WALL OR WINDOW EXTRACT FANS Series Complete range of axial flow fans for wall or window mounting applications. All the fans are supplied with tough ABS plastic grilles, shutter and single phase V- 5Hz motor. All the fans are class II insulation and IPX4 rated. The series comprises of diameters: 5, and mm, including several operating options, making them ideally suited for a wide range of general residential, commercial and industrial exhaust or supply ventilation applications. Shutter Reversible Natural ventilation position To prevent air entry and limit heat leakage when the extractor is not operating Extract or supply operation Shutter open, fan off Elegant design harmonising with any environment 7
HV- AE versions Standard range HV-M versions - Single-phase motor V5Hz with thermal overload protection - Single operation - Class II insulation - Model and are reversible with CR-5 control accessory - Automatic, thermally actuated shutter HV-5 AE: Positions: OFF - Fan OFF, shutter closed ON - fan ON, working as air extract with shutter open HV- AE: positions (with CR-5 control accessory) HV- AE OFF - Fan OFF/Shutter closed ON - Fan ON/shutter open Fan working as air extract/supplying air REB-R control: Speed controller including a switch to reverse the airflow direction Manually operated models via integral pull cord - Single (HV-5M) or - (HV-M and M) operation - Model and are reversible - Natural ventilation position (shutter open, fan off - except HV-5M) - Neon lights indicating the mode of operation HV-5 M: Positions: Fan OFF, shutter closed Fan ON, working as air extract with shutter open HV- M: HV- M 5 Positions: -Fan stopped and shutter closed -Fan on high working as air extract with shutter open -Fan on low working as air extract with shutter open 4-Fan stopped and shutter open 5-Fan in reverse high supplying air in the room with shutter open HV-A versions Automatic models operated via control unit CR - Single (HV-5A) or - (HV-A and A) operation - Model and are reversible - Natural ventilation position (shutter open, fan off) - Neon lights indicating the mode of operation HV-5 A: Positions: - Fan OFF, shutter closed - Fan OFF, shutter open - Fan ON, working as air extract To operate all these functions use the accessory CR-5 HV- A: HV- A 5 Positions: -Fan stopped and shutter closed -Fan on high working as air extract with shutter open -Fan on low working as air extract with shutter open 4-Fan stopped and shutter open 5-Fan in reverse high supplying air in the room with shutter open To operate all these functions use the accessory CR- 7
HV-RC versions Radio control range - Two operation - Natural ventilation position - All model are reversible - Automatic, thermally actuated shutter - Neon light mode of operation indication HV- RC: HV- RC 6 Positions: -Fan stopped and shutter open -Fan stopped and shutter closed -Fan on high working as air extract with shutter open 4-Fan on reverse high supplying air in the room with shutter open 5-Fan on low working as air extract with shutter open 6-Fan in reverse low supplying air in the room with shutter open HVE versions Flush mounted version HVE- AE: same positions that HV- AE HVE- A: 5 same positions that HV- A HVE- RC: 6 same positions that HV- RC STYLVENT Product Summary Operational Specifications Model Flush Single Two Natural Pull Electrical accessories Radio mounted Reversible ventilation cord REB-R CR-5 CR- control HV-5 M HV- M HV- M HV-5 AE HV- AE HV- AE HV-5 A HV- A HV- A HV- RC HV- RC HVE- AE HVE- A HVE- RC Maximum ambient operating temperature for all models: 45ºC. One remote control can operate several HV.RC. In that case, the fans must be installed with a minimum distance of,5 meters between fans. 7
Technical characteristics Model Dimensions (mm) Speed (tr/mn) G F Maximum absorbed power (W) Maximum absorbed current (A) High Airflow rate (m /h) Extraction Low Intake Sound pressure level at m (db(a)) High Low HV-5 AE 8,9 5 - - 9 -, HV-5 M 8,9 5 - - 9 -, HV-5 A 8,9 5 - - 9 -, HV- AE 5 4,5 6-4 -,5 HVE- AE 5 4,5 6-4 -,5 HV- M 5 4,5 6 45 4 7,5 HV- A 5 4,5 6 45 4 7,5 HVE- A 5 4,5 6 45 4 7,5 HV- RC 5 4,5 6 45 4 7,5 HVE- RC 5 4,5 6 45 4 7,5 HV- AE 5 68, - 7 46-5, HV- M 5 68, 75 7 46 8 5, HV- A 5 68, 75 7 46 8 5, HV- RC 5 68, 75 7 46 8 5, Weight Model A B C ø D E F G H Min. Max. Min. Max. Min. Min. HV-5 5 9 87 9 5 6 5 (kg) Ø D on (no the vidro) glass B HV- 5 4 59 6 5 85 HV- 68 4 5 7 5 H A E C Dimensions of the HVE flush mounted version 7 6 6 7 67 56 8 7
Installation in glass or panels from to 5 mm thickness Fast and simple three stage installation The STYLVENT series of fans are designed for of installation in three easy stages. Stage - External grille Once in position, the external grille is held by three rubber plugs which allow the installer to assemble the interior section of the fan. Stage - Support frame To enable easy mounting of the support frame, the holes are tapered and the fixing screws can be located depending on the glass/panel thickness: mm< thickness< mm mm<thickness<5 mm Stage Internal grille Finally, place the lugs on the top of the support frame into the rectangular slots on the front grille it into position. For a wall mounted installation it is necessary to use the extended threaded rod set (see Installation accessories) Installation on walls from 5 to mm thick Before installation, rods must be cut to 5mm less than the thickness of the wall. Cut a hole in the wall in accordance with the dimensions shown in the table (to right). Ensure that internal wall mounting surface is as smooth as possible. On the interior of the wall, mark the fixing hole positions using the support plate as a template. Fit the threaded rods to the external guard using the threaded sleeves. Place the external grille into position and hold in place with the rubber plugs. Then, the installation follows the same stages as in the glass installation except for the support frame installation, which has to be fixed using or 4 screws (HV-5, HV- and HV- models respectively). Ø D Model Ø D H* L* Min. H Max. HV-5 87 9 7 HV- 59 6 5 65 HV- 7,5 57, * There are only two diagonal fixing holes for model HV-5. L 74
Performance curves Q = Air volume in, m /hr and m /s. Ps = Static pressure in mmwg and Pa. Dry air at ºC and 76 mmhg. Tests carried out according to UNE --89 and BS 848 part. Pst Pst Pst Pa mmwg HV-5 Pa P mmwg HV- Pa P mmwg 6 8 9 6,8 8 9 5 4 5,5 5,8 4,5 4,,5,,5,,5,,5, 5 5 5 m /h Q,,,,4,5,6 m /s - Extraction on high. - Extraction on low. - Air intake Acoustic characteristics 7 6 5 4 7 6 5 4 4 5 6 m /h Q,,4,6,8,,,4,6 m /s 8 7 6 5 4 8 7 6 5 4 HV- 4 6 8 m /h Q,5,,5,,5, m /s The values shown for the Sound Pressure Levels in the technical characteristics table are measured in db(a) at m (position B) as shown in the diagram. A m B The table below shows the necessary corrections to calculate the Sound Power Level Spectrum SWL, at the inlet (point A) and outlet at high (in Hz). B Inlet Lw(A) 5 5 5 4 8 HV-5 +5,5 + +6 +4 + +7 +4,5 HV- +9 +,5 +,5 +6,5 +,5 +5 +,5 HV- +7 +8,5 +4 +6,5 + +6 -,5 Outlet Lw(A) 5 5 5 4 8 HV-5 +6,5 +,5 +8,5 +6,5 +4,5 +8 +4,5 HV- +6,5 + +6,5 +8 +5 +6,5 +,5 HV- +5,5 +,5 +7 +9 +5 +6,5 75
Electrical accessories CR-5 Control unit for HV-5 A Fitted with: On/off switch for fan operation. ( - ) On/Off switch for shutter operation One single CR-5 unit can operate up to 5 HV-5 fans. CR- Control unit for HV- A, HV- A and HVE- A Fitted with: A selector for the different modes of fan operation (,,, ) A reversing switch to change the airflow direction (, ) One single CR- unit can operate up to 5 HV- or fans. REB-R Speed controller including a switch to reverse the airflow direction. Only to be used with models HV- AE, HV- AE and HVE- AE Max A. Connection cable A (7) core wire cable for the connection of models HV- A and HV- A to the remote control unit CR-. (Supplied on m rolls as standard) Installation accessories Threaded Rod set Threaded rods and sleeves for use when installing the HV fans on walls from 5 mm up to mm thick Model Electrical supply IP Power Maximum Class Temperature Dimensions Frequency Voltage protection current (mm) (Hz) (V) (VA) (A) L A H REB-R 5-4 IP-4 4 II ( ) -4ûC 6 58 88 Control unit CR-5 88 47 88 Control Unit CR- 58 57 88 76