USER MANUAL. MODELS 1205 and 1205/34. Synchronous V.35 Modem Eliminators

Similar documents
USER MANUAL MODEL Bidirectional (IEEE-1284) Line Driver/Converter

USER MANUAL MODEL 515 DB-15 Surge Protector

USER MANUAL MODEL 505M-CHC. Surge Protected DB-25 to RJ-45 Modular Adapter

USER MANUAL MODEL 503P & 503PC. Parallel Surge Protectors. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 56X Series 564, 566, 568, 562. Hub Surge Protectors

USER MANUAL. MODEL 2014 Interface Powered RS-530 to V.35 Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL MODEL 536S Token Ring (STP) Surge Protector. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 2011 High Speed Asynchronous to Synchronous Converter

USER MANUAL. MODEL 1018 High Speed Short Range Modem w/ Extra Controls SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 1225 ParaLink TM Parallel Short Range Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)

An ISO-9001 Certified Company

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

USER MANUAL MODEL 571/ Base-T (CAT-5) Surge Protectors. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL MODEL 222N9. Ultra-miniature RS-232 (EIA-574) to RS-422 Interface Converter

USER MANUAL. MODEL 1052 idsl Modem with RS-232 Interface. An ISO-9001 Certified Company SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 1003 and 1003S Asynchronous, 2-Wire, Carrier Sense Short Range Modem

USER MANUAL MODEL KiloModem II AC Powered, High-Speed X.21 Short-Range Modem

USER MANUAL MODEL User Network Access Bridge. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. TS Series (Model 52X) Terminal Strip Surge Protectors. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 552 Series. High Speed Telco Surge Protectors. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL MODEL IM 1/I. Ethernet Bridge Module. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL MODEL 570-R8/570-R R8/580-R Base-T (CAT-5) Surge Protectors

USER MANUAL. MODEL 1090 High Speed Synchronous Short Range Modem. Dear Valued Customer,

USER MANUAL MODEL CopperLink Ethernet Extender SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL MODEL 1018RC. Powered High Speed Short Range Modem: Rack Mount Card

USER MANUAL MODELS 2156 & CopperLink Ethernet Extenders SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL MODEL 570/ Base-T (CAT-5) Surge Protectors SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL MODEL 1010RC. Miniature Short Range Modem with Transformer Isolation: Rack Mount Card

USER MANUAL. MODEL 1082 and 1082/144 idsl Modem with V.35 or X.21 Interface. An ISO-9001 Certified Company

Instruction Guide. Two Port ISA Serial Card ISA2S550. The Professionals Source For Hard-to-Find Computer Parts

Enclosure TS-530 User Manual

SPL Hub TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...3 SECTION 3 - INSTALLATION...4

USER MANUAL MODEL CopperLINK High Speed Ethernet Extenders

Conitel ASYNC Adapter

Model 282 Total Interface Isolation Module Reference Manual Rev. A Print Table of Contents 1.0 General Description 2.

1206P (CTS ME-X.21) MODEM ELIMINATOR, X.21 INSTALLATION AND OPERATIONS MANUAL. Doc #: UA Part #: 07M1206P-A

XC300 VDSL Network Extender Owners Manual

Enhanced Mini-Chansim Model VCS-232

OPERATOR S MANUAL MODEL DSU-56SA. 56 Kbps Stand Alone CSU/DSU

ASYNC Sharing Unit TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...5 SECTION 3 - INSTALLATION...7

ANC Series RS-422 Serial Communications Adapter

USER MANUAL. Model 2070 Series. V.24/X.21/V.35 to G.703 Interface Converter

USB to RS232 Adapter

F280XD Fiber-Optic RS-232 Modem Technical Manual

ASYNC Sharing Unit TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...5 SECTION 3 - INSTALLATION...7

This revision of the manual is dated June, All modifications from previous versions are listed in the appendix.

Ethernet Extender. EnviroNET 2100 Series. Quick Start Guide

Contents INTRODUCTION...1 CARD SETUP...2 INSTALLATION TECHNICAL DESCRIPTION SPECIFICATIONS... 14

1205P MODEM ELIMINATOR, V.35 INSTALLATION AND OPERATIONS MANUAL. Doc #: UA Part #: 07M1205P-A (CTS ME-V.35)

Instruction Guide. 2 Channel Ultra ATA/100 PCI Card PCI2IDE100. The Professionals Source For Hard-to-Find Computer Parts. Revised: December 5, 2002

F2238A and F2245A Fiber-Optic EIA-530/MIL-STD Modem Technical Manual

RTD Embedded Technologies, Inc.

TS-Modem User s Manual

Dual Serial Shield User Manual

USER MANUAL. MODEL 2500 Series. Models 2500, 2510, 2520 All-Rate CSU/DSU SALES OFFICE (301) TECHNICAL SUPPORT (301)

Xtreme/104. PC/104 Serial Communications. User Manual

PCI Express Serial Adapter

M82xxD Fiber Optic RS-232 MicroModem Technical Manual

SC532A 9-PIN PERIPHERAL TO RS232 INTERFACE INSTRUCTION MANUAL

MEC-COM-M154. User s Manual

It s Under Control. Installation and Operation Guide CPB-1. Control Port Connecting Block V 1.1

SCADA Point-to-Point Multiplexer

SeaLINK+232I USER MANUALM

MEC-COM-M114. User s Manual

WhiteHEAT/USB Multi-port Serial Adapter for USB

Owner s Manual. 2-Port DB9 RS-232 Serial PCI Card

PCI Parallel Card. 1 Port High-Speed EPP/ECP Parallel Card PCI1P PCI1PECP3V. Instruction Manual. Actual product may vary from photo

Instruction Guide. PCI 1-2 Port Serial Card PCI1S550 PCI2S550 PCI2S550_LP. The Professionals Source For Hard-to-Find Computer Parts

RTD Embedded Technologies, Inc.

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch

Professional USB to Serial Adapter Hub with COM Retention

D56 Modem TABLE OF CONTENTS SECTION 1 - DESCRIPTION...4 SECTION 2 - SPECIFICATIONS...6 SECTION 3 - INSTALLATION...7

SeaLINK+8/USB. Sealevel Systems, Inc 155 Technology Place P.O. Box 830 Liberty, SC USA

fiber optic gateway control box

Data Broadcast Switch

COMM+8.LPCI Users Manual Part Number 7803

Installation Guide for Flex Tap

Global Water Instrumentation, Inc.

OPERATIONS MANUAL PCM-DOC

USB 3.0 Spectra

NanoServ. Setup Guide. Thin System/Ultra-Thin System. 1.0 What s included with the NanoServ. 2.0 Steps for setting up the NanoServ

Serial ExpressCard 4 port 16C950 Serial ExpressCard

NT1-220 Rack. Installation Instructions. Specifications. Contents of Shipping Box. Important Safety Instructions. NT1-220 Rack

EXT-DVI-FM1000P User Manual

COMM+16.PCIe User Manual Part Number 7161e

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X

2 Port RS232 PCI Express Serial Card with Power Output

CC186 AND CC186/2 STAND-ALONE OR SYSTEM CLOCK

PCI Serial Card 2 Port RS-422/RS-485 PCI Serial Card with Terminal Block Connectors PCI2S422TB Instruction Manual Actual product may vary from photo

Bluetooth USB Adapter TALUS. User Guide

USB Ranger Fiber Optic USB 2.0 Extender. User Guide

Ground Isolated RS422/RS485 Serial PCI Card DB9

TC1880 Series. 4/5/6/8 Channel RS-232 FIBER OPTIC MICRO MUX User's Manual

Power Rack 58. EXT-PS5-8R User Manual.

USB Port (PCI) Users Guide

Instruction Guide. External 3.5" IEEE-1394b FireWire 800 and USB 2.0 Combination IDE Hard Drive Enclosure IDECASEU2FB

ASKING FOR ASSISTANCE

VCMDM MODEM INSTALLATION INSTRUCTIONS

Reliable High-Performance 350 Watt ATX 12V Power Supply. ATXPOW350PRO Instruction Manual

EXT-HDMI1.3-1FO User Manual

Transcription:

USER MANUAL MODELS 1205 and 1205/34 Synchronous V.35 Modem Eliminators An ISO-9001 Certified Company Part #07M1205-D Doc #049021U, Rev. E Revised 1/22/08 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www.patton.com

1.0 WARRANTY INFORMATION Patton Electronics warrants all Model 1205 components to be free from defects, and will at our option repair or replace the product should it fail within one year from the first date of shipment. This warranty is limited to defects in workmanship or materials, and does not cover customer damage, abuse or unauthorized modification. If this product fails or does not perform as warranted, your sole recourse shall be repair or replacement as described above. Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product. These damages include, but are not limited to, the following: lost profits, lost savings and incidental or consequential damages arising from the use of or inability to use this product. Patton Electronics specifically disclaims all other warranties, expressed or implied, and the installation or use of this product shall be deemed an acceptance of these terms by the user. 1.1 RADIO AND TV INTERFERENCE The Model 1205 generates and uses radio frequency energy, and if not installed and used properly that is, in strict accordance with the manufacturer s instructions may cause interference to radio and television reception. If the Model 1205 does cause interference to radio or television reception, which can be determined by disconnecting the unit, the user is encouraged to try to correct the interference by one or more of the following measures: moving the computing equipment away from the receiver, re-orienting the receiving antenna and/or plugging the receiving equipment into a different AC outlet (such that the computing equipment and receiver are on different branches). 1.2 CE NOTICE The CE symbol on your Patton Electronics equipment indicates that it is in compliance with the Electromagnetic Compatibility (EMC) directive and the Low Voltage Directive (LVD) of the Union European (EU). A Certificate of Compliance is available by contacting Technical Support. 1

1.3 SERVICE All warranty and non-warranty repairs must be returned freight prepaid and insured to Patton Electronics. All returns must have a Return Materials Authorization number on the outside of the shipping container. This number may be obtained from Patton Electronics Technical Support: (301) 975-1007; http://www.patton.com; or, support@patton.com. NOTE: Packages received without an RMA number will not be accepted. Patton Electronics' technical staff is also available to answer any questions that might arise concerning the installation or use of this product. Technical Service hours: 8AM to 5PM EST, Monday through Friday. 2

2.0 GENERAL INFORMATION Thank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected and tested and is warranted for One Year parts and labor. If you have any questions during installation or use of the Model 1205, contact Patton Electronics Technical Support at (301) 975-1007. 2.1 FEATURES V.35 (EIA-530) operation Synchronous data rates from 32 to 144 Kbps Host-to-host distances up to 300 feet Constant or RTS controlled carrier selections RTS-CTS delay options of 0mS, 7mS or 53mS Power derived from V.35 interface Internal or external clocking All necessary data, clocking and control signals supported Made in the U.S.A. 2.2 DESCRIPTION The Patton Model 1205 synchronous modem eliminator lets two synchronous hosts communicate with each other in the same room for a fraction of the cost of a pair of high speed modems. Supporting synchronous data rates of 32, 48, 56, 64, 72, 112, 128 and 144 Kbps, the Model 1205 can be configured to emulate dial-up or leased line service. Maximum distance between the connected hosts is 300 feet. Timing can be set for internal or external clock, and all necessary data, clocking and control signals are supported. The Model 1205 modem eliminator implements the V.35 electrical interface on dual DB-25 or dual M/34 female connectors, according to the EIA-530 Standard. Operating power for the Model 1205 is drawn from the V.35 interfaces, so no AC power or batteries are required. 3

3.0 CONFIGURATION The Model 1205 is equipped with one internal four-position DIP switch and six internal jumpers that allow configuration to a wide range of applications. This section describes all possible configuration settings, including the factory default settings. 3.1 ACCESSING SWITCHES AND JUMPERS All switches and jumpers are located on the Model 1205 PC board. To access the PC board, open the Model 1205 case by inserting a small flat-blade screwdriver in the slot on either side of the case and twisting gently. As Figure 1 (below) illustrates, the DIP switches are located on the daughterboard and the jumpers are located on the main PC board. Switches Jumpers Port A Off On 4 2 3 1 JP2 JP1 Port B JP3 Figure 1. Model 1205 DIP Switch and Jumper Locations on PC Board 3.2 INTERNAL DIP SWITCH The Model 1205 has one four-position DIP switch mounted on the internal daughterboard. Figure 2 (below) shows the numbering of the individual switches and their ON/OFF positions relative to the daughterboard. On 4 3 2 1 Port B Figure 2. Model 1205 DIP Switch Orientation on Internal Daughterboard 4

S1 through S3: Data Rate Setting Switches S1 through S3 are set in combination to determine the synchronous data rate for the Model 1205. Switch S4 is not active. S1 S2 S3 S4 Setting Off Off Off N/A 32 kbps (factory default) On Off Off N/A 48 kbps Off On Off N/A 56 kbps On On Off N/A 64 kbps Off Off On N/A 72 kbps On Off On N/A 112 kbps Off On On N/A 128 kbps On On On N/A 144 kbps 3.3 INTERNAL JUMPERS The Model 1205 has three pairs of jumpers (JP1, JP2 and JP3) mounted on the internal PC board. See Figure 3, below. These jumpers set clocking, carrier, and RTS/CTS delay independently for ports A and B. JP3 JP1 JP2 PORT B PORT A PORT B Figure 3. Model 1205 Jumper Orientation and Factory Default on Internal PC Board. Figure 4 (following page) presents a detailed view of JP1, JP2 and JP3, and also shows the factory default setting for each jumper. Please observe that each pair contains one strap to configure Port A and one strap to configure Port B. Observe also that each strap has three possible positions: covering posts 1 & 2, covering posts 2 & 3, or removed altogether. The detailed description for each pair of jumpers presents all valid strap position options. 5

JP3 JP1 JP2 1 2 3 1 2 3 1 2 3 Port B Port B Port B Port A Port A Port A 1 2 3 1 2 3 1 2 3 Figure 4. Detailed View of Model 1205 Jumpers Showing Factory Default Settings JP1: RTS/CTS Delay The setting for jumper JP1 determines the amount of delay between the time the Model 1205 sees RTS and when it sends CTS. In order to emulate either dial-up or leased line modems, you can set this strap at either 0 msec, 7 msec or 53 msec. Note: Port A and Port B must be configured separately. Jumper functions are identical. JP1 Position 1&2 Position 2&3 Strap Removed JP2: Carrier Control Setting 7 msec Delay (factory default) 53 msec Delay 0 msec Delay The setting for jumper JP2 determines whether the Model 1205 s carrier is constantly on or controlled by RTS. Note: Port A and Port B must be configured separately. Jumper functions are identical. JP2 Position 1&2 Position 2&3 Strap Removed JP3: Clock Source Setting Carrier Controlled by RTS Carrier Constantly ON (factory default) Not a Valid Setting The setting for jumper JP3 determines whether clocking is internal, external or received loopback. Note 1 : Only port A may be set for external clock. Note 2 : If Port B is set for receive loopback clock, Port A must be set for external clock. Port B may not be set for external clock. JP3 (Port A) Position 1 and 2 Position 2 and 3 Strap Removed Setting Internal Clock (factory default) External Clock Not a Valid Setting JP3 (Port B) Position 1 and 2 Position 2 and 3 Setting Internal Clock (factory default) Received Loopback Clock 6

Strap Removed Not a Valid Setting Sync. Host A - may supply clock 150 foot Cable Model 1205 Sync. Host B - may not supply clock 150 foot Cable Port A Port B Figure 5. Maximum Allowable Cable Distances for the Model 1205 7

4.0 INSTALLATION & OPERATION Once the Model 1205 is properly configured, installation and operation are very simple. The Model 1205 draws all necessary operating power from the V.35 interface, thus no AC power or batteries are required. There is no power switch. Just like a cable, the unit should operate transparently when the host devices are turned on and communicating. Follow these installation and operation instructions. 1. Configure the Model 1205 for your specific application according to the instructions in Section 3.0 of this manual. 2. Turn off the host (DTE) devices to which the Model 1205 is to be connected. 3. If one of the host devices has an EIA-530 port, you may plug the Model 1205 directly into that device. Then connect the Model 1205 to the other host device using a multipair cable* not to exceed 300 feet in length. 4. If neither host device has an EIA-530 port, you will need a multipair adapter cable* for each end of the Model 1205. The total cable length must not exceed 300 feet. See Figure 5 above. 5. Turn on both host devices. They should communicate normally as if connected by a simple cable. If they do not communicate properly, check the configuration of the Model 1205 and each host device (Who is supplying the clock?, etc.). If problems are still detected, call Patton Technical Support a: (301) 975-1007; http://www.patton.com; or, support@patton.com. *Custom DB-25 to M/34 adapter cables are available from Patton Electronics at (301) 975-1000; http://www.patton.com; or, support@patton.com. See Appendix B for details. 8

APPENDIX A MODEL 1205 SPECIFICATIONS CCITT V.35/EIA-530 INTERFACE (DB-25 Female) Data Transmit Data B - 14 Receive Data B - 16 Receive Clock A - 17 Data Term. Ready (DTR) - 20 External Clock A - 24 1 - (FG) Frame Ground 2 - Transmit Data A 3 - Receive Data A 4 - (RTS) Request to Send 5 - (CTS) Clear to Send 6 - (DSR) Data Set Ready 7 - (SG) Signal Ground 8 - (CD) Carrier Detect 9 - Receive Clock B 11 - External Clock B 12 - Transmit Clock B Rates: Clocking: 32, 48, 56, 64, 72, 112, 128 and 144 Kbps Internal, external or receive loopback CCITT V.35 Interface (M/34 Female) Signal Ground -B Clear To Send -D Data Carrier Detect -F Receive Data (A) -R Receive Data (B) -T Receive Timing (A) -V Receive Timing (B) - X A- Frame Ground C- Request to Send E- Data Set Ready H- Data Terminal Ready K- M- P- Transmitted Data (A) S- Transmitted Data (B) U- Terminal Timing (A) W- Terminal Timing (B) Y- Transmit Timing (A) AA- Transmit Timing (B) Interface: Distance: ITU/CCITT V.35/EIA RS-530 300 feet (DTE to DTE) Connectors: DB-25 or M/34 female on both Port A and Port B 9

Power Supply: Draws interface power from RTS & DTR signals on both ports. RTS/CTS Delay: Strap selectable, 0, 7, 53 ms (+/- 15%) Altitude: Humidity: Dimensions: 0 to 10,000 feet 5 to 95% noncondensing Approximately 3 x 2 x.75 (76 x 51 x 10

Dear Valued Customer, Thank you for purchasing Patton Electronics products! We do appreciate your business. I trust that you find this user manual helpful. We manufacture one of the widest selections of data communications products in the world including CSU/DSU's, network termination units, powered and self-powered short range modems, fiber optic modems, interface converters, baluns, electronic data switches, data-line surge protectors, multiplexers, transceivers, hubs, print servers and much more. We produce these products at our Gaithersburg, MD, USA, facility, and can custom manufacture products for your unique needs. We would like to hear from you. Please contact us in any of the following ways to tell us how you like this product and how we can meet your product needs today and in the future. Web: http://www.patton.com Sales E-mail: sales@patton.com Support E-mail: support@patton.com Phone - Sales (301) 975-1000 Phone - Support (301) 975-1007 Fax: (301) 869-9293 Mail: Patton Electronics Company 7622 Rickenbacker Drive Gaithersburg, MD 20879 USA We are committed to a quality product at a quality price. Patton Electronics is ISO 9001 certified. We meet and exceed the highest standards in the industry (CE, UL, etc.). It is our business to serve you. If you are not satisfied with any aspect of this product or the service provided from Patton Electronics or its distributors, please let us know. Thank you. Burton A.Patton Vice President P.S. Please tell us where you purchased this product: