Hubbell Power Systems

Similar documents
TTC Series Torque Tool Tester Operation Manual

Single Phase Vacuum Capacitor Switch. UltraVacLT 15kV 95kV or 125kV BIL

Installation and Operation

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

PS/IO Circuit Board Retrofit

trimble r10 GNSS System

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

2200 Series. Quick Start Guide SAFETY CHECKLIST. Safety Made Simple

FG-7000L Digital Force Gauge Operation Manual

U P S USER S MANUAL IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. Uninterruptible Power System. Line Interactive (Network) UPS

Autoranging True RMS Multimeter User Manual

Model ST-FT1 DIGITAL FORCE / TORQUE INDICATOR. User s Guide

DIGITAL VOLTAGE INDICATOR

SensorWATCH Basic RH - Wireless Setup Users Help Guide Part Number: A Revision: 1.1.0

SHIMPO INSTRUMENTS. FG-7000T Digital Torque Gauge Operation Manual

Kolectric Research. MC8022 Covermeter. Document number IM Iss 1 Copyright 2014 Tallix Ltd

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

Model HM-535 Power Supply Installation and Service Instructions

Abstract. GLV User Manual 1

Accu-Dose Radiation Measurement System. Quick-Start

TABLE OF CONTENTS TABLE OF CONTENTS... 1 MANUAL REVISION HISTORY... 2 IMPORTANT SAFETY NOTICE...

TC100 Precision Thermocouple Calibrator

BORESCOPE INSTRUCTIONS INSPECTION CAMERA RANGE RBS100 RBS200 RBS300. Retain these instructions for future reference

OPERATION & MAINTENANCE SPECIFICATIONS MANUAL 09 07

EnCell Battery Cell Monitor

Configuration. S&C Scada-Mate Switching System Outdoor Distribution (14.4 kv through 34.5 kv)

Copyright ANRITSU. All rights reserved.

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V

OFFICE UPS MULTI-DEVICE PROTECTION UPS 500S/600S/750S

Mini Digital Multimeter

Seeker HL In-Home Leakage Detector. User s Guide

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

VARIA REARVIEW RADAR RTL510/ RTL511. Owner s Manual

Contents 1 Warnings, Cautions, and Notes Description Features... 1

Primary Injection Test Procedure

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD)

Quick Guide v. 1.1 DeFelsko Corporation USA 2012

OPERATING INSTRUCTION

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Installation NOTICE. S&C IntelliCap Automatic Capacitor Control. Table of Contents. Instruction Sheet

Model: VA/230W UPS Backup System

Trimble R10 MODEL 2 GNSS SYSTEM. C WARNING For safety information, refer to the Safety Information FIVE SIMPLE STEPS TO GET STARTED

TASER CAM HD Recorder User Manual

MAXIMA + Series ROTARY LEVEL CONTROL

Help Guide. Getting started. Use this manual if you encounter any problems, or have any questions. What you can do with the Bluetooth function

Mini Digital Multimeter

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX310

ABM International, Inc. Lightning Stitch Checklist 9/13/2013

R E V O L U T I O N U S E R G U I D E

1. Place your CD driver in your PC drive for software installation 2. Follow the instruction on the screen to finish the software installation

GuardTrak II. User s Manual. Securing your world PDF created with FinePrint pdffactory trial version

EO-BG930. User Manual. English (EU). 07/2016. Rev.1.0.

Table of Contents. 1 Welcome. 2 Install your Access Point-I. 3 Using the Access Point-I

Lightning Stitch Assembly

smartentry Wireless Video Doorphone User Manual

User Manual Revised 1-July-2015

FG-7000 Digital Force Gauge Operation Manual

INSTALLATION AND OPERATING INSTRUCTIONS DSST SYSTEM

COOPER POWER SERIES. RS-485 digital communications accessory board installation and operation instructions. Voltage Regulators MN225074EN

XPS 15 2-in-1. Service Manual. Computer Model: XPS Regulatory Model: P73F Regulatory Type: P73F001

NI PXI-1042 POWER SUPPLY SHUTTLE USER GUIDE

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

Mini Digital Multimeter Model MN15. User's Guide

HHTQ35 Digital Torque Gauges

Quick Reference Guide VT30 TPM SERVICE TOOL VT30. Version: MJC-1409-US2. QRG3814d

THANK YOU FOR PURCHASING NETCOMM S MYZONE

S Contents. Figure 1. Kyle Form 4C Analog Current Metering Accessory KME

Xemio-154 User Manual

MAXIMA+ Series Rotary Level Indicator

VXi V200 User Guide. VoIPon Tel: (0) Fax: +44 (0)

CF3000 Dealer Diagnostic Tool Instruction Manual

On the right side, you will find a headphone jack closest to you, followed by Volume Down and Volume Up buttons.

DFS Series User s Manual (5N-1000N Capacity)

Model No INSTRUCTION MANUAL. Manual should be read prior to operation!

Ward s Single Probes. When All You Need is One

HOBO Motor On/Off Data Logger (UX90-004x) Manual

EL-WiFi-TH -

Help Guide. Getting started. Use this manual if you encounter any problems, or have any questions. What you can do with the Bluetooth function

PosiTector DPM. Dew Point Meter. INSTRUCTION MANUAL v Simple. Durable. Accurate.

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

Revolabs Fusion Wireless Microphone System. User s Guide. Microphones must be fully charged and paired to the Fusion Base Station prior to first use.

ISP Tester. Operating Instructions

AEROTRAK HANDHELD AIRBORNE PARTICLE COUNTER MODEL 9306 QUICK START GUIDE

Product Manual ASL Document Ref.: U doc Issue: 04 complete, approved - Date: 16/08/10 Part Number: M0618_23

Thank you for your purchase USER MANUAL

VARIA UT800. Owner s Manual

tracer Operating Manual Non-Contact AC Voltage Detector U.S. Patent No. 9,091,707

COOPER POWER SERIES. 600 A U-OP visible break connector system operation instructions. Deadbreak Apparatus Connectors MN650022EN

DX4085 Z-Meter Tester

COOPER POWER SERIES. Form 4C microprocessor-based recloser control standard and automation power supply kit installation and operation instructions

R-LB R-LX Series Installation, Operation & Maintenance Manual

EXM Configuration Tool EXM System Configuration Instructions

Firmware version Operation may differ from other firmware versions

Coating Thickness Tester

CALOG CALOG - LC DISPLAY. Loadcell Display. English Users Manual. Rev. 1.10

PHOENIX CONTACT - 07/2006

BTH-800. Wireless Ear Muff headset with PTT function

Chicony Standard Bluetooth Keyboard Users Manual. Model No.: KT-1063

FG-3000R Digital Force Gauge Operation Manual

Transcription:

Hubbell Power Systems Polymer Insulator Tester Operating Instructions Manual PSC403-3679 Rev.3 Hubbell has a policy of continuous product improvement. Please visit hubbellpowersystems.com to confirm current design specifications. This product was the result of collaborative research performed by the Electric Power Research Institute Inc. 2015 Hubbell Incorporated hpsliterature@hubbell.com hubbellpowersystems.com

! CAUTION The equipment covered in this manual must be used and serviced by competent, trained personnel familiar with and following approved work and safety practices. This equipment is for use by such personnel and this manual is not intended as a substitute for adequate training and experience in safe procedures for this type of equipment. These instructions neither cover all details or situations in equipment use, nor do they provide for every possible contingency to be encountered in relation to installation, operation or maintenance. Should additional information and details be desired or if situations arise which are not covered adequately for the user s purpose, the specifics should be referred to Hubbell Power Systems. NOTICE Before operating the Polymer Insulator Tester, thoroughly read, understand and follow these instructions. Keep these instructions in the device case for future reference.! WARNING Use only with the appropriate length universal pole even if wearing rubber gloves. Maintain proper working clearance between operator and all energized parts of the system. Failure to follow these warnings could result in personal injury. NOTICE This document is only intended to provide guidance on utilizing the functions of the Polymer Insulator Tester (PIT) Tool. It does not provide guidance on how to assess the condition of an insulator. 2

1. Overview The Polymer Insulator Tester (PIT) instrument is used to test the electrical integrity of non-ceramic or polymer insulators. The instrument is made for use in the field under energized or de-energized conditions. The tester must be used with a hot stick of appropriate length that provides adequate safe clearances. The unit attaches to the hotstick via the universal fitting. V Probes - The PIT test instrument has two forked V probes that interface directly with the insulator sheath. A mechanical adjustment is provided on the instrument so that the user can match the V probe spacing to the insulator shed spacing. The V probes are spring-loaded and must contact the insulator with positive pressure in order to take a measurement. One of the V probes transmits an electrical stimulus signal to the insulator, while the other V probe has a built-in sensor that is designed to receive the stimulus signal.! WARNING When the PIT tool is making a measurement a high voltage exists between the probes (approximately 1.5 kv @ 1.5 MHz). Contact with the probes during operation should be avoided to prevent injury. Guard Probes - The PIT test instrument has guard probes that shield the V probes from the 60-Hz electric field of the power lines. The guard probes are made of spring steel that allows them to bend upon contact with the insulator sheds. The guard probes are easily removable for replacement or storage but must be installed for proper measurements. Bonding Probe - The PIT test instrument has a bonding probe on one side that contacts the insulator end fitting when measurements are made at the end sheds. On the energized side, the bonding probe will conduct an arc as it approaches the insulator and protects the instrument. The user must make sure that the instrument is oriented with the bonding probe side nearest the end fitting (Energized or Deenergized) when measurements are taken at the first few, and last few, sheds. 3

2. Calibration The instrument stores calibration measurements that are taken from a known good insulator or are known to represent a good insulator of a particular size/rating/brand. Measurements are compared to the calibration values in order to establish pass/fail results. Instrument calibration depends primarily on the following factors: Probe Spacing Insulator Diameter Insulator Polymer Thickness Ambient Temperature The user must calibrate the instrument when any of the above factors have changed or if the unit has not been calibrated within the last 24 hours, preferably each time it is used, and recognize changes in test conditions that might require recalibration. Note: 1. Insulators with different fiberglass rod sizes require calibration. 2. Insulators with different thicknesses of rubber surrounding the fiberglass rod require calibration. Different manufacturers may have different thicknesses. 3. The size, number, and style of insulator sheds are not necessarily a factor. 4. Ambient temperature changes must be fairly significant (e.g., 10 degrees Celsius = 18 degrees Fahrenheit or more) to require a new calibration. Normal operating temperature is 0-50 C. To make testing different size insulators in the field easier, the instrument can store three (3) different calibrations in memory (Cal1, Cal2, and Cal3). The stored calibrations are retained even after a power cycle. The calibration that is selected can be confirmed from the WiFi interface (see WiFi Operation Section). Short sections of insulator rods without sheds are provided in the PIT transit case as part of the kit to aid with calibration when a known good insulator of the same type as that being tested in the field is not available. These sample rods are intended to be used for calibration measurements prior to testing insulators of the same size in the field. The instrument selects the calibration to use based on the probe engagement conditions when it is powered on. Calibration mode is ready for selection when the green calibration lights and the white LED light are flashing. Manual Calibration In order to calibrate manually, use the following steps: NOTICE It is important that the PIT instrument is not handheld by the user when taking calibration measurements. The instrument should be mounted to the hotstick so that its configuration is the same as it will be when taking the insulator measurements in the field. Step 1: Power up the instrument and select the calibration mode that you want to change. Cal Preset 1 Power on the unit using the power switch. When the green lights start flashing, engage and release either one of the v-probes. The unit will beep twice after the power up has completed. The white LED will be flashing and only one of the green LEDs will be illuminated. 4

Cal Preset 2 Power on the unit using the power switch. When the green lights start flashing, engage and hold in the v-probe on the bonding probe side until the unit beeps. The white LED will be flashing and two of the green LEDs will be illuminated. Cal Preset 3 Power on the unit using the power switch. When the green lights start flashing, engage and hold in the v-probe opposite of the bonding probe side until the unit beeps. The white LED will be flashing and all three of the green LEDs will be illuminated. Step 2: Wait until the instrument boot-up is complete and the White LED is flashing which signifies that it is ready for a calibration measurement. Step 3: Engage the instrument to the sample insulator rod with the unit installed on the hotstick just like it will be used in the field. Step 4: Wait for the measurement to complete like normal. Step 5: Turn off the instrument. Step 6: Repeat for Cal 1, 2, 3 as desired. Note: The new calibration values are stored in permanent memory immediately after the measurement and will not be lost. Selecting a Calibration Setting for Use Only one calibration preset can be active during operation. The desired preset is activated as follows: Cal Preset 1 Power on the unit using the power switch. Do not engage either of the v-probes. After power up, 1 green LED will be illuminated. Cal Preset 2 Engage and hold in the v-probe on the bonding probe side. Power on the unit using the power switch. Continue holding in the v-probe until the unit powers up and beeps twice. 2 green LEDs will be illuminated. Cal Preset 3.Engage and hold in the v-probe opposite of the bonding probe side. Power on the unit using the power switch. Continue holding in the v-probe until the unit powers up and beeps twice. 3 LEDs will be illuminated. Note: Factory re-calibration is not required unless operator suspects an issue or unit has been mishandled. 5

3. Basic Operation Measurements are triggered automatically upon engagement of the probes with the insulator. For basic operation, the user adjusts the probe spacing so they easily fit between the insulator sheds, sets the power switch to the ON position, waits for the instrument to boot up, and then engages the V probes with an insulator. The instrument automatically takes a measurement once the V probes are both engaged for about one second. Feedback is provided to the user with LEDs and audible tones to indicate instrument status, probe engagement status, and measurement status. The audible tones are generally redundant with the LED information but audible tones are helpful when visual sight of the LEDs is obstructed due to the insulator position with respect to the hotstick. Note: the PIT instrument must be calibrated before it can report valid pass/fail results (see Calibration Section for details on that) Green Result Pass Red Result Fail Calibration Indicators Amber Warning/ Busy White Ready/ Power On Blue Probe Engaged Power Switch Battery Status Blue Probe Engaged 6

Instrument Status - The White LED indicates that power is ON. When first powered ON, the instrument beeps and then the 3 green calibration lights flash for several seconds while internal memory is being read. When the memory read is complete, all of the LEDs are flashed and two more beeps are sounded. The unit then turns on WiFi and after a few more seconds beeps one more time to indicate that WiFi is available if needed. At this point, only the White LED should be on indicating that the instrument is ready to take a measurement. If the White LED is flashing, then the instrument needs to be calibrated (see Calibration Section for details). If the Amber LED is on, then the instrument has a low battery state and must be corrected before it can be used (See Battery Charging Section for details). Probe Engagement Status - The two Blue LEDs on the ends correspond with the two V probes and indicate their engagement status. Different tone beep rates are associated with the two V probes so that when only one probe is engaged the user can tell which side to apply more pressure to even if the Blue LEDs are not visible. Measurement Status - A steady Amber LED and audible tone indicate that a measurement is taking place. This takes about one second, after which the results are immediately displayed. The Green LED and a slow beep indicate a good section of insulator is detected, while the Red LED and a fast lower frequency tone indicate a bad section of insulator is detected. Simultaneous illumination of the Green, Amber, and Red LEDs and a fast higher frequency tone indicate an invalid measurement which most commonly occurs when the one or both of the probes are disengaged from the insulator in the middle of a measurement. The measurement status indications continue until the probes are disengaged. 4. Making a Measurement The following process is used to make a measurement: 1. The PIT tool must be attached to a hotstick using the universal hotstick fitting 2. Adjust the spacing between the probes so that the PIT tool V-Probes will engage on the sheath section of an insulator without interfering with the sheds. 3. The PIT tool should be calibrated using the process described in Section 2. A calibration should be performed if: a. The unit has not been calibrated in 12 hours b. A different type of insulator is being tested to that calibrated on c. The temperature has changed significantly since the calibration (e.g., 10 degrees Celsius = 18 degrees Fahrenheit or more). Normal operating temperature is 0-50 C. d. The spacing between the probes has been adjusted 4. The unit is switched on using the Power Switch and is fully booted when the White LED is on. 5. The unit is pushed, using a hotstick, so that the V-probes engage the sheath section of the insulator as shown in the figure below. a. Each spring loaded V-probe must be fully engaged for a measurement to be initiated. Whether a probe engaged is indicated by i. A blue light in-line with each probe ii. An audible tone (each probe has a different tone associated with it) b. When both probes are simultaneously engaged a measurement will start indicated by a beeping sound. The probes must not be removed during this time as an invalid measurement will result (reported by all LEDS flashing) c. When the measurement is complete it will be reported to the user whether the tested section is considered Pass or Fail by a Green or Red LED and audible tone. d. When the V-probes are disengaged from the sheath section the LWNCI stops reporting whether the section tested has passes or failed. e. The bonding probe (shown in previous photograph) should be on the side that is closest to either end fitting of the insulator. This only becomes critical when the unit is closer than 300 mm (12 ) away from an end fitting. 7

f. When measuring the section of insulator adjacent to either of the end fittings, the bonding probe should be in contact with the metal end fitting (or corona ring) to prevent arcing. If arcing is present between PIT tool and the insulator end fitting a measurement should not be made. 8

5. Battery Charging The PIT instrument uses a rechargeable Lithium Ion battery pack located inside the unit. It is expected to provide good service life and is not intended for field replacement. The battery pack should be fully charged overnight prior to each day of use. The battery is sized to last a full 8-hour day but it is advisable to only power the instrument when it s actively being used. The battery has internal protection circuitry that will disable it if it becomes over-discharged. If this ever happens, it should automatically recover when charged again. Power Switch Charge Port Battery Status A charger is provided along with cables for use with standard 110V AC wall outlets and with standard 12V DC vehicle power outlets. The instrument has built-in circuitry and status LEDs for the battery charging function. Battery charging is only possible when the instrument Power Switch is in the OFF position. The Amber Battery Charge Status LED indicates when power is applied to the Battery Charging Jack and the Power Switch is in the OFF position to allow charging. The Green Battery Charge Status LED indicates when charging is complete; this may take several hours depending on the state of charge. The Red Battery Charge Status LED indicates when charging has failed or has been suspended; this is likely due to a battery problem but may also have to do with the ambient conditions (e.g. the temperature may be too cold). If the Red Battery Charge Status LED persists after multiple charging attempts, then the battery will need to be replaced. 9

6. WiFi Operation The PIT instrument has an embedded wireless user interface to allow monitoring from a WiFi-enabled device such as a lap top computer. The instrument uses an adhoc network to communicate. It does not have Internet connectivity. The WiFi-enabled device must have an Opera Mini or Chrome browser; it does not need any other special software or app. Internet Explorer is not recommended at this time because it does not properly render the user interface graphics which may cause confusion. Once the instrument is powered up and WiFi is activated, the WiFi enabled device should see a network named "pwenlwncl_open". To connect to a laptop computer, load the two GUI files (Connect LWNCI and Disconnect LWNCI) supplied on the thumb drive included with the instrument onto the laptop's desktop. Once that is complete, double click the file "Connect LWNCI" and then press any key. Turn the polymer insulator tester on and calibrate if necessary. Left click on you internet icon on your laptop and find "pwenlwncl_open". Select and click on "connect". Next, go to your Opera Mini or Chrome browser and enter HTTPS://192.168.1.1:8085 in the address line. On the next page, select "Advanced" and then select "Proceed to 192.168.1.1 (unsafe)". Select "Continue" on the Hubbell home page. You do not need to fill in the user name or password. The tester will beep twice to indicate you have successfully connected and the test page will be visible on your laptop. To disconnect, close your browser and right click on the " Disconnect LWNCI" GUI and select Run as administrator. 10

7. Measurement Interpretation PIT instrument measurements use three primary metrics as follows: Abbreviation Metric Description pka pkb Freq Peak Sensor Channel A Peak Sensor Channel B Resonant Frequency Received signal peak amplitude during resonance on one side of the "V" fork Received signal peak amplitude during resonance on other side of the "V" fork Strongest frequency detected after sweeping the transmit signal Metric values are reported on a 0-4095 scale, i.e., a 12-bit digital reading. Pass or fail results are determined by comparing these readings to calibration readings along with a plus-and-minus tolerance that defines the acceptable range. Several other secondary metrics are used to validate the measurement. Examples of secondary metrics are battery voltage, battery current, temperature, resonant frequency failure, etc. If any secondary metrics fail then the measurement is considered invalid or indeterminate. If all secondary metrics pass then the measurement result is determined to be green (pass) or red (fail) based on the primary metrics when compared to the calibration values and tolerances. If any primary metrics fail then the result is reported as a failure. 8. USB Port The PIT instrument has a USB port located next to the power switch. This interface provides diagnostic, firmware, and internal memory utilities. At this point it is not documented and only intended for engineering development purposes. 11

Hubbell Power Systems, Inc. 1850 Richland Ave. E Aiken, SC 29801 www.hubbellpowersystems.com Hubbell has a policy of continuous product improvement. Please visit hubbellpowersystems.com to confirm current design specifications. TD_08_027_E 2015 Hubbell Incorporated hpsliterature@hubbell.com hubbellpowersystems.com