July Funk-Electronic Piciorgros GmbH

Similar documents
TMO-100 Telemetry, SCADA and Telecontrol using Tetra-Infrastructure. September 9th, 2011 DFW, USA

TMO-100 Telemetry, SCADA and Telecontrol using Tetra-Infrastructure. 05 September 2011 Mexico City, Mexico

TETRA - the best choice for narrow band wireless SCADA and IP-communication

TETRA Special Solutions: RF Coverage-Test and Coverage-Simulation Digital Voice Interface Telemetry and SCADA Solutions. Bangkok, June 2015

Johan Hoolsema Expert System Solutions

Who is actually using TETRA for SST?

The SCADA Connection: Moving Beyond Auto Dialers

Professional TETRA Data Modem TMO-100 and TETRA Test Set

Reliable supply Telecontrol technology in the gas network

An Optimum Solution for Telemetry of Distributed. Wells in South of Tehran

Wireless Data Communications for SCADA Systems

Intelligent Remote Terminal Unit (irtu) in the IoT Era

The SCADA Connection: Moving Beyond Auto Dialers

Connectivity 101 for Remote Monitoring Systems

M400g GPRS Modem Datasheet

Specialized in the design & manufacturing of wireless

I/A Series Remote Terminal Unit (RTU) RTU 20 for Oil, Gas, and Water SCADA Applications

TETRA in Energy Refineries, Oil & Gas. Gary Lorenz

Simplifying Control of your Water Treatment Plant Wireless SCADA System Case Study

What is SCADA? What is Telemetry? What is Data Acquisition? Differences between SCADA and DCS? Components of SCADA. Field Instrumentation

SCADA OVER TETRA. Patrick Colling May 2016

InstrumentationTools.com

M300td 3G TD-SCDMA Modem Datasheet

INDUSTRIAL CONTROL SYSTEMS & COMPUTER PROCESS CONTROL

Chapter 6: DNP Introduction. 6.2 Features of the DNP The OSI/ISO model. 6.3 Basic topology

Cambium Networks and IIoT Industrial IOT di Cambium Networks come soluzione Privete Network su Narrow-Band. Maximilian Moccia RTM Italy & Med.

Baer Meter2SCADA. Meter2SCADA

/ sicam SICAM CMIC The smart cube for your distribution network Answers for infrastructure and cities.

June 2018 System Planner

Next Generation Telemetry Systems Improve Utility Effectiveness

M400gsm GSM Modem Datasheet

UNDERSTANDING THE ADVANTAGES OF IP NETWORKS

Advances in Telemetry. Finding out what is really going on in your system

Weightless: The emerging global wireless standard for linking sensors and devices

ICx Gateway: Sample Implementation

IT and Instrumentation for industry. Modular RTU Controller: IoPAC 8000 Series. Cellular RTU Controller: iologik W5300 Series

OPTIMUM ENERGY PTE LTD

POWER-ONE ITALY, 5 TH JUNE 2018 Cloud, Big Data & Cyber Security. Business, Opportunities and Risks

The RTU for small utility applications featuring EN/IEC protocol RTU870

ControlEdge RTU Process Controller Product Information Note

Distributed Generation Requirements Update

Preconfigured SCADA solution: Easy & Powerful

Authorized Systems Integrator. Automation Systems Telemetry & SCADA

Kepware Whitepaper. A New Distributed Architecture for Remote Communications

Communication Protocols for Opto 22 Products

SCADA Solutions for Water and Wastewater Treatment Plants

Siemens AG Industrial Remote Communication. Telecontrol. Efficient Telecontrol Solutions. Edition 11/2017. Brochure. siemens.

Moxa Inc. Moxa Americas Moxa China Shanghai Office Beijing Office Moxa Europe Shenzhen Office Moxa Asia-Pacific

Bilfinger Mauell GmbH. smartrtu ME 4012 PA-N

SCADAPack DNP Driver. User and Reference Manual

REF IC012 PLC & SCADA Systems Feb $4,250 Abu Dhabi, UAE

Wireless IoT Sensing Solutions

Training Fees 4,250 US$ per participant for Public Training includes Materials/Handouts, tea/coffee breaks, refreshments & Buffet Lunch

WIRELESS REMOTE ASSET MONITORING & CONTROL

MOSCAD WIRELESS MONITORING AND CONTROL SOLUTIONS FOR THE WATER/WASTEWATER INDUSTRY

Information Management and Metering Solution for CGD

Automate and Preserve Electromechanical Relay Investment Part 3 of 3 Using the Bitronics 70 Series to Improve Remote Monitoring and Control

SCADA Preprocessors. Introduction to SCADA Preprocessors. The Modbus Preprocessor

GE Intelligent Platforms PAC8000 RTU

Sigbert Reimann, Remote Control Forum, Datum 9. October 2013 RTU - Review and News. ABB Network Management Forum December 10, 2013 Slide 1

Advantages of the DNP3 Communications Protocol

Asset Management. Facility Management. Total Solutions. Supply Chain Management. Utilities. Series 4500

Tait GridLink THE INTELLIGENT CHOICE FOR DISTRIBUTION AUTOMATION. harris.com #harriscorp

R-Win Wireless Communication Management System

From Wikipedia, the free encyclopedia

Low Power Wide Area Network (LPWAN) Presented By: Dr. Hafiz Yasar Lateef Director, Telxperts Pty Ltd.

ICS Humla CTF. Copyright 2017 Payatu 1

Telecontrol and Automation Systems

Plant / field level Process

Telemetry and Remote SCADA Solutions

WebAccess DNP3 Master Ethernet Driver Guide. Advantech WebAccess. - DNP3 Master Ethernet Driver Guide Version: 1.01

RTU-710H Wireless I/O Module With On-Off and Analog I/O. Version 4.30

GenIP : Intelligent gateway dedicated to most critical industrial applications

Telemetry & SCADA Handbook

RTU modules Create your infrastructures with peace of mind!

High performance monitoring & Control ACE3600 Remote Terminal Unit

Evolution of SCADA Networks

Chapter 2 Communication for Control in Heterogeneous Power Supply

The Next Level of Energy Data Management Fast Data Acquisition via Parameterization No Programming

Madrid, 25 y 26 de mayo de 2015 ABB Automation Days Wireless Instrumentation

Estates & Facilities Utilities Meters - Performance Specification

Virtualizing Industrial Control Systems Testbeds for Cybersecurity Research

COMPANY PROFILE

Fax: +30 (210) Tel Fax

21 st Century Landfill Technology: Telemetry, Automation, and Alternative Power Sources

Jim Baker SCADA Acquisition Manager, Water Corporation WITS Protocol Standards Association Committee member DNP3 Technical Committee member

Using Operator Interfaces to Optimize Performance of Industrial Wireless Networks

w w w. z i g s e n s e. c o m. a u

Architecture for SCADA with Mobile Remote Components

Intelligent vibration monitoring.

SCADA.What s out there?

ADVANCED SCADA CONTROL SYSTEMS

Efficient Design of SCADA Systems Using Minimum Spanning Trees and the NFR Framework

SCADA Solutions Since 1981 DATA FLOW SYSTEMS

CONTENTS... 2 COMTROLL SAS. SURVEILLANCE AND AUTOMATION SYSTEM...

Introduction to RTU Controllers

SCADA and Central Applications An introduction

IE102: SCADA Programming, Maintenance & Troubleshooting

SCADA System Specification. Vantage Pipeline Project # May 2013

Training Venue and Dates September, 2019 $4,000 Dubai, UAE PLC & SCADA Systems Trainings will be conducted in any of the 5 star hotels.

Transcription:

Techniques how to increase the speed for Data Communication in SCADA and Telemetry Applications using Tetra one Infrastructures July 2010 Funk-Electronic Piciorgros GmbH

1. Tetra Telemetry Applications 2. SCADA Configurations using Tetra Infrastructure 3. SDS based Radio-to-Radio Communication 4. SDS based Switch to Radio Communication 5. Packet Data Communication 6. Comparison of Data Communication with Packet Data and SDS 7. Pro and Contra SDS / Packet Data 8. Increasing the number of polled outstations to over 120 per minute

Wireless Applications Water Management pump controlling, ground water monitoring barrage, canal monitoring Gas-, and Oil pipelines pressure, flow management Utility Companies Power Distribution, Line Switches Control Facility management / Real Estate Airports, Public Places Traffic Monitoring, management and control Trans-Rapid, parking management, traffic jam monitoring Environment protection Rain measurement, water level Agriculture Watering systems, Ice warning systems

Surface Coal Mining (Water Level Control)

GAS Flow Control with Solar Power (Germany)

GAS Quality Control

Waste Water Monitoring Treatment Plant

1. Tetra Telemetry Applications 2. SCADA Configurations using Tetra Infrastructure 3. SDS based Radio-to-Radio Communication 4. SDS based Switch to Radio Communication 5. Packet Data Communication 6. Comparison of Data Communication with Packet Data and SDS 7. Pro and Contra SDS / Packet Data 8. Increasing the number of polled outstations to over 120 per minute

SCADA (Supervise Control and Data Acquisition) The term SCADA basically includes the whole system starting from the Monitors and Computers in the Control Room, the Interfacing to the Infrastructure, the Infrastructure itself, up to the Outstations the PLC c and Sensors or Actors. The following Slides will demonstrate how the SCADA Control Room Part can be interfaced to Tetra Infrastructure using different options and how the data communication speed can be optimized.

SCADA transmitting Text Message to Tetra Terminal

Tetra Point-to-Point I/O to I/O connection with Embedded Micro-PLC Transmission of 16 Inputs an 8 or 16 Outputs and optional four analog I/O Transmission of 16 Inputs an 8 or 16 Outputs and optional four analog I/O

Tetra Point-to-Point PLC to PLC connection using standard Protocols as Modbus RTU, DNP3, EN 60870-5-101, PakBus, SPS SPS

Automatic Transmission and Recording of Counter Values (Flow, Pressure, Heat Evonic Germany) TRM-710 mit RS-232 oder RS-485/422

Tetra Data Network with OPC Server Windows PC Mit OPC Server TRM-710 mit RS-232 oder RS-485/422 TRM-710 mit RS-232 oder RS-485/422 RTU-710 Funkbaugruppe mit integrierten E/A

1. Tetra Telemetry Applications 2. SCADA Configurations using Tetra Infrastructure 3. SDS based Radio-to-Radio Communication 4. SDS based Switch to Radio Communication 5. Packet Data Communication 6. Comparison of Data Communication with Packet Data and SDS 7. Pro and Contra SDS / Packet Data 8. Increasing the number of polled outstations to over 120 per minute

SCADA using SDS based Radio-to-Radio Communication Control Room in P2P Application Serial Communication TMO-100 TMO-100 Public Lighting Tetra Switch

Polling-Timing in P2P Communication (Modbus RTU, DNP3, IEC60870-5-101, PakBus, ) Master M->1 M->1 M->1 M->1 M->1 M->1 Outst._01 1->M 1->M 1->M 1->M 1->M 1->M Time Line Timing does not fit to Scale

SCADA using SDS based Radio-to-Radio Communication Control Room in P2MP Application Public Lighting TMO-100 Serial Communication TMO-100 TMO-100 Command and Control Line Device AMR Tetra Switch TMO-100

Polling-Timing and Broadcast in M2MP Communication Master M->1 M->2 M->3 M->1 M->ALL M->ALL M->ALL Outst._01 1->M 1->M Rx_ALL Rx_ALL Outst._02 2->M Rx_ALL Rx_ALL Outst._03 3->M Rx_ALL Rx_ALL Time Line Polling Sequence. Data is sent only to one receiver at a time Broadcast. All Units receive and act at the same time Timing does not fit to Scale

Analyze one Polling Sequence Master M->1 M->2 M->3 M->1 M->ALL M->ALL M->ALL Outst._01 1->M 1->M Rx_ALL Rx_ALL Outst._02 2->M Rx_ALL Rx_ALL Outst._03 3->M Rx_ALL Rx_ALL Time Line Polling Sequence. Data is sent only to one receiver at a time Broadcast. All Units receive and act at the same time Timing does not fit to Scale

Data Flow with Radio-to-Radio Communication Polling Sequence. Data or Request from the Master device to the Outstation Data received from the Outstation Master RS-232 RS-232 Tetra Uplink Downlink Tetra Downlink Uplink Outstation RS-232 RS-232 Time (typical): 2,5 to 3,5 Sec for about 20 Byte Polling Data and 150 Bytes answer from the Outstation Time Line Timing does not fit to Scale

1. Tetra Telemetry Applications 2. SCADA Configurations using Tetra Infrastructure 3. SDS based Radio-to-Radio Communication 4. SDS based Switch to Radio Communication 5. Packet Data Communication 6. Comparison of Data Communication with Packet Data and SDS 7. Pro and Contra SDS / Packet Data 8. Increasing the number of polled outstations to over 120 per minute

SCADA using an SDS Gateway Control Room Public Lighting TMO-100 Two Serial Interfaces TGW-100SDS SDS Gateway IP Communication TMO-100 Command and Control Line Device AMR Tetra Switch TMO-100

Data Flow with Gateway-to-Radio Communication Polling Sequence. Data or Request to the Outstation Data received from The Outstation Master RS-232 RS-232 Tetra Downlink Uplink Outstation RS-232 RS-232 Time (typical): 1 to 2 Sec for about 20 Byte Polling Data and 150 Bytes answer from the Outstation Time Line Timing does not fit to Scale

Access Time for Polling Protocols using SDS Communication: Using radio-to-radio communication and an average of about 3 seconds per polling cycle, about 20 outstations can be accessed per minute. Using gateway-to-radio communication and an average of about 1,5 seconds per polling cycle, about 40 outstations can be accessed per minute.

1. Tetra Telemetry Applications 2. SCADA Configurations using Tetra Infrastructure 3. SDS based Radio-to-Radio Communication 4. SDS based Switch to Radio Communication 5. Packet Data Communication 6. Comparison of Data Communication with Packet Data and SDS 7. Pro and Contra SDS / Packet Data 8. Increasing the number of polled outstations to over 120 per minute

SCADA using an Packet Data Gateway Control Room Public Lighting TMO-100 Two Serial Interfaces TGW-100P Packet Data Gateway IP Communication TMO-100 Command and Control Line Device AMR Tetra Switch TMO-100

SCADA using direct IPCommunication Control Room Public Lighting IP TMO-100 Direct IP Communication TMO-100 IP Command and Control Line Device IP AMR Tetra Switch TMO-100

1. Tetra Telemetry Applications 2. SCADA Configurations using Tetra Infrastructure 3. SDS based Radio-to-Radio Communication 4. SDS based Switch to Radio Communication 5. Packet Data Communication 6. Comparison of Data Communication with Packet Data and SDS 7. Pro and Contra SDS / Packet Data 8. Increasing the number of polled outstations to over 120 per minute

What about the difference between SDS Communication and Packet Switched Data? Facts: 1) SDS communication is using the Control Channel to carry the data 2) With Packet Data, the Control Channel is only used to organize the communication, while the data is fed through the Traffic Channels 3) Using the same amount of Data and the same protocol, in practice there is no big difference between SDS and Packet Data communication. (Packet Data is slightly faster)

When does it make sense to use SDS Communication? 1) If the infrastructure does not support Packet data 2) On Event Driven Communication with little traffic (low network load) 3) On a low to medium number of Telemetry Devices per Base Station, and high priority for Voice Communication the SDS Data Communication has the advantage that the Traffic Channels are available all the time for voice calls. 4) If Secondary Control Channels are available

When does it make sense to use Packet Data Controlled Communication? 1) If the infrastructure does not support Secondary Control Channels and the number of outstations per Base Station is high 2) If Data Communication has priority against Voice Communication (pure data network) 3) If there are available enough Channels (Carriers) per Base Station

1. Tetra Telemetry Applications 2. SCADA Configurations using Tetra Infrastructure 3. SDS based Radio-to-Radio Communication 4. SDS based Switch to Radio Communication 5. Packet Data Communication 6. Comparison of Data Communication with Packet Data and SDS 7. Pro and Contra SDS / Packet Data 8. Increasing the number of polled outstations to over 120 per minute

Pro and Contra SDS Communication: 1) + it is easy to implement in Radio-to-Radio links as there are the same and exactly defined conditions on all infrastructures (air interface) 2) + it does not affect the Traffic Channels 3) - SDS Gateways are difficult to implement, as there is no standardized interface on the Tetra Switches 4) - with a high number of outstations or huge amount of data, the Control Channels will be overloaded 5) - the SDS size is limited on some manufacturers to 140 or 160 Bytes (a maximum of 254 bytes is specified in Tetra)

Pro and Contra Packet Data Communication: 1) + a Packet Data Gateway is easy to be connected to a Tetra infrastructure (Switch) as it only operates on IP communication 2) + IP Communication is easy to manage 3) + if there are enough traffic channels per Base Station, many outstations can be serviced and a huge amount of data can be carried without affecting the Control Channel 4) - complex Modems or Outstations are needed (Embedded Router, Port Forwarding, NAT, IP-Stack, ) 5) - if voice has priority the communication can be affected if there is high voice traffic

Increasing the number of polled outstations to over 120 per minute 1) Choose direct IP Communication or a Packet Data Gateway, directly connected to the Tetra Switch 2) Choose IP Communication or Serial (RS-232) over Packet Data Communication 3) Spread the consecutive polling's over different Base Stations 4) Poll one device after the other without waiting for each response 5) Poll every 0,5 seconds

Modified Polling-Timing to increase the number of polled Outstations per Minute Master M->1 M->2 M->3 M->1 Outst._01 1->M Outst._02 2->M Outst._03 3->M Time Line Polling Sequence without waiting for the response Response with maximum Speed Timing does not fit to Scale

Funk - Electronic Piciorgros GmbH Claudiastr. 5 51145 Köln-Porz Germany www.piciorgros.com