Speaking Station LV30

Similar documents
Emergency power supply NV2.1-12iaE

Power supply unit NG3-16ib

PI-EX-ME-2NAM/COC-24VDC

PHOENIX CONTACT - 12/2007

PI-EX-ME-2NAM/COC-120VAC

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC

QUINT-BUFFER/24DC/24DC/40

Explosion proof UL certified VoIP telephone. FernTel IP Z2 UL. Tabletop unit. Manual FHF BA /12

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

Configurable Network Paging Console. Product Instructions. Model: X-NPMI

Isolating repeater IRU 420

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

Redundancy Module QUINT-DIODE/40

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

PHOENIX CONTACT - 07/2006

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

5 Fieldbus Technology

Operating Instructions

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

PHOENIX CONTACT - 05/2007

PHOENIX CONTACT - 01/2008

SolConeX Wall-Mounted Socket, 16 A

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Product Information. DCM Standard indoor stations TK IS A 514 A.. TK IS A 514 AD.. (Design)

Inductive sensor with analog output BI15-M30-LI-EXI

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

PHOENIX CONTACT - 01/2007

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Inductive sensor NI3-EG08K-Y1-H1341

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

TRIO-DIODE/12-24DC/2X10/1X20

PHOENIX CONTACT - 02/2008

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

Loop-powered Transmitter for Thermocouple Type K (NiCr-Ni)

Safety instructions Overvoltage protection B81-35

Digital Explosion-proof Intercom Stations DX/DXE 0x5 Series

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

Operating instructions. Switching amplifier DN0210 DN / / 2015

Inductive sensor BI1.5-EG08-Y1-H1341

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 5 mm

PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL

M E M O R A N D U M I.S.

WG 20. The WG 20 achieves an extraordinarily. accuracy for hazardous-area. applications.

Zener Barriers Bulletin 937Z

IB IL 120 DI 1. Function. INTERBUS Inline Terminal With One Digital Input in the 120 V AC Voltage Area. Data Sheet 5764B

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Intrinsically Safe Telephone (EEx ia II)

Product manual plug, sockets and coupler 16 A.- Z0251

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

OFFICE UPS MULTI-DEVICE PROTECTION UPS 500S/600S/750S

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5

Technical Data. General specifications. Output type Rated operating distance s n 8 mm

INTRINSICALLY SAFE Ex ia PSU TYPE AC36W

CMC III Temperature/Humidity Sensor

MACX MCR-EX-SD LP(-SP)

Safety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications.

Operating instructions. Speed monitor D / / 2014

Manual Mouse Module CHALLENGER Mi-PS2 / Mi-PS2-B

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

Inductive sensor BI1.5-EG08-Y1-H1341

ETHOS Auto Ranging Digital Multimeter

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

D1093S INSTRUCTION MANUAL. D SIL 3 Relay Output Module with Line and Load diagnostics. DIN-Rail Model D1093S

CMC III Universal Sensor

Magnetic Field Sensor for pneumatic cylinders BIM-INT-Y1X-H1141

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.

BS 217 DUAL CHANNEL MASTER STATION USER MANUAL

Technical Data. Dimensions

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

MINI MCR-SL-PT100-UI(-SP)(-NC)

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

TEPI11 P/I signal converter

System Components Surge Arrester HAW 261 and HAW 262

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

MACX MCR-EX-SL-NAM-R(-SP)

Inductive Angle Sensor With Analog Output RI360P1-DSU35TC-ELI-EXI

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X-H1341

FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex)

DCS Infrared Transmitter. User Manual. Digital Conference System. Danish Interpretation Systems

EX- Documentation VA 450 / VA 452. thermal mass flow sensor

Overview of types. Technical data

Thank you for your purchase USER MANUAL

Interface and Supply module. IPC 3x0i / PSC 3x0i

Functional data Factory settings Variable Setting Torque Inhibiting torque

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Signal conditioning instruments for level switches. Conductive VEGATOR 256C VEGATOR 532 VEGATOR 631. Product Information

Druck DPI 620 advanced modular calibrator

Operating Instructions

SUBCON-PLUS-PROFIB...

Transcription:

Speaking Station LV30 Ordering data Designation Type Item no. Speaking station with cable entries LV 30 300 0 AX Speaking station with plug connectors (socket / socket) Speaking station with plug connectors (socket / plug) LV 30 LV 30 300 AX 300 AX Cost-efficient speaking station with loudspeakers Clearly audible, reliable intercommunication and signalling Emergency operation (intercommunication) by means of batteries integrated into each LV30 in the event of a power failure Rechargeable NiCd battery (8. V / 80 mah) Visual indication of supply voltage Connection of the wires: protected against polarity reversal Connection of the WL-wires: protected against polarity reversal Protection type: I M EEx ia Ι Configuration The electronic equipment of the speaking station realised in SMD technology is incorporated into a steel sheet enclosure of protection degree IP and fixed to the swivelling front cover of the LV30 enclosure. The electronic equipment consists of two module housings encapsulated in sealing compound. The bottom housing contains the battery charging circuit, the loudspeaker and microphone amplifiers. The top housing accommodates the rechargeable NiCd battery pack. This integrated battery on the one hand enables a high volume while consuming only an inferior amount of power from the system line, and, on the other hand, it enables the temporary emergency operation of the speaking station after shutdown of the supply voltage due to e.g. an increased methane content or a supply voltage failure. (If the device is supplied through a power supply circuit of category I M, protection type EEx ib I or of category I M, protection type EEx ia I within a correspondingly approved intrinsically safe system, the user will be responsible for this power supply circuit to be shut down in the event of an explosive atmosphere (increased methane content), and thus for the DC s (DC, DC) of the device to be de-energized. The circuits still kept operable, which are supplied with power through the internal battery of the device, conform to category I M, protection type EEx ia I.) Copyright FHF Bergbautechnik GmbH & Co. KG 08.00 Subject to technical modifications without notice. Page

The two LV30 loudspeakers are integrated into the housing on the left and right side. The buttons for intercommunication, control room alert and signalling as well as the integrated microphone are flush mounted. In addition, these talk, control room alert and signalling buttons are colour-marked (talk button = blue; control room alert button = yellow; signal button = red). Through two PG6 cable entries (optionally: two 6-pole plug connectors, according to the design type socket / socket or socket / plug connector) the connecting cable is led into the interior of the enclosure and connected to the related terminals. Function description When used for instance in a L intercom system between the L-H main station and the L-E end unit, the speaking stations LV30 will be integrated into the connecting line. The LV30 features a built-in microphone which is activated when the talk button is pressed. The subsequently installed microphone amplifier amplifies the signals recorded via the microphone up to such an extent that afterwards it is possible to inject them at a nominal level of -6 db into the WL (LF)-wire pair of the connecting line. The microphone sensitivity can be varied by means of an internal potentiometer. In as-supplied condition, this potentiometer is set to a centre position. All further LV30 speaking stations linked to the connecting line emit these signals through their built-in loudspeakers. In that case, the nominal level of the volume will be approx. 0 db(a) at m distance. An internal potentiometer allows to adjust the volume. In as-supplied condition, this potentiometer is set to max. volume. In addition to the talk button, the speaking station LV30 is equipped with a signal button and a control room alert button. When the signal button is pressed, a signal tone of 980 Hz (-6dB) will be emitted, when the control room alert button is pressed, a control room alert tone of 0 Hz (- 6dB) is emitted onto the WL (LF)-wire pair. While the signal tone serves for signalling purposes, the control room alert tone can be used as a calling tone to call e.g. a 00-switchboard by activating this button in a previously defined sequence. As a function check, the signal tone will also be shortly emitted (ca. 00ms) through the loudspeakers of the emitting station after the signal button (980 Hz) has been pressed. The output stage for activating the LV30 loudspeakers is controlled via a voice detector. This device features a transformer decoupled to the WL (LF)-wire pair of the connecting line. In the case of AC levels with a value of > 60 mv on the WL (LF)-wire pair of the connecting line, the voice detector responds and activates the LV30 output amplifiers. With signal levels < 0 mv, the voice detector is deactivated and shuts down the output amplifier with an OFF delay (OFF delay ca. s). The battery of the speaking station is charged through an internal switching transformer with constant energy which is drawn from the supply voltage energizing the input terminals (8 to V). The front cover of the speaking station LV30 is equipped with a built-in visual monitoring indicator (red LED). If there is a supply voltage on the DCwires of the connecting line, the indicator light will be on (red LED). Copyright FHF Bergbautechnik GmbH & Co. KG 08.00 Subject to technical modifications without notice. Page

Block diagram LV30 NF NF NF LF output voice detector amplifier NF volume microphone sensitivity control room alert Gz talk button Gs signal button switching transformer DC battery charge control battery control battery 8, V 70 mah DC Wiring diagram NF NF L- system line L- system line NF LV 30 electronics NF DC DC Copyright FHF Bergbautechnik GmbH & Co. KG 08.00 Subject to technical modifications without notice. Page 3

Dimension drawing LV30 LV30 with cable entries LV30 with plug connectors Technical data LV30 Designation Type Speaking station LV30 Supply circuit (wire pair) Voltage U i 3 V DC Effective internal capacity C i negligible Effective internal self-inductance L i negligible Nominal ratings: Connecting terminals for the wires of the connecting line Terminal DC + V DC up to 8 V DC Terminal 0 V DC Connecting terminals for the wires of the connecting line (with, if existing) Connection + V DC up to 8 V DC Connection 0 V DC Note: The of the WL-wires is configured so as to offer polarity reversal protection. An interchange of terminal DC with terminal or of with is permitted. LF circuit (WL(LF)-wire pair) Voltage U o Amperage I o Nominal voltage 6 V 6 ma 38 mv at 600 Ω (-6 dbm) Connecting terminals for the WL-wires of the connecting line Terminal NF Terminal NF Connections for the WL-wires of the connecting line (with, if existing) Connection Connection Note: The of the WL-wires is configured so as to offer polarity reversal protection. An interchange of terminal NF with terminal NF or of with is permitted. Copyright FHF Bergbautechnik GmbH & Co. KG 08.00 Subject to technical modifications without notice. Page

Technical data LV30 Transmission level Frequencies Voice Signalling tone Control room alert tone Voice detector Voice detector activated Voice detector deactivated OFF delay for the output amplifier of ca. Battery NiCd battery Power consumption Control elements Buttons for: Visual indicators supply monitoring (red LED) -6 dbm (± db) at 600 W on the WL(LF)-wire pair in the case of intercom, signal and control room alert 300 Hz up to 0 khz 980 Hz 0 Hz Signal voltage 60 mv on the WL(LF)-wire pair of the connecting line Signal voltage < 0 mv on the WL(LF)-wire pair of the connecting line sec 8. V / 80 mah < 30 µa in quiescent condition via battery ca. 300 ma with loudspeaker activated intercom, signal tone and control room alert tone The indicator light will be on, if there is a supply voltage on the wires of the connecting line. Enclosure Steel sheet, colour: orange Enclosure protection degree IP acc. to IEC 9 Cable entries x PG6 Optional s x 6-pole (socket/socket) or (socket/plug) Operating position at choice Operating conditions Preferrably within firedamp mine environments Operating mode 00 % ED Temperature range - operation - storage - transport 0 C to + 0 C - C to + 0 C - C to + 0 C Dimensions See dimension drawing Weight Storage Test and approval - type of protection - approval no. ca. 8. kg The batty integrated into the speaking stations LV30 is subject to self-discharge. After extended storage periods the battery should be recharged to ensure that the speaking station LV30 will immediately be operable after installation. I M EEx ia I DMT 0 ATEX E 097 Marking The nameplate is marked as follows: Company Type FHF Bergbautechnik D- Velbert LV30 I M EEx ia I DMT 0 ATEX E 097 08 0 T a + 0 C F. No... test...(initials, month/year) Copyright FHF Bergbautechnik GmbH & Co. KG 08.00 Subject to technical modifications without notice. Page

Warning and Safety Advice The apparatus is a flameproof device of safety-class group I. Please pay particular attention to the following warning and safety advice: The apparatus is to be connected and installed in accordance with the specified installation instructions by qualified personnel, taking into account the protection type indicated. If the device is supplied with power through an appropriately approved intrinsically safe power supply circuit of category I M, protection type EEx ib I or category I M, protection type EEx ia I, the user will be responsible for this power supply circuit to be shut down in the event of an explosive atmosphere (increased methane content) and thus for the and battery charging s to be de-energized. The circuits still kept operable which are supplied with power by the internal battery of the device conform to category I M, protection type EEx ia I. The inter with other electric equipment must be separately certified. The device may only be connected and operated with the specified voltage. The polarity specifications are to be observed. Replace faulty components only by the appropriate genuine spare parts. Make sure the housing is not damaged. Do not operate faulty devices, shut them off immediately. If the device is operated in an industrial installation, the rules for the prevention of accidents for electrical installations and equipment of the association of the industrial employer s social insurance against occupational accidents shall be observed. The device may only be operated under the specified ambient conditions. Unfavourable ambient conditions may damage the appliance, possibly jeopardising the user s life as a result. Unfavourable ambient conditions may be: moisture, dust (observe type of protection) air humidity too high (> 7% rel., condensing) inflammable gases, vapours, solvents not covered by the protection class of the device. ambient temperatures too high (> + 0 C) ambient temperatures too low (< 0 C). The ambient temperature specified for the device may not be exceeded or failed to be reached during operation, storage and transport. Only use the cable glands/entries specified by the manufacturer. The extension and the installation of further parts is not permitted. Repair work may only be realised by the manufacturer or by a person authorized by the manufacturer. Subsequently, a new routine test for the device must be carried out. Make sure the device is protected against damage during transport, storage and when not in use. Disconnect the battery to prevent its premature discharge. Devices that have been operated outside intrinsically safe installations and, in particular, have been supplied with power by a non-intrinsically safe power supply may not be operated in explosive areas due to possible previous damage. Preferably, the device is mounted horizontally, with the cable glands and plug connectors facing downwards at the bottom side. When mounting the device, it is to be ensured that the device will not be used as climbing aid and thus be damaged. If required, additional measures must be taken to protect the device against falling objects. It must be ensured that the apparatus allows easy access and operation. It must be ensured during the mounting that the substructure features an adequate carrying capacity. Copyright FHF Bergbautechnik GmbH & Co. KG 08.00 Subject to technical modifications without notice. Page 6

Warning and Safety Advice Any faulty lines on the devices shall be replaced. Attention: Disregarding the above points will nullify the explosion protection. The device then represents a danger to the life of the operator and may cause a hazardous atmosphere to explode. The device features a high sound level. Do not go too near to the activated loudspeaker in order to avoid hearing impairment. FHF Bergbautechnik GmbH & Co. KG Eintrachtstr. 9 D- Velbert Tel:(00) 70 0 Fax: (00) 70-366 Mail: info@fhf-bt.de URL :www.fhf-bt.de Copyright FHF Bergbautechnik GmbH & Co. KG 08.00 Subject to technical modifications without notice. Page 7