EZCT S2A. current transformer test set. Vanguard Instruments Company, Inc.

Similar documents
EZCT S2A current transformer test set

EZCT-2000C Plus. current transformer test set. Vanguard Instruments Company, Inc.

EZCT-2000C current transformer test set

EZCT-2KA. current transformer test set

Advanced Test Equipment Rentals ATEC (2832)

ATRT-03B S2. automatic, 3-phase transformer turns ratio tester. Vanguard Instruments Company, Inc.

TRF-250. automatic, 250V, 3-phase transformer ratio finder. Vanguard Instruments Company, Inc.

Tri-Phase. true 3-phase transformer turns ratio tester

CT-6500 S2. digital circuit breaker analyzer. Vanguard Instruments Company, Inc.

IRM-5000P. insulation resistance meter. Vanguard Instruments Company, Inc.

ATRT-03 S2. automatic, 3-phase transformer turns ratio tester

TRF-250. automatic, 3-phase transformer turns ratio finder

CT-7500 S2. Advanced Test Equipment Rentals ATEC (2832) digital circuit breaker analyzer

TRF-250A. automatic, 3-phase transformer turns ratio finder

CT-8000 S3 digital circuit breaker analyzer

DIGITMR S2 PC. digital circuit breaker analyzer. Vanguard Instruments Company, Inc.

CT-8000 S3. digital circuit breaker analyzer

RFD-200 TM. Test a Wide Variety of Relays in their Outdo FEATURES AT A GLANCE. Auxiliary AC/DC Power Supply. RFD-200 S2 Ampere Meters

EZCT-2000A TM DIGITAL CURRENT-TRANSFORMER TESTER

CVT-765 Capacitor Voltage Transformer Ratio Tester

Transducers and Adapters

guidebook SUB-STATION TEST EQUIPMENT condensed edition Vanguard Instruments Company, Inc. Reliability through instrumentation

EZCT-2000B TM DIGITAL CURRENT-TRANSFORMER TESTER

SGT-600 SAFETY GROUND TESTER

ATRT-03 S2, ATRT-03A S2, and ATRT-03B S2 THREE-PHASE TRANSFORMER TURNS-RATIO METERS

Auto-Ohm 200 S3 / DMOM-200 S3 / DMOM-600 True DC Digital Micro-Ohmmeters

EZCT-2000C TM DIGITAL CURRENT-TRANSFORMER TESTER

ATRT-03, ATRT-03A, and ATRT-03B THREE-PHASE TRANSFORMER TURNS-RATIO METERS

MCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER

This Specification Data Sheet brought to you by: Trinity Blvd. Fort Worth, Texas /

VBT-75 S2 VACUUM BOTTLE TESTER

MCCB-250 MOLDED-CASE CIRCUIT BREAKER TESTER

OPERATING PROCEDURES for the UPS-S2 Universal Power Supply Series 2

EZCT-2000 Software. VERSION 2.x USER'S MANUAL

Micro-Ohmmeter. Digital 200A. Model Measure low resistance with high accuracy

CT-7000 S3 DIGITAL CIRCUIT BREAKER ANALYZER

Micro-Ohmmeter. Digital 200A. Model Measure low resistance with high accuracy

3-Phase Transformer Turns Ratio Test Sets

Safely Testing Circuit Breakers Using a Dual Ground Method. With the Vanguard CT-7000 S3 and CT-8000 S3

3-Phase Transformer Turns Ratio Test Sets. n Accurately measures ratio, phase deviation. n Store and download test results in XML format,

3-Phase Transformer Turns Ratio Test Sets

Micro-Ohmmeter. Digital 200A. Model Measure low resistance with high accuracy. Technical Hotline: (800)

Micro-Ohmmeter Model 6290

Circuit Breaker Analyzer & Timer CAT31

Circuit Breaker Analyzer & Timer CAT126

Micro-Ohmmeters. Digital 10A. Models 6240 & Measure low resistance with high accuracy. Selectable test current and resistance ranges

Circuit Breaker Analyzer & Timer CAT126

Circuit Breaker Analyzer & Timer CAT66

Circuit Breaker Analyzer & Timer CAT126

OPERATING INSTRUCTIONS for the CT Digital Circuit Breaker Analyzer

DIGITMR TM DIGITAL CIRCUIT BREAKER ANALYZER

Micro-Ohmmeters. Digital 10A. Models 6240 & Measure low resistance with high accuracy. Technical Hotline: (800)

10A Micro-Ohmmeter Model 6240

The low weight, small size, one-touch solution. Portable appliance testing. The Fluke 6000 series PAT testers

Metered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord

Circuit Breaker Analyzer & Timer CAT65

MJÖLNER 200 Micro-ohmmeter

Circuit Breaker Analyzer System

CBA 1000 CHARACTERISTICS

10 kv Automated Insulation Power Factor Test Set with PowerDB OnBoard. n Integrated PowerDB software package

OPERATING INSTRUCTIONS. For the KNOPP TYPE KCTS-8000 CURRENT TRANSFORMER TESTING SYSTEM. Serial Number: Leaflet Number G.

DCM Dynamic Contact Measuring

DX4085 Z-Meter Tester

DELTA kv Automated Insulation Power Factor Test Set with PowerDB OnBoard DELTA kv Automated Insulation Power Factor Test Set

C100 Portable Multifunction

The low weight, small size, one-touch solution. Portable appliance testing. The Fluke 6000 series PAT testers

MRCT Megger Relay and Current Transformer Test Set

CBA HV Circuit Breaker Analyzer and Microhmmeter

Table of Contents. Automatic Transfer Switch. User Manual ATS-16A/20A/30A/32A

Universal AC Power Source + AC Power Analyzer

Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13

PowerLogic power-monitoring units. EM1000 series power meter. Technical data sheet

VWR BALANCES. A-Series Balances for High Precision with Advanced Features. B2-Series Balances are Rugged, Affordable, and Reliable

Back-UPS RS APC Back-UPS RS 800VA 120V Black

Quattro Flow. Air Velocity Analyzers. Mobile Multipoint Evaluation CAMBRIDGE ACCUSENSE, INC.

Dielectric Withstand and Ground Bond Testers

MJÖLNER 600 Microhmmeter

A P P L I C A T I O N

LOW WEIGHT, SMALL SIZE,

Metered Rack PDU Rack PDU, Metered, Zero U, 5.7kW,208V,(36)C13& (6)C19; 10' Cord

CAPITAL SCALE CC TEL: (012) FAX: CELL: ADVANCED MASS MEASUREMENT

Click Desktop Kit. Click Desktop Kit

1U Rack-Mount Console with 19" LCD, DVI or VGA

First Automated and Self Calibrating Voltage Divider

Multi-Function Ground Resistance Tester Model 6471

Testing Instruments Manufactured by

200A MICRO-OHMMETER ENGLISH. User Manual

WTX110. Legal-for-trade industrial weighing terminal. Special features. Data sheet

VWR BALANCES. A-Series Balances for High Precision with Advanced Features. B2-Series Balances are Rugged, Affordable, and Reliable

DBC 150/650 Series. Druck Dry Block Temperature Calibrators. GE Sensing. Features

Crompton Instruments Ebony Current Transformers

MiniEVR Electronic Voltage Regulator-Power Conditioner (MEVR)

Announcing the Introduction of the New TTR300 Series 3-Phase Transformer Turns Ratio test systems

! Ranges from -45º to 650ºC. ! Rapid heating, cooling and settling. ! Switch test, ramp, step and preset functions

Specifications: Dell 1703FP Flat Panel Color Monitor User's Guide

840CT Battery Discharger &Capacity Tester

CBA 1000 Circuit Breaker Analyzer and MicroOhmmeter

OPERATION MANUAL. separate probe, RS-232 SOUND LEVEL METER. Model : SL-4013

Programmable Switching DC Power Supply

Circuit Breaker Analyzer & Timer CAT-P

Transcription:

EZCT S2A current transformer test set Vanguard Instruments Company, Inc. www.vanguard-instruments.com

EZCT S2A current transformer test set The EZCT S2A is Vanguard s third-generation, microprocessor-based, current transformer test set. The EZCT S2A can perform the current transformer (CT) excitation, CT current-ratio, and winding polarity tests automatically. The EZCT S2A automatically raises and lowers the excitation test voltage without any operator intervention. With up to 1500 Vac excitation test voltage available, the EZCT S2A can easily perform excitation tests on very large CT s. EZCT S2A connections Excitation Test The CT excitation test is performed using the ANSI/IEEE C57.13.1, IEC 60044-1 test method. The test voltage range for the CT excitation test (50 Vac, 250 Vac, 500 Vac, or 1500 Vac) can be selected, and then the test voltage is raised and lowered automatically by the EZCT S2A. The test voltage and current data are collected and stored in the unit s internal memory. Up to 10 CT excitation and current-ratio tests can be stored in one test record. IEEE-30, IEEE-45, ANSI/IEC 60044-1 (10/50) knee point voltages are also calculated and printed on the test report. Once the test is completed, test results can be printed and excitation curves can be plotted on the built-in 4.5-inch wide thermal printer. Thermal Printer A built-in 4.5-inch wide thermal printer can print the current transformer test report and plot the excitation curves. User Interface and Display The EZCT S2A features a back-lit LCD screen (240 x 128 pixels) that is viewable in both bright sunlight and low-light levels. A rugged, alphanumeric, membrane keypad is used to control the unit. CT Ratio and Polarity Tests The EZCT S2A determines the CT current-ratio using the ANSI/IEEE C57.12.90 measurement method. A test voltage is applied to the CT s secondary terminals and the induced voltage is measured through the CT s H1 and H2 terminals. The CT current-ratio and polarity are displayed on the screen and stored in memory. The current-ratio measuring range is from 0.8 to 5,000. The CT winding polarity is displayed as a + sign (in-phase) or a - sign (out-of-phase) and is annotated with the phase angle in degrees. Test Record Header Information The test record header information can include the company name, substation name, circuit ID, manufacturer, CT serial number, operator s name, and test record comments. In addition to the test record header, a 20-character test description for each test in the record can also be entered. ordering information Part number EZCT S2A Part number EZCT-S2A-CASE Part number Paper-TP4 EZCT S2A, cables, and PC software EZCT S2A shipping case thermal printer paper 2

EZCT S2A Controls & Indicators Connector for H Terminals Connector for X Terminals Power Switch Back-lit LCD Screen (240 x 128 pixels) RS-232C PC Interface USB PC Interface 4.5" Wide Thermal Printer Rugged Membrane Keypad USB Flash Drive Interface Test Voltage Presence Indicator Emergency Stop Switch Internal Test Record Storage The EZCT S2A can store up to 140 test records in Flash EEPROM. Each test record may contain up to 10 excitation curves, current-ratio readings, and winding polarity readings. Test records can be recalled and printed on the built-in thermal printer. Internal Test Plan Storage The EZCT S2A can store up to 128 CT test plans in Flash EEPROM. A test plan defines the excitation test voltage and current selection, CT nameplate ratio, and CT winding terminal connection instructions for each test. Up to 10 test definitions can be stored in each test plan. The use of a test plan greatly simplifies the CT testing process since it also provides instructions for making the proper CT cable connections. Test plans can be created on the EZCT S2A itself or created on a PC and downloaded to the EZCT S2A via the unit s built-in RS-232C or USB port. External Data Storage The EZCT S2A features a standard USB Flash drive interface that makes it very convenient to store and transfer test records and test plans. By plugging in a USB Flash drive, you can quickly transfer your test records and test plans between a computer and the EZCT S2A without the need to connect the unit to the computer. Computer Interface The EZCT S2A can be used as a stand-alone unit or can be computer-controlled via the built-in RS-232C or USB interfaces. Windows -based Current Transformer Analysis software is provided with each EZCT S2A. This software can be used to retrieve test records from the EZCT S2A, create test plans, download test plans to the EZCT S2A, and can also be used to run CT tests from the PC. Tabulated test records can be exported in PDF, Excel, and XML formats. EZCT S2A and Tri-Phase at Eskom, South Africa 3

EZCT S2A thermal printer output EZCT S2A desktop printer output 4

Computer control and analysis with included EZCT-2000 Software The EZCT S2A comes with the Vanguard EZCT- 2000 PC software. The EZCT-2000 software can be used to test a current transformer directly from a PC, create and transfer test plans, retrieve test records from the EZCT S2A, and export test records in Excel format for further analysis. EZCT S2A specifications type portable current transformer test set physical specifications 17"W x 12K"H x 12"D (42.7 cm x 32cm x 26.9 cm); Weight: 48 lbs (21 kg) input power 100 120 Vac or 200 240 Vac (factory pre-set), 50/60 Hz measurement method ANSI/IEEE C57.12.90 and ANSI/IEEE C57.13.1 standards output test voltages 0 50 Vac @ 10A max, 0 250 Vac @ 10A max, 0 500 Vac @ 5A max, 0 1500 Vac @ 1.2A max voltage reading range 0 2,200 Vac; Accuracy: ±1.0% of reading, ±1 volt current reading range 0 10A; Accuracy: ±1.0% of reading, ±0.02A current ratio range 0.8 999: 0.1%, 1000 1999: 0.3%, 2000 5000: 1% phase angle measurement 0 360 degrees; Accuracy: ±1.0 degree display Backlit LCD Screen (240 x 128 pixels; 114mm x 64mm); viewable in bright sunlight and low-light levels printer built-in 4.5-inch wide thermal printer computer interfaces one RS-232C port, one USB port external data storage one USB Flash drive interface port (Flash drive not included) pc software Windows -based CT Analysis software is included with purchase price internal test record storage stores 140 test records. Each test record may contain up to 10 sets of excitation, resistance and ratio data internal test plan storage stores 128 test plans. Each test plan can store 10 excitation test voltage and current settings safety designed to meet UL 61010A-1 and CAN/CSA C22.2 No. 1010.1-92 standards environment Operating: -10 C to +50 C (+15 F to +122 F); Storage: -30 C to +70 C (-22 F to +158 F) humidity 90% RH @ 40 C (104 F) non-condensing altitude 2,000 m (6,562 ft) to full safety specifications cables two 20-foot (6.10m) X cable sets, one 35-foot (10.69m) H cable set, power cord, one cable-carrying duffel bag warranty one year on parts and labor NOTE : the above specifications are valid at nominal voltage and ambient temperature of +25 C (+77 F). Specifications are subject to change without notice. 5

Instruments designed and developed by the hearts and minds of utility electricians around the world Vanguard Instruments Company, (VIC), was founded in 1991. Currently, our 28,000 square-foot facility houses Administration, Design & Engineering, and Manufacturing operations. From its inception, VIC s vision was, and is to develop and manufacture innovative test equipment for use in testing substation EHV circuit breakers and other electrical apparatus. The first VIC product was a computerized circuitbreaker analyzer, which was a resounding success. It became the forerunner of an entire series of circuitbreaker test equipment. Since its beginning, VIC s product line has expanded to include microcomputer-based, precision micro-ohmmeters, single and three phase transformer winding turnsratio testers, transformer winding-resistance meters, mega-ohm resistance meters, and a variety of other electrical utility maintenance support products. VIC s performance-oriented products are well suited for the utility industry. They are rugged, reliable, accurate, user friendly, and most are computer controlled. Computer control, with innovative programming, provides many automated testing functions. VIC s instruments eliminate tedious and time-consuming operations, while providing fast, complex, test-result calculations. Errors are reduced and the need to memorize long sequences of procedural steps is eliminated. Every VIC instrument is competitively priced and is covered by a liberal warranty. Vanguard Instruments Company, Inc. 1520 S. Hellman Avenue Ontario, California 91761, USA Phone 909-923-9390 Fax 909-923-9391 www.vanguard-instruments.com August, 2012