EDGE LM XLMA Series Data Module

Similar documents
Request for Qualifications

BASELAYER CORE PA20 Power Module

QuickSpecs. HP Performance Optimized Datacenter (POD) 20ce. Overview. Retired

INNOVATE DESIGN APPLY.

INNOVATE DESIGN APPLY.

84 kw, Tier 3, Direct Expansion, 937 ft 2

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Power & Cooling Considerations for Virtualized Environments

MSYS 4480 AC Systems Winter 2015

Precision Cooling. Precision Cooling Advantages

3300 kw, Tier 3, Chilled Water, 70,000 ft 2

Driving Business Value through Enterprise Agreements and Partnering

Remote Management of Data Center White Space: What to Manage and How? Ashish Moondra Sr. Product Manager Chatsworth Products

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

Metered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R

Comprehensive Data Center Energy Management Solutions

ipdu Pocket Guide NORTH AMERICA

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

Metered Rack PDU Rack PDU, Metered, Zero U, 5.7kW,208V,(36)C13& (6)C19; 10' Cord

1008 kw, Tier 2, Chilled Water, ft 2

Industry leading low energy evaporative fresh air cooling.

200 kw, Tier 3, Chilled Water, 5250 ft 2

Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13

Intelligent PDUs. Best in Class Outlet Density Optimal Form Factors Superior Reliability

APC by Schneider Electric Elite Data Centre Partner

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

Variable Density, Closed-Loop, Water-Cooled Data Center Solution

ipdu Pocket Guide INTERNATIONAL

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.

Evaporative free air cooling technology Providing evaporative free air cooling solutions.

COOLING SOLUTIONS. SmartRack Close-Coupled Cooling for IT Environments

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)

Richmond Heights. Smart Wi-Fi Capacitive Touch With Dual Protocols Universal Controller. Go Green

SmoothAir Modular Precision Cooling

ECOBAY: Closed loop water cooled server cabinet for data centers

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

SMART SOLUTIONS TM INTELLIGENT, INTEGRATED INFRASTRUCTURE FOR THE DATA CENTER

Data Center Optimized Controls

WIRELESS ENVIRONMENTAL MONITORS

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant

ATS22C21S6U softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp)

Rack & Enclosure Systems

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

InRow Chilled Water. Up to 70kW. Close-coupled, chilled water cooling for medium to large data centers. Row-Based Cooling.

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100hp)

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

Total Modular Data Centre Solutions

Metered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord

DATA CENTER AIR HANDLING COOLING SOLUTIONS

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATS22D47S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

Next Generation Data Center Facilities Design. Presenter: Ping Lin

SmartCabinet Intelligent, Integrated Containment for IT Infrastructure

Enabling Business Critical Continuity for Unified Communications. Andy Liu Product Manager, Asia Pacific

IXcellerate Moscow One Datacentre - Phase 1 & 2 Overview

ATS22C17Q. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

Configurable power distribution

Where s the Heat Coming From. Leland Sparks Global Account Technical Consultant Belden

FREEING HPC FROM THE DATACENTRE

2000 kw, Tier 3, Chilled Water, Prefabricated, sq. ft.

Close-coupled cooling

brightsolid Data Hall 1 Keysource Technical Specifications

ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)

ZTE ZXCR Series DX In-Row Air Conditioning Product Description

Technical Manual Nova: Cabinet Security Management System (CSMS)

5.2 MW, Pod-based build, Chilled Water, ft 2

Network Service Appliances

2U µtca Chassis with 12 AMC slots VT881

Sept 29, Schneider Electric s Micro Data Center Solutions

STULZ Micro DC. with Chip-to-Atmosphere TM Liquid to Chip Cooling

Symmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output

TABLE OF CONTENTS. About ScaleMatrix... 3 ScaleMatrix vs. Traditional Data Center Comparison... Colocation Services...

Dell Latitude E5410/E5510

Ecoflair Air Economizers

Rittal Cooling Solutions A. Tropp

VIRTUAL MATRIX DISPLAY CONTROLLER

Installation Service. 1.0 Executive Summary. Factory Trained Technician Train Customer Support Staff On Basic Operation Of The Equipment

HP Modular Cooling System: water cooling technology for high-density server installations

SmartRow Solution Intelligent, Integrated Infrastructure for the Data Center

SmartOnline V 10kVA 7kW Online, Double-Conversion UPS, 6U Rack/Tower, Extended Run, Pre-installed SNMP port, RS232, 3 Phase in-single Phase out

PRODUCT FEATURES AND ADVANTAGES

MEASURE MONITOR UNDERSTAND

Indirect Adiabatic and Evaporative Data Center Cooling

JT Rue Des Pres DATA CENTRE

Thermal management. Thermal management

4-Bay Mobile Rack Backplane for 2.5in SATA/SAS Drives

Liebert. icom Thermal System Controls Greater Data Center Protection, Efficiency & Insight

Energy Logic: Emerson Network Power. A Roadmap for Reducing Energy Consumption in the Data Center. Ross Hammond Managing Director

Running Your Data Center Under Ideal Temperature Conditions

Data Center Infrastructure Management (D.C.I.M.)

Optimize Your Data Center. Gary Hill VP, Business Development DVL Group, Inc.

SmartOnline 120V 1.5kVA 1.2kW Double- Conversion UPS, 2U Rack/Tower, Extended Run, Pre-installed WEBCARDLX Network Interface, USB, DB9 Serial

DATA/SPEC SHEET VIRTUAL MATRIX DISPLAY CONTROLLER

Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h

Transcription:

TM

TM EDGE LM XLMA Series Data Module The EDGE LM Data Modules can be deployed indoors or outdoors and have been designed to provide density and rack adaptable IT space for environments enabling low to medium kw usage models suitable for the Service Provider and Enterprise markets.

BASELAYER EDGE LM Data Module Front Block USAGE MODEL SCENARIO Indoor/Outdoor, density adaptable Data Module for environments enabling low to medium kw usage models suited for the Service Provider and Enterprise markets. Cooling Block Chilled Water Configuration Shown End Block Performance Requires no raised floor Up to 500kW of cooling capacity Preconfigured space for 35 (LM2 shown), 60, 85 or 110 x 52U cabinets Busway power distribution (2000A) Cooling Configuration Options: a) Chilled Water (Shown): - 12 Fans, 8 Coils b) Outside Air: - 10 Fans, Evaporative Media Designed for Indoor or Outdoor deployment Flexible Whitespace Options Camera Options: - Prewire: Standard - BASELAYER Camera Installed - Customer Specified Camera Installed Access Control Options: - Prewire: Standard - BASELAYER Card Reader Installed - Customer Specified Access Control Installed Cooling Options: - Chilled Water - Outside Air with Evaporative Media

BASELAYER EDGE LM Data Module: Configured to Meet Rack and Density Requirements EDGE LM3 60 x 52U cabinets 8.3kW/rack @ N EDGE LM5 110 x 52U cabinets 4.5kW/rack @ N 60 racks 110 racks LM2 35 x 52U cabinets 14.3kW/rack @ N 35 racks 85 racks EDGE LM4 85 x 52U cabinets 5.9kW/rack @ N Chilled Water Configuration Shown

BASELAYER EDGE XLMA Series Data Module HIGHLIGHTS Delivers up to 500kW of Critical IT Power and Cooling for rack configurations of 35 (XLMA2 Shown), 60, 85 or 110, 52U racks @ N. Engineered to meet NEMA 4 compliance standards for deployment in all global environments. Ships configuration tested from the factory with RunSmart TM Embedded providing access to key module sensors and controls via a web-based server. Power and cooling redundancy thresholds are configurable through BASELAYER RunSmart TM OS, SPECIFICATIONS Exterior Dimensions Length 42 8 (13.00m) All US (Metric) Height 13 3 ( 4.03m) All Width 34 0 (10.36m) XLMA2 44 6 (13.56m) XLMA3 55 0 (16.76m) XLMA4 65 6 (19.96m) XLMA5 Whitespace Dimensions Length 41 8 (12.70m) All US (Metric) Height 9 4 ( 2.84m) All Width 21 6 ( 6.55m) XLMA2 32 0 ( 9.75m) XLMA3 42 6 (12.95m) XLMA4 53 0 (16.15m) XLMA5 # of Std. Cabinets (34) 24" (609.6mm), 52U XLMA2 (58) 24" (609.6mm), 52U XLMA3 (82) 24" (609.6mm), 52U XLMA4 (106) 24" (609.6mm), 52U XLMA5 11 8 /3.55m 12 8 /3.96m Voltage/Frequency Power Distribution (IT) Cooling Mechanics 480 V, 3 Phase, 4 Wire, 60Hz 400 V, 3 Phase, 3 Wire, 50Hz Up to 2000A per Busway Outside Air Heat Removal 10 Fans with Evaporative Media Leak Detection Strip Leak Detection (4 total)

BASELAYER EDGE XLMA Series Data Module SYSTEM PERFORMANCE System PUE Range As low as 1.05 (Dependent upon Environmental and Operational Conditions) Maximum Module Capacity @ N @ N+1 @ 2N Maximum Available kw 500kW MAX CAPACITY @ 30 T 500kW MAX CAPACITY @ 30 T 250kW MAX CAPACITY @ 30 T Access Control (Options Available) Control Fire System Dedicated Fire System Fire Rating Compartmentalized Architecture Role-based Access Control Layers of Physical & Logical Protection Separate Tech, & Support Space Access Dedicated 4-wire loop to signaling devices and initiating devices, with all batteries, amplifiers, transponders provided for a fully addressable fire alarm system. Pre-Discharge Alarm & Strobe Light 1 Hour BASELAYER RunSmart TM OS(Optional) Intelligent Control Customizable: Role-based Visibility, Warnings, Alarms, Thresholds & Control Set Points Available (UI) User Visualizer Desktop and Mobile, Business Reporting, API Interfaces Provides Real-time Visibility, Control, Optimization, and Automation Environmental Operating Conditions Operating Temp -30 F (-34 C) to 120 F (48.9 C) Operating Humidity 0 to 100% (RH) Listings, Regulatory Compliance, Certifications UL/CE UL 2755 or CE Compliant (As Regionally Appropriate, Certification Options Available ) NFPA Compliant NEMA 4 Engineered to Meet Standard Support Maintainability Warranty Concurrently Maintainable Standard 1 year limited warranty; upgradable to 3 year limited warranty