Series AMEL5-MAZ 5 Watt AC-DC / DC-DC Converter

Similar documents
Series AMEL20-MAZ 20 Watt AC-DC / DC-DC Converter

Series AMEL20-AZ 20 Watt AC-DC / DC-DC Converter

Series AMES40-MAZ 40 Watt AC-DC / DC-DC Converter

Series AMEL10-MJZ 10 Watt AC-DC / DC-DC Converter

Series AME5-CJZ 5 Watt AC-DC / DC-DC Converter

Series AME25-JZ 25 Watt AC-DC / DC-DC Converter

Series AME10-VZ 10 Watt AC-DC / DC-DC Converter

Series AME60-MJZ 60 Watt AC-DC / DC-DC Converter

Series AMEPR30D-AZ up to 2A AC-DC LED driver

Series AMER120-AZ up to 5A AC-DC / DC-DC LED Driver / Converter

Series AMEPR60C-AZ up to 5A AC-DC / DC-DC LED Driver / Converter

Series AM1S-Z 1 Watt DC-DC Converter

Series AM1M-NZ 1 Watt DC-DC Converter

Series AM4T-Z 4 Watt DC-DC Converter

Series AM3G-NZ 3 Watt DC-DC Converter

Series AM20EW-NZ 20 Watt DC-DC Converter

VP ELECTRONIQUE MASSY - Tel

Model No. ( Single Output ) ATC-3.3S ATC-5S ATC-12S ATC-15S ATC-24S Max Output Wattage (W) 10W 10W 10W 10W 10W VAC or VDC

APM-40 SERIES FEATURES PRODUCT OVERVIEW. Model Selection Guide. Input Specifications. AC/DC Power Module 40W, Industrial & Medical Safety

Output Current Input Current Max. capacitive Load

12-15VDC (12V±5%) 24-28VDC (24V±5%)

12-15VDC (12V±5%) 24-28VDC (24V±5%)

AC-DC POWER SUPPLIES UNIVERSAL INPUT, 65 WATT MEDICAL APPLICATIONS MUI65 SERIES

Features. Regulated Converter. RAC35-G/OF 35 Watt 4 x 2 Open Frame RAC35- SG/OF. AC/DC Converter

Universal Power Supplies

Watts. xppower.com. General. Input. Environmental. EMC & Safety. Output. IT & Medical Approvals. Energy Efficiency Level V, CEC2008 & EISA 2007

IEC/EN/UL60950 & CE certified, EN55032 Class B

Universal input VAC <150mW No load power consumption

40 & 60 Watt Models. Low Leakage Current. EN61000 Compliant. Single & Multiple Outputs. Cover Kits Available

Parameter Condition Min. Typ. Max. Internal Input Filter 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

Universal input VAC <250mW No load power consumption -25 C to +80 C Operating temperature, with derating

Parameter Condition Min. Typ. Max. Internal Input Filter. nom. Vin = 230VDC 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

Note1: Typ. efficiency is 230VAC and full load 12VDC 24VDC 48VDC ms 8ms 16ms 80ms

Series Specifications Ta= 25 C, nom. Vin, full load and after warm-up unless otherwise stated) Parameter Condition Min. Typ. Max.

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

C B. Models. Operating up to 5000m altitude 5 year product warranty

MPO-120S Series. Single Output, 180W Compact, Open Frame AC/DC Power Supplies. Key Features:

Constant Voltage Mode

TMP & TMPM Series, 4 to 60 Watt. Order code Output power max. Output Efficiency

C B. Models. Ultra wide 4:1 input voltage 20 W DC/DC. edition and EN55032 class A

FDC20-48 S 05 W - HC PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd.

FEATURES. Nominal Output Voltage and Current

Industrial Power Supplies

Output Voltage* (nom.)(adjustable)

MPM-U653-DCF-B M/N: MPM-U653-DCF-B. 650W Medical AC / DC SPECIFICATION FOR SWITCHING POWER SUPPLY. Revision History

POWERBOX Industrial Line PMR20W Series 20W 4:1 Single and Dual Output High Performance DC/DC Converter

Enclosed Power Supplies

VER05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input. Output

Datasheet. ACF-10 Series AC/DC Power Module 10W

MPU-120S Series. Single Output, 180W Compact, U-Channel AC/DC Power Supplies. Key Features:

MVAD040 Series 40W 2" x 4" AC-DC Power Supply Converter

Features. Applications and Benefits TRC ELECTRONICS, INC

Output Voltage* (nom.)(adjustable)

DC-DC CONVERTERS SINGLE OUTPUT, 60 WATTS EXTREMELY WIDE 12:1 INPUT VOLTAGE RANGE: 9-75VDC, VDC RAILWAY APPLICATIONS

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Industrial Power Supplies

Output Voltage in Constant Voltage Mode. Model Number

Electrical Specification for: efo Wide range AC/DC Single 12V Output 400W Power Supply Telkoor Part Number: CUSTOMER SIZE CAGE CO

TEP 100WIR Series, 100 Watt

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Gelo LED Driver 100W, Single output, Constant Voltage RGLD100-24

Max. Output Power(2) Typical Efficiency (3) 0 ~ 18.4 A 220 W 91.5% 0.96 EBV-250S012SV 0 ~ 10.5 A 250 W 93.0% 0.96 EBV-250S024SV

4:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 88% Over Current and Over Voltage Protection No Minimum Load Required

Chrome Class II DIN Rail Power Supply 24V 10W 1 Phase (NEC Class 2 & Household) / DRC-24V10W1HZ

Industrial Power Supplies

EPT W 5V 2.4A ±5% EPT W 7V 1.71A ±5% EPT W 9V 1.5A ±5% EPT W 12V 1.25A ±5% EPT W 15V 1.0A ±5%

efo Series Wide range AC/DC Single Output 1000W Rugged Power Supply Electrical Specification for: Telkoor Part Number:

Application Package Dimension Output Input Output Output Protection Option Code Code Power Voltage Quantity Voltage Type (W) (VAC) (VDC)

Packaging (5) Protection (3) Isolation Voltage (4)

Max. Output Power. Typical Efficiency (3) 0 ~ 25.0 A 300 W 91.5% 0.96 EBV-350S012SV 0 ~ 14.6 A 350 W 93.5% 0.96 EBV-350S024SV

POWERBOX Medline 150 EBM04 Series W Single Output AC/DC Medical Switch Mode Adaptor, Desktop Style

100BPS15 B. MDS Medical AC-DC Open Frame 15Volt, 100Watt / MDS-100BPS15 B ``` Highlights & Features. Safety Standards.

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

POWERSOLVE ELECTRONICS LTD PSL400-XX series Conduction Cooled Power Supply Engineering Specification

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Chrome DIN Rail Power Supply 12V 72W 1 Phase (Class II) / DRC-12V100W1AZ

RTU500 series Data Sheet Power Supply CP-E 24/2.5

60 Watt Medical (MWLT)

4:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 84% Fixed Operating Frequency Six-Sided Continuous Shield

Ripple & Noise (max) (See Note 2) 5V output: 100mVp-p; 12V - 27V outputs: 150mVp-p; 48V output: 200mVp-p

EMH Series. 250 W & 350 W Forced-cooled. Industry Standard 3 x 5 x 1.43 Format. IT & Medical (BF) Approvals. 80 V VAC Operation

MI1000ERW. Series. Miniature 1 x 1, 2:1 Input, 10W DC/DC Con vert ers. Key Features:

TEP160-WIRCM SERIES 160 Watt High Density Brick DC-DC Converter Measures: 2.40 x 2.28 x 0.50

KEPCO GIVES YOU ZERO-UP PROGRAMMABILITY IN AN AFFORDABLE POWER MODULE

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

Gelo LED Driver 100W, Single output RGLD100-24

Chrome DIN Rail Power Supply 12V 9.96W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1A

Sync DIN Rail Power Supply 5V 15W 1 Phase (NEC Class 2) / DRS-5V30W1NZ

VEL05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input

PXC05-Dual Output Series: DC/DC Converter Module 9 to 75 Vdc input, 3.3 to 15 Vdc Dual Outputs, 5W

MPV1060RI4. Ultra Wide Input, Compact Industrial Grade, PV Power DC/DC Con vert ers. Key Features:

2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 87% Fixed Operating Frequency Six-Sided Continuous Shield

Safety Standards. Model Number:

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

Environmental. Electrical Specifications at 25 O C E Output Constant Current

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1A

Environmental. Electrical Specifications at 25 O C E Output Constant Current

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 95% at 85V AC)

Efficiency (typ.) Load VDC VDC ma ma(typ.) ma(typ.) μf %

040APS12 B MDS. MDS Medical AC-DC Open Frame 12Volt, 40Watt / MDS-040APS12 B ``` Highlights & Features. Safety Standards.

Transcription:

Click on Series name for product info on aimtec.com FEATURES: I/O Isolation 4000 Operating Temp: -40 C to +80 C or -25 C to +80 C Input: 90-264, 47-440Hz, or 130-370VDC Over load, Over, Short Circuit Protection RoHS compliant Energy Star compliant Small package Soft start Models Single output Model Input (/Hz) Input (VDC) Temperature range (ºC) (V) Current max (A) Maximum capacitive Load (µf) Efficiency (%) AMEL5-3.3SMAZ 90-264/47-440 130-370 -40 to +80 3.3 1. 5 2200 71 70 AMEL5-5SMAZ 90-264/47-440 130-370 -40 to +80 5 1 1100 74 74 AMEL5-12SMAZ 90-264/47-440 130-370 -40 to +80 12 0.42 680 77 75 AMEL5-15SMAZ 90-264/47-440 130-370 -40 to +80 15 0.333 330 77 76 AMEL5-24SMAZ 90-264/47-440 130-370 -40 to +80 24 0.21 220 76 75 AMEL5-3.3SEMAZ 90-264/47-440 130-370 -40 to +80 3.3 1. 5 2200 71 70 AMEL5-5SEMAZ 90-264/47-440 130-370 -40 to +80 5 1 1100 74 74 AMEL5-12SEMAZ 90-264/47-440 130-370 -40 to +80 12 0.42 680 76 76 AMEL5-15SEMAZ 90-264/47-440 130-370 -40 to +80 15 0.333 330 76 76 AMEL5-24SEMAZ 90-264/47-440 130-370 -40 to +80 24 0.21 220 76 75 Note: Optional mounting plate version can be ordered by adding -ST suffix to part number (ex. AMEL5-5SMAZ-ST) Models Dual output Model Input (/Hz) Input (VDC) Temperature range (ºC) (V) Current max (A) Maximum capacitive load (µf) F 052e R8.U 1 of 5 North America only 115 230 Efficiency (%) AMEL5-5DMAZ 90-264/47-440 130-370 -40 to +80 ±5 ±0.5 ±470 72 72 AMEL5-12DMAZ 90-264/47-440 130-370 -40 to +80 ±12 ±0.21 ±220 73 73 AMEL5-15DMAZ 90-264/47-440 130-370 -40 to +80 ±15 ±0.168 ±150 72 73 AMEL5-5DEMAZ 90-264/47-440 130-370 -40 to +80 ±5 ±0.5 ±470 72 72 AMEL5-12DEMAZ 90-264/47-440 130-370 -40 to +80 ±12 ±0.21 ±220 73 73 AMEL5-15DEMAZ 90-264/47-440 130-370 -40 to +80 ±15 ±0.168 ±150 72 73 Note: Optional mounting plate version can be ordered by adding -ST suffix to part number (ex. AMEL5-5SMAZ-ST) Input Specifications Current (full load) 115 120 ma 230 70 ma Inrush current <2ms (cold start) 115 15 A 230 30 A Leakage current 0.2 ma External fuse Recommended slow blow type 1.5 A Input Dissipation (No Load) No load (110/230) 0.1 W Start up time Soft Start 780 ms Under Protection 85 Specifications accuracy ±2 % Line regulation ±1 % 115 CB 230

Load regulation (single output) 0-100% load ±1 % Cross Regulation (dual output) 25% load 1 st out, 100% load 2 nd ±5 % out Transient Recovery Time 300 µs Transient Response Deviation 25% load step ±2 % of Vout Minimum load 0 % Ripple & Noise * 3.3 / 5V models 12 / 15V models 75 100 mv p-p 24V 150 Hold-up time (minimum) 15 ms *Ripple and Noise are measured at 20MHz bandwidth by using a 0.1µF (M/C) and 47µF (E/C) parallel capacitor. Isolation Specifications Parameters Conditions Typical Rated Units Tested I/O voltage 60 sec 4000 Isolation Resistance >1000 MΩ General Specifications Switching frequency 132 KHz Protection class Class II Over Load protection Fold back Over voltage protection Zener diode clamp Short circuit protection Auto recovery Operating temperature With derating above 50ºC Refer to the models table above o C Storage temperature -40 to +95 o C Maximum Case temperature 100 o C Temperature coefficient 0.02 % / o C Cooling Free air convection Humidity Non condensing 20 ~ 95 % RH Case material Plastic (flammability to UL 94V-0) Weight 30 g Dimensions (L x W x H) 2.03 x 1.10 x 0.70 inches 51.5 x 28 x 17.8mm MTBF > 400,000 hrs (MIL-HDBK -217F, t=+25 o C)/Full Load > 100,000 hrs (MIL-HDBK -217F, t=at highest operating temperature)/full Load NOTE: All specifications in this datasheet are measured at an ambient temperature of 25 C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Environment Approval Parameters Shock Vibrations Conditions Wave form: Half sine wave Acceleration amplitude: 5gn Bump duration: 30 ms Number of bumps: 18 (3 in each direction for every axis) Converter operation before and after test, body mounted (on chassis) Test mode: Sweep sine 10-100Hz, speed 0.05Hz/s Displacement: 1mm Acceleration: 3g 3 loops 30min one cycle, 3h total, every axis tested Converter operation before and after test, body mounted (on chassis) F 052e R8.U 2 of 5 North America only

Safety Specifications Parameters Agency approvals Standards Dimensions 1.10 (28.00) 0.80 (20.32) 0.11 (2.89) 1 2 culus, CE, CB Medical Electrical Equipment IEC\EN\UL 60601-1, 2 x MOOP, CSA-C22.2 No. 601.1-M90 Information technology Equipment EN 60950-1:2006+A11:2009 EMI - Conducted and radiated emission EN55011, class B with the referenced External EMI circuit Harmonic Current Emissions IEC/EN 61000-3-2, Class A fluctuations and flicker IEC/EN 61000-3-3, (EN60555-3) Electrostatic Discharge Immunity IEC 61000-4-2 Level 3 RF, Electromagnetic Field Immunity IEC 61000-4-3 Level 2 Electrical Fast Transient/Burst Immunity IEC 61000-4-4 Level 3 Surge Immunity IEC 61000-4-5 Level 3 RF, Conducted Disturbance Immunity IEC 61000-4-6 Level 2 Power frequency Magnetic Field Immunity IEC 61000-4-8 Level 2 dips, Short Interruptions Immunity IEC 61000-4-11 2.03 (51.50) 1.80 (45.72) TOP VIEW 3 4 5 0.40 (10.16) 0.40 (10.16) 1 2 TOP VIEW + 3 4 5 Case Temperature Measurement point 17.80 (0.70) 5 Ø- 0.047 (Ø 1.2) DIV: 0.2 (5.08) 0.2 (5.08) (Min) Pin Out Specifications Ø 0.04 (1.00) Pin Single Dual 1 AC Input (N) AC Input (N) 2 AC Input (L) AC Input (L) 3 +V +V 4 -V Common 5 No pin -V Dimensions: inch (mm) Case Tolerance:± 0.02 (0.50) Pin Pitch Tolerance: ± 0.012 (0.30) 100 80 Derating Free Air Convection 50 º C 60 50% Safe Operating Area 70C 40 20 25% 80C 0-25 - 40-20 0 20 40 60 80 100 Ambient Temperature º C F 052e R8.U 3 of 5 North America only

Additional Surge Protective Circuitry The AMEL5-MAZ series design level surge protection is certified to IEC 61000-4-5 surge Line to Line of 1KV. However greater protection can be enhanced by adding protective devices to ingress circuitry. For example, by adding an MOV (Metal Oxide Varistor) device example TVR10471KSY to the N / L input lines 2KV surge protection or greater, can be achieved. L N Fuse MOV + - Vo+ Aimtec AC-DC Converter Vo- Load Vrms Vdc Wmax (2ms) Pmax MOV PN V V J W TVR10471KSY 300 385 70 0.4 F 052e R8.U 4 of 5 North America only

Dimensions of Optional ST Mounting Plate Version 70.00 86.00 Pin Out Specification ST Version 38.00 25.00 AIMTEC NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25 C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec s standard Terms of Sale available at www.aimtec.com. F 052e R8.U 5 of 5 North America only