50W PFC MEDICAL ATX POWER SUPPLY FEATURES +5V Stand-by and Remote ON/OFF U, 50W convection cooled with ATX Input Active PFC for medical purpose Power good / Power fail signal Thermal protection EN 6060-, 3rd edition RoHS compliant DESCRIPTION The ATX power supply MPM-85H is a 50W medical device Short Circuit Protection: The PSU will go into hiccup mode against with active PFC for computerised medical applications. This short circuit or over load conditions and will auto-recovery while faulty power supply is EN 6060-, 3rd edition approved and has a conditions are removed very high quality standard and thermal protection. The device Power ON/OFF: The PSU will be turned on when the power ON/OFF utilizes a thermally efficient U channel chassis design and pin is connected to secondary GND convection cooling. Over Voltage Protection: If for some reason the PSU fails to control itself, the build-in over voltage protection circuit will shut down the SPECIFICATION Input Voltage: 90 ~ 264VAC, Continuous input range Input Frequency: AC Input 47-63Hz Hold-up Time: 6ms, Nominal AC input voltage (5VAC, rated load) Inrush Current: Max. 30/60A; Nominal AC input voltage (5VAC/230VAC) one cycle at 25 C Input Current: Max. 4/2A; Nominal AC input voltage (5VAC/230VAC), rated load Efficiency: Nom. 75%, rated load, 5VAC Varies with distribution of loads among output Input Protect: Non-user serviceable internally located AC input line fuse Total Regulation: On condition of a setting output voltage, input voltage from 90-264VAC and output from 0W to 400W Remote Voltage Sense: Compensates for wire drop Warranty: 24 months Storage Temperature: Min. -20 C / Max. +70 C outputs to prevent damaging external circuits. The trigger point is about 5.8-6.4V at +5V. If the OVP occur, PSU cannot be recovered. Over Temperature Protection: When the PSU is operating over the temperature or over load limit, the device will be shut down automatically to protect itself. The protection point is at the temperature of the HS over 0 C. After temperature of HS going down, the power supply will restart automatically. Relative Humidity: Min. 5% / Max. 95% RH, non-condensing Altitude: Operating: Max. 0K Feet, non-operating: Max. 40K Operating Temperature (without the optional top cover ie open frame): Derate linearly above 50 C by 2.5% per deg C to a max. temperature of 70 C. At 00% Load: Max. +50 C - At 50% Load: Max. +70 C Operating Temperature (with the top cover): 30 C at 00% rated load, 40 C at 90% rated load and 50 C at 70% rated load as derating curve. (Please see Note 5 below.) Turn-on Delay: Min. 0.3 sec. / Max. 6 sec.; Time required for initial output voltage stabilization
50W PFC MEDICAL ATX POWER SUPPLY SPECIFICATION Approvals: IEC 6060-, 3rd edition CB approved EN 6060-, 3rd edition TUV approved UL 6060-, st edition, 2006-04-26 UL approved CAN/CSA-C22.2 No. 60.-M90, 2005 cul approved EMI: EN 6060--2:200 Class B PFC: EN 6000-3-2: 2000 & EN 60003-3:200 Class D EMS: IEC 6000-4-2:2004 8kV air discharge, 6kV contact discharge Level 3 IEC 6000-4-3:2002 3m/V Level 3 IEC 6000-4-4:2004 2kV line & PE Level 3 IEC 6000-4-5:200 kv line to line, 2kV line to PE Level 3 IEC 6000-4-6:2004 3V/m Level 3 IEC 6000-4-8:200 3A/m Level 3 IEC 6000-4-:2004 Voltage / Current Rating Chart: Measured at output power connector Model Voltage Min. Current Rated Current Max. Current (Note ) Line Regulation Load Regulation Ripple & Noise (Note 2) Initial Setting Accuracy (Note 3) MPM-85H +5V A A 4A +/- % +/- 2% 50mV 5.05V to 5.5V MPM-85H +2V 0A 5A 0A +/- % +/-4% 00mV.6V to 2.6V MPM-85H -2V 0A 0.5A A +/- % +/-5% 50mV -.4V to 2.6V MPM-85H +3.3V 0A 7.5A 2A +/- % +/- 4% 50mV 3.2V to 3.4V MPM-85H +5Vsb 0A 0.75A.5A +/- % +/- 4% 00mV 4.8 to 5.2V NOTE: Total Power: 50W at 50 C environment temperature (Note 4) ) The maximum total combined output power on the +3.3V and +5V rails is 90W 2) Measured by a 20MHz bandwidth limited oscilloscope, each output is connected with a 0ìF electrolytic capacitor and a 0.ìF ceramic capacitor. 3) Initial setting accuracy is at input 0VAC and all output at 60% rated load. 4) The total DC continuous power shall be kept with 50W at input voltage at 0-264VAC. With input voltage 90-09VAC the total DC continuous power shall be kept with 20W max. The maximum total combined output power on the +3.3V and +5V rails is 90W. On condition of with the option cover, the maximum 50W is at 30 C environment temperature (Please see operating temperature). 5) To order unit with top cover, please add suffix -C to the required model number, eg MPM-85H-C
50W PFC MEDICAL ATX POWER SUPPLY Operating Temperature Curve (without the option cover (open frame) Operating Temperature Curve (with the top cover version) Connector: CN - AC Input CN3 - DC CN4 - Fan CN5 - PG/PF CN6 - PS ON/OFF CN7 - +5Vsb output 3 positions terminal blocks 8 positions terminal blocks Pin Assignment: CN Pin. L 2. N 3. GND CN3 Pin. -2V 2. GND 3. +3.3V 4. GND 5. +5V 6. +5V 7. +2V 8. GND CN4 Pin. +2V 2. GND CN5 Pin. +5V 2. GND CN6 Pin. +5Vsb 2. GND
50W PFC MEDICAL ATX POWER SUPPLY Mechanical Drawings: 98 (L) x 97 (W) x 40.5 (H)mm, Tolerance +/- 0.4mm ( U-Channel) CN3 8 7 6 5 4 3 2 CN5 CN6 CN7 CN4 CN 3 2 Use M3 screw Protrusion limlt 2.5mm x 6 Measuring the screw protrusion f Customer system chassis SCRE W irst:
50W PFC MEDICAL ATX POWER SUPPLY Cable: 866-85H
50W PFC MEDICAL ATX POWER SUPPLY Cable: 866-85H-24