Badger Meter Europa GmbH. INSTRUCTION MANUAL Deluxe LCD display for the MN series. September Version MN-Deluxe LCD display-09/01-e

Similar documents
Intrinsically safe batch controller Batching Master 110i

Speaker Selectors Models SSW-L4 EX and SSW-L6 EX. User Manual. SSW-L4 EX (bottom) and SSW-L6 EX (top)

Models VSP12824V & VSP12860V

Badger Meter Europa GmbH. LMS Baby System. Oil management system USER MANUAL. May Firmware v v3.9. LMS_Baby System_BA_02_1005

Installation Manual. Flow Max 110

Sonic Ruptor 400. User Manual

MOD. KBC HEAD KONTAX BATCH CONTROLLER

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

ODYS Xound Mini - 1 -

Model 8702 DP-CALC Micromanometer

MODEL 245 / 345 High Range

Q09 Display Owner s Manual

UÊ, Ê* - 1 Ê Ê Ê " /",Ê

MODEL 245 / 345 DigiComp

VELOCICALC Air Velocity Meter

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

EXTENDER DIGITAL-ANALOG AUDIO. pulseaudio1.com vanco1.com DIGITAL AND ANALOG AUDIO EXTENSION OVER A SINGLE CAT5E/6 CABLE

POWER SERIES Plus Watt-VAR / Watt-Power Factor Digital Switchboard Meter User s Manual IM2492WVPF-1

VDI Pro Voltage & Dry Contact Interface Installation and programming Guide MODEL VDI MK2

CQM1 I/O Terminal Block Conversion Adapter. Easy and secure replacement by reusing the I/O terminal block wiring.

DuoFern Multiple Wall Controller

Installation Instructions

T100&JY15-12 Series Variable Speed Peristaltic Pump Operating Manual

VK-3iX WARRANTY REGISTRATION FORM

Model 8732 IAQ-CALC TM Indoor Air Quality Meter

The Next-generation Sensor Networking Units That Revolutionize the Workplace from Introduction and Startup though Operation. Fiber Units.

MODEL ATV 4/6 BATTERY POWERED DIGITAL VACUUM INSTRUMENT

Name No. of I/O points Model Safety inputs: 12, test outputs: 4

Operator s Manual Fault Finder and Fault Finder / Remote

Product Documentation

Speaker Selectors Models SSW-4 and SSW-6. User Manual

2 CHANNEL, CLASS D AMPLIFIERS PA2X25 PA2X60 PA2X125 PA2X150. pulseaudio1.com vanco1.com

Operating Instructions

Continuous Wave Single Frequency Lasers. Concerto Series. 442nm 25, 50, 75 & 100mW

PRO Owner's Manual

Before starting the system, please carefully read this manual and keep it safely for future reference.

DIGITAL VOLTAGE INDICATOR

User's Guide. Model High Precision Quad Output DC Power Supply

Solid-state Timer H3FA. Model Number Structure. DIP Model Timer for PC Board Use Provides Contact and Solid-state Output

Series ST. User s Guide DIGITAL TORQUE TOOL TESTERS. .com. Series ST Torque Tool Testers. User s Guide

2/4/6 WAY LED POOL LIGHT CONTROL BOX USER MANUAL

FA-2448 SIX POSITION Filter Wheel

HDMI Extender over Cat5e/6

Conductive Level Controller

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

USER S MANUAL ENTITY. Energy Meter TRINITY. Entity Operational Manual

SATA II HDD Canister KISS DA 435 Quick Reference Guide

PRO 360. Owner's Manual

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Lotus DX. sit-stand workstation. assembly and operation instructions. MODEL # s: LOTUS-DX-BLK LOTUS-DX-WHT

Installation Instructions

DCM Digital Control Modules

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

INDOOR/OUTDOOR SPEAKER WITH BLUETOOTH WIRELESS TECHNOLOGY PART NUMBER PA360 EXPERIENCE 360 OF SOUND. pulseaudio1.com vanco1.com

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved.

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

INDOOR/OUTDOOR SPEAKER WITH BLUETOOTH WIRELESS TECHNOLOGY PART NUMBER PA360 EXPERIENCE 360 OF SOUND. pulseaudio1.com vanco1.com

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

WA4204-G2/G3 and WA4304-G2/G3

Exposure Monitoring. Model 8560 INSPECTAIR CO 2. Meter. Operation and Service Manual , Revision B June 2006

Table of Contents. 3.1 Front/Rear Panel and User Interface Front Panel Rear Panel User Interface...

BatteryCheck USER MANUAL BATTERY MANAGEMENT TECHNOLOGY THAT POWERS YOUR ADVENTURES.

COOPER POWER SERIES. RS-485 digital communications accessory board installation and operation instructions. Voltage Regulators MN225074EN

Connecting Sockets, Mounting Brackets, DIN Rails

DICKSON FH320/325 & FT300/325 DICKSON. Temperature/Humidity Recorder. Specifications. Applications & Product. Product. Contents: Getting Started

Electronic SD1, AS 8, ASR 14, ASR 20

G3FM. Model Number Structure. Ordering Information. Solid State Relays. Model Number Legend. List of Models

Temperature & Humidity Datalogger

B2800 FLOW MONITOR. - For Liquid Meters - PROGRAMMING & INSTALLATION MANUAL Simplified Version

Aton C6. Bedienungsanleitung. User Manual Mode d emploi Istruzioni per l uso

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2

PWRguard PLUS Spring City Drive Waukesha, WI

COBEX RECORDERS, INC.

MIYAWAKI ULTRASONIC TESTER PM11 OPERATOR S MANUAL. Be sure to read this manual for safe and proper operation. Store this manual carefully after use.

Profibus DP Expansion Board

Series STA DIGITAL TORQUE TOOL TESTERS. User s Guide

AirPro Surveyor 2 Manual

THECHARGEHUB.COM. User Manual. For Square & Round Models

Manual. NanoTron Dual Timer. Installation Maintenance Repair Manual

User s Guide. Series CT CLOSURE TORQUE TESTER. User s Guide

DVI Detective. User Manual EXT-DVI-EDIDN. Release A3

COOPER POWER SERIES. Input/Output (I/O) module installation instructions. Voltage Regulators MN225067EN

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL

NIMBUS a personal dashboard for your digital life

Quick Start Guide CJB1950ALAAB

Introduction. Package Contents. System Requirements

POWER SERIES Plus. 3 in 1 AC Voltage. Digital Switchboard Meter. User s Manual IM2493VVV-2

WCC100 IN-VEHICLE CHARGING CRADLE OWNER S MANUAL

Sensing method Appearance Connection method Sensing distance Model. Pre-wired (2 m) Power supply Application Appearance Function Model

ACL 350 Digital Static Locator

PS8 - II. Professional Power Sequencer. User s Manual

Number of input channels

Model A7BS

NE1A-SCPU Series. Safety Network Controller. Achieve Safety Control through Programming. Ordering Information. Specifications.

Series CTA CAP TORQUE TESTERS. User s Guide

NJ NJ-series NJ501 SECS/GEM CPU Unit. Allows SECS/GEM communications in a short time with a simple configuration. Feature

Transcription:

Badger Meter Europa GmbH INSTRUCTION MANUAL Deluxe LCD display for the MN series September 2001 Version MN-Deluxe LCD display-09/01-e

Content Content Page 1. To the owner 1 2. Important information 1 3. Description 2 4. Specifications 4 5. Change of battery 5 6. LC display view 6 7. Meter keys view 6 8. Operation view 7 9. Normal operation mode 7 10. Operation 8 11. Automatic operation mode 8 12. Fill quantity operation 9 13. Fault indicator 10 14. Calibration constant 11 15. Select measuring unit 12 16. Connections diagram 13 17. Amplifier diagram 14 18. Example applications 14 19. Summary tables 17 20. Warranty 18

To the owner Page 1/18 1. To the owner Thank you for purchasing a deluxe liquid crystal display. Please take a few minutes to read through this manual before installing and operating your display. If you have any problems with the display, refer to the maintenance and trouble shooting sections of this manual. This manual contains connection and operating instructions for the deluxe liquid crystal display. If you need further assistance, contact your local representative or us. The deluxe LC display is available on specific MN5, MN10, MN40 and MN50 series models. It is also available as an accessory so it can be used as a remote mounted display for any MN series meter model supplied without a display, e.g. MN1, MN2, etc. 2. Important information Please read this information carefully before use! Before use, confirm the fluid to be used is compatible with the meter (refer to the fluid compatibility chart) or consult your local representative for advice. Ensure that the inlet/outlet pipework is correctly aligned. Stress due to misalignment will damage the liquid meter. Shock pressure should not exceed the nominal pressure on the name plate. Excess pressure may damage the meter. Keep solvents away from keys and liquid crystal display. Do not clean electronic register with organic solvents. Amplifier, meter and other external equipment should only be installed and maintained by qualified personnel. Operators should have suitable instructions and training as to the systems operation. Electrical power should only be applied when the system has been tested and certified for use. Check all connections for tightness.

Important information Page 2/18 For use in hazardous locations! Observe certificate of conformity and operating instructions. The replacement of the battery must take place outside of the hazardous area. This is essential. Avoid electrostatic charge in both, the installation of the equipment and during operation. Only clean with a conductive damp cloth. For automatic operation in hazardous locations, only use approved amplifiers. EEx ia IIC T6 - Specification for explosion proof apparatus PTB Nr. EX-93.C.4033X - Certificate of conformity number 3. Description Normal operation The quantity of liquid passing through the meter will be measured and displayed (partial quantity counter). No additional devices are necessary. Automatic operation (presettable batch controller) A preset quantity can be transferred in automatic operation. In order to control valves, the motor of the pump and/or other similar devices by the meter, an amplifier according to NAMUR signals is required. The amplifier transforms the control signal from the meter into relay signals. For transferring foaming liquids or if shock pressures are too high The meter enables a measuring operation of a liquid in 3 steps. For this it is necessary to use 2 valves. Step 1: Both valves are open. Step 2: One valve closes (precise measuring operations starts). Step 3: The second valve closes.

Description Page 3/18 1 amplifier with 2 output signals, 2 valves and a regulating valve are required. Leakage quantity (time lag of the valves) If the OFF signal (close) is displayed, there will be a time lag before the valve will be closed. During this time an unknown quantity of liquid will pass through the meter. This quantity is called leakage quantity. The leakage quantity is measured by the meter during each measuring operation and it is taken into account when starting the next measuring operation. The current leakage quantity always depends on the previous measuring operation. Factory calibration Factory calibration is not protected and can be changed by the user. Calibration constant is entered prior to shipment. MN4 = 0089 MN5 = 0123 MN7 = 0192 MN10 = 0278 MN40 = 0689 MN50 = 1500

Specifications Page 4/18 4. Specifications Measuring unit : Can be set to litres, US gallons or imperial gallons. Imperial gallons = IMP GAL = 4.5460 litres. US gallons = US GAL = 3.7854 litres. Calibration constant : 10 different constants can be recorded. Each constant can be set by keys within the range of 0.0000 to 0.9999. Only the 4 points after the decimal point are displayed. Partial quantity counter : 7-digit display; 999999.9 litres maximum. 999999.9 gallons maximum. No overflow indication (the counter starts again at zero). Resettable to 0 by special combination of keys only. Totaliser : 7-digit display without decimal point; 9999999 litres maximum. 9999999 gallons maximum. Automatic range of presetting (Relative automatic operation) : To be set to 99.99, 999.9 or 9999 litres/gallons. Preset quantity (Relative automatic operation) : 10 different preset quantities can be set. The preset quantity can be within the predetermined range (automatic range of presetting). Presignal quantity (Relative automatic operation) : The set presignal quantity is valid for all preset quantities. The presignal quantity can be set between 0.0 and 9.9 litres/gallons.

Specifications Page 5/18 Cycle counter (Relative automatic operation) : No overflow indication (the counter starts again at zero). If the preset quantity is changed, this counter will reset to 0 automatically. 5. Change of battery In order to change the battery you have to remove the electronic display unit from the meter. Replacement of the battery must take place outside of the hazardous area (if applicable). Remove the 4 slotted screws and carefully take off the electronic display unit (refer to fig. 2). Unplug pulse from connection block 2 and replace battery (refer to fig. 3). NOTE: The battery has to be replaced within one minute. If the battery has not been replaced within one minute, all calibration constants will reset to 0.05000, all preset quantities will reset to 0 and all counters will reset to 0. If the battery has not been replaced within one minute, remove the battery again and short-circuit PIN 8 and PIN 9 on the connection block ST2 for at least 3 minutes in order to ensure a safe start-up of the electronics. A new battery may then be fitted.

LC display view Page 6/18 6. LC display view 7. Meter keys view

Operation view Page 7/18 8. Operation view 9. Normal operation mode To perform the following procedures in normal operation mode, refer to - Cancel total quantity (fig. 4) - Display flow rate (fig. 5)

Operation Page 8/18 10. Operation Display is flashing; change respective setting by + ; - or 1-10. The setting will be confirmed by pressing ENTER. 11. Automatic operation mode To perform the following procedures in automatic operation mode, refer to - Cancel total quantity (only possible in normal operation mode) - Display flow rate (fig. 6)

Fill quantity operation Page 9/18 12. Fill quantity operation Automatic operation mode Before pressing the keys At the first press of + or - the display starts flashing After pressing the keys Preset quantity is changed by pressing + or - ; depress for speed input. A change of the preset quantity will reset the cycle counter to 0 A register can be selected by pressing the (TOTAL) key 1--10 The display preset quantity will be confirmed by pressing the key ENTER. The meter switches automatically over to setting of the presignal quantity. Set precise quantity by + or - A change of the presignal quantity will not reset the cycle counter. The display presignal quantity will be confirmed by pressing the key ENTER. The meter switches automatically over to the preset quantity. Start filling cycle by the key START/STOP Filling cycle: - OFF changes to ON - Cycle counter increases - COUNT is flashing during measuring - Preset quantity is counted to 0 - ON changes to OFF - The leakage quantity is measured for 2 seconds - The set preset quantity is displayed again

Fault indicator Page 10/18 13. Fault indicator Fault indicator is flashing! "FFFF" Press the key "Enter" Clear fault Fault The presignal quantity plus the automatically measured leakage quantity are higher than the total filling quantity. Fault indicator is static! "FFFF" Increase total filling quantity or reduce presignal quantity or use higher speed valves (reduce leakage quantity) Press the key "Enter" remaining filling quantity is displayed. Continue measuring operation of the remaining filling quantity by pressing the key "Start/Stop" or No flow has been measured for 5 seconds Press again "Enter" back to the preselection quantity Refill tank or container with liquid Check amplifier, pump and valves for function Rotors do not turn (due to dirt, wear, etc.) Pulse is defective

Calibration constant Page 11/18 14. Calibration constant Selection or changes to the calibration constant can be effected in the normal or automatic operation mode. Press CAL for more than 5 seconds Briefly pressing + or - changes the calibration by 0.0001. Depress for speed input. The display constant will be set by pressing the key ENTER. The meter switches automatically back to the previous mode (normal or automatic operation).

Select measuring unit Page 12/18 15. Select measuring unit If the measuring unit is changed, all recorded calibration constants will be converted into the new unit. All recorded preset quantities will reset to 0. If the automatic range of presetting is changed, all recorded preset quantities will reset to 0. This mode can be set in normal and automatic operation mode: Press CAL. Then press simultaneously the keys + and -. Keep all three keys pressed for more than 5 seconds. Select the desired measuring unit by pressing the key + and -. The displayed measuring unit will be confirmed by pressing the key ENTER. The meter switches automatically over to the selection of the automatic range of presetting. Select the desired range by pressing the key + or -. The display range will be confirmed by pressing the key ENTER. The meter switches automatically back to the previous mode (normal or automatic operation).

Connections diagram Page 13/18 16. Connections diagram Back view of the LCD electronic: ST2 Connection block 2 2/1 No function 2/2 No function 2/3 Presignal (VS+) Outlet to amplifier 2/4 On/Off (main signal) (HS+) Outlet to amplifier 2/5 No function 2/6 External pulse Input for reed switch (1) Transmission by +3 Volts pulses (ST 2/9) 2/7 External Start/Stop (See example of application 2) 2/8 Minus (GND) 2/9 + 3 Volts reed switch (2) 3 Volt Note: The battery has to be removed when using the extended battery (refer to diagram above).

Amplifier diagram Page 14/18 17. Amplifier diagram Amplifier with 1 output 2 amplifiers with 1 output signal Amplifier with 2 output signal for installation into for installation into a switch board. signals for installation into a switch board. a switch board. 18. Example applications Connections and diagrams are typical. Actual installations may vary from those shown in this booklet. Example 1 Electronic display mounted on liquid meter; amplifier with 1 output signal for installation into a switchboard for controlling 1 valve. Refer to fig. 7. Necessary cable connections: A. Control cable from meter to amplifier. B. Voltage cable from amplifier to meter. Example 2 Electronic display mounted on liquid meter; amplifier with 1 output signal for installation into a switchboard for controlling 1 valve; external Start/Stop device. Refer to fig. 8.

Example applications Page 15/18 Necessary cable connections: A. Control cable from LC display to amplifier. B. Control cable from external Start/Stop to meter. Supply voltage cable from amplifier to valve. The cable has to be run from PIN 3 to 7 (in this case the presignal cannot be used).

Example applications Page 16/18 Example 3 Electronic display mounted onto quick action tap; amplifier with 1 output signal for installation into a switchboard controlling 1 valve. Liquid meter without display unit. Refer to fig. 9. Necessary cable connections: A. Pulse cable from LC display to quick action tap (max. 12m). B. Control cable from quick action tap to amplifier. C. Supply voltage cable from amplifier to valve.

Summary tables Page 17/18 19. Summary tables Summary table for normal operation: If the battery has not been removed within one minute, all registered constants will be reset to 0500. Factory calibration on location 01 with calibration fluid Location No. Location No. 01 Factory set (see above) 06 02 07 03 08 04 09 05 10 MN4=0089, MN5=0123, MN7=0192, MN10=0278, MN40=0689, MN50=1500 Summary table for automatic operation Presignal Calibration constant 01 to 10 Filling quantity 01 to 10 Location No. Location No. Location No. Location No. 01 06 01 06 02 07 02 07 03 08 03 08 04 09 04 09 05 10 05 10

Warranty Page 18/18 20. Warranty Badger Meter warrants that the products will be free from any defects caused by faulty material or workmanship for a period of twelve (12) months from the date of sale of the products to the enduser (the warranty period ) PROVIDED THAT, during the warranty period: 1. Badger Meter receives notice setting out full details of any defect in any product and details of the time and place of purchase of the product and 2. the enduser returns the product to Badger Meter or its nearest representative at its own costs. Badger Meter shall, as its option, repair or replace the product found defective by its inspection or refund the price paid by the enduser for that product. Badger Meter's liability and the enduser s rights under this warranty shall be limited to such repair, replacement or refund and, in particular, shall not extend to any direct, special, indirect or consequential damage or losses of any nature. Note: This warranty does not form part of, nor does it constitute, a contract between Badger Meter and the enduser. It is additional to any warranty given by the seller of the products and does not exclude, limit, restrict or modify the rights and remedies conferred upon the enduser, or the liabilities imposed on the seller, by any statute or other laws in respect of the sale of the product.

Hotline Tel. +49-7025-9208-0 or -31 Fax +49-7025-9208-15 Badger Meter Europa GmbH Subsidiary of Badger Meter, Inc. Karlstrasse 11 72660 Beuren (Germany) E-mail: badger@badgermeter.de