Power System Simulator The Ultimate Tool for Protection Scheme Testing. The F6150SV Features:

Similar documents
DRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 33. The new generation of advanced three phase relay test set

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 66 can test all the following relays

Bus Bar Protection Relay B-PRO 4000

Environmental. Electrical Specifications at 25 O C E Output Constant Current

Environmental. Electrical Specifications at 25 O C E Output Constant Current

DRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters.

Type MVTT 14 and MVTT 15: Static Digital Time delay relays

We put the now in knowledge Today s solutions built on a century of innovation and expertise

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

THE NEW GENERATION OF ADVANCED TEST EQUIPMENTS FOR RELAYS, ENERGY METERS, TRANSDUCERS AND POWER QUALITY METERS.

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

Scout-S Station Controller

MINER-S Station Controller

SAM Listed LED Optimized Drivers. Environmental. Electrical Specifications at 25 O C E Output Current. Voltage Accuracy

SAM Listed LED Optimized Drivers. Environmental. Electrical Specifications at 25 O C E Output Current. Voltage Accuracy

SAM Listed LED Optimized Drivers. Environmental. Electrical Specifications at 25 O C E Output Current. Voltage Accuracy

RT4B-110V/12A RECTIFIER

CompactBlock Guard I/O EtherNet/IP Safety Modules

Safety Standards. Model Number:

EXPERIENCE. KNOWLEDGE. INSIGHT.

CompuScope Ultra-fast waveform digitizer card for PCI bus. APPLICATIONS. We offer the widest range of

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

Safety Standards. Model Number:

Installation Instructions

RT4F-110V/25A RECTIFIER

Safety Standards. Model Number: Unit Weight:

EM133 EM133 TOU SMART ENERGY METER. Main Features. Multifunctional 3-Phase Smart Meter. Billing/TOU Energy Meter

RuggedMC RMC RUGGEDCOM ISO 9001 REGISTERED. Features and Benefits. Ethernet Media Converter (Copper to Fiber) Universal Power Supply Options

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

Voltage Transducer UMT516 / MT516

100BPS15 B. MDS Medical AC-DC Open Frame 15Volt, 100Watt / MDS-100BPS15 B ``` Highlights & Features. Safety Standards.

Safety Standards. Model Number:

RT4F-48V/50A-WAC RECTIFIER

DRTS 3 PLUS Advanced Protection Relay Test Set and Measurement System

RT12-240V/2.4kW Rectifier Specification

Safety Standards. Model Number:

040APS12 B MDS. MDS Medical AC-DC Open Frame 12Volt, 40Watt / MDS-040APS12 B ``` Highlights & Features. Safety Standards.

Safety Standards. Model Number:

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Specifications and Part Numbers

RT4F-120V/20A-WAC RECTIFIER

Transformer Protection Relay

extending the boundaries of technology evolution of proven technology FEATURES

Safety Standards. Model Number:

Type VRLTC tap changer

RuggedMC RMC40 RUGGEDCOM ISO 9001 REGISTERED. Features and Benefits. 4-Port Ethernet Media and Speed Converter

Multilin EPM Energy and Demand Submeter with Wi-Fi. Monitoring & Metering. Communications. Key Benefits. Applications

DRTS 3 PLUS. Advanced Protection Relay Test Set and Measurement System. DRTS 3 PLUS has been designed to test:

Electronic Submeter with Advanced WiFi Ethernet Capability

Safety Standards. Model Number:

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1A

1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications...

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1AZ

Safety Standards. Model Number:

TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS24 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H):

Chrome DIN Rail Power Supply 12V 9.96W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1A

Environmental. Electrical Specifications at 25 O C. Programmable Maximum Value. Factory Default

INGEPAC DA-CU. Control Unit. Data Sheet ZY8932IMA01E 31/03/2016

EM-1000 /EM-2000/ EM-3000 Series Multifunction Power and Energy Meters

Published by and copyright 2015 Siemens AG Energy Management Freyeslebenstr Erlangen, Germany

Safety Standards. Model Number:

ArmorPoint I/O Field Potential Distributor, Series A

RT7-48V/6kW Specification

microblox I/O Modules w/ Bluetooth Wireless Technology Introduction to the microblox Module Family

Allen-Bradley 1786-RPFRXL

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

Safety Standards. Model Number:

Isolated Voltage Input 3B30 / 3B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Features. Applications and Benefits TRC ELECTRONICS, INC

Constant Voltage Mode

TU531, TU532 Terminal Unit

ENGINEERING SPECIFICATION SHEET SPEC. Revision History

060AAS19 B MDS. MDS Medical AC-DC Adapter 19Volt, 60Watt / MDS-060AAS19 B. Highlights & Features. Safety Standards. Model Number: General Description

Embedded I/O Expansion Board with 10 Outputs

VCL-TP, Teleprotection Equipment With Trip Counter Display Panel

AI531 Analog Input Module

Wide Bandwidth Strain Gage Input 3B18 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

ControlNet-to-DeviceNet Linking Device

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

350A Series MDS 350 A D 701 A A. Technical Datasheet Medical ATX Power Supply ATX 12V 1U Power Supply

EH-RIO IP67 Profibus-DP I/O modules

Providing the missing piece in your Condition Based Monitoring platform

Artisan Scientific is You~ Source for: Quality New and Certified-Used/Pre:-awned ECJuiflment

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

48V 2KW 1U AC-DC Power Supply PS Electrical Specification for: Telkoor Model:

Chrome DIN Rail Power Supply 24V 60W 1 Phase (Class II & NEC Class 2) / DRC-24V60W1A

General information. Display. Supply voltage

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

AX522 Analog Input/Output Module

Relion 611 series. 611 series Type Test Certificate

RT9-48V/1.4kW Rectifier Specification

Isolated Process Current Input 7B32 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Field Configurable Analog Input 6B11 / 6B11HV FEATURES APPLICATIONS PRODUCT OVERVIEW

Isolated Process Current Input with Loop Power 7B35

BFM-II BFM-II BRANCH FEEDER MONITOR. Highlights

CliQ DIN Rail Power Supply 24V 60W 1 Phase / DRP024V060W1AZ

Transcription:

F6150SV Power System Simulator The Ultimate Tool for Protection Scheme Testing The F6150SV is your versatile, all-in-one solution for testing protection relays and schemes. Designed to meet your needs, the F6150SV is capable of performing the most simple through the most complex tests. Whether you need to test an individual component or test an entire scheme, the F6150SV is the proven solution to assess protection system performance for analog testing of 1A and 5A protection devices. Now with increased output power of amplifiers, the F6150SV offers IEC61850 testing, as well as Sample Value Process Bus and Station bus applications in one test set. The F6150SV Features: IEC61850 testing with 3 packets of 9-2 LE communication protocol and station bus messaging - one fiber and one copper IEC61850 communication port Wi-Fi Capable Standard relay calibration and verification testing of High Burden and Microprocessor relays Increased amplifier power output and ranges (enhanced ratings) Protection scheme testing using State Simulation and Transient testing: powerful models made available in Protection Suite Software Metering at 0.2 class CTs and Transducers End to End testing of Communication Based Schemes with GPS time syncing 12 Source, (6-Voltage, 6 Current), configurable for Bench testing and proof of concept testing for complicated relaying schemes

Benefits of the F6150SV Evaluate your protection relays and schemes in their environment, using simulated power system conditions and events. No other single-box solution can equal the test capabilities of the F6150SV. Exceptional test flexibility Six independently controlled direct coupled sources, each rated at 175 VA, provide more than 100 userselectable test configurations to match any test requirement. Each continuous current source can be configured as two independent 87.5 VA sources for a total of 6 current sources. Field-rugged design Rugged construction and proven state-of-the-art design provide laboratory accuracy with uncompromised field performance. Convenient panel display Front panel display indicates active voltage/current amplitudes and phase values during testing. Easy to use PC interface (Ethernet or USB communications) and software for steady state, dynamic state and transient testing. All sources can be controlled from a PC for easy configuration for each test. Includes fiber optic and copper IEC61850 communication ports. Accurate meter testing High-precision measurements for energy meter and transducer testing. F6150SV Enchanced Ratings Enhanced Ranges AC Enhanced Ranges DC Enhanced Power 6 X 8.75, 17.5 A rms (L-N) 6 X 5.83, 11.6 A dc 6 X 87.5VA / 87.5 W 3 X 8.75, 17.5, 35 A rms (L-N) 3 X 5.83, 11.6, 23.3 A dc 3 X 175VA / 175 W 1 X 17.5, 26.25, 35, 52.5, 70, 105 A rms (L-N), S1 S2 S3 1 X 5.83, 11.6, 35,70 A dc S1 S2 S3 1 X 525VA / 525 W Enhanced Transient Ranges AC* Enhanced Transient Ranges DC* Enhanced Transient Power* 6 X 8.75, 17.5, 35 A rms (L-N) 6 X 5.83, 11.6 A dc 6 X 131.25VA / 131.25 W 3 X 8.75, 17.5, 35, 70 A rms (L-N) 3 X 5.83, 11.6, 23.3 A dc 3 X 262.5VA / 262.5 W 1 X 17.5, 26.25, 35, 52.5, 70, 105, 210 A rms (L-N), S1 S2 S3 1 X 11.6, 22.3, 35, 46.7, 70, 140 A dc S1 S2 S3 * Times of longer than 1.5 sec are possible; cooldown time applied by software 1 X 787.5VA / 787.5 W

Protection Suite Solutions Protection Suite and F6Test are robust software programs for reliable, computer-based protection testing that is PRC-005 compliant. Protection Suite and Protection Web Protection Suite and Protection Web work together to form a file based management system for the field testing and administrative control of all relay testing. F6Test - Visual Testing Software Protection Suite F6Test is a highly-automated and graphical testing solution for all protection testing. Complex multi-zone distance relays and differential characteristics are easy to test with a point-and-click interface. The test modules are based on state simulation providing a realistic dynamic test. Other functions like power swings are tested graphically with automatic generation of transient oscillation and fault conditions with the WaveSim module. A versatile state simulation module allows testing of advanced protection schemes. Protection Suite is a technician s control system to test and check complicated relaying schemes. PRC-005 compliant testing can be performed and all records kept electronically and stored via Protection Web on your company s server for ease of NERC reporting and auditing. Protection Web Protection Web is a server based application that collects and manages test results and reporting features tailored to NERC auditing and compliance. It is also used to assign administrative users and privilege settings. Host on your company's network or on a Doble server. Spotlight: Transducer and Meter Control Panel This graphical interface enables test engineers to quickly perform simple performance verification tests on Class 0.2 metering and transducers. It allows users to develop a library of automated tests based on their specific practices and test results. Spotlight on IEC61850 Testing with F6Test and the F6150SV F6TesT supports the F6150SV power system simulator for testing IEC61850-based systems using process bus sampled values (per IEC61850 9-2 LE guidelines) and generic substation events (GSE) messages. F6Test offers easy configuration of sampled value streams with up to 24 currents and voltages. It also allows testing in mixed mode using a combination of conventional voltages and currents as well as sampled values.

Doble provides several options for expanding your F6150SV so you can configure it to exactly fit your needs. These options include: F6910 Simulator Control and Automation Module F6800 Transducer Interface F6810 High Power Convertible Voltage/ Current Sources F6300 High Current Source Customize your Protection Testing F6860 Support for IEC61850 GSE F6885 Global Positioning System (GPS) Receiver Interface F6895 Global Positioning System Receiver and Antenna F6820 AIM Option Expert Help When You Need It With a Doble Services Agreement you have access to valuable resources and tools to enhance your protection and control testing. Services agreements include: Test plan consulting from Doble s application engineers Product support Annual on-site training customized for your team Doble Client Committee membership Client Conference invitation Software upgrades Doble Portal access and more fserieshelp@doble.com for answers from Doble's Protection experts Together we power the World Doble Engineering Company Worldwide Headquarters 85 Walnut Street Watertown, MA 02472 USA tel +1 617 926 4900 fax +1 617 926 0528 www.doble.com Doble Knowledge is Power Doble customers using Doble's protection test software are invited to participate in the International Protection Testing Users Group (PTUG), which is a venue for relay protection engineers and technicians to exchange ideas and new techniques for testing relays. PTUG meetings are held throughout the world. Service Agreement clients are encouraged to participate in Doble s Client Committees, including the committee on Protection, Automation Controls and Communications (PACC). Client Committees review topics of greatest interest and concern, share service advisories, best practices and lessons learned. Participation is limited to representatives from utility, industrial or testing companies to facilitate open discussion without the presence of manufacturers. Committees meet twice a year at the International Conference of Doble Clients and the Client Committee Meetings. Join the conversation. Doble is ISO Certified Doble is an ESCO Technologies Company MKT-SL-F6150SV-03/12

CONVERTIBLE AMPLIFIERS Current Mode Convertible Source AC Ranges Convertible Source DC Ranges Power Resolution AC Ranges Resolution DC Ranges 6 X 0.5, 1.0 A rms (L-N) 6 X 0.354, 0.707 A dc 6 X 75VA / 75 W 0.0001 A 0.0001 A 3 X 0.5, 1.0, 2.0 A rms (L-N) 3 X.354, 0.707, 1.41 A dc 3 X 150VA / 150 W 0.0001 A 0.0001 A 1 X 1.5, 3.0, 6.0 A rms (L-N) 1 X 1.06, 2.12, 4.24 A dc 1 X 450VA / 450 W 0.001 A 0.001 A Current Transient Mode Convertible Source AC Ranges Convertible Source DC Ranges Power Resolution AC Ranges Resolution DC Ranges 6 X 0.75, 1.5 A rms (L-N) 6 X 0.53, 1.06 A dc 6 X 97.5VA / 97.5 W 0.0001 A 0.0001 A 3 X 0.75, 1.5, 3.0 A rms (L-N) 3 X 0.53, 1.06, 2.12 A dc 3 X 195VA / 195 W 0.0001 A 1 X 2.25, 4.5, 9.0 A rms (L-N) 1 X 1.59, 3.18, 6.36 A dc 1 X 585VA / 585 W (0.0001 A) @ 0.53, 1.06 A dc (0.001 A) @ 2.12 A dc 0.001 A 0.001 A Voltage Mode Convertible Source AC Ranges Convertible Source DC Ranges Power Resolution AC Ranges Resolution DC Ranges 6 X 75, 150V rms (L-N) 6 X 106, 212V dc 6 X 75VA/ 75W 0.01 V 3 X 75, 150, 300V rms (L-N) 3 X 106, 212, 424V dc 3 X 150VA / 150 W 0.01 V 1 X 150, 300, 600V rms (L-L) S1 & S2 1 X212, 424, 848V dc S1 & S2 1 X 300VA / 300 W S1 & S2 (0.01 V) @ 106V dc (0.1 V) @ 212V dc (0.01 V) @ 106V dc (0.1 V) @ 212, 424V dc 0.01 V 0.1 V dc ENHANCED CURRENT AMPLIFIERS AC Ranges DC Ranges Power Resolution AC Ranges Resolution DC Ranges 6 X 8.75, 17.5, (35)* A RMS (L-N) 6 X 5.83, 11.7, (23.3)* A dc 6X 87.5VA / 87.5 W; (6 X 131.25VA /131.25 W)* 0.001 A (0.001) A @ 5.83 A dc (0.01) A @ 11.6, (23.3)* A dc 3 X 8.75, 17.5, 35,(70)* A RMS (L-N) 3 X 5.83, 11.7, 23.3,(46.6)* A dc 3 X 175VA / 175 W; (3 X 262.5VA /262.5 W)* (0.001) A @ 8.75, 17.5, 35 A RMS (0.01) @ (70)* A RMS (0.001) A @ 5.83 A dc (0.01) A @ 11.7, 23.3, (46.6)* A dc 1 X 8.75, 17.5, 26.25,52.5, 105, (210)* A RMS (L-N) 1 X 5.83, 11.7, 17.5, 35,70, (140)* A dc 1 X 525VA / 525 W; (1X787.5VA/787.5 W)* (0.001) A @ 8.75, 17.5, 26.25 A RMS (0.01) A @ 52.5, 105, (210)* A RMS (0.001) A @ 5.83 A dc (0.01) A @ 11.7, 23.3, 35, 70, (140)* A dc * Maximum power delivered at high source range AC Amplitude Accuracy @ 50-60 Hz @ 20-30 C Phase Angle @ 50/60 Hz Frequency Typical Guaranteed Range Accuracy Resolution Bandwith Range Resolution 0.02% of reading +.01% of range 0.09% of reading +.04% of range Convertible Source in Current Mode @ 20-30 C Guaranteed <0.5% (+359.9 ) -(0 ) - (-359.9 ) Distortion @ 50/60Hz V & I Sources Total Harmonic Distortion (THD) Typical ± 0.25 ± 0.1 Guaranteed <0.02% <0.1% DC - 3kHz at Full Power DC, 0.1 Hz - 2.0 khz Continuous Full Load Accuracy 0.001 Hz Typical @ 20-30 C @ 0-50 C 0.5 ppm 1.5 ppm 10 ppm

Logic Inputs (Voltage or Contact Sense) Total Inputs: 8* Isolated Inputs Inputs: 2 (First Strike) Voltage Sense: 250V RMS AC / 300V DC Open Circuit Test Voltage: 12V DC Short Circuit Test Current: 20mA DC Response Time: 0.1 msec max pickup /dropout Input Impedance: 150KΩ Isolation: ± 500V peak Paired Inputs Inputs: 3 Pairs (6) Voltage Sense: 250V RMS AC / 300V DC Open Circuit Test Voltage: 4V DC Short Circuit Test Current: >50mA DC Response Time: 0.1 msec max pickup /dropout Input Impedance: 150KΩ Isolation: ± 500V peak * Additional 8 inputs available with F6816 option Input Range: Metering Functions DC Meter Inputs 0 - ±10V DC / 0 - ±20mA DC Typical: <0.003% Guaranteed: <+0.05% Typical: Frequency: Pulse width: AC Sources <0.02% of metering loads Logic Input As Counters 10 khz >175 µsec Logic Outputs Type: FET (High Speed Electronic) Relay Number: 4 4 Isolation Voltage: ±500V peak ±500V peak Response Time: 0.1millisecond pick up /dropout <10 millisecond pick up /dropout Maximum (Make/ Break Current): 0.5 amps (Breaking cap AC: 2000 VA with Vmax 250V, Imax 8 A) (Breaking cap DC: 50W with Vmax 300 V, Imax 8A) Input Voltage: 250 V RMS 250 V RMS Variable Output Battery Simulator Range: 6-300V DC Resolution: 0.3V Power: 90 W, 1.5 A max 50/60 Hz Ripple: <0.2% of Range Accuracy: <± 5% (AIM) Analog Input Measurement (F6820 Option) Recording: Internal Source recording: Ranges: Bandwidth: Input Impedance: Max Input Voltage: Isolation: 8 external Analog or Digital Signals 12 Sources 250 mv, 2.5V, 25V, 250V RMS DC, 0-5kHz 150KΩ 250V RMA AC / 300V DC ± 500V peak channel to channel Accuracy Typical: ±0.06% Maximum: ±0.15% Timing and Trigger Timers Number: 8 Max Recording Time: Accuracy: Resolution: <24 Hours ±0.0005% of reading, ±50 µsec 100 µsec General Specifications Enclosure: High-impact, molded, flame-retardant ABSmeets National Safe Transit Association testing specification No.1A for immunity to severe shock and vibration Environmental: IEC 60068-2-2 Dry Heat (+85 C storage; + 50 C Rating Operating), IEC 60068-2-1 Cold (-50 C storage; 0 C operating), IEC 60068-2- 30 Damp Heat (+55 C, 6 cycles, 95% humidity), NEMA Enclose Rating Type 1IEC Enclosure IP20 Electrostatic Discharge Immunity: IEC 801-2 I.E.C. performance level 1 @ 10kV: normal performance within specifications. I.E.C. performance level 2 @ 20kV: no permanent damage. IEC61850 GOOSE: Certified by KEMA as being compliant with IEC61850 protocol (IEC61850-7-2 and 8-1) Mechanical: IEC 60068-2-27 Shock (15g/11ms, half sine) IEC 60068-2-6 Vibration (10-150 Hz, 20m/s2) IEC 60068-2-6 Drop Test EMC Emissions: FCC 47 CFR Part 15 Class A (USA), EN55011:1998/A1:1999/ A2:2002 Group 1 Class A ISM(EU), AS/NZS CISPR 11:2004 Class A ISM (Australia), ICES-001 Issue 3 ISM (Canada) Surge Withstand Capability: ANSI/IEEE c37.90. The simulator functions as a source during surge withstand capability tests, when the ANSI/IEEE specified isolating circuit is interposed between the simulator and the test relay. IEC61850 Sample Values (Publishing): 80 samples per cycles for nominal frequencies 50Hz and 60Hz using GPS time synchronized signals Weight: Dimensions: Calibration: 42lb,19.05kg (front cover and strap included) 15 X 9.5 X 18 inches, 38 X 24 X 45.7 cm Certification traceable to N.I.S.T. standards EMC Immunity: Quality Assurance Management System: Humidity: EN 61000-6-2:2005; IEC 61000-4- 2/3/4/5/6/11 Third Party certification to ISO 9001:2000 Up to 95% relative humidity, non-condensing Line Power Supply: Safety: 105-264V, 47-63 Hz EN 61010-1; UL 61010-1; CSA 27.2 # 61010-1 Communication Interfaces (Ethernet, Wi-Fi, USB) Ethernet or USB control to PC, Wi-Fi (802.11 B+G bands, 30-80ft, 9-24m) Doble Engineering Company Worldwide Headquarters 85 Walnut Street Watertown, MA 02472 USA Tel: +1 617 926 4900 Fax: +1 617 926 0528 www.doble.com MKT-SL-F6150SVTS-1/13