Multifunction Counter H7BX

Similar documents
H7BX CSM_H7BX_DS_E_4_4

DIN 48 x 48 Multifunction Counter/Tachometer with a Bright, Easy-to-view Negative Transmissive LCD. The H7CX Defines a New Standard.

Multifunction Counter/Tachometer H7CX Series

Multifunction Preset Counter H7CX

Digital Counter H7CZ. Easy to Use and Easy to Read. Features. Basic Features Better Readability Character Height of 10 mm with a Wide Viewing Angle.

Multifunction Counter/Tachometer

Model Number Structure

Solid-state Timer H3YN

Conforms to VDE0435/2021 C/250, VDE0110, VDE0106/P100 Conforms to EN , pren

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately)

Digital Timer Ultra-compact Timer Provides Advanced Functions and Security Settings. Features

Digital Counter H7CZ. Easy to Use and Easy to Read. Features. Basic Features Better Readability Character Height of 10 mm with a Wide Viewing Angle.

Model Number Structure

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

Digital Timer H5CZ. Easy to Use and Easy to Read. Features. Basic Features Better Readability Character Height of 10 mm with a Wide Viewing Angle.

Solid-state Timer. Mounting system contact t contact. t Surface mounting/ track mounting

Solid-state Timer. Ordering Information. Ultra-slim Timer for G2R Relay Socket. H3RN-jj. Accessories (Order Separately) Connecting Socket

Solid-state Timers H3DK

Solid-state Timers H3DK

KTC. Preset Counter/ Timer. Programmable Type. Model Number Legend SALIENT FEATURES. Sensing. Digital Panel Meters

H3CR-H. Solid-state Power OFF-delay Timer. Ordering Information. DIN 48 x 48-mm Solid-state Power OFF-delay Timer

Model Number Structure

Functional configuration Rated input voltage Power ratings Output voltage Output current Part number Non-PFC

Long-time range model (0.1 min to 10 h) 24 VAC; SPDT H3RN-1 H3RN-11 12, 24 VDC DPST-NO H3RN-2 H3RN-21

Model Number Structure

Appearance Size (mm) Power supply voltage Model (W H D) 100 to 240 VAC K3SC to 240 VAC

1/32 DIN Digital Panel Meter K3GN

Solid-state Counter. Power supply Output No voltage input (short/open circuit) Voltage input (high/low voltage) 30 cps 1 kcps 30 cps 1 kcps AC

Self-powered Totalizer New H7E

Self-Powered Counters H7EC

Model Number Structure

Model Number Structure

Voltage Current Front-mounting bracket

Switching Power Supply S82J. Ordering Information. Open-Frame, Covered-Frame, or Enclosed-Frame Type with Capacity Up to 600 W

Model Number Structure

Temperature/Process Meter

Model Number Structure. Cam Positioner H8PS. Model Number Legend

H7ER H7ER-V H7ER-V1 H7ER-V2 H7ER-V3

Monitoring Relays can be used to monitor 3-phase power supplies with 3 or 4 wires simply by changing DIP switch settings.

Solid-state Timer. Ordering Information. Specifications. Miniature Timer Compatible with the MY Relay. Accessories. Time Ranges

Ferrous metal (The sensing distance decreases with non-ferrous metal.) Power supply voltage (operating voltage range)

Self-powered Totalizer New H7E

Zelio Count - Counters RC87610

TIMERS FOR ALL APPLICATIONS

Digital Counter. DIN 48 x 48 mm Counters with Easy-to-use Functions

Programmable Relay ZEN V2 Units

Cam Positioner H8PS. Plastic body, 2 m (6.56 ft.) cable Metal body, 2 m (6.56 ft.) cable

Model Number Structure

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

3. Input KJ: Thermocouple P: Platinum resistance thermometer T: Thermocouple/platinum resistance thermometer (universal-input)

DIN 48 SIZE LCD ELECTRONIC COUNTER. UL File No.: E C-UL File No.: E122222

Solid-State Counter/Timer

D2VW. Sealed Miniature Basic Switch. Ordering Information Model Number Legend D2VW- -

Inductive Proximity Sensor

Electronic Preset Counter with 2 Presets and Print interface. NE213 Prog Features

Model Number Structure. 1/32 DIN Digital Panel Meter K3GN. Model Number Legend. Compact and Intelligent Digital Panel Meter K3GN VDC

Transistor I/O Link Modules

Time-limit contact Time ranges Supply voltage Mounting s to 3 h 24, 100 to 120, 200 to 230 VAC (50/60 Hz); 12, 24, 48, 125, 100 to 110 VDC

Rotary Encoder. Output configuration Open collector Voltage Line driver (see note 3)

1/32 DIN Digital Panel Meter K3GN

D2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend.

Switch Mode Power Supply S8VM (15/30/50/100/150/300/600/1,500-W Models)

Note: Each relay to be mounted must incorporate a coil that has proper specifications within the maximum rated voltage range.

Suitable for detecting transparent films or transparent bottles

Communications & Networking

Ordering Information. Snap Action Switch V. Model Number Legend V General Purpose Snap Action Switch. Snap Action Switch V 121

Inductive Proximity Sensor

2. Actuator B: Ball type P: Pin type F: Flat type

KCN-S/KCN-W. Merits. Single/Dual Preset Counters for Addition and Subtraction. Electronic. Counters

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

Safety Relay Unit (I/O Unit Type)

G9SX-LM. Low-speed Monitoring Unit. Low-speed Monitoring Function Ensures Safety for Maintenance Work. Model Number Structure.

DIN 48 SIZE DIGITAL TIMER. Compact, Easy-to-read, Easy-to-use... A digital timer made to meet the market s needs.

Switching Power Supply

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

Modbus Digital Remote I/O. ARM Series. Modbus Sensor Connector Type Digital Remote I/O. Features. User Manual For Communication. Ordering Information

Model Number Structure

Mini Photoelectric Sensor

Syr-line TMR48D Digital Timer

I/O delay. (0.32 in ±0.06 in)

Chapter. In This Chapter...

Thread length (overall length) material

Cylindrical Proximity Sensor

ON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 SPDT SPDT H3CA-8H H3CA-8H

4 mm. 8 mm. Proximity Sensor. Sensing head Sensing distance Output configuration Part Number M18 Shielded 4 mm DC 3-wire PNP-NO E2EZ-X4B1 M30

E4PA. Ultrasonic Displacement Sensor. Ordering Information

Rotary Encoder. Output configuration Open collector Voltage Line driver (see note 3) 35 ma max. Residual voltage: 0.7 V max.

User friendly and easy to program

Contact protection relay

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

Classification Preset Counter Totalizing Counter

Light ON 5m. * Light ON. 2.5m (3m) Light ON. (5m)

K3GN. Ordering Information. J Panel Meters. J Programming Software

Solid-state Timer H3FA. Model Number Structure. DIP Model Timer for PC Board Use Provides Contact and Solid-state Output

Ultra-small U-shaped Micro Photoelectric Sensor. Extremely small size enables space saving!! 12 mm in

COUNTER KCV KCX KCM TC-V TC-4 KT-V FC2-81 /FC2-161 /321 FC2-80 /FC2-160 /320

G60 SERIES ELECTRONIC PRESET COUNTER ESC P1 / P2 SHIFT RESET ENT

CPU Units with 20 I/O points

Solid State Relays with Failure Detection Function

Syr-line TMR48D Digital Timer

Transcription:

Multifunction Counter H7BX DIN 72 72 mm Multifunction Counter with a Bright, Easy-to-view, Negative Transmissive LCD. Highly visible display with backlit transmissive LCD. Selectable display color (red/green) enables checking output status at a distance. Easy operation with a key for each digit. Perform all basic settings with a DIP switch. Provides a total and preset counter, batch counter, dual counter, and tachometer (See note.). Wide range of inputs accepted for NPN/PNP inputs (multi-inputs) and 2- wire DC sensors. Complies with UL, CS, and CE marking. Degree of protection: IP54 equivalent (front section only). Be sure to read Safety Precautions on page 25. Note: The functions that can be selected depend on the model. Ordering Information List of Models External power supply Output type Supply voltage 1-stage 2-stage Contact and 1 to 24 VC H7BX- H7BX-W 12 VDC NPN transistor output 24 VC/12 to 24 VDC H7BX-D1 H7BX-WD1 ccessories (Order Separately) Name Soft Cover Hard Cover Terminal Cover (See note.) Note: Supplied with the H7BX. Model Y92-72F1 Y92-72 Y92-72T UDIN - 8, avenue de la malle - 5137 Saint Brice Courcelles - Tel : 3.26.4.2.21 - Fax : 3.26.4.28.2 - Web : http: www.audin.fr - Email : info@audin.fr Multifunction Counter H7BX 1

Specifications Ratings Item Model H7BX-/D1 H7BX-W/WD1 Type Preset counter Preset counter/tachometer Supported configurations Ratings Power supply voltage (See note 2.) Operating voltage range Power consumption 1-stage preset counter, total and preset counter (See note 1.) (selectable) 1 to 24 VC (5/6 Hz) 24 VC (5/6 Hz)/12 to 24 VDC (ripple 2% max.) 85% to 11% of rated supply voltage (9% to 11% at 12 VDC) H7BX-/W: 9.6 V max. (1 to 24 VC) H7BX-D1/WD1: 8 V max. (24 VC), 5.3 W max. (12 to 24 VDC) Flush mounting Screw terminals IP54 (front section only) CP1, CP2, reset 1, reset 2, key protection 3 Hz or 5 khz (selectable, ON/OFF ratio 1:1), setting for both CP1 and CP2 Note 1. The total and preset counter functions as a 1-stage preset counter and total counter. 2. Do not use an inverter output for the power supply. 3. Displayed only when the power is ON. Not displayed when the power is OFF. 1-stage preset counter, 2-stage preset counter, total and preset counter (See note 1.), batch counter, dual counter, tachometer (selectable) Mounting method External connections Degree of protection Input signals Max. counting speed Input modes Increment, decrement, command (UP/DOWN ), individual (UP/DOWN B), quadrature (UP/DOWN C) Output modes N, F, C, R, K-1, P, Q,, K-2, D, L N, F, C, R, K-1, P, Q,, K-2, D, L, H Counter One-shot output time.1 to 99.99 s Tachometer Reset input External reset (minimum reset input signal width: 1 ms or 2 ms selectable), manual reset, and automatic reset (internal according to C, R, P, and Q mode operation) Pulse measurement method --- Periodic measurement (Sampling period: 2 ms) Max. counting speed --- 3 Hz or 1 khz (selectable) Measuring ranges --- 3 Hz:.1 to 3. Hz 1 khz:.1 Hz to 1 khz Measuring accuracy --- ±.1% FS ±1 digit max. (at 23 ±5 C) Output modes --- Upper and lower limits, area, upper limit, lower limit uto-zero time ---.1 to 99.9 s Startup time ---. to 99.9 s verage processing --- OFF/2/4/8 times Prescaling function Yes (.1 to 99.999) Decimal point adjustment Yes (rightmost 3 digits) Sensor waiting time 29 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.) Response speed: pprox. 1 s No-voltage NPN input (fixed) Key protection input Short-circuit (ON) impedance: 1 kω max. (Leakage current at Ω: pprox. 12 m) Short-circuit (ON) residual voltage: 3 V max. Open (OFF) impedance: 1 kω min. Input method (except key protection input) No-voltage NPN input or voltage PNP input (selectable) No-voltage input Short-circuit (ON) impedance: 1 kω max. (Leakage current at Ω: pprox. 12 m) Short-circuit (ON) residual voltage: 3 V max. Open (OFF) impedance: 1 kω min. Voltage input High level: 4.5 to 3 VDC Low level: to 2 VDC Input resistance: pprox. 4.7 kω External power supply 12 VDC (±1%), 1 m (For details, refer to External Power Supply on page 26.) Contact output: 3 at 25 VDC/3 VDC, resistive load (cosφ = 1) Minimum applied load: 1 m at 5 VDC (Failure level: P, reference value) Control output Transistor output: 1 m max. at 3 VDC max. Residual voltage: 1.5 VDC max. (approx. 1 V) Leakage current:.1 m max. Backlit 7-segment negative transmissive LCD Character Heights Display (See note 3.) PV: 13.5 mm (red/green) SV: 9 mm (green) Digits Memory backup mbient operating temperature mbient storage temperature mbient operating humidity Case color ccessories 6 digits 99,999 to 999,999 (5 digits negative and 6 digits positive) 6 digits Counter: 99,999 to 999,999 (5 digits negative and 6 digits positive) Tachometer: to 999,999 (6 digits) EEPROM (Overwrites: 1, min.), Data storage: 1 years min. 1 to 55 C (with no icing) 25 to 65 C (with no icing) 25 to 85 C (with no condensation) Black (N1.5) Two flush-mounting adapters, terminal cover, DIP switch Two flush-mounting adapters, terminal cover setting stickers UDIN - 8, avenue de la malle - 5137 Saint Brice Courcelles - Tel : 3.26.4.2.21 - Fax : 3.26.4.28.2 - Web : http: www.audin.fr - Email : info@audin.fr 2 Multifunction Counter H7BX

Characteristics Insulation resistance Dielectric strength Impulse withstand voltage Noise immunity Static immunity Vibration resistance Shock resistance Life expectancy Weight 1 MΩ min. (at 5 VDC) between current-carrying terminal and exposed noncurrent-carrying metal parts, and between non-continuous contacts Between current-carrying metal parts and non-current-carrying metal parts: 2, VC, 5/6 Hz for 1 min Between power supply and input circuit: 2, VC, 5/6 Hz for 1 min (for models other than the H7BX-@D1) 1, VC, 5/6 Hz for 1 min (H7BX-@D1) Between control output, power supply, and input circuit: 2, VC, 5/6 Hz for 1 min Between non-continuous contacts: 1, VC, 5/6 Hz for 1 min Between power terminals: 3. kv (1. kv for 24 VC/12 to 24 VDC models) Between current-carrying terminal and exposed non-current-carrying metal parts: 4.5 kv (1.5 kv for 24 VC/12 to 24 VDC models) Between power terminals: ±1.5 kv Between input terminals: ±6 V Square-wave noise by noise simulator (Pulse width: 1 ns/1 µs, 1-ns rise) Malfunction: 8 kv Destruction: 15 kv Destruction: 1 to 55 Hz,.75-mm single amplitude for 4 cycles each in 3 directions (8 min/cycle) Malfunction: 1 to 55 Hz,.5-mm single amplitude for 4 cycles each in 3 directions (8 min/cycle) Destruction: 294 m/s 2 3 times each in 6 directions Malfunction: 98 m/s 2 3 times each in 6 directions Mechanical: 1,, operations min. Electrical: 1, operations min. (3 at 25 VC/3 VDC, resistive load) (See note.) pprox. 25 g Note: Check the electrical life expectancy curve. pplicable Standards pproved safety standards EMC curus: UL 58, CS C22.2 No. 14 EN 611-1 (IEC 611-1): Pollution degree 2/overvoltage category II; EN 61326; VDE 16 Part 1 (EMI) EN 61326 Emission Enclosure: EN 5511 Group 1 class Emission C mains: EN 5511 Group 1 class (EMS) EN 61326 Immunity ESD: EN 61-4-2: 4 kv contact discharge; 8 kv air discharge Immunity RF-interference: EN 61-4-3:1 V/m (mplitude-modulated, 8 MHz to 1 GHz); 1 V/m (Pulse-modulated, 9 MHz ±5 MHz) Immunity Conducted Disturbance: EN 61-4-6: 3 V (.15 to 8 MHz) Immunity Burst: EN 61-4-4: 2 kv power-line; 1 kv I/O signal-line Immunity Surge: EN 61-4-5: 1 kv line to lines (power and output lines (relay outputs)); 2 kv line to ground (power and output lines (relay outputs)) Immunity Voltage Dip/Interruption: EN 61-4-11:.5 cycle, 1% (rated voltage) Electrical Life Expectancy (Reference Values) Resistive Load No. of operations ( 1 3 ) No. of operations ( 1 3 ) 1, 7 5 3 1 25 VC (cosφ=1) 7 5 1 2 3 4 Load current () Inductive Load 1, 7 5 3 1 25 VC (cosφ=.4) 3 VDC (cosφ=1) 3 VDC (L/R=7 ms) 7 5 1 2 3 4 Load current () current of.15 max. can be switched at 125 VDC (cosφ = 1) and current of.1 max. can be switched with L/R = 7 m/s. In both cases, a life of 1, operations can be expected. UDIN - 8, avenue de la malle - 5137 Saint Brice Courcelles - Tel : 3.26.4.2.21 - Fax : 3.26.4.28.2 - Web : http: www.audin.fr - Email : info@audin.fr Multifunction Counter H7BX 3

I/O Functions Using as a Counter (See note 1.) Inputs CP1, CP2 Reset or Reset 1 Total Reset or Reset 2 Outputs, 2 (1) ll Modes Except for Dual Counter Mode Reads count signals. Increment, decrement, up/down (command, individual, or quadrature) inputs can be used. (2) Dual Counter Mode Reads CP1 count signals on CP1 input and CP2 count signals on CP2 input. Increment signals can be used. (1) ll Modes Except for Dual Counter Mode Resets present value and outputs ( when using the batch counter). (See note 2.) Counting cannot be performed while resetting or when reset 1 input is ON. The reset indicator is lit while the reset input is ON. (2) Dual Counter Mode Resets the CP1 present value to. Counting the CP1 input cannot be performed while the reset 1 input is ON. The reset indicator is lit while the reset 1 input is ON. The reset operation depends on the selected function. (See note 3.) When the corresponding set value is reached, signals are output according to the designated output mode. Note 1. Refer to pages 14 to 17 for information on the operation of input and output functions. 2. In increment mode or increment/decrement mode, the present value returns to ; in decrement mode, the present value returns to the set value with 1-stage models, and returns to set value 2 with 2-stage models. 3. The reset indicator will not be lit when the total reset or reset 2 input is ON. Function 1-stage/2-stage preset counter Total and preset counter Batch counter Dual counter Reset operation Does not operate (Not used). Resets the total count value. Holds the total count value at while the total reset input is ON. Resets the batch count value and batch output (). Holds the batch count value at while the reset 2 input is ON. Resets the CP2 present value. Counting for CP2 input is disabled while the reset 2 input is ON. Using as a Tachometer Inputs CP1, CP2 Reset 1, Reset 2 Outputs, 2 Using as a Counter or Tachometer Key protection input Note: For details, refer to page 24. Reads counting signals. (CP2 input is not available.) Holds the measurement value and outputs. (Reset 2 input is not available.) The reset indicator is lit during hold. Outputs signals according to the specified output mode when a set value is reached. Prohibits using the keys on the front panel. the key protection level in function selection mode. UDIN - 8, avenue de la malle - 5137 Saint Brice Courcelles - Tel : 3.26.4.2.21 - Fax : 3.26.4.28.2 - Web : http: www.audin.fr - Email : info@audin.fr 4 Multifunction Counter H7BX

Connections Terminal rrangement Confirm that the power supply meets specifications before using the H7BX. H7BX- H7BX-W V Reset 1 CP2 CP1 Unused. Unused. Unused. Reset 2 12 VDC Unused. Output COM V Reset 1 CP2 CP1 Reset 2 12 VDC Output COM 8 9 1 11 12 13 14 ( ) External power supply (+) Unused. 15 17 Key protection 16 OUT OUT 18 8 9 1 11 12 13 14 ( ) External power supply (+) Unused. 15 17 Key protection 16 18 1 2 3 4 5 6 7 1 2 3 4 5 6 7 Unused. H7BX-D1 H7BX-WD1 V Reset 1 CP2 CP1 Reset 2 12 VDC Output COM V Reset 1 CP2 CP1 Reset 2 12 VDC Output COM 8 9 1 11 12 13 14 8 9 1 11 12 13 14 Unused. ( ) (+) External power supply 15 17 Unused. Unused. ( ) (+) External power supply 15 17 Key protection 16 OUT OUT 18 Key protection 16 18 1 2 3 4 5 6 7 1 2 3 4 5 6 7 ( ) (+) Unused. Unused. Unused. ( ) (+) Unused. Note: Do not use the unused terminals for relay connections. Block Diagram Output circuit (Basic insulation) Input circuit (Basic insulation) Internal control circuit Power supply circuit Display circuit Key switch circuit Input Circuits CP1, CP2, Reset/Reset 1, and Total Reset/Reset 2 Input IN 1 kω +14 V Internal circuit Note: The circuit shown above is for no-voltage input (NPN input). UDIN - 8, avenue de la malle - 5137 Saint Brice Courcelles - Tel : 3.26.4.2.21 - Fax : 3.26.4.28.2 - Web : http: www.audin.fr - Email : info@audin.fr Multifunction Counter H7BX 5

Input Connections no-voltage input (short-circuit or open) or voltage input can be selected for each input. (The key protection input is always a no-voltage input (NPN input)). No-voltage Inputs (NPN Inputs) Open Collector Voltage Output Contact Input DC Two-wire Sensor PLC or sensor Sensor -V input Reset/reset 1 input CP2 input CP1 input Total reset/reset 2 input Key protection input -V input Reset/reset 1 input CP2 input CP1 input Total reset/reset 2 input Key protection input -V input Reset/reset 1 input CP2 input CP1 input Total reset/reset 2 input Key protection input -V input Reset/reset 1 input CP2 input CP1 input Total reset/reset 2 input Key protection input Terminal No. 8 9 1 11 12 16 Terminal No. 8 9 1 11 12 16 Terminal No. 8 9 1 11 12 16 Terminal No. 8 9 1 11 12 16 Operates when the transistor turns ON. Operates when the transistor turns ON. Operates when the contact turns ON. Operates when the transistor turns ON. Note: When the H7BX is used as a tachometer, the CP2 input and total reset/reset 2 input are not used. No-voltage Input Signal Levels No-contact input Short-circuit level Transistor ON Residual voltage: 3 V max. Impedance when ON: 1 kω max. (The leakage current is 5 to 12 m when the impedance is Ω.) Open level Transistor OFF Impedance when OFF: 1 kω min. Contact input Use contact which can adequately switch 5 m at 1 V. Note: Use a DC power supply of 3 V max. pplicable Two-wire Sensors Leakage current: 1.5 m max. Switching capacity: 5 m min. Residual voltage: 3 VDC max. Operating voltage: 1 VDC Voltage Inputs (PNP Inputs) No-contact Input (NPN Transistor) No-contact Input (PNP Transistor) Contact Input Sensor Sensor -V input Reset/reset 1 input CP2 input CP1 input Total reset/reset 2 input -V input Reset/reset 1 input CP2 input CP1 input Total reset/reset 2 input Terminal No. 8 9 1 11 12 Terminal No. 8 9 1 11 12 Operates when the transistor turns OFF. Operates when the transistor turns ON. Note: When the H7BX is used as a tachometer, the CP2 input and total reset/reset 2 input are not used. -V input Reset/reset 1 input CP2 input CP1 input Total reset/reset 2 input Terminal No. 8 9 1 11 12 Operates when the contact turns ON. Voltage Input Signal Levels High level (Input ON): 4.5 to 3 VDC Low level (Input OFF): to 2 VDC Note 1. Use a DC power supply of 3 V max. 2. Input resistance: pprox. 4.7 kω UDIN - 8, avenue de la malle - 5137 Saint Brice Courcelles - Tel : 3.26.4.2.21 - Fax : 3.26.4.28.2 - Web : http: www.audin.fr - Email : info@audin.fr 6 Multifunction Counter H7BX

MDE IN CHIN Nomenclature Indicators Reset Indicator (Orange) Lit when the reset input (1) or reset key is ON. B Key Protection Indicator (Orange) C Control Output Indicator (Orange) OUT: One stage, : Two stages D Present Value (Main Display) Character height: 13.5 mm (Red/green selectable) E Value (Sub-display) Character height: 9 mm (Green) B C F G H J Lot No. X X X X X X COUNTER H7BX- OMRON Corporation D E K I Operation Keys I Mode Key Used to switch mode and setting items. J Reset Key K Up Keys: L DIP Switch 1 to 6 Switches F Total Count Indicator (Green) Lit when the total count value is displayed. ON 1 2 3 4 5 6 7 8 G Batch Indicator (Green) Lit when the batch count value is displayed. L OFF H Value 1 and 2 Stage Indicators (Green) Dimensions (Unit: mm) Counter Counter H7BX-@@ 72 6 1 M3.5 terminal screw (effective length: 6 mm) 72 67.6 67.6 Note: M3.5 terminal screws (effective length: 6 mm). Dimensions with Flush Mounting dapter H7BX-@@ (The flush mounting adapter is supplied with the H7BX.) 72 M3.5 terminal screw (effective length: 6 mm) Panel Cutouts Panel cutouts are as shown below (according to DIN 437). 68 +.7 1 min. 72 69 69 68 +.7 82 min. Panel 6 12 5 + panel thickness Note: The mounting panel thickness must be 1 to 5 mm. ccessories (Order Separately) Soft Cover Y92-72F1 Note: Depending on the operating environment, the condition of resin parts may deteriorate, and may shrink or harden. Therefore, it is recommended that resin parts are replaced regularly. Product Protection for Use in Environments Subject to Water or Oil The panel surface has a protective structure so that the internal circuits will not be adversely affected if drops of water penetrate the gaps between the keys. If, however, there is a possibility of water or oil being present on the operator's hands, mount the optional Soft Cover. The Soft Cover ensures protection equivalent to IP54. Do not, however, use the H7BX in locations where it would come into direct contact with oil. Hard Cover Y92-72 Terminal Cover (See note.) Y92-72T (VDE16/T1) Note: Supplied with the H7BX. UDIN - 8, avenue de la malle - 5137 Saint Brice Courcelles - Tel : 3.26.4.2.21 - Fax : 3.26.4.28.2 - Web : http: www.audin.fr - Email : info@audin.fr Multifunction Counter H7BX 7

Operating Procedures ting Procedure Guide tings for Counter Operation (1-stage/2-stage Counter, Total and Preset Counter, Batch Counter, Dual Counter) Using Basic tings Only Basic tings Counting speed (3 Hz, 5 khz) Input mode (UP, DOWN) Output mode (N, F, C, K-1) One-shot output time (.5 s,.5 s) Reset input signal width (2 ms, 1 ms) NPN/PNP input mode (NPN, PNP) The settings can be made easily with the DIP switch. For details on the setting methods, refer to page 9. ON OFF 1 2 3 4 5 6 7 8 Using Input Modes Not Given bove (Up/Down, Up/Down B, Up/Down C), Output Modes (R/P/Q//K-2/D/L/H), or () Output Time all functions with the operation keys. For details on the setting methods, refer to page 1. Performing dvanced tings: Dual Count Calculating Mode, Output 1 Time, Decimal Point Position, Prescale Value, Display Color, or Key Protect Level tings other than the basic functions above can be performed with the operation keys. For details on the setting methods, refer to page 1. Note: The default setting is for a 1-stage preset counter. (For models with a 2-stage setting, the default is a 2-stage preset counter.) ting for Tachometer Operation (H7BX-W@ only) Using Basic tings Only Basic tings Counting speed (3 Hz, 1 khz) Output mode (HI-LO, RE, HI-HI, LO-LO) verage processing (OFF, 2, 4, 8 times) NPN/PNP input mode (NPN, PNP) The settings can be made easily with the DIP switch. For details on the setting methods, refer to page 19. ON OFF 1 2 3 4 5 6 7 8 Performing dvanced tings: Decimal Point Position, Prescale Value, uto-zero Time, Startup Time, Display Color, or Key Protect Level tings other than the basic functions above can be performed with the operation keys. For details on the setting methods, refer to page 2. Note: The default setting is for a 2-stage preset counter. UDIN - 8, avenue de la malle - 5137 Saint Brice Courcelles - Tel : 3.26.4.2.21 - Fax : 3.26.4.28.2 - Web : http: www.audin.fr - Email : info@audin.fr 8 Multifunction Counter H7BX

MDE IN CHIN COUNTER H7BX- Operating Procedures (Counter Function) tings for Basic Operations tings for basic functions can be performed with just the DIP switch. Lot No. X X X X X X OMRON Corporation Be sure to turn ON pin 1 when using the DIP switch. ON 1 2 3 4 5 6 7 8 OFF Item OFF ON 1 DIP switch settings enable/disable Disabled Enabled 2 Counting speed 3 Hz 5 khz 3 Input mode UP (increment) DOWN (decrement) 4 5 Output mode Refer to the table on the right. 6 One-shot output time (See note.).5 s.5 s 7 Reset input signal width 2 ms 1 ms 8 NPN/PNP input mode NPN (no-voltage) PNP (voltage) Note: ll the pins are factory-set to OFF. Pin 4 Pin 5 Output mode OFF OFF N ON OFF F OFF ON C ON ON K-1 The ON/OFF status of the DIP switch pins can be confirmed using the front display. For details, refer to page 23. Convenient Function Caution lways turn OFF the power supply before changing the DIP switch settings. lways turn ON pin 1 when performing settings with the DIP switch. Performing settings with the DIP switch is disabled when pin 1 is OFF. DIP switch setting changes will be updated when the power is turned ON. Perform the settings before performing installation and supplying power. Properly set the DIP switch to match the item being counted (or measured) and use the DIP switch monitor for confirmation. Use the keys on the front panel to perform all settings for input modes, output modes, and output times that cannot be set with the DIP switch. For details on the setting methods, refer to page 1. When performing these settings, always turn OFF pin 1(DIP switch setting) (disabled). Using the H7BX as a Total and Preset Counter, Batch Counter, or Dual Counter The default setting is for a 1-stage preset counter. (For models with a 2-stage setting, the default is for a 2-stage preset counter.) To make changes, use the procedure shown on the right. For details, refer to page 23. Configuration selection mode Power ON Run mode Hold down the Key and press the Up 1 Key for at least 1 s. The mode will not change if the Up 1 Key is pressed first. Configuration selection (1-stage preset counter) (2-stage preset counter) Key + Up 1 Key for at least 1 s (See note.) Select the configuration using the Up Key. (The configurations that can be selected depend on the model.) (Total and preset counter) (Batch counter) (Dual counter) (Tachometer) Note: This includes using a model with a 2-stage setting as a 1-stage preset counter. fter setting the DIP switch for basic operations, advanced functions (see note) can be added using the operation keys. For details, refer to page 1. Note: dvanced functions consist of dual count calculating mode, output 1 time, decimal point position, prescale value, display color, and key protect level. UDIN - 8, avenue de la malle - 5137 Saint Brice Courcelles - Tel : 3.26.4.2.21 - Fax : 3.26.4.28.2 - Web : http: www.audin.fr - Email : info@audin.fr Multifunction Counter H7BX 9

When using the H7BX as a Total and Preset Counter, Batch Counter, or Dual Counter, switch the configuration using the procedure on page 23. ting dvanced Functions tings that cannot be performed with the DIP switch are performed with the operation keys. Power ON Run mode See note 1. 3 s min. See note 2. 3 s min. For details on operations and display in run mode, refer to page 12. The display depends on the configuration used. Note: 1. If the mode is switched to the function setting mode during operation, operation will continue. 2. Changes made to settings in function setting mode are enabled for the first time when the mode is changed to run mode. lso, when settings are changed, the counter is reset (present value initialized and output turned OFF) on returning to run mode. The characters displayed in reverse video are the default settings. When performing settings with operation keys only, turn OFF pin 1 of the DIP switch (factory setting). If pin 1 of the DIP switch is ON, the setting items indicated by will not be displayed. Function setting mode See note 3. Input mode (CNTM) Output mode (OUTM) See note 7. See note 5. See note 5. (UP) (DOWN) (UP/DOWN ) (UP/DOWN B) (UP/DOWN C) Note 5: Displayed for output modes other than K-2, D, L, and H only. Note 3: When using as a dual counter Dual count calculating mode (DD) the output mode with any of the Up Keys. (ddition)(subtraction) Note 4: Displayed only when See note 6. See note 6. See note 6. See note 6. the output mode is K-2, D, L, or H. (N) (F) (C) (R) (K-1) (P) (Q) () (K-2) (D) (L) (H) Note 6: For models with a 2-stage setting, the input mode is displayed only when an Up/Down Mode is selected. Note 7: the number for each digit with the Up Keys. 2-stage Preset Counter the number for each digit with the Up Keys. Output time Output 2 (OTIM) time (OTM2) Counting speed (CNTS) Min. reset period (IFLT) the input mode with any of the (.1 s) (.5 s) (99.99 s) Note: Displayed only when the output mode is C, R, K-1, P, Q,, or K-2. the counting speed with any of the Up Keys. (3 Hz) (5 khz) (2 ms) No decimal point (1 ms) One digit after decimal point Up Keys. the min. reset input signal width with any of the Decimal point the decimal point position with any of the Up Keys. position (DP) Two digits after decimal point Up Keys. Three digits after decimal point Batch Counter the dual count calculating mode the Up Key. Output 1 time (OTM1) Output 2 time (OTM2) See note 4. (.1 s) (.5 s) (99.99 s) Note: Displayed only when the output mode is C, R, K-1, P, Q,, or K-2. (Outputs held) (.1 s) (99.99 s) If the output time is., hold is displayed. Note 1: Displayed for output modes other than D, L, and H. Note 2: HOLD cannot be set when the output mode is K-2. (.1 s)(.5 s)(99.99 s) Note: Displayed only when the output mode is C, R, K-1, P, Q,, or K-2. Prescale value (PSCL) the number for each digit with the (.1) (1.) (99.999) Up Keys. NPN/PNP input mode (IMOD) the NPN/PNP input mode with any of the Up Keys. (NPN input) (PNP input) Display color (COLR) the display color with any of the Up Keys. (Red) (Green) (Redgreen) (Greenred) Key Protection Level (KYPT) the key protect level with any of the Up Keys. (KP-1) (KP-2) (KP-3) (KP-4) (KP-5) UDIN - 8, avenue de la malle - 5137 Saint Brice Courcelles - Tel : 3.26.4.2.21 - Fax : 3.26.4.28.2 - Web : http: www.audin.fr - Email : info@audin.fr 1 Multifunction Counter H7BX

Explanation of Functions tings marked with a star can be performed with the DIP switch. Input Mode (cntm) increment mode (UP), decrement mode (DOWN), or one of the increment/decrement modes (UP/DOWN, UP/DOWN B, or UP/DOWN C) as the input mode. Input modes other than UP or DOWN modes cannot be set using the DIP switch. Use the operation keys if other modes are required. (For details on the operation of the input modes, refer to Input Modes and Present Value on page 13.) Dual Count Calculating Mode (calm) When the H7BX using as a dual counter, select either DD (addition) or SUB (subtraction) as the calculation method for the dual count value. DD: Dual count value = CP1 PV + CP2 PV SUB: Dual count value = CP1 PV CP2 PV Output Mode (outm) the way that control output for the present value is output. The possible settings are N, F, C, R, K-1, P, Q,, K-2, D, L, and H. Output modes other than N, F, C, or K-1 cannot be set using the DIP switch. Use the operation keys if other modes are required. The output modes that can be set vary with the model. (For details on the operation of the output modes, refer to Input/ Output Mode tings on page 14.) One-shot Output Time (otim) the one-shot output time (.1 to 99.99 s) for the control output. one-shot output can be used only when C, R, K-1, P, Q,, or K-2 is selected as the output mode. Output times other than.5 s or.5 s cannot be set with the DIP switch. Use the operation keys if other settings are required. One-shot Output 2 Time (otm2) When the H7BX using as a 2-stage counter or batch counter, set the one-shot output time (.1 to 99.99 s) for control output (). one-shot output can be used only when C, R, K-1, P, Q,, or K-2 is selected as the output mode. Output times other than.5 s or.5 s cannot be set with the DIP switch. Use the operation keys if other settings are required. One-shot Output 1 Time (otm1) When the H7BX using as a 2-stage counter, set the one-shot output time (.1 to 99.99 s) for control output (). oneshot output can be used only when D, L, or H is selected as the output mode. If the output time is set to., hold is displayed, and outputs are held. Counting Speed (cnts) the maximum counting speed (3 Hz/5 khz) for CP1 and CP2 inputs together. If contacts are used for input signals, set the counting speed to 3 Hz. Processing to eliminate chattering is performed for this setting. Reset Input Signal Width (iflt) the reset input signal width (2 ms/1 ms) for reset/reset 1 and total reset/reset 2 inputs together. If contacts are used for input signals, set the counting speed to 2 ms. Processing to eliminate chattering is performed for this setting. Decimal Point Position (dp) Decide the decimal point position for the present value, CP1/ CP2 present values, set values (SV1, SV2), total count value, dual count value and dual count set value. Prescale Value (pscl) Pulses input to the counter are converted according to the specified prescale value. ting range:.1 to 99.999 Example: To display the feed distance for systems that output 25 pulses for a feed length of.5 m in the form @@.@@ m: 1. the decimal point position to 2 decimal places. 2. the prescale value to.2 (.5 25)..5 m Encoder NPN/PNP Input Mode (imod) Select either NPN input (no-voltage input) or PNP input (voltage input) as the input format. For 2-wire sensors, set the format to NPN input. The same format setting applies to all external inputs. For information on input connections, refer to page 6. Display Color (colr) the color used for the present value. 25 pulses Note: Incorrectly setting the prescale value will result in counting errors. Check that the setting has been performed correctly before using the H7BX. Output OFF (See note.) Output ON (See note.) red Red (fixed) grn Green (fixed) r-g Red Green g-r Green Red Note: When the H7BX using as a 2-stage counter, this is the status of output 2. Key Protect Level (kypt) the key protect level. For details, refer to Key Protect Level on page 24. UDIN - 8, avenue de la malle - 5137 Saint Brice Courcelles - Tel : 3.26.4.2.21 - Fax : 3.26.4.28.2 - Web : http: www.audin.fr - Email : info@audin.fr Multifunction Counter H7BX 11

Operation in Run Mode the number for each digit with the Up Keys. 1-stage Counter 2-stage Counter Present value value Present value value 1 Present Value Shows the present count value. Value ( Value 1, Value 2) the set value. When the present value reaches the set value, signals are output according to the specified output mode. Present value value 2 Total and Preset Counter Present value value Present Value/ Value Same as 1-stage counter. Total Count Value Shows the present total count value. Total count value Batch Counter Dual Counter Present value value Batch count value Batch count set value Present Value/ Value Same as 1-stage counter. Batch Count Value Shows the number of times the count has been completed for the present value. Batch Count Value the batch count set value. When the batch count value reaches the batch count set value, batch output () turns ON. Dual count value Dual count set value CP1 present value CP2 present value Dual Count Value Shows the sum of the CP1 present value and CP2 present value when the dual count calculating mode is DD and shows the value obtained by subtracting the CP2 present value from the CP1 present value when the dual count calculating mode is SUB. Dual Count Value the dual count set value. When the dual count value reaches the dual count set value, signals are output according to the specified output mode. CP1/CP2 Present Value Show the present count values for CP1 and CP2 present values respectively. UDIN - 8, avenue de la malle - 5137 Saint Brice Courcelles - Tel : 3.26.4.2.21 - Fax : 3.26.4.28.2 - Web : http: www.audin.fr - Email : info@audin.fr 12 Multifunction Counter H7BX

Input Modes and Present Value (See note 1.) CP1: Count input; CP2: Prohibit input UP (Increment) Mode CP1: Count input; CP2: Prohibit input DOWN (Decrement) Mode CP1 H L CP1 H L CP2 H L Prohibit CP2 H L n Prohibit 5 n 1 Present value 2 3 4 Present value n 2 n 3 n 4 1 n 5 must be greater than the minimum signal width. (See note 2.) CP1: Prohibit input; CP2: Count input must be greater than the minimum signal width. (See note 2.) CP1: Prohibit input; CP2: Present value H CP1 L (See note 3.) CP2 H L Prohibit H CP1 L (See note 3.) CP2 H L n Prohibit 5 n 1 Present value 2 3 4 Present value n 2 n 3 n 4 1 n 5 must be greater than the minimum signal width. (See note 2.) must be greater than the minimum signal width. (See note 2.) UP/DOWN : Command Input Mode UP/DOWN B: Individual Input Mode CP1 H L CP1 H L CP2 H L CP2 H L B Present value 1 3 3 2 2 2 must be greater than the minimum signal width. (See note 2.) CP1 CP2 H L H L Present value UP/DOWN C: Quadrature Input Mode B B B B 1 must be at least 1/2 the minimum signal width. (See note 2.) 1 3 3 2 2 2 1 Present value 1 3 3 2 2 2 1 1 Note 1. If the configuration is set to dual counter, CP1 and CP2 inputs will operate in the same way as the count input (CP1) of UP (increment) mode. 2. must be greater than the minimum signal width and B must be at least 1/2 the minimum signal width. If they are less, a count error of ±1 may occur. Minimum signal width: 16.7 ms (when maximum counting speed = 3 Hz) 1 µs (when maximum counting speed = 5 khz) 3. The meaning of the H and L symbols in the tables is explained below. Input method Symbol No-voltage input (NPN input) Voltage input (PNP input) H Short-circuit 4.5 to 3 VDC L Open to 2 VDC UDIN - 8, avenue de la malle - 5137 Saint Brice Courcelles - Tel : 3.26.4.2.21 - Fax : 3.26.4.28.2 - Web : http: www.audin.fr - Email : info@audin.fr Multifunction Counter H7BX 13

Input/Output Mode tings Operation for 1-stage models is the same as that for. When using a 2-stage model as a 1-stage counter, total and preset counter, or dual counter, and turn ON and OFF simultaneously. Self-holding output One-shot output from Self-holding output (The one-shot output time can be set in the range.1 to 99.99s.) One-shot output from Input mode UP DOWN UP/DOWN, B, C Operation after count completion Reset/ reset 1 N 999999 value 2 value 1 The outputs and present value display are held until reset/reset 1 input turns ON. Reset/ reset 1 F 999999 value 2 value 1 The present value display continues to increase/decrease. The outputs are held until reset/reset 1 input turns ON. Output mode setting C Reset/ reset 1 999999 value 2 value 1 s soon as the count reaches SV, the present value display returns to the reset start status. The present value display does not show the present value upon count-up. The outputs repeat oneshot operation. self-holding output turns OFF after the one-shot output time. The one-shot output time is independent of. R Reset/ reset 1 999999 value 2 value 1 The present value display returns to the reset start status after the one-shot output time. The outputs repeat oneshot operation. self-holding output turns OFF after the one-shot output time. The one-shot output time is independent of. K-1 Reset/ reset 1 999999 value 2 value 1 The present value display continues to increase/decrease. self-holding output turns OFF after the one-shot output time. The one-shot output time is independent of. UDIN - 8, avenue de la malle - 5137 Saint Brice Courcelles - Tel : 3.26.4.2.21 - Fax : 3.26.4.28.2 - Web : http: www.audin.fr - Email : info@audin.fr 14 Multifunction Counter H7BX

Self-holding output One-shot output from Self-holding output (The one-shot output time can be set in the range.1 to 99.99s.) One-shot output from Input mode UP DOWN UP/DOWN, B, C Operation after count completion P Reset/ reset 1 999999 value 2 value 1 The present value display does not change during the one-shot output time period, but the actual count returns to the reset start status. The outputs return to the one-shot start state and repeat one-shot operation. self-holding output turns OFF after the one-shot output time. The one-shot output time is independent of. Output mode setting Q Reset/ reset 1 999999 value 2 value 1 The present value continues to increase/ decrease for the one-shot output time, but returns to the reset start status after the one-shot output time has elapsed. The outputs repeat oneshot operation. self-holding output turns OFF after the one-shot output time. The one-shot output time is independent of. Reset/ reset 1 999999 value 2 value 1 The present value display and self-holding output is held until reset/ reset 1 input turns ON. and are independent. Note 1. When the present value reaches 999999, it returns to. 2. Counting cannot be performed while the reset/reset 1 input is ON. 3. If reset/reset 1 input turns ON while the one-shot output is ON, one-shot output turns OFF. 4. If there is power failure while an output is ON, the output will turn ON again when the power supply has recovered. For a one-shot output, the output will turn ON again for the duration of the output time setting once the power supply has recovered. 5. Do not use the counter function in applications where the count may be completed (again) while the one-shot output is ON. 6. The set values are between and 999999. UDIN - 8, avenue de la malle - 5137 Saint Brice Courcelles - Tel : 3.26.4.2.21 - Fax : 3.26.4.28.2 - Web : http: www.audin.fr - Email : info@audin.fr Multifunction Counter H7BX 15

Input mode UP/DOWN, B, C Self-holding output Instantaneous (equals) output One-shot output (The one-shot output time can be set in the range.1 to 99.99s.) Operation after count completion K-2 Reset/reset 1 999999 value 2 value 1 99999 The display continues to increase/ decrease until the overflow or underflow value is reached. Only a one-shot output is possible. D Reset/reset 1 999999 value 2 value 1 99999 The display continues to increase/ decrease until the overflow or underflow value is reached. The outputs are ON while the count is equal. Output mode setting L Reset/reset 1 999999 value 2 value 1 99999 The display continues to increase/ decrease until the overflow or underflow value is reached. is held while the present value is less than or equal to set value 1. is held while the present value is greater than or equal to set value 2. H Reset/reset 1 999999 value 2 value 1 99999 The display continues to increase/ decrease until the overflow or underflow value is reached. is held while the present value is greater than or equal to set value 1. is held while the present value is greater than or equal to set value 2. Note: H mode is available only when using a 2- stage counter. Note 1. Counting cannot be performed while the reset/reset 1 input is ON. 2. If reset/reset 1 input turns ON while the one-shot output is ON, the one-shot output turns OFF. 3. If there is power failure while the output is ON, the output will turn ON again when the power supply has recovered. For a one-shot output, the output will turn ON again for the duration of the output time setting once the power supply has recovered. 4. Do not use the counter function in applications where the count may be completed (again) while the one-shot output is ON. 5. The set values are between 99999 and 999999. UDIN - 8, avenue de la malle - 5137 Saint Brice Courcelles - Tel : 3.26.4.2.21 - Fax : 3.26.4.28.2 - Web : http: www.audin.fr - Email : info@audin.fr 16 Multifunction Counter H7BX

Total and Preset Counter Operation The H7BX has a total counter separate from the 1-stage preset counter for counting the total accumulated value. Reset/reset 1 Total reset/reset 2 Present value 999999 Total count value The total counter continues to count the total accumulated value when the present value is reset using reset/reset 1 input (Reset Key). The total count value is reset when the total reset/ reset 2 input is turned ON. If the Reset Key is pressed while the total count value is displayed, the total count value is reset. The present value is also reset at this time. The counting range of the total counter is 99,999 to 999,999. The total count value returns to when it reaches the full scale limit. Batch Counter Operation The H7BX has a batch counter separate from the 1-stage preset counter for counting the number of times the count has been completed. Reset 1 Reset 2 (batch counter reset) value Present value Batch count set value (Sub-display) Batch count value (Main display) 1 2 The batch counter continues after count completion. Batch output is held until batch counter reset input turns ON. When the batch counter reset input is turned ON, the batch count value is reset, and batch output turns OFF. If the Reset Key is pressed while the batch count value is displayed, the batch count value is reset and batch output turns OFF. The present value is also reset at this time. (batch output) Note 1. The batch count value is held at while the batch counter reset input is on. 2. If the batch count set value is, batch count will be performed but there will be no batch output. 3. The batch count value returns to when it reaches 999,999. 4. Once batch input has been turned ON, it will return to the ON state after power interruptions. 5. If the batch count set value is changed from a value that is greater than the batch count value to one that is less, batch output will turn ON. 6. fter batch output turns ON, the ON state will be held even if the batch count set value is changed to a value greater than the batch count value. Dual Counter Operation Note: The above is for when the output mode is C. Using the dual counter allows the count from 2 inputs to be added or subtracted and the result displayed. It is possible to specify a set value for which output turns ON when the set value matches the added or subtracted result. (1) Dual Count Calculating Mode = DD Dual count value = CP1 PV + CP2 PV (2) Dual Count Calculating Mode = SUB Dual count value = CP1 PV - CP2 PV Reset 1 (CP1 reset) Reset 2 (CP2 reset) Dual count set value Dual count value CP1 present value CP2 present value Reset 1 (CP1 reset) Reset 2 (CP2 reset) Dual count set value Dual count value CP1 present value CP2 present value The operation after count completion for the dual counter value is determined by the output mode. The CP1 present value is reset when reset 1 input is turned ON and the CP2 present value is reset when reset 2 input is turned ON. If the Reset Key is pressed while the dual count value, CP1 present value, or CP2 present value is displayed, all of the present values are reset and the outputs turn OFF. t this time, counting is not possible for CP1 or CP2 inputs., 2 Note: The above is for when the output mode is N., 2 Note: The above is for when the output mode is K-2. SUB mode can be used only when K-2, D, L, or H is selected as the output mode with 6-digit models. Note 1. Counting is not possible for CP1 while the reset 1 input is ON. CP2 is not affected. The dual count value will be calculated based on a CP1 present value of. 2. Counting is not possible for CP2 while the reset 2 input is ON. CP1 is not affected. The dual count value will be calculated based on a CP2 present value of. 3. The counting range for the dual count value is 99,999 to 999,999. The counting ranges for the CP1 present value and CP2 present value are to 999,999. If a present value exceeds 999,999, FFFFFF will be displayed to indicate an overflow, and all counting will stop. UDIN - 8, avenue de la malle - 5137 Saint Brice Courcelles - Tel : 3.26.4.2.21 - Fax : 3.26.4.28.2 - Web : http: www.audin.fr - Email : info@audin.fr Multifunction Counter H7BX 17

Reset Function List Function Display in run mode Reset/reset 1 1-stage/2-stage counter Present value/set value (1, 2) Present value and output reset. Total and preset counter Batch counter Dual counter Present value/ set value Total count value Total reset/reset 2 No effect. Only the total count value is reset. Reset Key Present value and output reset. Present value/ set value Batch count value/batch count set value Dual count value/dual count set value CP1 present value/cp2 present value Present value and output reset. Present value and output reset. Only the CP1 present value is reset. Present value and output reset. Present value, total count value, and output reset. Batch count value and batch output reset. Present value and output reset. Present value, batch count value, output and batch output reset. Only the CP2 present value is reset. CP1 present value, CP2 present value, dual count value, and output reset. UDIN - 8, avenue de la malle - 5137 Saint Brice Courcelles - Tel : 3.26.4.2.21 - Fax : 3.26.4.28.2 - Web : http: www.audin.fr - Email : info@audin.fr 18 Multifunction Counter H7BX

MDE IN CHIN COUNTER H7BX- Operating Procedures (Tachometer Function) (H7BX-W@ only) Switching from Counter to Tachometer The H7BX is factory-set to the 2-stage counter configuration. To switch to the tachometer configuration, use the procedure shown on the right. For details, refer to page 23. Configuration selection mode Power ON Run mode Note: Hold down the Key and then press the Up 1 Key for at least 1 s. The mode will not change if the Up 1 Key is pressed first. Configuration selection Key + Up 1 Key for at least 1 s (See note.) Switch from 2cnt to taco (tachometer) with the Up Key. tings for Basic Operations tings for basic functions can be performed with just the DIP switch. Lot No. X X X X X X OMRON Corporation Be sure to turn ON pin 1. ON 1 2 3 4 5 6 7 8 OFF Item OFF ON 1 DIP switch settings enable/disable Disabled Enabled 2 Counting speed 3 Hz 1 khz 3 4 5 Tachometer output mode Refer to the table on the right. 6 verage processing Refer to the table on the right. 7 --- --- --- 8 NPN/PNP input mode NPN PNP Note: ll pins are factory-set to OFF. Pin 3 Pin 4 Tachometer output mode OFF OFF Upper and lower limit ON OFF rea OFF ON Upper limit ON ON Lower limit Pin 4 Pin 5 verage processing OFF OFF OFF (no average processing) ON OFF 2 times OFF ON 4 times ON ON 8 times The ON/OFF status of the DIP switch pins can be confirmed using the front display. For details, refer to page 23. Convenient function Caution lways turn OFF the power supply before changing the DIP switch settings. lways turn ON pin 1 when performing settings with the DIP switch. Performing settings with the DIP switch is disabled when pin 1 is OFF. DIP switch setting changes will be updated when the power is turned ON. Perform the settings before performing installation and supplying power. Properly set the DIP switch to match the item being counted (or measured) and use the DIP switch monitor for confirmation. fter setting the DIP switch for basic operations, advanced functions (see note) can be added using the operation keys. For details, refer to page 2. Note: dvanced functions consist of the decimal point position, prescale value, auto-zero time, startup time, display color, and key protect level. UDIN - 8, avenue de la malle - 5137 Saint Brice Courcelles - Tel : 3.26.4.2.21 - Fax : 3.26.4.28.2 - Web : http: www.audin.fr - Email : info@audin.fr Multifunction Counter H7BX 19

When the H7BX using as a tachometer, switch to the tachometer configuration using the procedure given on page 23. tings for dvanced Functions tings that cannot be performed with the DIP switch are performed with the operation keys. Power ON Run mode (See note 1.) 3 s min. (See note 2.) 3 s min. For details on operations in run mode, refer to page 22. Note: 1. If the mode is switched to the function setting mode during operation, operation will continue. 2. Changes made to settings in function setting mode are enabled for the first time when the mode is changed to run mode. lso, when settings are changed, the counter is automatically reset (measured values initialized and outputs turned OFF) on returning to run mode. The characters displayed in reverse video are the initial values. When performing settings with operation keys only, turn ON pin 1 of the DIP switch to OFF (factory setting). If pin 1 of the DIP switch is ON, the setting items indicated by will not be displayed. Tachometer output mode (TOTM) the tachometer output mode with any of the Up Keys. (HI-LO) (RE) (HI-HI) (LO-LO) Counting speed (CNTS) the counting speed with any of the Up Keys. (3 Hz) (1 khz) Decimal point position (DP) Prescale value (PSCL) the decimal point position with any of the Up Keys. (No decimal point) (.1) (One digit after decimal point) (1.) (99.999) (Two digits after decimal point) the number for each digit with the Up Keys. (Three digits after decimal point) Function setting mode verage processing (VG) uto-zero time (UTZ) the average processing with any of the Up Keys. (No average processing) (.1 s) (verage of 2 measurements) (99.9 s) (verage of 4 measurements) (verage of 8 measurements) the number for each digit with the Up Keys. Startup time (STMR) the number for each digit with the Up Keys. (. s) (99.9 s) NPN/PNP input mode (IMOD) the NPN/PNP input mode with any of the Up Keys. (NPN input) (PNP input) Display color (COLR) the display color with any of the Up Keys. (Red) (Green) (Red-green) (Green-red) Key protect level (KYPT) the key protect level with any of the Up Keys. (KP-1) (KP-2) (KP-3) (KP-4) (KP-5) UDIN - 8, avenue de la malle - 5137 Saint Brice Courcelles - Tel : 3.26.4.2.21 - Fax : 3.26.4.28.2 - Web : http: www.audin.fr - Email : info@audin.fr 2 Multifunction Counter H7BX

Explanation of Functions tings marked with a star can be performed with the DIP switch. Tachometer Output Mode (totm) the output method for control output based on the / set value. Upper and lower limit (HI-LO), area (RE), upper limit (HI-HI), and lower limit (LO-LO) can be set. (For details on the operation of the output modes, refer to Output Mode tings on page 22.) Counting Speed (cnts) the maximum counting speed (3 Hz/1 khz) for CP1 input. If contacts are used for input signals, set the counting speed to 3 Hz. Processing to eliminate chattering is performed for this setting. Decimal Point Position (dp) Decide the decimal point position for the measurement value, set value, and set value. Prescale Value (pscl) It is possible to display the rate of rotation or the speed of a device or machine to which the H7BX is mounted by converting input pulses to a desired unit. If this prescaling function is not used, the input frequency (Hz) will be displayed. The relationship between display and input is determined by the following equation. the prescale value according to the unit to be displayed. Displayed value = f α f: Input pulse frequency (number of pulses in 1 second) α: Prescale value 1. Displaying the Rotation Rate Display unit Prescale value (α) rpm 1/N 6 rps 1/N N: Number of pulses per revolution Example: In order to display the rate of rotation for a machine that outputs 5 pulses per revolution in the form @@.@ rpm: 1. the decimal point position to 1 decimal place. 2. Using the formula, set the prescale value to 1/N 6 = 6/5 = 12. 2. Displaying the Speed Display unit Prescale value (α) m/min πd 1/N 6 m/s πd 1/N N: Number of pulses per revolution d: Diameter of rotating body (m) πd: Circumference (m) Note: Incorrectly setting the prescale value will result in counting errors. Check that the setting has been performed correctly before using the H7BX. d: Diameter of rotating body uto-zero Time (avt) It is possible to set the H7BX so that if there is no pulse for a certain time the display is force-set to. This time is called the auto-zero time. the auto-zero time to a time slightly longer than the estimated interval between input pulses. It will not be possible to make accurate measurements if the auto-zero time is set to a time shorter than the input pulse cycle. ting a time that is too long may also result in problems, such as a time-lag between rotation stopping and the alarm turning ON. Startup Time (stmr) In order to prevent undesired output resulting from unstable input immediately after the power supply is turned ON, it is possible to prohibit measurement for a set time. This time is called the startup time. It can also be used to stop measurement and disable output until the rotating body reaches the normal rate of rotation, after the power supply to the H7BX and rotating body are turned ON at the same time. NPN/PNP Input Mode (imod) Select either NPN input (no-voltage input) or PNP input (voltage input) as the input format. Select an NPN input when using a 2- wire sensor. The same setting is used for all external inputs. For details on input connections, refer to Input Connections on page 6. Display Color (colr) the color used for the measurement value. Control output OFF Control output ON Note 1. If the tachometer output mode is set to RE, however, the measured value is displayed in red when control output 1 is OFF and in green when control output 1 is ON. 2. If the tachometer output mode is set to RE, however, the measured value is displayed in green when control output 1 is OFF and in red when control output 1 is ON. Key Protect Level (kypt) verage Processing (aug) the key protect level. Flickering display and output chattering can be prevented by For details, refer to Key Protect Level on page 24. using average processing (simple averaging). verage processing can be set to one of four levels: no average processing, 2 times (i.e., the average of 2 measurement values), 4 times, or 8 times. The measurement cycle will be equal to the sampling cycle (2 ms) multiplied by the average processing setting (i.e., the number of times). verage processing enables fluctuating input signals to be displayed stably. the optimum number of times for the application. UDIN - 8, avenue de la malle - 5137 Saint Brice Courcelles - Tel : 3.26.4.2.21 - Fax : 3.26.4.28.2 - Web : http: www.audin.fr - Email : info@audin.fr red grn r-g (See note 1.) g-r (See note 2.) Display Comparison value (lower limit) Power supply Output (lower limit) Measured value displayed in red when both control outputs 1 and 2 are OFF. Measured value displayed in green when both control outputs 1 and 2 are OFF. Startup time Red (fixed) Green (fixed) Time Measured value displayed in green when either control output 1 or control output 2 is ON. Measured value displayed in red when either control output 1 or control output 2 is ON. Multifunction Counter H7BX 21