULES AND CONTROLLERS

File E Vol. 1 Sec. 35 *Page 1 Issued: and Report Revised:

IEC/EN/UL60950 & CE certified, EN55032 Class B

File E Project 91SC Issued: July 4, 1991 Revised: August 23, 2007 REPORT

Parameter Condition Min. Typ. Max. Internal Input Filter 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

FMP VDC RECTIFIER 42 Amps 2000 Watts

Parameter Condition Min. Typ. Max. Internal Input Filter. nom. Vin = 230VDC 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

SPECIFICATION FOR APPROVAL AC/DC ADAPTOR

ORDERING INFORMATION SEE PAGE 6

Series Specifications Ta= 25 C, nom. Vin, full load and after warm-up unless otherwise stated) Parameter Condition Min. Typ. Max.

C E R T I F I C A T E O F C O M P L I A N C E

Notes: Note1: Other output voltages on request Note2: Efficiency is tested at nominal input (115/230VAC) and full load at +25 C ambient

Input Voltage Range AC Input. Input Frequency Range. Output Power natural convection. Operating Temperature Range. Model Selection

Siemens AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE AMBERG, GERMANY

FMPe30.48G 48VDC RECTIFIER 60 Amps 2900 Watts

Safety Standards. Model Number:

CERTIFICATE OF COMPLIANCE

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

Safety Standards. Model Number:

IEC Medical electrical equipment Part 1: General requirements for basic safety and essential performance

060AAS19 B MDS. MDS Medical AC-DC Adapter 19Volt, 60Watt / MDS-060AAS19 B. Highlights & Features. Safety Standards. Model Number: General Description

PGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY

Safety Standards. Model Number:

Power Supply SL POWER ELECTRONICS CORP BLDG A, 6050 KING DRIVE VENTURA CA 93003, USA

CERTIFICATE OF COMPLIANCE

CERTIFICATE OF COMPLIANCE

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

Industrial Power Supplies

Features. Regulated Converter. RAC35-G/OF 35 Watt 4 x 2 Open Frame RAC35- SG/OF. AC/DC Converter

C E R T I F I C A T E O F C O M P L I A N C E

040APS12 B MDS. MDS Medical AC-DC Open Frame 12Volt, 40Watt / MDS-040APS12 B ``` Highlights & Features. Safety Standards.

Packaging (5) Protection (3) Isolation Voltage (4)

Protection (3) alternative Pinning Option (4) Single or Dual

KUANTECH (SHEN ZHEN) COMPANY LIMITED KSAFD W1UK

RM- S/_ Protection (3) Isolation Option (4) Single

Max. Input Power (W) Input Current. (A pk/50%-µs) Dimming Method. 1-10V Isolated DALI

Max. Input Power (W) Input. (Arms) 277V. Vin 41/ 100. Dimming Method. 1-10V Isolated UL Class 1 and Class 2 Wiring. Enclosure

DLB1248 single channel EASY-BLE

335 台灣桃園縣大溪鎮南興里仁和路二段 255 號英業達股份有限公司 MS. NANCY TSAI

Safety Standards. Model Number:

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Transcription:

C E R T I F I C A T E O F C O M P L I A N C E Certificate Number 20141229-E135493 Report Reference Issue Date E135493-A27-UL 2014-DECEMBER-29 Issued to: VICOR CORP 25 FRONTAGE RD ANDOVER MA 01810 This is to certify that representative samples of POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT INCLUDING ELECTRICAL BUSINESS EQUIPMENT AC/DC Converter- VIA PFM series Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate. Standard(s) for Safety: UL 60950-1 and CAN/CSA C22.2 No. 60950-1-07- Information Technology Equipment - Safety - Part 1: General Requirements Additional Information: See the UL Online Certifications Directory at www.ul.com/database for additional information Only those products bearing the UL Certification Mark should be considered as being covered by UL's Certification and Follow-Up Service. Recognized components are incomplete in certain constructional features or restricted in performance capabilities and are intended for use as components of complete equipment submitted for investigation rather than for direct separate installation in the field. The final acceptance of the component is dependent upon its installation and use in complete equipment submitted to UL LLC. Look for the UL Certification Mark on the product. Bruce Mahrenholz, Assistant Chief Engineer, Global Inspection and Field Services UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at www.ul.com/contactus Page 1 of 1

Issue Date: 2014-12-22 Page 1 of 5 Report Reference # E135493-A27-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: UL 60950-1, 2nd Edition, 2014-10-14 (Information Technology Equipment - Safety - Part 1: General Requirements) CAN/CSA C22.2 No. 60950-1-07, 2nd Edition, 2014-10 (Information Technology Equipment - Safety - Part 1: General Requirements) Component Recognition QQGQ2, QQGQ8 (Power Supplies for Information Technology Equipment Including Electrical Business Equipment) AC/DC Converter VIA PFM series See Miscellaneous Enclosure for model details. Rated Input Voltage: 85-264 Vac(rectified) Rated Output Voltage: 24 Vdc Rated Output Power: 400W max See Miscellaneous Enclosure for model details. Applicant Name and Address: VICOR CORP 25 FRONTAGE RD ANDOVER MA 01810-5424 UNITED STATES This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the above referenced Standards. The products have been found to comply with the requirements covering the category and the products are judged to be eligible for Follow-Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on such products which comply with this Test Report and any other applicable requirements of UL LLC ('UL') in accordance with the Follow- Up Service Agreement. Only those products which properly bear the UL Mark are considered as being covered by UL's Follow-Up Service under the indicated Test Procedure. The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety. UL authorizes the applicant to reproduce the latest pages of the referenced Test Report consisting of the first page of the Specific Technical Criteria through to the end of the Conditions of Acceptability. Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. Prepared by: Hong Ung Reviewed by: Dean Baker Copyright 2015

Issue Date: 2014-12-22 Page 2 of 5 Report Reference # E135493-A27-UL Supporting Documentation The following documents located at the beginning of this Procedure supplement the requirements of this Test Report: A. Authorization - The Authorization page may include additional Factory Identification Code markings. B. Generic Inspection Instructions - i. Part AC details important information which may be applicable to products covered by this Procedure. Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of this Test Report. ii. Part AE details any requirements which may be applicable to all products covered by this Procedure. Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of each Test Report. iii. Part AF details the requirements for the UL Certification Mark which is not controlled by the technical standard used to investigate these products. Products are permitted to bear only the Certification Mark(s) corresponding to the countries for which it is certified, as indicated in each Test Report. Product Description The VIA PFM Series are a family of isolating AC-DC converters that are designed for building-in. The output is considered SELV. Model Differences See Miscellaneous Enclosure for model nomenclature Technical Considerations Equipment mobility : for building-in Connection to the mains : not directly connected to the mains Operating condition : continuous Access location : for building-in Over voltage category (OVC) : OVC II Mains supply tolerance (%) or absolute mains supply values : 85-264 Vac (rectified) Tested for IT power systems : - IT testing, phase-phase voltage (V) : N/A Class of equipment : Class I (earthed) Considered current rating of protective device as part of the building installation (A) : N/A Pollution degree (PD) : PD 2 IP protection class : IP X0 Altitude of operation (m) : Up to 5000 Altitude of test laboratory (m) : less than 2000 meters Mass of equipment (kg) : 0.157

Issue Date: 2014-12-22 Page 3 of 5 Report Reference # E135493-A27-UL Engineering Conditions of Acceptability For use only in or with complete equipment where the acceptability of the combination is determined by UL LLC. When installed in an end-product, consideration must be given to the following: The following secondary output circuits are SELV: All. The following secondary output circuits are at hazardous energy levels: All. The investigated Pollution Degree is: 2 The following end-product enclosures are required: Mechanical, Fire, Electrical. An external bridge rectifier is required in front of the PFM. The output is separated from the input by reinforced insulation. The VIA PFM was evaluated over the full operating range of 85-264Vac rectified. See de-rating curve for maximum output power vs. case temperature in Miscellaneous Enclosure. The case must be earthed in the end application. The VIA PFM was evaluated with fast acting external fuse rated 8A (Littelfuse 216 series or Bussmann S501). Additional Information N/A

Issue Date: 2014-12-22 Page 4 of 5 Report Reference # E135493-A27-UL VIA PFM Model Number: PFMaabbcddewwxxyzz Example: PFM4914VB6M24D0T00 PFM = Constant Product Function PFM Power Factor Module aa = 49 Package Length Designator 44 4.4 inches 49 4.9 inches bb = 14 Package Width Designator 14 1.4 inches c = V Package Type V Chassis mount B Board mount dd = B6 Input Voltage range B6 85-264 Vac e = M Range Ratio (Vin high / Vin low) M 3.1 ww = 24 Output Voltage 24 24 Vdc 48 48 Vdc xx = D0 Output Power B0 200W D0 400W y = T Product Grade C -20 to 100 C T -40 to 100 C M -55 to 100 C zz = 00 Options (non-safety related) 00 Any alphanumeric

Issue Date: 2014-12-22 Page 5 of 5 Report Reference # E135493-A27-UL Customer Special Model Number PFA175B240C400A33 PFA175B240T400A33 PFA175B480C400A33 PFA175B480T400A33 PFA175C240C400A33 PFA175C240T400A33 PFA175C480C400A33 PFA175C480T400A33 PFA175G240C400A33 PFA175G240T400A33 PFA175G480C400A33 PFA175G480T400A33 Equivalent Standard Model Number PFM4914VB6M24D0C00 PFM4914VB6M24D0T00 PFM4914VB6M48D0C00 PFM4914VB6M48D0T00 PFM4914BB6M24D0C04 PFM4914BB6M24D0T04 PFM4914BB6M48D0C04 PFM4914BB6M48D0T04 PFM4914BB6M24D0C08 PFM4914BB6M24D0T08 PFM4914BB6M48D0C08 PFM4914BB6M48D0T08 Output Power vs. Case Temperature for operation from 85-264 Vac (rectified).