TS2M-Bus Protocol Converter / User Manual

Similar documents
Interface Module XC Level Converter / User Manual

Interface Module XC Modbus Protocol Converter / User Manual

M-BUS Standard acc. EN AE.05:04.01: Protocol Specification

OMS Vol.2 Primary Elster Implementation

M-Bus-Logger Data Logger

Meter Bus. Intelligent Communication

COMMUNICATION M-BUS PROTOCOL CE4DMID0M (MBus meter)

COMMUNICATION M-BUS PROTOCOL PR 118

SF-586x: M-Bus Extension

GmbH, Stettiner Str. 38, D Paderborn

M-Bus protocol CALEC energy master

M-BUS PROTOCOL for ML 311

Technical Description. Wired M-Bus. Water Meters flowiq 2101/3100

UniMod Intelligent Communication for all Metering Application

M-Bus Pulse Collector Twin-Pulse Instruction Manual

EEM230-D-M. Energy meters. Electrical Energy Meter with integrated M-Bus interface

PADPULS2 M-BUS Pulse Input Modules

EM111-EM112 M-BUS COMMUNICATION PROTOCOL. Revision 4.0

GmbH, Stettiner Str. 38, D Paderborn. PadPuls M4L. Art.-No. IM002G: (Valid from M-Bus generation: $12)

GNM1D M-BUS COMMUNICATION PROTOCOL. Revision 0

3-phase energy meters with M-Bus interface

Singlephase Energy meter with M-Bus interface

FALCON PR6/PR7 Operating instructions M-Bus module for Elster water meter with Falcon register

GmbH, Stettiner Str. 38, D Paderborn. PadPuls M2. Art.No.: IM003G + IM003GB. (Valid from M-Bus generation: $40)

EEM230-D-M. Energy meters. Electrical Energy Meter with integrated M-Bus interface

SONOMETER 1100 Communication description MBus ID = 0x2F

GNM3D M-BUS COMMUNICATION PROTOCOL. Revision 1

jmbus User Guide Fraunhofer Institute for Solar Energy Systems ISE openmuc.org

Mounting instruction Gateway M-Bus Master AMB8466-M-GMM Release 1.2

0xc1 (Mass) 0xc2 (Flow) 0xc3 (Reserved) 0xc4 (BDE) 0xc5 (AMTRON X-50) 0xc6 (AMBILL) 0xc7 (TGR) 0xc8 (BDV) 0xc9 (DTF)

Assembly. Assembly. Connections Main circuit. Connections Control circuit. Insulation properties

Solenvis SL80 Pulse to M-Bus Converters

Operating Instructions RMx621

AB Axis Industries. Use

DRT-205C M-Bus Protocol V1.1

1 ABBREVIATIONS VERSION M-BUS PROTOCOL SUMMARY OF M-BUS DATA TYPES...15

BA00216R/09/EN/ MS Word

RelAir R2M PRO / HOME

SCYLAR INT 7. Communication description. Software Version 01

UniMod Ethernet. LAN-Modem. Bär Industrie-Elektronik GmbH Siemensstr. 3 D Fürth Germany

M-Bus Slaves for MULTICAL 601

M-BUS/MODBUS CONFIGURATION SOFTWARE FOR GINEERS MMCR-64

FLOW 38 v8.x. M-Bus communication protocol specification

SHARKY BR773. Communication Description. Software Version 28

WIRELESS RECEIVER WRM-TS. Rev. 1.0c

E65C CU-E20, E22. User Manual. Communication Industrial and Commercial

Energy meters Single phase electrical energy meters WM1-6 / WM1M6

The accessories described in this manual are of the highest quality, carefully designed and built in order to ensure excellent performance.

Modbus Module. Data sheet. Communication module for MULTICAL 403 and MULTICAL 603

Jiaxing Eastron Electronic Instruments Co.,Ltd. Tel: Fax:

A2000 Multifunctional Power Meter Profibus Interface

Product Manual for the Mini Industry Meter MIZ Installation I Device description I Operation

M-Bus Master Manual. M-Bus Master. Manual. Version 2.0 1/10

AMBUS IS M-Bus pulse collector

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

Supercom 636. Manual Radio Modem. Issue: Rev Document: Manual Supercom 636 R+W rev

Modbus Module. Data sheet. Communication module for MULTICAL 403 and MULTICAL 603

Network node WTT56.. A6V _en--_c Building Technologies

CEM M-RS485 INSTRUCTION MANUAL (M014B A)

SINGLE PHASE AMR ELECTRONIC METER MEM Electric meter has the following functions: Technical information

M-Bus Central Unit OZW10

A2000 Multifunctional Power Meter

CAN-Bridge. CAN Communications Module for CAN 2.0 A/B, CAN Layer AA01. Manual. Version 1/ from HW 1 & FW 1.00

Operating instructions. ProcessLine analogue module AC / / 2012

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

DLMS Implementation Guide

EQUOBOX TOOLKIT LITE User Guide

Smart Energy Meter. Benefits and Main Features. User Manual Revision English OB (100)A

Citect for Windows, Version 5.xx, 6.xx. M-Bus driver, User information

Baer Meter2SCADA. Meter2SCADA

PAC BI-DP BIM and 8701-CA-BI Carrier

B Interface description 12.01/

COUNTIS E05. Single-phase energy meter Direct - 40 A M-BUS. Instruction manual. en/countis-e0x

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

Type 6150 AS-Interface Module. Type 3372 Electropneumatic Actuator with AS-interface module. Mounting and Operating Instructions EB 6150 EN

System CPX-E. IO-Link master module CPX-E-4IOL- Description. Protocol IO-Link. Function Parameterisation [ ]

EY-CM 721: Communication module with EIA-232 and EIA-485 interfaces, modu721

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

Controls Division. Mounting. Mounting Terminal connections main circuit. Terminal connections control circuit. Insulation characteristics

AEW36.2. Pulse Adapter. Building Technologies. Siemeca AMR

M-Bus Central Unit. Use

TR600 with RS485 Appendix 1

Communication description Page 2 29 CALEC ST II KNX TP1

DEIF A/S. Description of options. Option H4 Serial comm. CAT CCM communication Multi-line 2 version 2. Description of option Functional description

IFC 100 Supplementary instructions

BNI IOL K023 BNI IOL K023. User s Guide

GFK-2415A March Type of sensor connection

NXT4 Three phase meter for commercial, industrial and advanced residential applications

EY-CM 721: Communication module with EIA-232 and EIA-485 interfaces, modu721

Electrical Energy Meter with integrated Serial Modbus interface

User Manual V1.1. SDM120-Modbus(mV) Single-Phase Multifunction DIN rail Meter

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

Du line. Dupline Field- and Installationbus Dupline Ethernet Modbus/TCP Gateway Type G G Type Selection

PowerLogic ION6200 Serial Communications Protocol and ION / Modbus Register Map

MIC-2 Multi-instrument DATA SHEET

USER MANUAL 2012 V1.1

Elotech Standard Protocol. for Single R8200 SC

User Manual V2.6. SDM120-Modbus. Single-Phase Multifunction DIN rail Meter

RNN5-STD NETWORK NODE FOR AMR SYTEMS

CPU. Switch 1 Switch 2

Transcription:

Page 1 from 10 General The Protocol Converter TS2M-Bus is designed for use with the EMH LZQJ-XC and DMTZ-XC meters. The module is equipped with one RS485 interface (to the meter) and one M-Bus passive interface (to the data acquisition). The module can be connected easily with the meter. It can be mounted or exchanged during operation (without breaking approval seal). An integrated M- Bus interface (Protocol Converter to DIN EN 13757-3) provides a simple means of connecting multienergy meters. This makes multi-energy applications an affordable proposition for domestic use. Due to the communication, the modules are suitable for a lot of control centres. Safety Notes Compatible Meters LZQJ-XC (special meter for industrial applications): - Standard meter for direct connection - Transformer connection version Cl. B (Cl. 1) - Precision meter Cl. C (Cl. 0.5S) - Precision meter Cl. 0,2S DMTZ-XC (residential meter) Functions M-Bus interface (2 wires, passive) for bi-directional communications with the meter reading software; Alternative: BFC-Bus (BAER Field Control, 56VDC); Transmission protocol: M-Bus (DIN EN 13757-3:2013-08); Serial RS485 interface for the transfer data between the meter and the module (service data list / table TS); termination for RS485 (R = 120Ω) is not allowed! Protocol converter for meter data into M-Bus-Format (non transparent data readout); Power supply via M-Bus interface; Can be connected during the meter operation; The owner of the modules is responsible that all persons engaged on work with the modules: Are competent and qualified in accordance with national regulations (see ISSA Guideline for Assessing the Competence of Electrically Skilled Persons ). Have read and understood the relevant sections of the user manual. Strictly observe the safety regulations (according to the following section) and the instructions in the individual chapters. The owner of the modules is also responsible for: The protection of persons. The prevention of material damage. The training of personnel. The following safety regulations must be observed at all times: Devices which have fallen down should not be installed, even if no damage is apparent, and should be returned for testing to an authorised service centre (internal damage possible). Modules must never be cleaned with running water or high pressure devices. Water can cause short-circuits or damage electrical components.

Page 2 from 10 Installation Hints Work on electrical installations and equipment may only be performed by adequately trained qualified and in conformity with the applicable national rules and regulations. Strictly observe the safety regulations! The modules can be connected to the RS485 interface during the meter operation. LED Displays Two LED s display the current operating status of the module and give information about the data transfer: LED Function Description BFC Error Power Bus Function Control Error Status and communication via M-Bus interface: LED signals, that the module is supplied with power (M-Bus) LED goes off during transmit data via M-Bus interface Communication error (RS485 interface to meter), LED flashes in 3 sec. Cycle

Page 3 from 10 Communication (M-Bus, Protocol Converter) The M-Bus interface is conforming to DIN EN 13757-3:2013-08. Fixed baud rate from the external RS485 interface (see EMH COMBI-TOOL-Software: communication interfaces, set please the data transmission at a fixed baud rate without baud rate changeover), data format: 8E1. For configuration purposes of the service table TS please contact the meter manufacturer or operators. Parameterisation of the Meter (EMH COMBI-TOOL-Software) At the first read all data from the meter (via optical IR interface): Baud Rate The TS2M-Bus Protocol Converter uses the same baud rate like the communication interface at the meter. For setting use please the EMH COMBI-TOOL-Software: Menu Meter Interfaces External interface: For correct working set please a fixed bad rate (e.g. 9600 baud). If you use the baud rate changeover according to mode C: the communication is possible with 300 baud only. For the addressing set the value optionally or ignore. Note: In many M-Bus systems is the standard baud rate 2400 baud.

Page 4 from 10 Service Data List / Table TS and M-Bus-Address For setting the meter data list use menu Lists Reading lists Service Table TS: Note: The TS2M-Bus module uses for ID-Addresses the OBIS Register 0.0.0 (secondary address) and 0.0.1 (primary address) in the service data list TS. In this example we use the identification number 1 (OBIS 0.0.1) for M-Bus primary address: Menu Meter Meter ID OBIS Register 0.0.1, e.g. value 123 (:= 00000123): Standards for M-Bus addresses: Primary address: OBIS Register 0.0.1 (Identification 1), range 0 to 250, default := 1 Secondary address: OBIS Register 0.0.0 (device number / fabrication number), range 0 to 99999999, default := 0 For determining the address it is possible to use the wildcard searching procedure (answer E5 Hex ).

Page 5 from 10 Accepting the Meter Data (OBIS-Registers) The TS2M-Bus Protocol Converter reads the service data list / table (TS) from the meter periodically (interval between two readings: ca. 1 second) and creates an internal table. The OBIS coded values from the meter will be convert to the M-Bus data. This version of the implementation supports following OBIS-Registers: Energy: Counter values for active, reactive and apparent energy (OBIS-Registers 1.8.x, 2.8.x, 3.8.x, 4.8.x, 5.8.x, 6.8.x, 7.8.x, 8.8.x, 9.8.x and 10.8.x). Power: Instantaneous values (average) for active and reactive power, voltage, current and line frequency (OBIS-Registers 1.25 at seq., 3.25 at seq., 11.25 at seq., 12.25 at seq. and 14.25); Last average value for active and reactive power (OBIS-Registers 1.5.t, 2.5.t, 3.5.t and 4.5.t). Possible OBIS-Registers in the service data list / table TS: OBIS-Register Description 0.0.0 Identification 0 (device address / meter number): secondary address 0.0.1 Identification 1: primary address; possible range: 0 to 250 1.5.t Last average 1 value active power, import* 21/41/61.5.t Last average 1 phase 1/2/3* 2.5.t Last average 1 value active power, export* 22/42/62.5.t Last average 1 phase 1/2/3* 3.5.t Last average 1 value reactive power, import* 23/43/63.5.t Last average 1 phase 1/2/3* 4.5.t Last average 1 value reactive power, export* 24/44/64.5.t Last average 1 phase 1/2/3* 1.8.t*s 2.8.t*s 3.8.t*s 4.8.t*s 5.8.t*s 6.8.t*s 7.8.t*s 8.8.t*s 9.8.t*s 10.8.t*s Counter value active energy, import Counter value active energy, export Counter value reactive energy, import Counter value reactive energy, export Counter value reactive energy, Q1 Counter value reactive energy, Q2 Counter value reactive energy, Q3 Counter value reactive energy, Q4 Counter value apparent energy, import Counter value apparent energy, export 1.25 Instantaneous value active power, cumulative 3.25 Instantaneous value reactive power, cumulative 11.25 Instantaneous value current, cumulative 12.25 Instantaneous value voltage, cumulative 14.25 Instantaneous value line frequency 21/41/61.25 Instantaneous value active power, phase 1/2/3 23/43/63.25 Instantaneous value reactive power, phase 1/2/3 31/51/71.25 Instantaneous value current, phase 1/2/3 32/52/72.25 Instantaneous value voltage, phase 1/2/3 t = tariff (0..8), s = stored values (0..99)

Page 6 from 10 Other OBIS-Registers will not be stored and cannot be transmitted. *: possible since firmware version 5 Output of the Meter Values via M-Bus The OBIS coded values from the meter will be convert to the M-Bus data (DIFs/VIFs: Data Identification Fields/Value Identification Fields according to DIN EN 13757-3:2013-08 without manufacturer specific extensions). Data field coding: 32 Bit Integer only (data field := 0100 Binary ), type B with the sign. Telegram format: variable data respond. Used telegram formats (examples): Master: SND_NKE (Send Link Reset) Hex (Acknowledge) Master: SND_UD (CI-Field 52 Hex for selection the secondary address; request via address FD Hex ) Hex (Acknowledge) Master: REQ_UD2 (Request User Data Class 2) Answer: RSP_UD (Respond User Data) Further specifications: The following definitions shall also apply for the selection of a new secondary address (SND_UD): - the manufacturer code (15 Hex A8 Hex for EMH ) will be evaluated, wildcard (FF Hex FF Hex ) is possible; - the version byte (Ver) will be ignored: all bytes are possible (e.g.: FF Hex ); - the medium byte (02 Hex for electricity) will be evaluated, wildcard (FF Hex ) is possible; Data encryption is not allowed. Max. telegram length: 252 bytes (max. ca. 30 values). Support only for mode 1 (CI-Field): the least significant byte (LSB) of a multibyte record is transmitted first. Status byte: only bit 4 ( temporary error ) is used: communication error between the modules and the meter. Implementation of one FCB-Bit (Frame Count Bit) only (use either the primary or secondary address).

Page 7 from 10 Structure of a Data Telegram (RSP_UD) Name No. of bytes Start 1 68 Value (hex) Description L 1 LL Length of the telegram L 1 LL Length of the telegram Start 1 68 C 1 08 Control field: RSP_UD A 1 Padr Primary address (OBIS-Register 0.0.1) CI 1 72 Control information field: variable data respond Identification no. 4 Sadr Secondary address (OBIS-Register 0.0.0) Manufacturer code 2 A8 15 Code for EMH : 15 A8 Version of device 1 Ver Version of the interface module Medium 1 02 Electricity Access No. 1 AccNo Status 1 Stat Status Signature 2 00 00 Not used User data n... Access number is increased by one after each respond user data (RSP_UD) from the slave Check sum 1 xx Arithmetical sum of the data mentioned above Stop 1 16 Examples for readout with primary address: Master: 10 40 01 41 16 (primary address: 1 / SND_NKE: Send Link Reset) Master: 10 40 FE 3E 16 (primary address: wildcard 254 = FE Hex ) Master: 10 40 7B BB 16 (primary address: 123 = 7B Hex ) Master: 10 7B 7B F6 16 (REQ_UD2: Request User Data with primary address: 123 = 7B Hex ) Answer: 68 0F 0F 68 08 7B 72 87 98 16 04 A8 15 00 02 00 10 00 00 FD 16 (empty message) Master: 10 5B 7B D6 16 (REQ_UD2: Request User Data with primary address: 123 = 7B Hex ) Answer: 68 EA EA 68 08 7B 72 87 98 16 04 A8 15 00 02 01 00 00 00 04 03 C9 16 00 00 C4 05 03 6D 13 00 00 84 10 03 C2 10 00 00 C4 15 03 A8 0E 00 00 84 20 03 06 06 00 00 C4 25 03 C5 04 00 00 04 FB 82 73 90 03 00 00 C4 05 FB 82 73 06 02 00 00 84 10 FB 82 73 4A 02 00 00 C4 15 FB 82 73 54 01 00 00 84 20 FB 82 73 46 01 00 00 C4 25 FB 82 73 B1 00 00 00 04 2B 0C 00 00 00 04 AB FC 01 00 00 00 00 04 AB FC 02 00 00 00 00 04 AB FC 03 0C 00 00 00 04 FB 14 05 00 00 00 04 FB 94 FC 01 00 00 00 00 04 FB 94 FC 02 00 00 00 00 04 FB 94 FC 03 05 00 00 00 04 FD D8 FC 01 10 00 00 00 04 FD D8 FC 02 0E 00 00 00 04 FD D8 FC 03 13 03 00 00 04 FD C7 FC 01 3E 00 00 00 04 FD C7 FC 02 38 00 00 00 04 FD C7 FC 03 30 59 00 00 04 FB 2D 87 13 00 00 0C 16 (RSP_UD: Respond User Data)

Page 8 from 10 Examples for readout with secondary address: Master: 68 0B 0B 68 53 FD 52 00 00 00 00 FF FF FF FF 9E 16 (selection with the secondary address: 00 00 00 00) Master: 68 0B 0B 68 53 FD 52 FF FF FF FF FF FF FF FF 9A 16 (selection with the secondary address: wildcard FF FF FF FF Hex ) Master: 68 0B 0B 68 53 FD 52 87 98 16 04 FF FF FF FF D7 16 (selection with the secondary address: 04 16 98 87 Hex ) Master: 10 7B FD 78 16 (REQ_UD2: Request User Data) Answer: 68 EA EA 68 08 7B 72 87 98 16 04 A8 15 00 02 02 00 00 00 04 03 77 15 00 00 C4 05 03 6D 13 00 00 84 10 03 E6 0F 00 00 C4 15 03 A8 0E 00 00 84 20 03 90 05 00 00 C4 25 03 C5 04 00 00 04 FB 82 73 F5 02 00 00 C4 05 FB 82 73 06 02 00 00 84 10 FB 82 73 E5 01 00 00 C4 15 FB 82 73 54 01 00 00 84 20 FB 82 73 0F 01 00 00 C4 25 FB 82 73 B1 00 00 00 04 2B 0C 00 00 00 04 AB FC 01 00 00 00 00 04 AB FC 02 00 00 00 00 04 AB FC 03 0C 00 00 00 04 FB 14 05 00 00 00 04 FB 94 FC 01 00 00 00 00 04 FB 94 FC 02 00 00 00 00 04 FB 94 FC 03 05 00 00 00 04 FD D8 FC 01 0C 00 00 00 04 FD D8 FC 02 08 00 00 00 04 FD D8 FC 03 08 03 00 00 04 FD C7 FC 01 3F 00 00 00 04 FD C7 FC 02 38 00 00 00 04 FD C7 FC 03 49 59 00 00 04 FB 2D 87 13 00 00 32 16 (RSP_UD: Respond User Data) Master: 10 40 FD 3D 16 (deselecting of the secondary address allocation) Terminal Assignment Terminal Description A+ RS485* interface to meter (terminal: 24/B) B RS485* interface to meter (terminal: 23/A) a M-Bus passive (+) b M-Bus passive ( ) a M-Bus passive (+) b M-Bus passive ( ) Terminals with the same notation are internal linked. * Note: termination for RS485 (R = 120Ω) is not allowed! The valid terminal connection is always displayed at the terminal block of the device

Page 9 from 10 Technical Data Housing: Control housing for top hat installation (DIN 43880) Degree of protection: IP20 (according to IEC 60529) Protection class: 2 Temperature range: Relative humanity: -25 C to +55 C (operational) -40 C to +80 C (storage temperature) 0..95%, non-condensing Dimensions: Ca. 35mm x 90mm x 62mm (W x H x D) Nominal voltage: M-Bus load: Battery: Power supply via M-Bus interface, max. voltage 56VDC 4,5mA (3 M-Bus loads), max. voltage: 56VDC None LED displays: 2 LEDs: (green) BFC: power / transmit data via M-Bus (red) Error: communication error with meter Meter interface: M-Bus interface: Baud rate: Transmission protocol: RS 485-2wires; termination for RS485 (R = 120Ω) is not allowed! Data readout: internal service data list / table TS M-Bus (2 wires, passive) according to DIN EN 13757-2 (Physical Layer) Alternative: BFC-Bus (BAER Field Control, 56VDC) 300 to 9600 baud (fixed baud rate), 8E1; default: 2400 baud M-Bus according to DIN EN 13757-3:2013-08 (Application Layer) with fixed baud rate Order number: #13047 Accessories: M-Bus Master / Repeater / Mini-Master AMR-Software: SIGLON / Field Control Center: Meter2SCADA Dimensions

Page 10 from 10 Baer Industrie-Elektronik GmbH Siemensstr. 3 D-90766 Fürth Germany Phone: +49 (0)911 970590 Fax: +49 (0)911 9705950 Internet: www.baer-gmbh.com Subject to change without notice! Version 5.05