SMARTSTART MOTOR STARTERS

Similar documents
Smartstart Control Module

IPS INTELLIGENT PUMP STARTER

EMS 1Ø, 120 ~ 230V, 1/10-25HP 3Ø, 200 ~ 600V, 1/2-300HP

ENERGY MANAGEMENT SOFT-STARTER THE MOST INTELLIGENT SOFT-STARTER YET

FRANKLIN CONTROL SYSTEMS HVAC SMART STARTERS

Q-LINK SMART BYPASS. SIZING INFORMATION TABLE Q-Link Variable Frequency Drive - 3-Phase 208 VAC 230 VAC VAC HP FLA HP FLA HP FLA TECHNOLOGIES

Pump Data Sheet - Patterson HVAC Pumps Company: Intermountain Hydron Name: Cache County Mountain Crest Date: 09/24/2018

SED2 Variable Frequency Drives with Electronic (E) Bypass Options

MODELS DPDT DPDT DPDT-60MS DPDT-60MS

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

PHASE MONITOR RELAYS Product Summary

Installation, Operation and Maintenance Manual

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS

Quick Start Guide TS A

BT300 HVAC Drives Electronic Bypass (E-Bypass) Options

SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options

S.W. Version SubMonitor Connect Installation & Operation Manual

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

MODERNIZE YOUR DC CRANES. Convert Your DC Controls to State-of-the-Art Energy Efficient OmniPulse DDC Series 2 Drives

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

GE Power Management. MMII Intelligent MCC Controller

Controls Enclosed Non-Combination Starters - PESW Series

SED2 VFD NEMA Type 3R Bypass/Air Conditioner

JK Series POWER DISTRIBUTION. Solid State Starters Medium Voltage A

SP SP-T-9

TECHNICAL BROCHURE BCPNEMAST R0. NEMA Rated Three-Phase Starters BY EATON

Powered to Perform. Everyday Reliability. Exceptional Value. Expertise and Support

For normal duty, design the VFD voltage level at 480 Volt, 3 Phase, 60 Hertz. (In Canada, 600 Volt, 3 Phase, 60 Hertz.)

Table of Contents 1. Overview Installation...6

SED2 Variable Frequency Drives

Mini Contactors & Overloads

RFD-200 TM. Test a Wide Variety of Relays in their Outdo FEATURES AT A GLANCE. Auxiliary AC/DC Power Supply. RFD-200 S2 Ampere Meters

Enclosed DOL Motor Starter Type 4x, Plastic, 3-Phase

SED2 Variable Frequency Drives

Variable Frequency Drive Design Guidelines

LM10 to MM200 Retrofit

Table of Contents. Safety. Attention. Warnings

SLI 15 Inverter Series Data Sheet 1500 Watt, 1U Compact Inverters

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC

Jockey Pump Controllers

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐. Non-Metallic Type 1/12K/IP66 Enclosure (KS7-C0C4R)

INTEGRATED AUTOMATION ACTUATORS AND OPERATORS

SS2200 Remote Controller

VLT 2800 DRIVE SPECIFICATIONS

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp

Industrial Electric Actuators AC and DC Voltages Nm/ inch lbs

Set up and verify the operation of basic motor starters. Understand the purpose of a separate control circuit.

QCPort Cover Control Trouble Shooting Guide

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.

PowerFlex 400 AC Drive Guide Specification

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

APPLICATION CONTROL GUIDELINES. IntelliROL Power Supply PN Revision Date: March 15, 2017

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

PC-200-LLC-GM INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 10/2009 II_PC-XXX-LLC-GM_A1

ETM MD100 Drive System 1/2HP (370W) User Manual. Table of Contents. Drive Features

Compact Electric Actuators AC and DC Voltages 18 Nm/160 inch lbs

ESC 201. Installation and Operating Instructions Manual. SG Jan 2015

ALTERNATING RELAYS & CONTROLLERS ARM Series

FX 2 Instruction Manual

Jockey Pump Controllers

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. MOTOR SYMBOLS. 2010, The McGraw-Hill Companies, Inc.

MODELS: STEAM FIRED YPC-ST-14SC & YPC-ST-16SL Thru YPC-ST-19S

PHASETRONICS. SCR Power Control Specialists. EP1 Series Power Control Single Phase SCR Amps OPERATION & SERVICE MANUAL

Metering Devices, Protective Relays, Software and Connectivity. Pre-Wired Control Power, Voltage and CT Inputs

C. New or replacement products installed in existing facilities shall be consistent with existing equipment.

Trident and Trident X2 Digital Process and Temperature Panel Meter

4/8/ nd Annual OTCO WW Workshop W/WW Product Overview ACQ550. ABB Slide 1

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

PG Softstarter Installation Manual for 5A, 9A and 16A Controllers

Easy To Use OEMS Take Note

INSTALLATION INSTRUCTIONS. Revision C1 Rapid City, SD, USA, 02/2010 MODEL ALT-XXX-3-SW

MAJOR VA Power Inverter

SLI 15 INVERTER SERIES, 1500 W

TeSys IEC Contactors and Overload Relays

The easy to use three-phase digital DC drive for regenerative and non-regenerative applications from HP

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

ADJUSTABLE SPEED DRIVES. Q9 Series

Intelligent Technologies

Wiring Diagrams UNITS WITH STARTING SERIAL NUMBER 3507Q

PEAKTRONICS DHC-100 FEATURES. Digital High-Resolution Controller

Installation Manual Updated May 2017

Flomatic Smart Card TM Model FDHC-100 (Digital High-Resolution Controller) Configuration and Operation Manual

Versatile Safety Interlock Switch with Guard Door Locking

920 Remote Control (RC) Switches

Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ (KS7-C0C4R) Discount Schedule F-1

Compact Coded Magnetic Safety Interlock Switch and Control Units

Power supplies CP-E, CP-S and CP-C range NEW! CP-E Range

LED indicators for normal/fault operating conditions, setup mode, loss of analog signal, and solid-state motor control output.

SED2 VFD NEMA Type 3R and 3R Harsh Environment (3RHE) Bypass Operating Instructions

Magnetic Circuit Protectors 153. Multi-Pole Circuit Protectors 154. APL/UPL, 205/295 Barriers 155. Configurations 156. Operating Characteristics 158

SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

ZC Series Zone Monitoring Controllers

SR489 SR489. Generator Management Relay. Economical protection, metering, and monitoring functions for small and medium sized generators.

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017

Capacitor Switching Contactors

160 AA02SF1 AF DS-D17

Fire Pump Controllers Jockey Pump Controllers

Transcription:

SMARTSTART MOTOR STARTERS MCG WWW.MCG-USA.COM 1

AT A GLANCE Covers all line voltages from 200-600V AC, single or three phase Transformer supplies a 24V AC coil voltage, no matter the line voltage 12V AC/DC - 250V AC/DC still accepted for outside control signal Wide overload range: 1-40A (up to 30HP at 480V AC line voltage) 2 Standard start/stop and remote (HOA) Pilot lights included True line-in and load-out installation Easy integration of remote and automation components Life-time technical support MCG 400 NW. ENTERPRISE DR. (2ND FLOOR), PORT SAINT LUCIE, FL 34986 772-408-5215

MCG SMARTSTART INDUSTRIAL STARTERS One starter. One part number. One solution. All-inclusive starter that reduces inventory by eliminating the need to purchase loose components. SMARTSTART Control Module integrates wide range overload, up to 600V AC voltage input, keypad, and automation I/O WHAT IS SMARTSTART? The patented SMARTSTART control module is an integrated, seamless solution that incorporates operator control, superior motor protection, and automation system compatibility in a rugged, compact unit. It offers a wide-range overload and an extensive array of automation and control features that vary between models. Some of these features include emergency shutdown, damper or valve control, status (proof of flow), fault and shutdown, and more. The SMARTSTART module also accepts an incoming voltage range from 200-600V AC. This is true plug and play; no changing transformers, no messing with terminal blocks. HOW DOES SMARTSTART WORK? SMARTSTART takes an active role in protecting your motor by measuring the motor inrush current and using it to gauge a safe operating range for your motor. In this way it intelligently detects if your motor overload isn t set correctly, protects against locked rotor, cycle fault, stall conditions, and more. The unique functionality of SMARTSTART saves time, labor, and stocking units. It also provides superior motor protection. This is why some of the top manufacturers in America trust SMARTSTART to protect and control their motors. MCG WWW.MCG-USA.COM 3

SMARTSTART FEATURES RELIABLE AND COST-EFFECTIVE INSTALLATION Power failure reset options Direct 200-600V AC connection SmartStart 1-40A electronic protection Automation compatible Integrated keypad with remote Fully compatible with most automation systems Dry inputs - remote run, two external pilot devices, and limit switch input Wet inputs (12-250V AC) - remote run, shutdown Relay output - fault, proof of flow 24V DC output - power actuator Motor Inrush 6-10x FLA Current (amps) Locked Rotor Trip Stall Trip Max Time to Start Trip Wide range of programmable failure modes Pre-select behavior after power failure - restart last mode (no delay), restart with 10 second delay, and restart off FLA Standard Start Curve 1 2 3 4 5 6 7 8 9 10 Start Time (seconds) Locked Rotor Current Motor Never Reaches FLA Typical Motor Stall Current Standard Motor Starting Current 4 MCG 400 NW. ENTERPRISE DR. (2ND FLOOR), PORT SAINT LUCIE, FL 34986 772-408-5215

INDUSTRIAL START/STOP WITH SMARTSTART MOTOR PROTECTION 30, 200~600V AC, 1-40A, AUTOMATION SYSTEM READY Easy integration into existing automation systems Comprehensive input/outputs for building management systems Reduced installation times Patent-pending motor protection Electronic protection including locked rotor, cycle fault, and maximum time to start FLA calibration indicators - ensures overload is correctly calculated Blackbox fault logging Records last 10 start conditions, including FLA setting, max inrush, run current, time to start, and safety start mode Retrievable in factory Included disconnect* Motor circuit protection disconnect provides short-circuit protection No fuses required Proactive alarms Alarms proactively react to preserve motor when operating out-of-range or during failed start-ups Active monitoring Active current monitoring trips faster than standard inverse trip curves, resulting in superior protection against locked rotor and stall conditions UL type 1, 4, and 3R enclosures Lockable enclosures 3R includes lockable keypad cover *Only for Combination version NEMA Sized MCG WWW.MCG-USA.COM 5

SPECIFICATIONS Starter Type MCG - Industrial Start/Stop with SMARTSTART Across the line or Full Voltage Non-Reversing NEMA 1, 3R, OR 4 enclosed Voltage range: 3Ø, 200-600 V AC Amperage range: 1-40A User Interface Start/Stop/Remote keypad with mode LEDs (N1 & 3R), Start/Stop/Remote switch & Run Pilot light (N4) Standard Control Operations Inputs Outputs Operational Environmental 12-250V Remote Apply 12-250V AC/DC to energize Dry Remote Shutdown Limit Switch Internal Pilot Device External Pilot Device Proof of flow current status Starter Fault Damper/Actuator Power fail modes N.O. Dry Contact Apply 12-250V AC/DC to energize N.O. Dry Contact N.O. Dry Contact (N1 & 3R only) N.O. Dry Contact (N1 & 3R only) N.O. Relay Contact Ratings: 110V DC, 0.3A Resistive, 125V DC, 0.5A GP 30V DC, 2.0A Resistive 120V AC 50/60Hz, 0.5A Resistive 125V AC 50/60Hz, 1.0A GP 240V AC 50/60Hz, 0.25A Resistive 24 V DC, 1A maximum Restart last mode, no delay (default) Restart with 10 second delay Restart Off - LED flashes last mode Ambient Operating Temp -5 to 140 F (-20 to 60 C) Ambient Storage Temp -5 to 185 F (-20 to 85 C) Relative Humidity 5% to 95% non-condensing (Nema 1) Motor Protection Adjustment / Description Default Setting Overload Current Setting Range 1-40A Per FLA Overload Trip Class Adjustable: Class 10 or 20, Trip current = 115% of FLA setting Class 10 Cycle Fault Trip if cycle rate exceeds 20 starts/minute Always On Stall Trips within 0.5 seconds (disabled during startup) Always On Smartstart Protection Adjustment / Description Default Setting Current Phase Unbalance Locked Rotor Out of Calibration On/Off Trips within 3 sec @ 25% current unbalance. *Trip threshold changes to 80% unbalance when switched to Off Trips within 0.5 seconds Trips after 10 seconds if the FLA dial setting is incorrect (set above calculated FLA range), ie. Start current is outside of an acceptable range (fla setting * 5 < inrush < fla setting * 14). On Max Time to Start Regardless of FLA or I2t curve, always trip at start if starting current is outside of an acceptable range (inrush / 5) and still decreasing after 10 seconds. 6 MCG 400 NW. ENTERPRISE DR. (2ND FLOOR), PORT SAINT LUCIE, FL 34986 772-408-5215

UL TYPE 1 INDOOR ENCLOSURE STANDARD MOTOR STARTER - 3 PHASE, 200~600 V AC Three Phase HP Contactor 200V 230V 460V 600V NEMA Size Part Number 1 1.5 3 7.5 00 MCG1-9/P-40 3 5 10 15 0 MCG1-18/P-40 7.5 10 20 25 1 MCG1-32/P-40 10 10 30 30 1P MCG1-40/P40 UL TYPE 1 INDOOR ENCLOSURE COMBINATION MOTOR STARTER - 3 PHASE, 200~600 V AC Three Phase HP Contactor NEMA Part Number 200V 230V 460V 600V Size 3/4 3/4 MCG1-9/P-G1.6-40 1/2 1/2 1 1.5 MCG1-9/P-G2.5-40 3/4 3/4 2 3 00 MCG1-9/P-G4-40 1 1.5 3 3 MCG1-9/P-G6-40 2 2 5 5 MCG1-9/P-G8-40 2 3 5 7.5 MCG1-18/P-G10-40 3 3 7.5 10 0 MCG1-18/P-G13-40 3 5 10 15 MCG1-18/P-G17-40 5 7.5 15 20 MCG1-32/P-G22-40 7.5 7.5 15 20 1 MCG1-32/P-G26-40 7.5 10 20 25 MCG1-32/P-G32-40 10 10 30 30 1P MCG1-40/P-G40-40 UL TYPE 3R OUTDOOR ENCLOSURE STANDARD MOTOR STARTER - 3 PHASE, 200~600 V AC Three Phase HP Contactor NEMA Part Number 200V 230V 460V 600V Size 1 1.5 3 7.5 00 MCG3R-9/P-40 3 5 10 15 0 MCG3R-18/P-40 7.5 10 20 25 1 MCG3R-32/P-40 10 10 30 30 1P MCG3R-40/P-40 UL TYPE 3R OUTDOOR ENCLOSURE COMBINATION MOTOR STARTER - 3 PHASE, 200~600 V AC Three Phase HP Contactor NEMA Part Number 200V 230V 460V 600V Size 3/4 3/4 MCG3R-9/P-G1.6-40 1/2 1/2 1 1.5 MCG3R-9/P-G2.5-40 3/4 3/4 2 3 00 MCG3R-9/P-G4-40 1 1.5 3 3 MCG3R-9/P-G6-40 2 2 5 5 MCG3R-9/P-G8-40 2 3 5 7.5 MCG3R-18/P-G10-40 3 3 7.5 10 0 MCG3R-18/P-G13-40 3 5 10 15 MCG3R-18/P-G17-40 5 7.5 15 20 MCG3R-32/P-G22-40 7.5 7.5 15 20 1 MCG3R-32/P-G26-40 7.5 10 20 30 MCG3R-32/P-G32-40 10 10 30 30 1P MCG3R-40/P-G40-40 UL TYPE 4 INDOOR/OUTDOOR ENCLOSURE STANDARD MOTOR STARTER - 3 PHASE, 200~600 V AC Three Phase HP Contactor NEMxA Part Number 200V 230V 460V 600V Size 1 1.5 3 7.5 00 MCG4-9/P-40 3 5 10 15 0 MCG4-18/P-40 7.5 10 20 25 1 MCG4-32/P-40 10 10 30 30 1P MCG4-40/P40 *Consult factory for NEMA 4X enclosure options MCG1-18/P-G17-40 Diconnect Amperage Overload Rating Contactor Size (9, 18, 32, etc.) Enclosure Rating (Type 1, 3R or 4) UL TYPE 4 OUTDOOR ENCLOSURE COMBINATION MOTOR STARTER - 3 PHASE, 200~600 V AC Three Phase HP 200V 230V 460V 600V 3/4 3/4 Contactor NEMA Size Part Number MCG4-9/P-G1.6-40 1/2 1/2 1 1.5 MCG4-9/P-G2.5-40 00 3/4 3/4 2 3 MCG4-9/P-G4-40 1 1.5 3 3 MCG4-9/P-G6-40 2 2 5 5 MCG4-18/P-G8-40 2 3 5 7.5 MCG4-18/P-G10-40 0 3 3 7.5 10 MCG4-18/P-G13-40 3 5 10 15 MCG4-18/P-G17-40 5 7.5 15 20 MCG4-32/P-G22-40 7.5 7.5 15 20 1 MCG4-32/P-G26-40 7.5 10 20 30 MCG4-32/P-G32-40 10 10 30 30 1P MCG4-40/P-G40-40 MCG WWW.MCG-USA.COM 7

MCG (1/3R) WIRING SCHEMATICS ISS(1/3R) CONTROL WIRING 10 15 20 5 25 1 30 Remote Run Voltage Inputs Shut Down 12-250VAC/DC Input 12-250VAC/DC Input ISS STARTER POWER WIRING FLA (A) 40 35 Overload Setting Relay Outputs Status Common Fault OL Keypad PCB Power Pilot Devices Dry Input Actuator Control Contactor Coil Start Remote Remote Run Motor Limit Switch A1 A2 Normally Closed Input Normally Open Input Normally Open Input 24VDC, 1A Output Normally Open Input M 24V Output to contactor coil MCP (Optional) H1 H4 208-600 VAC Input L1 L2 L3 M 43 31 44 32 T1 T2 T3 AUX CONT MTR H1 H4 3PH UL TYPE 1 DIMENSIONS All dimensions are in inches 7 5/8 13 9/16 14 1/8 6 3/8 8 1/16 UL TYPE 3R DIMENSIONS All dimensions are in inches 7 5/8 13 9/16 14 1/8 6 3/8 8 1/16 8 MCG 400 NW. ENTERPRISE DR. (2ND FLOOR), PORT SAINT LUCIE, FL 34986 772-408-5215

MCG4 WIRING SCHEMATICS ISS4 CONTROL WIRING POWER WIRING 10 15 20 5 25 1 30 Remote Run Voltage Inputs Shut Down 12-250VAC/DC Input 12-250VAC/DC Input FLA (A) Keypad PCB Power 40 35 Overload Setting Relay Outputs Pilot Devices Dry Input Actuator Control Contactor Coil Start Remote Remote Run Motor Limit Switch A1 A2 Status Common Fault STOP START REMOTE G Normally Open Input Normally Open Input M X A+ A- 24V Output to contactor coil X 24VDC, 1A Output MCP (Optional) OL H1 200-600 VAC Input L1 H4 L2 L3 M 43 31 44 32 T1 T2 T3 AUX CONT MTR 3PH H1 H4 UL TYPE 4 DIMENSIONS All dimensions are in inches NON-COMBINATION* 10 7/16 7 MTG. 12 5/16 11 MTG. COMBINATION* 6 11/16 7 5/8 6 11/16 8 3/8 *Consult factory for NEMA 4X enclosure options *Combination dimensions are the same as non-combination dimensions except for the depth (shown above, 8 5/8 ). MCG WWW.MCG-USA.COM 9

MCG offers a wide variety of industrial control and automation products as well as custom-built lighting contactors, enclosures, and motor starters. Flexibility allows MCG to create custom solutions for virtually any application. 10 MCG 400 NW. ENTERPRISE DR. (2ND FLOOR), PORT SAINT LUCIE, FL 34986 772-408-5215

MCG WWW.MCG-USA.COM 11

400 NW. ENTERPRISE DR. (2ND FLOOR) PORT SAINT LUCIE, FL 34986 772-408-5215 WWW.MCG-USA.COM 12 MCG 400 NW. ENTERPRISE DR. (2ND FLOOR), PORT SAINT LUCIE, FL 34986 772-408-5215 A DIVISION OF