QuantumR Light Management Hub

Similar documents
QuantumR Light Management Hub (QP2)

Light Management Hub. Quantum 230 V CE Light Management Hub. Centralized Control Equipment

Quantum Light Management Hub (QP3) for Quantum Select

EcoSystem One-Line. EcoSystem C5-XPJ-16A Switching Power Module

Energi Savr Node with DALI for Quantum

QSNE-2DAL-D Energi Savr Node QSTM 20 V. DALI Loop 2. seetouch QS Wallstation Energi Savr Node QS. QS Control Link

CS XL XM. EcoSystem Bus Supply

QSE-CI-DMX Control Interface

Energi Savr NodeTM QSN-2ECO-PS120 EcoSystem with Shades ESN a

Energi Savr NodeTM Programming Interface

HomeWorks QS Processor

QSE-CI-NWK-E Control Interface

GRX-CI-RS232 Control Interface

GRAFIK 5000P / 6000P / 7000P Processor Panel

Hi-lume Premier 0.1% EcoSystem LED Driver

10-Output Configurable Smart Panel

EcoSystem to 0 10 V- Interface

GRX-CI-NWK-E Control Interface

EcoSystem Digital Ballasts

Energi Savr NodeTM for 0 10 V Energi Savr NodeTM with Softswitch

HomeWorks QS Processor

QSE-CI-DMX Control Interface

Sivoia QS Wireless Smart Panel

Energi Savr Node for DALI QSNE-2DAL-D DALI Fixture Controller V. Photo

QSWA-KP5-DW- 5 Button Wallstation with Raise/Lower

UL Listed Hi-lume A-Series Constant Voltage Driver Overview

Hi-lume A-Series Driver Overview EcoSystem or 3-wire control

LUT-DMX DMX512 Control Interface

QSWE-2BN- - QSWE-2BI- - 2-Button Wallstation

LQSE-4S8-120-D. 120 V~ 50 / 60 Hz 16 A. lutron.com LQSE-4S8-120-D. Dimming Power Module. Option. Input. Opt Def H M

LCP128 Dimming and Switching System

PowPak Single Zone Control Module with EcoSystem

Hi-lume 1% EcoSystem Constant-Voltage 24 V- LED Driver with Soft-on, Fade-to-Black Dimming Technology

OMX-CI-RS232 Control Interface

Lutron Residential and Commercial Systems Rules

GRX-CI-NWK-E Control Interface

HomeWorks QS Wired seetouch Designer Keypads

HomeWorks QS GRAFIK T QS Slider

HomeWorks QS Wired ArchitraveTM Keypads

24V Power Pack. Applications. Features. Specifications. Certifications & Affiliations. Catalog #: ALPP 24VCC Part #:

product specifications d

HomeWorksR QS Dynamic Keypads

System Overview. EcoSystemTM Bus. IR Receiver. Occupant Sensor. IR Remote 1 Supplied by others

GRAFIK Eye QS Wireless

*Recommendations are subject to change. Consult your Lumenetix representative for the most updated list. Eco Loop 1. Eco Loop 2. Wallstation.

20AMP Plug Load Controller

HomeWorks QS Visor Controls

OMX-CI-NWK-E Control Interface

HomeWorks Remote Power Feed-Through Panels

HomeWorksR QS 1-Link Processor

HomeWorks Wired Signature Series Keypads

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

Specialized Lighting Solutions, Inc. SLS DALI CONTROLLERC

Back Room Equipment INTRODUCTION SPECIFICATION & DESIGN FRONT ROOM BACK ROOM APPENDIX

5AMP Power Pack. Applications. Features. Specifications. Certifications & Affiliations. Catalog #: ALPP 5ACC or ALPP 5A Part #: or

GRX-3000 Control Units

Power Boosters and 120 V Interfaces

GRAFIK Eye 3000 Series Control Unit

RadioRA 2 Visor Controls

Wallbox Power Module. 4/8 Series Remote Dimming Controls Grafik Eye /WPM Link N/A INTRODUCTION SPECIFICATION & DESIGN FRONT ROOM BACK ROOM APPENDIX

Wallstations for use with Grafik 3000 and 4000 Series Systems

RadioRA 2 Visor Controls

HomeWorks Wired seetouch Keypads (Domestic Models)

PJ24BWHL21P Pico Pro 4B 2 Group Light. Features. Material, Color, and Finish. Dimensions and Weight. Descriptions. Manufacturer Information

SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

EGRX-2B-SL- - 2-Button Wallstation

QS Link power supply. Lutron QS. Link Power Supply

with EcoSystem Control Unit

BCM2 Series Branch Circuit Monitors Quick Setup Guide

QSWS2-1BN- - QSWS2-1BI- - 1-Button Wallstation

GRX-PRG Programming Control Interface

Quick Installation and Operation Guide. Control Unit. Please Read. Contents

QS Sensor Module. product specifications a Model Numbers

GR 2400 PLANNING GUIDE. Important Note:

LED Recessed Downlights 12 W LED Round: Fixed or Tilt Downlights 12 W LED Square: Fixed or Tilt Downlights

clarity 3 Programmable Controller

CasétaTM PD-5WS-DV. SPECIFICATION SUBMITTAL Page Job Name: Model Numbers: Job Number: Receiving Device

LCP128 Dimming & Switching System

Switched Relay Controller - Relay Panel with Breakers

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

Pico 4-Button Wireless Remote

PHS Series. PowerHUBB Node - Satellite

RadioRA 2 Wall-mount Designer keypads

Dimmers with Neutral Wire for Halogen, Incandescent, ELV, or Interfaces

Energi Savr Node with Softswitch Design and Application Guide

SS-1BI-GWH-E00 1-Button Wallstation

Satellite INSTALLATION GUIDE

Energi Savr Node with Softswitch Design and Application Guide

Surge Protective Devices. STV100K Series. Instruction Manual

Occupancy and Vacancy Sensors ROOM CONTROLLER* DAYLIGHT SENSOR WPP-INT INSTALLATION GUIDE

Surge Protective Devices. STV100K Series. Instruction Manual

PHM Series. PowerHUBB Node - Master/Control

IMPORTANT SAFETY INSTRUCTIONS

Pico Wireless Control and Mounting Accessories (for regions other than North, Central, and South America)

EA500. Installation Instructions Transponder

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

FB-6SP and FB-12SP. Block device couplers. Data sheet 3177_en_A. 2 Features. 1 Description

Pico 4-Button Wireless Remote

DMX, 2 CHANNEL 2 Channel DMX Driver

GRAFIK Eye QS Wireless Control Unit (230 V Limited 434 MHz) Mechanical Dimensions. Preset Dimming Controls

Transcription:

Quantum 369375e 1 04.02.2015 QuantumR Light Management Hub The Quantum light management hub provides a centralized connection point for Lutron EcoSystem digital ballast modules, Lutron power panels, GRAFIK Eye QS, and Sivoia QS shades. Features Designed to control, manage, and monitor EcoSystem lighting, Energi Savr NodeTM with EcoSystem, Lutron power panels, GRAFIK Eye QS, and Sivoia QS shade systems in a building or whole campus. Supports both astronomic and time-of-day events to automatically control the lights and shades in the system. Simple reconfiguration of a space without rewiring. Individually control, monitor, and adjust any light or shade in a space. QS control links and EcoSystem loops are topology-free. For EcoSystem loads, the light management hub accepts one normally closed (NC) emergency input per Quantum bus supply. EcoSystem bus may be wired NEC Class 1 or IEC PELV / NEC Class 2. Panel Capabilities Each hub supports up to 8 EcoSystem loops, (4 Quantum bus supplies). Each loop can have a combination of 64 EcoSystem ballasts and ballast modules, plus a maximum of 16 daylight sensors, 32 occupancy sensors, and 64 infrared (IR) devices. Supports up to 2 Quantum processors with 2 links each that can be individually configured to communicate with: - Quantum bus supply (limited to one link per bus) - Lutron power panels - Lutron QS devices

Quantum Specifications 369375e 2 04.02.2015 Regulatory Approvals culus Listed (Reference: UL File E42071) CSA Certified California Energy Commission Listed Seismic Certified (Test Method AC156. Reference OSHPD Preapproval OSP-0215-10) NOM certified models available Other certificates may apply Power Input voltage: 120 V~, normal/emergency feed 50/60 Hz 15 A Output: EcoSystem - 18 V- 250 ma per loop Processor - 24 V- 1 A per link Physical Design Enclosure: NEMA Type 1, IP-20 protection 16 U.S. gauge steel Weight: 45 Ib (20.4 kg) (with packaging) Seismic Certification Limits: S DS = 2.5 g, z/h = 1.0, I P = 1.5. Contact Lutron for details. Mounting Surface mount only Environment For indoor use only 32 ºF to 104 ºF (0 ºC to 40 ºC) Relative humidity less than 90% non-condensing

Quantum How to Build a Model Number Example QP2-2P8CSE - 120 Panel Type Number of Processors Number of Loops Accesory Device Voltage Available Model Numbers Contact Lutron for options not listed below. QP2-0P0CSE-120 (for rough-in use) QP2-1P0CSE-120 QP2-1P2CSE-120 QP2-1P4CSE-120 QP2-1P6CSE-120 QP2-1P8CSE-120 QP2-2P0CSE-120 QP2-2P2CSE-120 QP2-2P4CSE-120 QP2-2P6CSE-120 QP2-2P8CSE-120 369375e 3 04.02.2015 Panel Type QP2 = Quantum Light Management Hub Number of Processors 0P = 0 Quantum processors 1P = 1 Quantum processor 2P = 2 Quantum processors Number of Loops 0C = 0 EcoSystem loops 2C = 2 EcoSystem loops 4C = 4 EcoSystem loops 6C = 6 EcoSystem loops 8C = 8 EcoSystem loops Accessory Device SE = 5-port Unmanaged Ethernet Switch Voltage 120 = 120 V~

R R Quantum Dimensions Shown as in (mm) 369375e 4 04.02.2015 15.75 (400) Top View 2.5 (63.5) 15.75 (400) 12.75 (324) 5.81 (148) 0.15 (4) 31.5 (800) 26.5 (673) 31.5 (800) Left Side View Front View Right Side View Bottom View

Quantum 369375e 5 04.02.2015 Mounting and Conduit Entry Surface mount indoors. Panel generates heat. Mount only where temperature will be 32 F to 104 F (0 C to 40 C). This equipment is air-cooled. Do not block vents or warranty will be void. A minimum of 12 in (305 mm) of unobstructed space is required in front of and below the panel for ventilation. Water damages equipment. Mount in a location where the panel and processors will not get wet. Mount within 7 of true vertical. Digital ballast wiring can be Class 1 or IEC PELV / NECR Class 2; always keep Class 1 and Class 2 wiring separate, and follow all applicable local and national electric codes. Reinforce wall structure for weight and local codes. Panel Maximum BTUs/Hour Weight (without packaging) All models 220 45 Ib (20.4 kg) Mount panels so line (mains) voltage wiring is at least 6 ft (1.8 m) from sound or electric equipment and wiring. Dedicated feed Line voltage only Digital ballast loops NEC Class 1 or IEC PELV / NEC Class 2 only Ceiling IEC PELV / NEC Class 2 wiring only for control links and Ethernet connection Alternate ballast wiring entry Alternate ballast wiring entry Alternate IEC PELV / NEC Class 2 entry Alternate IEC PELV / NEC Class 2 entry Wall Alternate ballast wiring entry Alternate IEC PELV / NEC Class 2 entry Front View Side View

Quantum Panel Overview Line voltage input, normal/emergency feed 369375e 6 04.02.2015 Receptacle (for Lutron use only) Panel power switch IEC PELV / NEC Class 2 power supply board IEC PELV / NEC Class 2 wire trough Ballast wire trough Quantum bus supplies (4 modules, 2 loops per module maximum) Factory configured Quantum bus supply link Configurable links (power panel, Lutron QS, or Quantum bus supply) Processor LEDs 5-port unmanaged Ethernet switch Quantum processors (2 maximum)

Quantum Line Voltage Wiring 369375e 7 04.02.2015 GND N 120 V~ N/E Ground/Earth (green) Neutral (white) Hot/Live (black) Notes Line voltage must enter panel from top right of panel Run a dedicated 120 V~ normal/emergency feed Lutron recommends that no more than four Light Management Hubs are powered by a single derated 20 A circuit Run wiring so line (mains) Class 1 voltage is separate from IEC PELV / NEC Class 2 wiring

Quantum Quantum Inter-Processor Link Wiring Example of Inter-Processor Wiring: Riser Diagram 369375e 8 04.02.2015 Quantum Light Management Hub Floor Quantum Light Management Hub Floor Notes Ethernet switch The inter-processor wiring is considered IEC PELV / NEC Class 2; do not run in the same conduit as line (mains) voltage wiring. Wiring distance for any single link segment is 330 ft (100 m) max; use Lutron-provided Ethernet switches for longer distances. Processors cannot be more than 6 hops from the server. Processors communicate over the inter-processor link using multicast UDP; a dedicated network is recommended for the lighting control system. Processors within the panel are prewired to the Ethernet switch. Quantum Light Management Hub Floor Quantum Light Management Hub Unmanaged Ethernet switch Quantum Light Management Hub To additional Quantum Light Management Hubs Quantum server

Quantum Dedicated Quantum Bus Supply Link 369375e 9 04.02.2015 Notes EcoSystem bus may be wired in accordance with NEC Class 1 or IEC PELV / NEC Class 2 practices Sensors and Quantum bus supply contact closures must be wired IEC PELV / NEC Class 2 Dedicated Quantum bus supply link; prewired by Lutron to Quantum Bus Supply located in panel Note: If Quantum bus supply link is not required, this can be used as a configurable link. Power is not available from the Quantum panel on this link. An external power supply is required to power devices on this link. QP2-2P8CSE-120 shown EcoSystem Bus Diagram To additional ballasts and modules (up to 64 total) EcoSystem ballast 1 2 3 4 5 EcoSystem interface module Eco-10 or Hi-lume ballast* EcoSystem ballast EcoSystem ballast IR receiver Lighting remote Quantum bus supply (in panel) Occupant sensor (32 maximum per EcoSystem loop) EcoSystem keypad Daylight sensor (16 maximum per EcoSystem loop) * Does not count as one of the ballasts or modules on the EcoSystem bus

Quantum Quantum Bus Supply OPT Switches and LEDs 369375e 10 04.02.2015 H/L H/L N N ON1 2 3 4 5 OFF ON position position OPT Switches OPT switches are used to configure the Bus Supply. The tables below describe the options. To place an OPT switch in the OFF position, slide the switch to the left; away from the switch s number. Default is ON (next to the switch s number). E2 E2 E1 E1 E2 E2 E1 E1 Bus Supply Numbers: 1 2 3 4 Address Numbers: 1, 2 3, 4 5, 6 7, 8 OPT Switch Functions 1 Addressing 2 Set address for bus supply s loops 3 (2 loops per bus supply) 4 Green Loop (right side) 5 Manual override levels 6 Blue Loop (left side) Manual Override levels 7 8 Manual Override ON 1 2 3 Bus Supply 1 Addresses 1, 2 Lights stay at current level Lights stay at current level ON Manual override levels will be used ON ON 1 2 3 ON ON 1 2 3 4 5 ON 1 2 3ON 14 25 36 47 58 Bus Supply 2 Addresses 3, 4 Lights go to high level Lights go to high level ON 1 2 ON 3 4 5 ON ON ON 1 2 3 4 5 ON 1 2 ON 3 14 25 36 47 58 ON 1 2 ON 31 42 53ON 614 725 836 47 58 ON 1 2 3ON 14 25 36 47 58 ON ON 1 2 ON 3 4 5 ON 1 2 ON 31 42 5ON 3 614 725 836 47 58 Bus Supply 3 Addresses 5, 6 Lights go to low level Lights go to low level ON 1 2 3ON 14 25 36 47 58 ON 1 2 ON 31 42 5ON 3 614 725 836 47 58 ON 1 2 ON 31 42 53 64 75 8 Bus Supply 4 Addresses 7, 8 Lights go to Off Lights go to Off Lights will go to the level specified by the system H/L H/L N N ERR EMG BUS ERR EMG BUS ON 1 2 3 4 ERR EMG BUS ERR EMG BUS STAT V PWR Status LEDs LEDs on the Quantum Bus Supply indicate network status. The specific LEDs, color and flashing method is detailed below. STAT V PWR E2 E2 E1 E1 E2 E2 E1 E1 (Blue) (Green) LED Normal Operation Problem Indicator Probable Cause V~ PWR On Off No Mains power STAT Steady flash Off No Mains power or unit fault On Unit fault BUS Intermittent flash On Unit fault or Off ERR/EMG Off On Emergency contact closure is active Steady flash Miswire detected on corresponding bus

1 2 3 4 5 Quantum Quantum Bus Supply Wiring Line voltage in (prewired by Lutron) 369375e 11 04.02.2015 Processor link (prewired by Lutron; not visible in this view) DL7 DL8 E1 E2 E1 E2 EM C Emergency input (normally closed) E2 E1 E2 EcoSystem devices E1 Wire Gauge Max. Bus Length 12 AWG (4.0 mm 2 ) 2200 ft (670 m) 14 AWG (2.5 mm 2 ) 1400 ft (427 m) 16 AWG (1.5 mm 2 ) 900 ft (274 m) 18 AWG (1.0 mm 2 ) 570 ft (175 m) Notes E1 and E2 wires are not polarity sensitive. Hot/live, neutral, and ground wires are also connected to each lighting fixture; some may have an emergency feed. Wire-free topology. To additional EcoSystem devices If 15 V- +/- 1 V- is not present between E1 and E2, check the Quantum bus supply wiring. A short between E1 and E2 will cause the bus supply to stop providing voltage on the bus and will cause the ERR indicator to flash. Removing the short between E1 and E2 will allow the bus supply to operate properly. To wire the Quantum bus supply for IEC PELV / NEC Class 2, the Quantum bus supply wires must be separated from the mains wiring. Otherwise, the IEC PELV wiring must be classified as NEC Class 1.

Quantum Configurable Link Wiring: Power Panel Link 369375e 12 04.02.2015 Power panel Power panel Power panel DRAIN _ V+ COM 5 4 3 2 1 1 COM 2 N/C 3 4 D DRAIN 5 Sense line 1 COM 2 N/C 3 4 D DRAIN 5 Sense line 1 COM 2 N/C 3 4 D DRAIN 5 Sense line 4 3 3 4 Control wiring (1) 12 AWG (2.5 mm 2 ) 1: Common Link terminator (LT-1) Quantum Bus Supply link Configurable links Data link (1) shielded, twisted pair 22 AWG (1.0 mm 2 ) 3: 4: _ D: Drain wire in shield (keep away from ground and all electronics) IEC PELV / NEC Class 2 Terminal Wiring (2) 12 AWG (2.5 mm 2 ) Drain Data link: twisted, shielded pair 22 AWG (1.0 mm 2 ) 3: 4: _ Sense: 18 AWG (1.0 mm²) Link terminator (LT-1) Emergency/essential sense line (1) 18 AWG (1.0 mm²) 5: Sense line Sense line is used when there is a panel being supplied by an emergency/essential feed 1 2 3 4 D 5 C D Data A OK Power OK Data B OK Notes Power panel link must be daisy-chained (no T-taps). Maximum of 32 power panels per link. It is not necessary to have the Quantum panel at the end of the link. The sense wire (terminal 5) is used whenever there is a panel being supplied by an emergency/essential feed; see power panel instructions for details. Each low-voltage IEC PELV / NEC Class 2 terminal can accept only two 18 AWG (1.0 mm 2 ) wires. Two 12 AWG (2.5 mm 2 ) conductors will not fit. Connect as shown using appropriate wire connectors. Common 24VFW Drain Sense Link Link A B 1 2 3 4 D 5 C D SELECT CIRCUIT Comm Drain Total length of control link may be no more than 2000 ft (600 m). If -RPTR interface and GRX-CBL-46L cable are used, length may be up to 4000 ft (1200 m). GRX-CBL-46L IEC PELV / NEC Class 2 wiring cable is available from Lutron and contains two 12 AWG (2.5 mm 2 ) conductors for control power, one twisted, shielded pair of 22 AWG (1.0 mm 2 ) for data link, and one 18 AWG (1.0 mm 2 ) conductor for emergency (essential) sense line.

Quantum Configurable Link Wiring: GRAFIK Eye QS and Sivoia QS Shades DRAIN V+ COM 5 4 3 2 1 GRAFIK Eye QS Link (do not use the DRAIN terminal) GRAFIK Eye QS control unit 369375e 13 04.02.2015 QS wallstations 4 3 4 3 4 3 2 2 2 1 1 1 Sivoia QS Shade Link (do not use the DRAIN terminal) Sivoia QS shade Notes System communication uses IEC PELV / NEC Class 2 low-voltage wiring. Follow all local and national electrical codes when installing IEC PELV / NEC Class 2 wiring with line voltage/mains wiring. Each terminal accepts up to two 18 AWG (1.0 mm 2 ) wires. Total length of control link must not exceed 2000 ft (600 m); extend using up to 3 link repeaters [each adds 2000 ft (600 m)]. Make all connections in the control unit s wallbox. DRAIN _ V+ COM 5 4 3 2 1 Sivoia QS smart power supply panel 1 2 3 4 1 2 A B C Configurable links GRAFIK Eye QS control unit 1 2 3 4 5 6 L N Note: Wallstations are powered directly from the lighting management panel (not the GRAFIK Eye QS control unit) IEC PELV / NEC Data link: (1) twisted, Class 2 shielded pair 22 AWG (1.0 mm 2 ) Terminal 3: Wiring Drain 4: _ V+ and COM Wire Gauge (2) 12 AWG (2.5 mm 2 ) (2) 12 AWG (2.5 mm 2 ) IEC PELV / NEC Class 2 control wiring (2) 18 AWG (1.0 mm 2 ) 1: Common 2: 24 V- QS Link Max. Total Length 12 AWG (2.5 mm 2 ) 2000 ft (600 m) 16 AWG (1.5 mm 2 ) 800 ft (250 m) 18 AWG (1.0 mm 2 ) 500 ft (150 m) A Quantum QS link can have up to 512 switch legs (outputs) and 99 devices. The Quantum Light Management Hub provides 33 power draw units (PDUs) on the QS Link. For more information, see Power Draw Units on the QS Link (Lutron P/N 369405), at www.lutron.com/qs. Wiring can be T-tapped or daisy-chained. Wire sizes: - Two 12 AWG (2.5 mm 2 ) conductors for control power. - One twisted, shielded pair of 22 AWG (1.0 mm 2 ) for data link. - Cable is available from Lutron: GRX-CBL-46L. 4 3 2 1 C B A