HP BLc QLogic 4X QDR InfiniBand Managed Switch and InfiniBand Switch Management Module Installation Guide

Similar documents
F5 Platforms: FIPS Administration. Version

BIG-IP Platform: FIPS Administration. Version 12.1

AXIS T W Splitter 12/24 V DC

AXIS M11 Network Camera Series AXIS M1124 Network Camera AXIS M1125 Network Camera

Avaya 1200 Series Expansion Module for SIP Software User Guide

HP Ethernet 1Gb 2-port 332T Adapter User Guide

QuantaPlex Series T41S-2U/T41SP-2U

AXIS V59 Series AXIS V5915 Network Camera

UPG173RM17A1URackmount Console User Guide

AT-8900, AT-9900, AT-9900s Switches Removable Power Supply and Fan Installation Guide

[ Quick Start Guide ]

Rimage 2000i User Guide

HP BLc QLogic 4X QDR InfiniBand Switch Release Notes. Firmware Version

QuantaGrid Series D51BP-1U Energy Efficient 2-Socket Server with Extreme Storage IOP/S User s Guide

Installation Guide AVA-2902E/I. PCI-to-Fast SCSI Host Adapters. PCI SCSI Host Adapter with Internal or External Connector

INSTALLATION GUIDE. AXIS Q60-S Series AXIS Q6045-S PTZ Dome Network Camera

Product Safety and Regulatory Compliance

Stacking Module. Installation Guide AT-MCF2000S. PN Rev A

IP Phone 1200 Series User Guide. IP Phone 1200 Series Business Communications Manager

INSTALLATION GUIDE ADAPTEC SCSI CARD 29320LP

INSTALLATION GUIDE. AXIS Q7920 Chassis

Safety and Radio-Frequency Interference

COMPACT IP DECT BASE STATION DATA SHEET

External Portable. HP SimpleSave. Portable Hard Drive User Manual. SimpleSave

HP ProLiant NC1020 Cu Gigabit Server Adapter 32 PCI Single Port User Guide. June 2007 (Second Edition) Part Number B

HP 10GbE Pass-Thru Module

HP Jet Fusion 3D Printing Solution. Legal Information

NANOPTIX HEAVY DUTY KIOSK REGULAR CUTTER PRINTER Thermal Print Mechanism Replacement

EZ-LP Quick Start Guide

Installation Guide. Wyse Rx0L Thin Client Flash and RAM Upgrade Option Kit. Issue: PN: L Rev. A

SCSI Cable Installation Instructions

USER MANUAL. AXIS Q1931 E Thermal Network Camera

FX Supervisory Controller Wireless TEC Option Card Installation Instructions

INSTALLATION GUIDE ADAPTEC SCSI CARD ULTRA160 SCSI CONTROLLER

Preface. Manual Revisions. Trademarks

FX-DIS1710 Local Controller Display Installation Instructions Part No , Rev. B Issued April 2016

NSD/M1 Installation Instructions

QuickSpecs. HP InfiniBand Options for HP BladeSystems c-class. Overview

HP BLc Intel 4X QDR InfiniBand Switch Release Notes. Firmware Version

Rimage Everest Encore Printer User Guide

Infosystem Remote Touchscreen Installation Instructions

IP Phone 1200 Series Installation. IP Phone 1200 Series Business Communications Manager

HP External Personal Media Drive User s Guide

LaserJet Enterprise M607, M608, M609

Bluetooth 2.0+EDR. Bluetooth 2.0+EDR (Enhanced Data Rate)

CSM200 Expansion Tray

SySTIUM TECHNOLOGIES. Assembly Guide. Model 133i

USER MANUAL. AXIS Q6042-E PTZ Dome Network Camera

DATALOCKER H100 ENCRYPTED HARD DRIVE. User Guide

HD40H(X) Performance Series Camera. User Guide

2 Mesa Ethernet Dock User s Manual

AT IEEE 802.3af Universal Multi-voltage PoE Splitter. Installation and User Guide. PN Rev A

(US J9426A/B, WW J9427A/B).

Installation. Battery Management System AP9921X AP9921XS

ONCE YOU HAVE READ THIS LICENSE AGREEMENT AND AGREE TO ITS TERMS, YOU MAY USE THE SOFTWARE AND/OR FIRMWARE INCORPORATED INTO THE PARADYNE PRODUCT.

Environmental Monitoring Unit

NCH-1000 (Multiple Breaker Types) Installation Instructions

SANnet II Family Safety, Regulatory, and Compliance Manual

USER MANUAL. AXIS Q6042-C PTZ Dome Network Camera

2.8 December F. Polycom RealPresence Media Suite

68-pin Internal Ultra160-LVD Connector. Adaptec SCSI Card 29160N

AXIS P1427 LE Network Camera. User Manual

AD331A & AD332A PCI-X 1-Port Gigabit Ethernet Card Overview

USER MANUAL. AXIS Q6034-C PTZ Dome Network Camera

AXIS Q1931 E PT Mount Thermal Network Camera

10GbE Pass-Thru Module User Guide

3M Wrist Strap and Ground Monitor 773. User s Guide

3M RFID Tracking Pad Model 770

WILDCAT REALIZM 800 WILDCAT REALIZM 500 WILDCAT REALIZM 200 WILDCAT REALIZM 100

Installing and Configuring Rialto Analytic Appliances

BD FACSMelody Cell Sorter Installation and Security Guide

QUICK GUIDE. AXIS M50 Series. AXIS M5013 PTZ Dome Network Camera AXIS M5014 PTZ Dome Network Camera

201i Server Hardware Installation

QuickSpecs. HPE 10GbE Pass-Thru Module. Overview. What's New. At A Glance

smarttech.com/docfeedback/ USER S GUIDE FOR SMART KAPP iq 55, 65 AND 75 BOARDS

AXIS Q3709-PVE Network Camera. User Manual

AXIS P5522 E PTZ Dome Network Camera. User Manual

AXIS P1405 LE Network Camera. User Manual

2.8.2 November B. Polycom RealPresence Media Suite

Help us make this document better smarttech.com/docfeedback/ USER S GUIDE. FOR MODELS SMART KAPP iq 55 AND 65, AND SMART KAPP IQ PRO 55 AND 65

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

AXIS P5514-E PTZ Network Camera. User Manual

HP D6000 Disk Enclosure Direct Connect Cabling Guide

Quick Start Guide. Sabre 1400 Hand-held Scanner

Raven Series Standalone Media Converters

AXIS Q6000-E Mk II PTZ Network Camera. User Manual

AXIS Q6045-C Mk II PTZ Dome Network Camera

Replacing the Battery HP t5730 and t5735 Thin Clients

AXIS Q8665-E PTZ Network Camera. User Manual

About Your AirPort Card Includes general information about the AirPort Card and AirPort software

AXIS Q1942-E PT Mount Thermal Network Camera

TruVision HD-TVI 720P and 1080P Bullet Camera Installation Guide

CONVERTEON Family. One-Slot Chassis AT-CV1000. Installation Guide Rev. A

AXIS Q6055-C PTZ Network Camera. User Manual

AXIS Q6045-C PTZ Dome Network Camera. User Manual

AXIS M1125 Network Camera. User Manual

HP LaserJet P3005 Series Printers. Getting Started Guide

Envoi Installation and Setup Instructions

HP R1500 G3 UPS User Guide

Polycom RealPresence Media Suite

Transcription:

HP BLc QLogic 4X QDR InfiniBand Managed Switch and InfiniBand Switch Management Module Installation Guide for HP c-class BladeSystems HP Part Number: QL-HWINS-1A Published: Nov. 2009 Edition: 1

Copyright 2009 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. Acknowledgements: InfiniBand is a trademark of the InfiniBand Trade Association. QLogic, the QLogic logo, FastFabric, and vfabric are registered trademarks of QLogic, Inc.

Contents 1 Preparing for Installation............................................... 5 Audience...................................................................... 5 Documentation Resources.......................................................... 5 Kit Contents.................................................................... 5 Additional Information............................................................. 6 Connectors.................................................................... 7 Indicators..................................................................... 7 2 Hardware Installation................................................. 9 Installing an HP BLc QLogic 4X QDR InfiniBand Managed Switch............................... 9 Preparing the Interconnect Module Bay in the HP BladeSystem Enclosure....................... 9 Installing an HP BLc QLogic 4X QDR InfiniBand Managed Switch into an HP BladeSystem Enclosure... 10 Installing InfiniBand Cables in an HP BLc QLogic 4X QDR InfiniBand Managed Switch............... 10 Installing an InfiniBand Cable in an HP BLc QLogic 4X QDR InfiniBand Managed Switch........... 11 Removing an InfiniBand Cable from the HP BLc QLogic 4X QDR InfiniBand Managed Switch.......... 12 InfiniBand Subnet Management..................................................... 12 3 Hardware Removal.................................................. 15 4 Regulatory Compliance............................................... 17 Regulatory Compliance Identification Numbers.......................................... 17 Class A Equipment.............................................................. 17 Modifications.................................................................. 17 Cables...................................................................... 17 Canadian Notice............................................................... 17 European Union Regulatory Notice................................................... 17 Japanese Notice................................................................ 18 Korean Notice................................................................. 18 A Installation of Switch Management Module................................. 19 Figures 1 HP BLc QLogic 4X QDR InfiniBand Managed Switch.................................... 5 2 HP Onboard Administrator Screen Example.......................................... 6 3 QLogic BLc 4X QDR InfiniBand Switch Connector Ports................................... 7 4 QLogic BLc 4X QDR InfiniBand Switch Indicators....................................... 7 5 Removing a Divider from the HP BladeSystem Enclosure Interconnect Module Bay................ 9 6 Installing an HP BLc QLogic 4X QDR InfiniBand Managed Switch into an HP BladeSystem Enclosure.. 10 7 QSFP InfiniBand QDR/QDR Cable............................................... 11 8 Install InfiniBand Cable in an HP BLc QLogic 4X QDR InfiniBand Managed Switch Port........... 12 9 InfiniBand Cable Installed in Port 1 of an HP BLc QLogic 4X QDR InfiniBand Managed Switch...... 12 10 Location of the Switch Management Module Blank Cover................................ 19 11 Switch Management Module Assembly............................................. 19 12 Switch with Switch Management Module........................................... 20 13 Switch with Switch Management Module Cover Removed................................ 21 Tables 1 QLogic BLc 4X QDR InfiniBand Switch Connector Ports................................... 7 2 QLogic BLc 4X QDR InfiniBand Switch Indicators........................................ 7 3 QSFP InfiniBand QDR/QDR Cable................................................ 11 HP BLc QLogic 4X QDR InfiniBand Managed Switch and InfiniBand Switch Management Module Installation Guide 3

4

1 Preparing for Installation Audience This document is intended for HP service representatives and other persons trained to install hardware options in HP BladeSystem configurations. Such persons are expected to understand the hazards of working in this environment and to take suitable precautions to minimize danger to themselves and others. Documentation Resources You can download the documentation for components referenced in this installation guide from the HP BladeSystem Technical Resources website: http://h71028.www7.hp.com/enterprise/cache/499697-0-0-0-121.html The following related documents can also be found at the above website: HP BLc QLogic 4X QDR InfiniBand Managed Switch and InfiniBand Switch Management Module User Guide HP BLc QLogic 4X QDR InfiniBand Managed Switch and InfiniBand Switch Management Module CLI Reference Guide Kit Contents Check the HP BladeSystem Technical Resources website frequently for updates. The kit contains the following items: An HP BLc QLogic 4X QDR InfiniBand Switch for HP c-class BladeSystems (505958-B21) An optional InfiniBand Switch Management Module (505959-B21) for the HP BLc QLogic 4X QDR InfiniBand Switch for HP c-class BladeSystems See Figure 1. This hardware installation document Warranty documentation NOTE: This kit does not include any subnet manager software, InfiniBand cables, or cable management brackets. You must install the QLogic Fabric Manager on this switch, a subnet manager on a host node, or install an internally managed InfiniBand interconnect to manage the InfiniBand fabric. You must also order InfiniBand cables and cable management brackets separately. Figure 1 HP BLc QLogic 4X QDR InfiniBand Managed Switch HP BLc QLogic 4X QDR InfiniBand Managed Switch and InfiniBand Switch Management Module Installation Guide 5

Additional Information Mezzanine card installation determines bay assignments for interconnect module installation. For more information on the association between the mezzanine connector and the interconnect bays, see the following documentation: HP BladeSystem c7000 Enclosure Setup and Installation Guide HP BladeSystem c3000 Enclosure Setup and Installation Guide HP BLc QLogic 4X QDR InfiniBand Switch Cable Management Kit Installation Guide For specific port connections for each server blade, see the HP BladeSystem Onboard Administrator User Guide. Connections differ by blade type. The information in this guide explains cabling between an HP BLc QLogic 4X QDR InfiniBand Managed Switch and the network switches. The HP Onboard Administrator screen example (see Figure 2) is a reference for port mapping. Figure 2 HP Onboard Administrator Screen Example NOTE: The HP's Onboard Administrator (OA) will not distinguish between a managed switch and a non-managed switch. You can install up to 16 InfiniBand cables in the uplink ports on a QLogic BLc 4X QDR InfiniBand Switch. An external subnet manager (not included with a QLogic BLc 4X QDR InfiniBand Switch) manages the topology for the InfiniBand fabric. 6 Preparing for Installation

Connectors Figure 3 shows the Quad Small Form-factor Pluggable (QSFP) connector ports and Table 1 describes the connectors on the front panel of the QLogic BLc 4X QDR InfiniBand Switch. ❶ ❷ ❸ ❹ Figure 3 QLogic BLc 4X QDR InfiniBand Switch Connector Ports Table 1 QLogic BLc 4X QDR InfiniBand Switch Connector Ports Indicators Item Number Description 1 Uplink connectors, ports 1-4 2 Uplink connectors, ports 5-8 3 Uplink connectors, ports 9-12 4 Uplink connectors, ports 13-16 Figure 4 shows the Indicators and Table 2 describes the indicators on the front panel of a QLogic BLc 4X QDR InfiniBand Switch. ❷ ❸ ❸ ❶ Figure 4 QLogic BLc 4X QDR InfiniBand Switch Indicators Table 2 QLogic BLc 4X QDR InfiniBand Switch Indicators Item Number Description Status 1 Module Status Green = Normal operation Amber = Degraded condition Off = Power off 2 Module locator (UID) Blue = Module ID selected Off = Module ID not selected 3 Port state Green = Port is active Off = Port not active HP BLc QLogic 4X QDR InfiniBand Managed Switch and InfiniBand Switch Management Module Installation Guide 7

8 Preparing for Installation

2 Hardware Installation This chapter contains the following sections: Installing an HP BLc QLogic 4X QDR InfiniBand Managed Switch Installing InfiniBand Cables in an HP BLc QLogic 4X QDR InfiniBand Managed Switch Removing an InfiniBand Cable from the HP BLc QLogic 4X QDR InfiniBand Managed Switch InfiniBand Subnet Management Installing an HP BLc QLogic 4X QDR InfiniBand Managed Switch To install an HP BLc QLogic 4X QDR InfiniBand Managed Switch, follow the steps in the following subsections. CAUTION: All panels and doors should be in place and securely fastened while the unit is in operation for proper cooling and for EMI emissions control. Preparing the Interconnect Module Bay in the HP BladeSystem Enclosure To prepare the interconnect module bay in an HP BladeSystem enclosure, follow these steps: 1. Remove any devices or blanks. 2. To remove the divider, press the divider release button (see callout 1 in Figure 5) and slide the divider out of the interconnect module bay (see callout 2 in Figure 5). Figure 5 Removing a Divider from the HP BladeSystem Enclosure Interconnect Module Bay HP BLc QLogic 4X QDR InfiniBand Managed Switch and InfiniBand Switch Management Module Installation Guide 9

Installing an HP BLc QLogic 4X QDR InfiniBand Managed Switch into an HP BladeSystem Enclosure To install an HP BLc QLogic 4X QDR InfiniBand Managed Switch into an HP BladeSystem enclosure, follow these steps: 1. Slide the HP BLc QLogic 4X QDR InfiniBand Managed Switch all the way into the HP BladeSystem enclosure (see callout 1 in Figure 6). Figure 6 Installing an HP BLc QLogic 4X QDR InfiniBand Managed Switch into an HP BladeSystem Enclosure 2. Push the blade handle in until it is in the locked position (see callout 2 in Figure 6). The blade handle is locked when you cannot pull it back out without pushing the blade handle release. Installing InfiniBand Cables in an HP BLc QLogic 4X QDR InfiniBand Managed Switch Figure 7 shows and Table 3 defines an InfiniBand cable with a QSFP connector used with an HP BLc QLogic 4X QDR InfiniBand Managed Switch. QSFP connector to QSFP connector InfiniBand QDR/QDR cables are used to connect multiple HP BLc QLogic 4X QDR InfiniBand Managed Switches together. For more information about supported Infiniband cables, see the HP InfiniBand Options for HP ProLiant and Integrity Servers Quickspec on the HP website: http://h18000.www1.hp.com/products/quickspecs/13078_div/13078_div.html 10 Hardware Installation

Figure 7 QSFP InfiniBand QDR/QDR Cable Table 3 QSFP InfiniBand QDR/QDR Cable Item Number Description 1 InfiniBand cable 2 QSFP connector release pull tab 3 QSFP connector NOTE: The InfiniBand cables are not included in this kit and must be purchased separately. When the HP BLc QLogic 4X QDR InfiniBand Managed Switches are connected together with the QSFP to QSFP InfiniBand cables it forms an InfiniBand high-performance network (also referred to as an InfiniBand fabric). For more information about InfiniBand networks, see InfiniBand support for HP ProLiant and HP Integrity servers on the HP website: http://h20311.www2.hp.com/hpc/cache/595863-0-0-0-121.html Installing an InfiniBand Cable in an HP BLc QLogic 4X QDR InfiniBand Managed Switch To install an InfiniBand cable in an HP BLc QLogic 4X QDR InfiniBand Managed Switch, follow these steps: HP BLc QLogic 4X QDR InfiniBand Managed Switch and InfiniBand Switch Management Module Installation Guide 11

1. Align the InfiniBand cable QSFP connector (see callout 1 in Figure 8) with the HP BLc QLogic 4X QDR InfiniBand Managed Switch port (see callout 2 in Figure 8). Figure 8 Install InfiniBand Cable in an HP BLc QLogic 4X QDR InfiniBand Managed Switch Port 2. Insert the QSFP connector into the HP BLc QLogic 4X QDR InfiniBand Managed Switch port (see callout 1 in Figure 9) until it is fully engaged and locked. Figure 9 InfiniBand Cable Installed in Port 1 of an HP BLc QLogic 4X QDR InfiniBand Managed Switch You can install up to 16 InfiniBand cables in an HP BLc QLogic 4X QDR InfiniBand Managed Switch. It is not necessary to install the InfiniBand cables in any particular order. However, for the sake of consistency, begin installing the InfiniBand cables in port 1 and continue installing the cables up to port 16. Removing an InfiniBand Cable from the HP BLc QLogic 4X QDR InfiniBand Managed Switch To remove an InfiniBand cable from an HP BLc QLogic 4X QDR InfiniBand Managed Switch, pull the QSFP connector release tab (see callout 2 in Figure 7), which releases the connector while using your other hand to remove the connector from the switch port. InfiniBand Subnet Management The HP BLc QLogic 4X QDR InfiniBand Managed Switch has the capability to have the QLogic Fabric Manager installed for managing and troubleshooting the switch. All InfiniBand networks require a subnet manager to manage, monitor, and troubleshoot the InfiniBand fabric. 12 Hardware Installation

The QLogic Fabric Manager is required for managing and troubleshooting an HP BLc QLogic 4X QDR InfiniBand Managed Switch. A subnet manager can be host-based (installed and run on a host node connected to the InfiniBand fabric). You can also use a switch-based subnet manager when certain managed switches are incorporated into the InfiniBand fabric. For more information about InfiniBand subnet management, see the InfiniBand interconnect documentation that came with your system or cluster. Also see the HP InfiniBand Options for HP ProLiant and Integrity Servers Quickspec on the HP website: http://h18000.www1.hp.com/products/quickspecs/13078_div/13078_div.html HP BLc QLogic 4X QDR InfiniBand Managed Switch and InfiniBand Switch Management Module Installation Guide 13

14 Hardware Installation

3 Hardware Removal Put the HP BladeSystem enclosure into a safe and stable state for component removal and bring the component to an appropriate state for removal. You must ensure that you can reach the component easily and handle it safely. For more information about removing c-class components from the c-class enclosure, see the HP BladeSystem Enclosure Service and Maintenance Guide: http://h20000.www2.hp.com/bc/docs/support/supportmanual/c00714237/c00714237.pdf To remove an HP BLc QLogic 4X QDR InfiniBand Managed Switch, follow these steps: 1. Disconnect and remove each InfiniBand cable until all of the networking ports are unplugged. When disconnecting the cables, ensure that you do not bend them more than the recommended bend radius. It might be necessary to loosen the releasable cable ties enough to remove the cable from the switch. HP recommends that you do not remove the cables from the releasable cable ties on the c-class cable management bracket. 2. Remove the cable management bracket, but do not remove the cables from the bracket. 3. Press the switch blade handle release button and slide the switch all the way out of the HP BladeSystem enclosure. NOTE: HP provides various cable management solutions. Installation and removal of the HP BLc QLogic 4X QDR InfiniBand Managed Switch might depend on which type of cable management bracket is used to support the InfiniBand cables used in your configuration. If you are unsure of the process to remove a switch for service, contact an HP service representative. Also check the HP BladeSystem Technical Resources website frequently for updates to this guide: http://h71028.www7.hp.com/enterprise/cache/316735-0-0-0-121.html HP BLc QLogic 4X QDR InfiniBand Managed Switch and InfiniBand Switch Management Module Installation Guide 15

16 Hardware Removal

4 Regulatory Compliance The chapter lists all of the regulatory notices of compliance for the HP BLc QLogic 4X QDR InfiniBand Managed Switch. Regulatory Compliance Identification Numbers For the purpose of regulatory compliance certifications and identification, this product has been assigned a unique regulatory model number. The regulatory model number can be found on the product nameplate label, along with all required approval markings and information. When requesting compliance information for this product, always refer to this regulatory model number. The regulatory model number is not the marketing name or model number of the product. Class A Equipment This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at personal expense. Modifications Cables The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by Hewlett-Packard Company may void the user s authority to operate the equipment. Connections to this device must be made with shielded cables with metallic RFI/EMI connector hoods in order to maintain compliance with FCC Rules and Regulations. Canadian Notice This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. European Union Regulatory Notice This product complies with the following EU Directives: Low Voltage Directive 2006/95/EC EMC Directive 2004/108/EC Compliance with these directives implies conformity to applicable harmonized European standards (European Norms) which are listed on the EU Declaration of Conformity issued by Hewlett-Packard for this product or product family. HP BLc QLogic 4X QDR InfiniBand Managed Switch and InfiniBand Switch Management Module Installation Guide 17

This compliance is indicated by the following conformity marking placed on the product: T his marking is valid for non-telecom prod ucts and EU harmonized Telecom products (e.g. Bluetooth). xxxx* This marking is valid for EU non -harmonized Telecom products. *Notified bod y number (used only if ap plicable - refer to the product label) Hewlett-Packard GmbH, HQ-TRE, Herrenberger Strasse 140, 71034 Boeblingen, Germany The official EU CE declaration of conformity for this device may be found at http://www.hp.com/go/certificates Japanese Notice JAPANESE NOTICE Korean Notice この装置は クラスA 情報技術装置です この装置を家庭環境で使用すると電波妨害を引き起こすことがあります この場合には使用者は適切な対策を講ずるよう要求されることがあります VCCI-A 18 Regulatory Compliance

A Installation of Switch Management Module This appendix provides the procedures for installing the Switch Management Module. The Switch Management Module is not a Field Replaceable Unit (FRU) and is installed in the managed version of the HP BLc QLogic 4X QDR InfiniBand Managed Switch. To install the Switch Management Module in an HP BLc QLogic 4X QDR InfiniBand Managed Switch, follow the steps below: 1. Unscrew and remove the screw (see callout 1 in Figure 10) on the blank cover (see callout 2 in Figure 10). Place the screw to the side to be reused. 1 2 Figure 10 Location of the Switch Management Module Blank Cover. 2. Remove the blank cover (see callout 2 in Figure 10) and discard. 3. Insert the Switch Management Module Assembly (Figure 11) on the switch at the pivot points (see callout 1in Figure 12). 1 Figure 11 Switch Management Module Assembly HP BLc QLogic 4X QDR InfiniBand Managed Switch and InfiniBand Switch Management Module Installation Guide 19

1 Figure 12 Switch with Switch Management Module 20 Installation of Switch Management Module

4. Close cover slowly, ensuring that the module connectors (see callout 1 in Figure 11) connect to the motherboard connectors (see callout 1 in Figure 13). 1 Figure 13 Switch with Switch Management Module Cover Removed 5. Replace the screw that was removed in step 1 (see callout 1 in Figure 10) and tighten securely. HP BLc QLogic 4X QDR InfiniBand Managed Switch and InfiniBand Switch Management Module Installation Guide 21

22 Installation of Switch Management Module

*QL-HWINS-1A* QL-HWINS-1A

Figures 1 HP BLc QLogic 4X QDR InfiniBand Managed Switch.................................... 5 2 HP Onboard Administrator Screen Example.......................................... 6 3 QLogic BLc 4X QDR InfiniBand Switch Connector Ports................................... 7 4 QLogic BLc 4X QDR InfiniBand Switch Indicators....................................... 7 5 Removing a Divider from the HP BladeSystem Enclosure Interconnect Module Bay................ 9 6 Installing an HP BLc QLogic 4X QDR InfiniBand Managed Switch into an HP BladeSystem Enclosure.. 10 7 QSFP InfiniBand QDR/QDR Cable............................................... 11 8 Install InfiniBand Cable in an HP BLc QLogic 4X QDR InfiniBand Managed Switch Port........... 12 9 InfiniBand Cable Installed in Port 1 of an HP BLc QLogic 4X QDR InfiniBand Managed Switch...... 12 10 Location of the Switch Management Module Blank Cover................................ 19 11 Switch Management Module Assembly............................................. 19 12 Switch with Switch Management Module........................................... 20 13 Switch with Switch Management Module Cover Removed................................ 21

Tables 1 QLogic BLc 4X QDR InfiniBand Switch Connector Ports................................... 7 2 QLogic BLc 4X QDR InfiniBand Switch Indicators........................................ 7 3 QSFP InfiniBand QDR/QDR Cable................................................ 11