Liebert Hipulse E Liebert Hipulse E

Similar documents
Liebert Hipulse E Hi-Availability UPS. Power Quality Solutions. Compact Footprint. Multi Bus Compatible. Wide Input Voltage & frequency Ranges

Liebert NX - Next Generation UPS for protecting your Business Critical Systems. AC Power Systems for Business-Critical Continuity

Hipulse-U UPS 80kVA - 500kVA Utmost Reliable Power Solution for Critical Business Applications

Liebert NX Series. 30kVA to 200kVA. AC Power for Business-Critical Continuity TM

Tel: AC Power for Business-Critical Continuity TM

Liebert NXr Series 15KVA to 90KVA (208V/220V) AC Power for Business-Critical Continuity

Liebert NX Series. 30kVA to 200kVA. AC Power For Business-Critical Continuity

Liebert NXr Series 30kVA to 160kVA. AC Power for Business-Critical Continuity TM

UPS. centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw INFINITE POWER. Mission Critical Applications

Liebert Hipulse-U. Fully Digital Dual DSP Controlled Transformer Based UPS

LEVELUPS T3. SERIES kva ONLINE UPS 3:3 PHASE VFI TYPE. Highest Reliability and Robust Protection for Industrial Loads

10 kva 3/1 15 kva 3/1 20 kva 3/1 10 kva 3/3 15 kva 3/3 20 kva 3/3 30 kva 3/3 40 kva 3/3 UOUS SERV WARRANTY

R E C T I F I E R I N V E R T E R C O N V E R T E R MP7

MP7. Uninterruptible Power Supply

LEVELUPS T3 3 UPS. SERIES kva ONLINE UPS 3:3 PHASE VFI TYPE. Highest Reliability with Embedded Isolation Transformer

Liebert. APM from 30 to 300 kw. The Compact Row Based UPS With FlexPower Technology

APMTM UPS 30kW - 300kW The Compact Row-Based UPS With Flexpower Technology

the Centric 300 An advanced modular UPS up to 1800kVA/kW

APMTM UPS 18kW - 90kW The Flexpower Technology for mission critical applications

PowerWAVE 9250DPA. ( N+1 kva/kw) Parallelable up to 1.5 MVA/MW

TME Modular Series UPS System kva/kw - 208/220 VAC

SmartOnline SVTX Series 3-Phase 380/400/415V 30kVA 27kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

MasterNOVA. MasterNOVA (3/1) MasterNOVA 250i - 600i (3/3) MasterNOVA Pro /3)

Liebert NXC. 10 to 40kVA Compact and Reliable Power in a Fully Integrated Packaged Solution

The Power of Modularity

UPS Sentry MPS. SENTRY MPS is also compatible with different battery technologies: openvase lead acid and AGM and Gel VRLA, NiCd.

Liebert SX TM. 60kVA to 200kVA UPS Three Phase Input, Three Phase Output

Keor HPE UPS THREE-PHASE UPS. from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Galaxy VX. From 500 to 1500 kw N+1 Parallel solutions up to 4000 kw 380V / 400V / 415V / 440V. schneider-electric.com/ups

SMARTONLINE E3 UPS SYSTEMS

ALL PSU Ltd ROTATION+ 6kVA - 10kVA PARALLEL ON LINE DOUBLE CONVERSION

Keor HPE UPS. THREE-PHASE UPS from 60 to 300 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Liebert NXC from 10 to 60kVA

UPS TRIFASE kVA Rev. 8 Serie TPH IGBT

Liebert NX from 30 to 60 kw. AC Power for Business-Critical Continuity

Liebert APM. The Compact, Row-Based UPS with Flexpower Technology 30kW - 300kW

MUST900 Modular UPS. Datacenter & servers. Internet centers. Local Area Networks (LAN) Telecommunication devices. Emergency application

Liebert. EXL UPS 800 and 1200kVA Single Module and Multi-Module Systems

Technical Data Sheets Uninterruptible Power Supply LP11 Series UPS kva

Liebert APM The Compact Row-Based UPS With Flexpower Technology TM 30kW - 300kW. AC Power For Business-Critical Continuity

Liebert. NXC from 10 to 200 kw. Compact and Reliable Power in a Fully Integrated Packaged Solution

MGE Galaxy /50/60/80/100/130 kva. The recommended power protection for all critical applications

Higher Availability: Self-diagnostics. Automatically tests unit electronics and batteries. Designed to simplify maintenance and troubleshooting.

Socomec Netys PR RT U P S TOWER / RACK MOUNT

Modular UPS S KVA

MasterNOVA. MasterNOVA (3/1) MasterNOVA 250i - 600i (3/3) MasterNOVA Pro /3)

Est ComPower Mini. Compact UPS kva

PHASE ONE Series 700: Uninterruptible Power Supply (UPS) Systems

GAMATRONIC, A SolarEdge Division.

Product brochure. Conceptpower DPA Modular UPS DPA 120 UL 208V: 20kW 600kW

Chloride. FP-60z 5 160kVA 1ph / 3ph Industrial AC UPS System

SmartOnline 10kVA On-Line, Double-Conversion UPS, 6U Rack/Tower, 3-Phase input, 1-Phase output

AC Power For Business-Critical Continuity. Liebert NX. UPS For Small And Medium Business

THOR Modular. Modular UPS system. Online double-conversion Scalable Decentralized Parallel. Modular. 10, 20, 30, 40kVA modules kVA systems

SmartOnline V 10kVA 7kW Online, Double-Conversion UPS, 6U Rack/Tower, Extended Run, Pre-installed SNMP port, RS232, 3 Phase in-single Phase out

Liebert APM The Compact Row-Based UPS With Flexpower Technology TM 30kW - 300kW. AC Power For Business-Critical Continuity

PRODUCT BROCHURE. Conceptpower DPA V UL Modular UPS 20kW 600kW

1PH RACK 19 SINGLE PHASE UPS Rev. 11 SR 6kVA 10kVA

Distributed by. Keor T UPS THREE-PHASE UPS. from 10 to 120 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Liebert GXT MT kva

Power Quality Book. Hipulse System Guide UPS FOR THE DIGITAL WORLD. Version 1.0

PRODUCT BROCHURE. Conceptpower DPA V UL Modular UPS 100kW 3MW

LIBRA pro. UPS kva three-phase / single-phase kva three-phase / three-phase. online

MUST 900 UPS. Finally the benefits of Modular ups are for all. 3 Phase Modular. Hot swappable, scalable 30kVA to 900kVA

Chloride CROSS Rack 16 A, 32 A and 63 A

MGE Galaxy /900 kva

Kohler EW 6000TX. Transformer-based. (UPS kVA)

Product Specifications

MGE Galaxy /30/40/60/80/100/120 kva. The recommended power protection for all critical applications.

ZP120N Online UPS. High Power Intensity. Flexibility. High efficiency with low heat dissipation. Smart Energy Solutions

SmartOnline SVX Series 120kVA Modular, Scalable 3-Phase, On-line Double-Conversion 400/230V 50/60Hz UPS System

Liebert GXT3 5kVA-10kVA UPS Compact UPS Systems For High Power Network Rack Applications. AC Power For Business-Critical Continuity

Liebert. EXS from 10 to 20 kw. Optimized and integrated three-phase UPS solution with high efficiency power protection

Liebert APM UPS The Industry s Highest Energy Efficiency In A Row-Based, On-line UPS. AC Power For Business-Critical Continuity

EP Series II UPS 230 V

DPA UPSCALE TM RI kw Technical Specifications

UPS5000-E (25-75 kva) Series

Critical Power from GE. TLE Series UPS. TLE30-40 & TLE kva/kw Scalable three phase 400 Vac

Liebert NXL 1100kVA / 1100kW UPS Maximum UPS Protection for Large Data Centers

ELEKTRA SMALL FOOT PRINT SERIES. Mission Critical & I.T Grade UPS I.T GRADE ONLINE DOUBLE CONVERSION UPS 10KVA ~ 200KVA (3/3)

Galaxy VM. 160/200 kva Parallel capable up to 800 kva. Three-phase power protection. Galaxy VM trusted partner for your business continuity

Intelligent On-Line UPS

SATURN DATACENTER & SERVERS TELECOMMUNICATION DEVICE INDUSTRIAL APPLICATION TRANSPORTS. Smart Energy Solutions

POWER PROBLEMS T H E U N I N T E R R U P T I B L E P O W E R P R O V I D E R

Liebert NXC from 10 to 200 kva

Sirius series. on-line

Liebert NX. UPS For Small And Medium Business. AC Power For Business-Critical Continuity

POWERVAR SECURITY PLUS SERIES DETAILED UPS SPECIFICATION (8kVA 10kVA)

Liebert EXL TM S kw to 1200 kw. Enhanced Design and Improved Efficiency

SmartOnline 277/480V 3-Phase Wye 80kVA Modular 3-Phase UPS System, On-line Double- Conversion UPS for North America

Power Solutions Catalogue

SmartOnline 80kVA Modular 3-Phase UPS System, On-line Double-Conversion International UPS (not expandable to 120kVA)

SmartOnline SVX Series 90kVA 400/230V 50/60Hz Modular Scalable 3-Phase On-Line Double- Conversion Medium-Frame UPS System, 5 Battery Modules

Liebert exm UPS kva/kw Efficient, Flexible Power Optimized for Midsize Applications FLEXIBLE. ECONOMICAL. INTELLIGENT

Est FlexiPower Ultra UPS FPX Ultra kVA

Multi Power x 42 kw up to 1 MW + redundancy 3:3 VFI TYPE. Utmost Availability Ultimate Scalability Unmatching Power Density

SR Plus series. on-line. SR20 Plus SR20T Plus. SR60 Plus LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS. Industrial PLCS

RT4F-110V/25A RECTIFIER

ATV1200A kv kva. Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface Plinth (2) Power cells (9)

ATV1200A kv kva

Transcription:

Power Protection for Business-Critical Continuity Liebert Hipulse E Liebert Hipulse E

Liebert Hipulse E Hi-Availability UPS The increased sophistication of critical & hyper critical applications in today's digital world and the enhanced dependence of your business on such applications have led Emerson Network Power to design Liebert Hipulse E UPS to provide you high availability of quality power. Having extensively captured the customer needs and thoroughly mapped the same through 360 value analysis, Hipulse E has been carefully designed to deliver high value: investment ratio. The proven performance & reliability of Liebert s Hipulse series, combined with customer delight and value added features have made Liebert Hipulse E the obvious choice across the globe. From reliability to availability, from scalability to redundancy, from user-friendliness to maintainability, from parallelibility to connectivity, from investment protection to lower cost of ownership, whichever value you need, Liebert Hipulse E addresses them all efficiently and effectively, better than the best in the industry. Liebert Hipulse E, as one of the prime members of our array of power quality solutions, is providing the 360 value across the globe for almost all the conceivable critical applications, some of which are listed below for your ready references. Liebert Hipulse E (with true on-line double conversion topology) comes in three popular ratings, ranging from 500 to 800 kva (400V, 50/60 Hz). Carefully picked up featureset to address appropriate customer value is one of the prime objectives to achieve high availability-to-price (ATP) ratio. Major Applications of Liebert Hipulse E are: Information Technology - Data Centres - Servers (LAN, WAN, MAN, ERP, e-mail, web and others) - Networking Telecommunication - Mobile (2G, 2.5G, 3G and the likes) - Paging - Fixed (including WiLL) Industrial Automation - Process (including instrumentation) - Motion (digital drives & robotics) Transport Automation - Airport automation and flight booking - Others including railways & road transport automation & ticket booking Banking, Insurance and Financial Services Software Development Houses / Software Technology Parks (STP) Building Automation - Access Control - Security System - Fire Alarm System - Emergency Lighting - Other Critical Applications Medical Diagnostics - Magneto Resonant Imaging (MIR) - CT Scanning - CathLab Satellite - Uplinking - Earth Stations Information Technology Data Center Rooms Telecom Facilities Network Industrial Facilities Medical Diagnostics 2

Top 10 Customer Values addressed by Liebert Hipulse E are: Hi-Availability of Quality Power by way of system redundancy and multi bus configuration using HiSync & HiSwitch Upstream Green Power achieved through low input current THD & high input power factor using different solutions by way of 6-pulse with harmonic filter or 12-pulse with harmonic filter, depending on the requirement Reduced Cost of Ownership by way of improved input power factor (reducing electricity bill) and compact gross footprint (reducing active & passive occupied spaces) Ease & simplicity in Expendibility & Redundancy with the parallelibility up to 6 modules with or without Main Static Switch (MSS) Investment Protection (for upstream semi-critical loads, UPS, battery and downstream critical loads) by way of reasonably wide input voltage & frequency tolerances (minimizing the events of battery discharging), optional temperature-compensated battery charging, back-feed protection, short-circuit-proof inverter. Maintainability by way of built-in maintenance bypass, optional wrap-around maintenance bypass, electrical interlocking system, redundant configuration (allowing you to maintain the redundant modules) and dual bus compatibility (enabling you to transfer the load to alternate bus) Serviceability by means of front accessibility of critical components, event logging with date & time stamping, hours-run indication and wide-angle (>180 ) door-opening Flexibility in decision making though innumerable choices to pick from (e.g. type of battery, number of configurations, myriad combinations of 6 or 12-pulse with or without filter and array of internal & external power & communication options) User flexibility (choices of 5-language LCD, adjustable power walk-in, making myriad user-specified settings, having data through innumerable power communications alternatives etc.) and user friendliness (menu-driven LCD with detailed data reporting) Power Communications with the use of Relay Card, SNMP Web Card, ModBus / Jbus Card, MultiLink Software etc. Each one is designed to address the specific needs of each business function. For example, SNMP Web Card will be useful for your Network Manager, while the ModBus / Jbus Card will be more desirable to your Facility Manager. Having understood & captured the customer needs across the world, the prime focus of the European Product Development Team of Liebert was to achieve a high level of value innovations to provide considerable value to you. Hipulse-E is a solution of that Europen initiative of Liebert, which offers you the best-in-class value. 3

Value-Added Features Having thoroughly understood & captured the present, latest & anticipated customer needs across the world, the Product Management Team of Liebert Hiross has come out with the follo wing value-added features for your hyper critical applications. Utility-Friendly & Generator-Friendly Liebert Hipulse E with its 12-pulse rectifier version, considering in-built optional harmonic filter, is extremely utility-friendly. In this configuration, Hipulse E achieves <4-5% input current THD (Total Harmonic Distortion) and >= 0.90 input power factor (PF). The former one (the THD) ensures almost clean power in the upstream avoiding pollution and thus damage to the other semi-critical loads connected to the upstream power distribution bus. Moreover, it also ensures lower investments in cable costs (due to reduced cable size). The later one (the PF) helps you maximising active power leading to saving in cost of ownership (in terms of lesser electricity bill) and also ensures reduced investment towards motor generator set (by way of minimising its sizing), making it generator-friendly. Overall, Hipulse-E is an Utility-Friendly & Generator-Friendly system employing this appropriate solution. Horizontal Xpandability & Redundancy Liebert Hipulse E is designed to parallel up to as high as six (6) UPS modules to achieve either capacity or redundancy. The system can grow (through horizontal xpandability) as your business grows or the system can provide you higher availability, as your business demands it. Achieving parallelibility up to six modules can be achieved with or without the centralized static switch & centralized controller. Thanks to Liebert s unmatched paralleling technique to provide you with both the alternatives aptly needed for large power UPS configurations. Multi Bus Compatibility Liebert Hipulse E has the feature of achieving multi bus configurations by the use of optional HiSync (to ensure synchronisation among the multi bus systems) and optional HiSwitch or Liebert HiSwitch2 (the static transfer switches). This configuration will allow you to automatically transfer power (from one bus to the other, whenever the need arises). This gives you significant values to ensure high availability (Hi 9 s) of quality power. We have successfully executed m ultiple projects of 2-bus, 3-bus & 4-bus systems with HiSynch & HiSwitch. This is what made Hipulse the best-in -class High Availability UPS system. Liebert Hipulse E is an enhanced version of that Hipulse. Flexi Power Walk-In Liebert Hipulse E is designed to have flexible power walk-in (another unique feature) by way of adjusting the power walk-in from 5 seconds to 120 seconds. This gives you the opportunity to have optimized motor generator sizing (leading to reduced investment for you) and the user flexibility to have different walk-in time period for different paralleled UPS modules (offering user fle xibility). Temperature Compensated Battery Charging Liebert Hipulse E allows the user to use optional temperature monitoring kit (to be connected to the battery bank) to monitor the temperature of the battery and thereby controlling the battery charging voltage. This helps you to protect the battery investment by way of protecting the battery health. Compact Active & Passive Footprints Liebert Hipulse E is designed to minimize both the active & passive footprints. As you know, the active footprint is the physi cal, visible & actual floor space occupied by the cabinet. The passive one is invisible-but-implied space needed for the thermal management &/or accessing critical components like PCB s (Printed Circuit Boards), Capacitors, Fans etc. Hipulse E employs simple thermal management and front-access layouting objective. The cool air is drawn from the front and the hot air is expelled out from the top. This is how Hipulse E offers you a compact gross footprint, reducing your cost of ownership to the lowest possible level. Hipulse E can house anyone of the following remote power c ommunication aids by means of the following optional hardware: Configurable Relay Card (to address the basic need of a user/maintenance persons) Open Comms Web Card (to address the needs of a network manager) ModBus / Jbus Card (to address the needs of a facility manager) 4

Other Remote Communications Liebert Hipulse E also provides other communications alternatives through RS-232 & RS-485 ports and through HiroLink, IGMNet protocols. These provide you with the opportunity to integrate the communication system with our High Performance Air Conditioning (HPAC) systems. Other than utilizing RS-232 port for remote communication, it can also be used for local downloading of data for the service engineers, while the RS-485 port can be utilized to have remote communications of myriad applications. Local Communications Liebert Hipulse E provides excellent local communications by way of its Man-Machine Interface (MMI). The MMI of Hipulse E uses some important push buttons (including Emergency Power Off :EPO with a transparent cover), LED-based MIMIC diagram and a LCD. While the MIMIC shows you the live power path, the back-lit LCD provides you with the requisite parameters of the unit in six (6) different languages (can be chosen from 8 different languages at the ordering stage) through user-friend ly menu including event history with date & time stampings. Customer Values are Mapped to Major Features of Liebert Hipulse E for ready References Feature-Need Value Matrix Protection System Communication Need Categories Financial Application & Business Features Customer Reduced Investment Lower Cost of Ownership Investment Protection Reliability Hi Availability of Q Power Scalability Redundancy Maintainability Back-Feed Protection Dc Ground Fault Detection (option) Short Circuit protected inverter 6-IGBT based PWM Invert High Overload Handling Capability Hot Standby Configuration Parallelable up 6 (six) UPS Units without MSS Parallelable up 6 (six) UPS Units Dual Bus Compatibility Event History on LCD 8-Language LCD (5: Standards, 3 optional) Remote Alarm Monitor (RAM) OpenComms Web Card ModBus/Jbus / JBus Card Programmmable Relay Card Hirolink Application & Business Safety Input Quality Power Output Quality Power User Friendliness User Flexibility Power Communication Compactness Serviceability Intangible & Latent Decision Making Flexibility Customer Confidence Simplicity & Aesthetics 5

Customer Values are Mapped to Major Features of Liebert Hipulse E for Ready references Feature-Need Matrix Input DC Circuit & Battery Static Bypass Need Categories Financial Application & Business Operational Intangible & Latent Features Customer Reduced Investment Lower Cost of Ownership Investment Protection Reliability Hi Availability of Q Power Scalability Redundancy Maintainability Safety Input Quality Power Output Quality Power User Friendliness User Flexibility Power Communication Compactness Serviceability Decision Making Flexibility Customer Confidence Simplicity & Aesthetics Input Current THDi <5% (optional with 12 p+filter) Input Power Factor >= 0.98 (optional with 12 p+filter) Input Voltage Range (323-477 V) Input Frequency Range (47-63 Hz) Input Frequency: 50 or 60 Hz Adjustable Power Walk-In DC Ripple Voltage <1% Battery Test Long Battery Discharge at Low Load Battery Temperature Compensated Charging Flexibility to use VRLA or Wet or NiCd Battery Overloading Condition of 1000% for 10 msecs Frequency Adjustment Range Auto Retransfering Facility Feature-Need Matrix Output Unit Special Feature Appl. Need Categories Financial Application & Business Application & Business Intangible & Latent Features Customer Reduced Investment Lower Cost of Ownership Investment Protection Reliability Hi Availability of Q Power Scalability Redundancy Maintainability Safety Input Quality Power Output Quality Power User Friendliness User Flexibility Power Communication Compactness Serviceability Decision Making Flexibility Customer Confidence Simplicity & Aesthetics Output Voltage THDi <1% Out Power Factor 0,7 (lag) to Unity Output Voltage Regulation <1% Output Frequency Regulation <1% Output Frequency: 50 or 60 Hz Small Gross Footprint Door-Opening >180 degree Top Venting (out) Fans Front Acess IP-20 With Door-Opened Condition Modern Styling Castle Key Interlock Option Input Galvanic Isolation Option Top Cable Entry Option 6

Liebert Hipulse An Outstanding Performer The system's advanced true-online, double conversion topology features a Micro-processor based controlled, 12 Pulse SCR based Rectifier and IGBT Inverter. 12 Pulse Rectifier The rectifier provides up to 0.99 Input Power Factor (PF), up to 3% of Input Current Total Harmonic Distortion (THDi) with Optional configurations of Harmonic filters and the widest input voltage window and frequency tolerances. PWM Based IGBT Inverter Advanced inverter control technology provides the highest output power quality, ensuring very low output voltage THD and superior waveform to protect connected loads. It operates under a wide variety of conditions, handling 100% non-linear loads with 3:1 crest factor, as well as 100% unbalanced loading. The inverter control enables Hipulse to be suitable for the widest ranges of loads required by the market; delivering full active power rated kw up to 0.9 leading PF loads. Value-added Power Options Liebert Hipulse E offer you an array of value-added power options listed below: External Battery Circuit Breaker (wall of cabinet mounted) Battery Cabinet Main Static Switch (MSS) for Centralised Static Bypass Switch Wrap-Around Maintenance Bypass Cabinet Top Cable Entry Input Isolation Transfer Internal Paralleling Kit (for 1+5 modules) Input Harmonic Filter Common Battery Sharing Kit Fan Failure Alarm Power Communication Option IP Protection: IP21 - IP30 - IP31 Remote Alarm Monitor (wall mounted) Special Feature Applications (SFA s)* Dynamic System Espander (DSE) Multi-Bus (2-bus, 3-bus and 4-bus) 7

The Best Investment You can make in a UPS System : Reliability, Efficiency and value in a compact package How can I get the highest levels of Protection and Availability? The Liebert Hipulse gives you built-in reliability with power supply cards, highly efficient stratified cooling of critical components and cooling fans. Wider input voltage and frequency tolerances contribute to high power availability. Dual bus compatibility and system redundancy further enhance the availability of power. High overload protection handles 110% overload for 60 minutes, 125% for 10 minutes, and 150% for 1 minute. How can I save on my electricity bill and investment costs? The improvement in input power factor of the Liebert Hipulse can actually reduce your electricity usage. The unique ability of the Hipulse to adjust power walk-in from 2 seconds to 10 seconds selectable, along with reduced input current distortion and power factor correction, also enables you to save money by reducing backup generator sizing requirement. The unit's with transformer compact footprint requires less floor space, leaving you with more room for other equipment. Hipulse has features to Parallel up to six UPS an modules in redundant configuration for added reliability and serviceability, also it is compatible with Load Bus Synchronization (LBS). How can I satisfy the requirements of the latest generation servers? Liebert Hipulse is capable of driving wide ranges of loads, from 0.8 lagging to 0.9 leading without kw de-rating, this feature makes the UPS able to follow the latest IT industry trends, with more active power available for all kind of loads. How can I protect also my upstreamconnected devices? The Liebert Hipulse provides the clean best level of upstream power with the lowest level of input current THDi in the industry with additional filters. This ensures that clean power flows upstream, avoiding damage to other loads connected to the upstream power distribution bus. How can I protect and extend the life of my batteries? Liebert Hipulse minimizes transfers to batteries thanks to its wide input voltage tolerance. Temperature-compensated battery charging extends battery life. How can I ensure the UPS will work under the most severe conditions? The wide input voltage window of +10/- 15% and a frequency tolerance of +/-5% provide high quality power, even when input parameters are below standard. This helps to minimize transfer to battery, reducing the charging and discharging cycles. Back-feed protection sensing ensures system integrity. Short-circuit-proof, IGBT Inverter provides highest output power quality. How can I easily maintain my UPS? Liebert Hipulse includes a built-in maintenance bypass, optional wraparound maintenance bypass with IP 20 UPS enclosure protection -even with the front doors open. Redundant configuration allows you to utilize one module while the other is being serviced. Dual bus compatibility enables you to transfer the load to an alternate power source for maintenance activities. 8 How can I monitor and communicate with my UPS? To meet a variety of needs, the Hipulse can provide power simultaneous communications through a Relay Contact Card, OpenComms Web Card and MODbus J-Bus Card and MultiLink shutdown software. How can I check my UPS status? The Hipulse features easy access for service thanks to front accessibility of critical components, self-diagnostics and various monitoring options. Large and user-friendly LCD display provides operating information on front panel of UPS Module. How can I satisfy my particular installation needs? Flexibility is achieved through many choices including type of battery, number of single and multi-unit configurations, and an array of internal and external power and communication options. Auto restart capability provides added availability. Ultra-quiet performance with noise levels below 75dB allows greater altitude in where to place the unit. Adjustable power walk-in, numerous userspecified settings, a choice of power monitoring communications alternatives and user friendly control are all handled through the menu-driven LCD control panel with detailed data reporting. Emerson Network Power is recognized to be a great solution provider. Please contact your local Emerson Network Power India office or Liebert representative to receive special solution consultancy.

Hipulse can be scaled up to as high as 6 modules using any of the following configurations to achieve either scalability or redundancy of desired percentage - 1+N configuration without any kind of centralised static switch - Some more configurations are explained further in this brochure - For other configurations, please contact our nearest sales office / representative 1+N Configuration with Distributed bypass System - Up to six modules in parallel - Increase the system reliability - Increase the availability of quality power following the load demand even if it was not forecasted or planned at the beginning of the project: e a s e o f techno economic Expandability - Increase the maintainability - The total load is less than or equal to the rating of the single UPS (depending on the desired redundancy level) and is shared between all modules Hot Stand-by Configuration - Feed one (Priority) or two (Priority and Normal) load banks depending on the application need - Increase the reliability of the priority load - Increase the maintainability - Easy connection - Can be implemented in the existing - Installation regardless of the UPS size, the generation of (device or technology or philosophy of control) and the manufacturer 9

Dual Bus System with Liebert LTS, STS2 or Hiswitch2 - Provide supply to the loads from two independent power sources - The two may be different in terms of power rating and redundancy - The two BUS outputs are in synchronism between them - Automatic transfer of the load between the two sources in case of fault using Liebert LTS - Increase dramatically the maintainability and reliability Multimodule Configuration WITH Centralised Bypass Called Main Static Switch (MSS) - Up to six Modules in parallel - Increase the system reliability - Increase the power availability up to the MSS Capacity - Increase the maintainability - The Total load is less than or equal to the rating of the single UPS (depending on the desired redundancy level). The load is shared between all modules. 10

General Features Nominal Power Rating at 0.9 PF Load kva 500 600 800 Input Parameters Input Voltage to Rectifier Vac 380/400/415* (400V: nominal) 3-phase, 3-wire Input Voltage to Rectifier Vac 380/400/415* (400V: nominal) 3-phase +N, 4-wire Permissible Input voltage Range Vac 323 to 457 Input Frequency Hz 50 or 60 Permissible Input Frequency Range Hz 47 or 63 @ Input THDi at nominal voltage at full load % <3% with 12-pulse + Filter Input Power Factor at nominal voltage >=0.99% with 12-pulse + Filter Flexi Power Walk-In Second 5 to 120 (selectable) Battery & DC Parameters Battery Type VRLA (Valve Regulated lead Acid) or Wet or Ni-Cd Nominal Battery Bus Vdc 480 396 480 (Float Voltage: 540V) (Float Voltage: 446V) (Float Voltage: 540V) End-Cell Voltage Vdc/Cell Selection from 1.65 to 1.90 (for VRLA/Wet Cells) DC ripple voltage in float & Const V Ch. mode % <1 (RMS value) Temperature compensated Battery Charging Output Parameters Inverter Type Optional IGBT-based Sine-Sine PWM Controlled Output Power KW 450 540 720 Output Voltage Vac 380/400/415* (400V: nominal) 3-phase, 4-w Output Voltage Regulation % +/- 0.5 (3 phase RMS average) Output Frequency Hz 50 or 60 Output Frequency Regulation % +/- 0.05 Output Voltage THD at nominal voltage % 1 (typ), 2% (max) Capacity to handle High Crest Factor Load 3:1 (compliant with IEC 62040-3) Capacity to handle Step Load % 0-100 or 100-0 Transient Recovery M seconds 10 (recovery to 95% of the voltage level) Capability to handle Leading PF Load Up to 0.7** Voltage Displacement el 120 +/- 1 el (with 100% unbalanced load) Overload Conditions %FL 110 for 60 minutes / 125 for 10 minutes / 150 for 1 minutes System Parameters UPS Efficiency (without any power option) % Up to 93.5 (depends on rating & operating condition) Physical Parameters & Standards Width (applicable to 12 pulse version)*** mm 2460 3200 4410 Depth mm 1000 Height mm 1900 Weight 12p (approx.) kg 4200 4500 5050 Color RAL 7035 Front door Opening (for better Serviceability) More than 180 Degree of Protection for UPS Enclosure IP 20 even with front door in opened condition Standards & Conformities IEC 62040-3, IEC 62040-2, IEC 62040-1-1, CE Mark: EN 62040-1-1, EN 50091-2, EN 62040-3, EN 60950, EN 60529 and VFI 111 Environmental Parameters Storage Temperature C -25 to 70 (UPS) & -20 to 30 (Battery) Operating Temperature Range C 0 to 40 (UPS) & 20 +/-5 (Battery) Relative Humidity % 0 to 95 (non condensing) Maximum Altitude above MSL (Mean Sea Level) m 1000 (as per IEC 62040/3) @ * 4-5% more power output for 415V input & output; ** with suitable derating; ***with OR without input harmonic filter @ Combination of Active + Passive Filters While specifying the parameters here, it is assumed that, extremes of all the conditions do not apply simultaneously. 2004 Liebert Corporation. All rights reserved throughout the world. Specifications subject to change without notice. All names referred to are trademarks or registered trademarks of their respective owners. 11

Country Office Emerson Network Power (India) Private Ltd. Plot No. C-20, Road No. 19, Wagle Estate, Thane (W), Maharashtra - 400 604. India. Tel.: 91-22-33154400 Fax: 91-22-25828358 Toll Free No 18002096070 Email: marketing.india@emerson.com Voice of Customers UPS Awards 2004-05 for Product Line & Customer Service Awards in IT, Telecom, Large Enterprise & Hospitals and Customer Service Leadership Award in BFSI 2007 R Best IT Hardware Company Maharashtra IT Award 2006-07 www.emersonnetworkpower.co.in Emerson Network Power. TM The global leader in enabling Business-Critical Continuity. AC Power Connectivity DC Power Embedded Computing Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection While every precaution has been taken to ensure accuracy and completeness in this brochure, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. For disposal of Batteries Please visit the below link: http://www.cpcb.nic.in/divisionsofheadoffice/hwmd/lead.pdf Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. 2010 Emerson Electric Co.