TMS Series Analog Output Board Installation Instructions

Similar documents
MODELS PD230 AND PD1230 Installation Instructions

P-Series Bear Bones I/O Expander USER S MANUAL. For P-Series Based Bear Bones Controllers ICM-IO-C21 ICM-IO-C24. Revision: 1.

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

genesis genesis Expander Unit - Technical Manual TECHNICAL MANUAL Australian Owned, Designed and Manufactured Expander Unit GEN-010

genesis Master Unit GEN-001 genesis Master Unit - Technical Manual TECHNICAL MANUAL Australian Owned, Designed and Manufactured

MRS ELECTRONIC DATASHEET CAN 4 ANA DESCRIPTION TECHNICAL SPECIFICATION REGULATORY APPROVALS AND TESTING SOFTWARE/PROGRAMMING

AquaController Apex Probe Module 2

Installation & Operation Guide

American Power Design, Inc.

MAN MAY 2003 PAGE 1 OCX VDC Bipolar Digital In 10-28VDC, 0.5A Sourcing Digital Out ±10V, ±20mA Analog In/Out HE500OCX404 / HE500RCX404

PCI-FPGA-1B User Guide

AquaController Apex Probe Module 2

Stepnet. Module. Provides Mounting & Connections for Stepnet Module CANopen Stepping Motor Driver DEVELOPMENT KIT

DC425 NEMA 4X Analog Output Transducers

T775S Series 2000 Expansion Module

Expert I/O 1000 Hardware User Manual

Connecting a Cisco Input Module

EAP 300 REMOTE ANNUNCIATOR INSTALLATION MANUAL. r.0454a

PX165. DMX Splitter INSTRUCTION MANUAL

Environdata FA ma Converter Guide

PX 227. DMX Demux 8. Manual

Intellia Input /Output modules for FX fire detection system

1.3 Operating Conditions -40 F to 150 F (-40 C to 65 C) 0% to 90% Relative Humidity, non-condensing

PRODUCTION DATA SHEET

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

4 Channel 4-20mA/0-10V Industrial Media Converter

5B Series 16 Channel Backplane 5B01 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Technical Note Series

FEATURES DESCRIPTION MODEL 110B. Power Supply

24 Input/8 Output AC Block I/O Module

BNI IOL K023 BNI IOL K023. User s Guide

DNETEXT-C CAN Bus Extender, Version 3 User s Manual. Brad Harrison

Schneider Electric s SCD series of duct mount sensors measure the levels of CO 2. , RH (if equipped) and temperature of air inside a duct.

TM0-1 AMPLIFIER / CONDITIONER MODULE OPERATORS MANUAL. Transducer Techniques R

OPERATION MANUAL MODEL TT-LP

TB6600 Stepper Motor Driver

TC22/23/24/25 Capacitance level transmitter - electronic preamplifi er

ABB Drives. User s Manual. Modbus Adapter Module RMBA-01

FX-2 Control Board ASY-360-XXX Setup and Configuration Guide

Data sheet GCM MOD GMM EC.1 Communications module Modbus for GMM EC

Chapter. Getting Started. In This Chapter...

Application wireless configuration interface Area lighting Long lifetime and robust protection against moisture,

CA-A480-A Elevator Controller. Reference & Installation Manual

NT PRESSURE TRANSDUCER MODELS 4100, 4210, 4130, 4230

Series ULT Ultrasonic Level Transmitter

USER MANUAL. WBV412U01 AC voltage transducer

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

BNI IOL K023 BNI IOL K023. User s Guide

DATA SHEET IOM 200 analogue interface for AGC 200

MC CO MODBUS ADDRESSABLE SENSOR

Allen-Bradley. User Manual. Stepper Positioning Assembly. (Cat. No QA)

GE Fanuc IC694ALG391. Rx3i PacSystem

WS115 BREAKOUT ADAPTER USER MANUAL

Second Encoder Option Card for PowerFlex 700S Drives with Phase II Control

Table of Contents. General Information. Document Sure-Aire Flow Monitoring System. User and Service Manual WARNING CAUTION

PGR-3200 MANUAL INSULATION MONITOR

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

Chapter. F2-02DA-1, F2-02DA-1L 2-Channel Analog. Current Output. In This Chapter...

SmartBlock I/O Module HE579MIX577/977 Isolated 4/8 Analog Inputs 2/4 Analog Outputs

SoundwebTM. Installation Guide

ABB Drives. User s Manual RS-485 Adapter Board FRSA-00

EL731 PROFIBUS INTERFACE

Signal Doublers. VariTrans A 20300

The information in this chapter will enable you to: Understand the product's basic functions & features

NSD/M1 Installation Instructions

PanelView Plus/VersaView CE Terminals and Display Modules

MasterFlux 48V Cascade BLDC Motor Controller Product Specification 030F0137

LVX Control Unit. Features:

Infosystem Remote Touchscreen Installation Instructions

PRM Integration Guide with Pepperl+Fuchs HiDMUX2700 HART Multiplexer

MR52 READER INTERFACE

Family of Water Cut Analyzers

Zero Volt Monitor Installation, Operation and Maintenance

SoundwebTM. Installation Guide

D-100 FLOW DISPLAY MODBUS Network Interface Installation Guide

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

ACTIONI/Q Q498. DC Powered DC Input Field Configurable Isolator with Math Functions

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

MD3. Microstepping Motor Driver Page 1 of 7. Description. Software. Mechanical Drawing. Features

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

CAN Repeater CAN-CR200, CAN-CR220, CAN-CR210/FO

ICF-1150 Series Quick Installation Guide

F1000 User's Manual. (Version: V1.01)

American Power Design, Inc.

TECHNICAL PRODUCT DATASHEET

Quick Start Guide. 240 Series Cryogenic Sensor Input Module. 1 Model 240 Quick Start Guide

PowerFlex 700S Power Jumpers Frames 1 6

AX200. Installation Guide

ERICSSONZ LBI-38566B MAINTENANCE MANUAL AUDIO BRIDGE MODULE 19D902458G1 TABLE OF CONTENTS

emerge Essential Access Control System

genesis TECHNICAL MANUAL 16-Input Expander Unit GEN-010

205 CPU NETWORK ADAPTER F2-UNICON

Vorne Industries. Model 77/232 Serial Input Numeric 3" Display User's Manual

5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL Fruitland Ave Los Angeles, CA UM Channel Monitor.

SUBCON-PLUS-PROFIB...

MGate 5105-MB-EIP Quick Installation Guide

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions

Installation Instructions

Xitanium. Xitanium LITE Prog LED Xtreme drivers. LED driver. Datasheet. Xi LP 165W A S1 230V C170 sxt

Transcription:

PNEUMERATOR Liquid Level ontrol Systems TMS Series Analog Output Board Installation Instructions Installation For: Model TMS2000 and Model TMS3000 OPYRIGHT 2004 PNEUMERATOR O., IN. TEL: (631) 293-8450 FAX: (631) 293-8533 PNEUMERATOR TEHNIAL SUPPORT 1 (800) 209-7858 Bulletin 139 Rev. D (09/27/07) Page 1 of 5 4/9/2013 12:38:28 PM, 1:1, OPYRIGHT 2013 PNEUMERATOR OMPANY, IN.

PRODUT DESRIPTION: The TMS series analog output board is a plug-in option for both the TMS2000 and TMS3000 Tank Management Systems which provides either six (6) or twelve (12) channels of non-isolated current loop output data, globally selectable for 0-20ma, 0-24ma or ranges. The 0-20ma range is also scaleable for 0-1ma, provided the TMS firmware is at release Vxx.99.91 or later, or version Vxx.00.xx. These outputs can be connected to most programmable logic controllers, building management systems, and similar analog input monitoring devices to provide continuous tank data without the need for communications protocol support. Each current loop channel is field programmable by tank number and data type, including gross volume, net volume, product level, water level and product temperature. If desired, voltage outputs, for example 0-5v, 1-5v or 0-10v can easily be configured using an external resistor. The TMS series analog output board requires no calibration and provides full scale accuracy better than +/-0.05% of full scale. INSTALLATION/SETUP: Before installing the analog output board in your system, be sure TMS power is off, and that you have the correct assembly for your system. Board with Module(s) Board Module Description (1) SET OF TERM. BLOKS (1) MODULE 900497-1 900497-2 900496-1 900496-2 900494-1 (1) 900501-1 TMS2000 6-hannel 900494-2 (2) 900501-1 TMS2000 12-hannel 900489-1 (1) 900501-1 TMS3000 6-hannel 900489-2 (2) 900501-1 TMS3000 12-hannel (2) MODULES 6-HANNELS NOTE: 6-hannel boards have (1) set of terminal blocks and (1) plug-in module. 12-hannel boards have (2) sets of terminal blocks and (2) plug-in modules. (2) SETS OF TERM. BLOKS 12-HANNELS IMPORTANT TMS2000 NOTE: The TMS2000 system main board has two snap-top standoffs which help to align and support the analog board plugged into the expansion card position, as shown in figure below. On some earlier main boards, two additional standoffs were installed, also shown below. Inspect your main board to be sure that these two additional standoffs are NOT present. If they are, consult Pneumercator technical support before proceeding. Failure to do so may damage analog board and void product warranty. Also, DO NOT attempt to remove these standoffs. Improper removal will damage main board and void system warranty. PROEED WITH INSTALLATION ONSULT TEHNIAL SUPPORT (2) ADDITIONAL STANDOFFS PROPER TMS2000 EARLIER TMS2000 PNEUMERATOR TEHNIAL SUPPORT 1 (800) 209-7858 Bulletin 139 Rev. D (09/27/07) Page 2 of 5 4/9/2013 12:38:28 PM, 1:1, OPYRIGHT 2013 PNEUMERATOR OMPANY, IN.

"RUN" and "UPDATE" SHUNT JUMPS PINS 2 and 3 FOR 6-HANNELS DIP SWITH ASSEMBLY 1 SHUNT JUMPS PINS 1 and 2 FOR 12-HANNELS FIGURE 1 TABLE 2 -DIP SWITH SETTINGS OUTPUT RANGE 0-20ma O O 0-24ma O O 0-1ma* O TMS GAIN SELET ** 0.05 0-20ma and 0-1ma SETTING MARKED "" OR 0-24ma EXAMPLE SETTING LOSED SETTING SWITH NUMBERS WHERE: = LOSED, O = * Requires TMS firmware release Vxx.99.91 or later, or version Vxx.00.xx. ** Firmware releases prior to Vxx.99.91 do not support GAIN SELET and instead have a fixed gain of. OUTPUT TMS2000 INSTALL OUTPUT TMS3000 INSTALL OUTPUT OUTPUT FIGURE 2 Referring to figure 1, locate dip switch assembly S1 on analog output board, and set switches 3 and 4 for the desired current loop output range as shown in Table 2. Note that dip switches 1 and 2 must always be set closed for proper operation. Ensure that TMS power is off, then install card as shown in figure 2. onnections to each analog output channel are made to "+", "GND" and "SHD" push-and-load terminals with wire cables no heavier than 20 awg. Although shielded cable is not absolutely required, it is recommended for most applications for best noise immunity. The receiving end shield should be left unterminated. Suggested stranded conductor cable part numbers are Belden 8761 (shielded) and Belden 8442 (non-shielded), or equivalents. Note: Stranded conductors should be tinned to provide reliable connections and easy insertion into terminal blocks. After all wiring is complete, TMS power may be turned on. Observe the two LEDs designated "RUN" and "UPDATE" on the analog output board after power up. Within ten seconds these indicators should begin flashing. The "RUN" LED indicates that the analog board processor is running properly. The "UPDATE" LED indicates that the analog board is communicating with the TMS processor and is receiving new data. The update rate is approximately once per second. Board updating ceases while the user is in the AESS menu mode. Bulletin 139 Rev. D (09/27/07) Page 3 of 5 4/9/2013 12:38:29 PM, 1:1, OPYRIGHT 2013 PNEUMERATOR OMPANY, IN.

PROGRAMMING: Programming each analog output channel is simple and requires only two or three entries. The first selects which tank the data is to be taken from, and the second selects which data to use, gross volume, net volume, product level, water level or product temperature. Programming may be accomplished using the TMS front panel while in the AESS ONFIGURATION menu, or via any of the TMSOMM-supported communications methods. ONFIGURATION PROGRAMMING FOR ANALOG OUTPUT Menu for firmware version Vxx.99.91 or later, or Vxx.00.xx AESS ONFIG SUB ANALOGOUT PGM ITEMS ANALOG EN DATA SEL GAIN ENTRY NO or Tank h. # GRVOL (Gross Volume) NETVOL (Net Volume) PRODHT (Product Height) H2OHT (Water Height) TEMPF* (Product Temperature F) or 0.05 Menu for firmware versions prior to Vxx.99.91 AESS ONFIG SUB 4 TO 20MA PGM ITEMS 4TO20 EN DATA SEL ENTRY NO or Tank h. # GRVOL (Gross Volume) NETVOL (Net Volume) PRODHT (Product Height) H2OHT (Water Height) TEMPF* (Product Temperature F) * TEMP (Product Temperature ) for metric TMS units. OUTPUT DESRIPTION: (ontinues on page 5) Data Modes: Data is scaled as follows: Mode 0-20ma Mode I=((Gross Vol/Tank apacity) x 16ma) + 4ma I=((Net Vol/Tank apacity) x 16ma) + 4ma I=((Product Level/Tank Dia) x 16ma) + 4ma I=((Water Level/Tank Dia) x 16ma) + 4ma I= (((Product Temp + 100)/400) x 16ma) + 4ma I=(Gross Vol/Tank apacity) x 20ma I=(Net Vol/Tank apacity) x 20ma I=(Product Level/Tank Dia) x 20ma I=(Water Level/Tank Dia) x 20ma I= ((Product Temp + 100)/400) x 20ma where I = analog loop current in milliamperes * for metric TMS units - TMS firmware must be Vxx.99.95 or later Bulletin 139 Rev. D (09/27/07) Page 4 of 5 4/9/2013 12:38:31 PM, 1:1, OPYRIGHT 2013 PNEUMERATOR OMPANY, IN.

OUTPUT DESRIPTION ONTINUES: Data Modes: Data is scaled as follows: 0-24ma Mode 0-1ma Mode I=(Gross Vol/Tank apacity) x 24ma I=(Net Vol/Tank apacity) x 24ma I=(Product Level/Tank Dia) x 24ma I=(Water Level/Tank Dia) x 24ma I= ((Product Temp + 100)/400) x 24ma I=(Gross Vol/Tank apacity) x 1ma I=(Net Vol/Tank apacity) x 1ma I=(Product Level/Tank Dia) x 1ma I=(Water Level/Tank Dia) x 1ma I= ((Product Temp + 100)/400) x 1ma where I = analog loop current in milliamperes * for metric TMS units - TMS firmware must be Vxx.99.95 or later NOTE: For vertical or conical tank types, product or water level current loop output is scaled using tank height rather than tank diameter. DEFAULT OUTPUTS: An analog output channel will fail-safe to its full scale current loop value if the associated tank probe fails, or, if the channel is not enabled. VOLTAGE OUTPUT MODE: urrent loop outputs can easily be converted to voltage outputs with the addition of an external resistor. This resistor should be placed at the receiving end, across the signal input and ground terminals. See figure 3 below. Refer to the following table for common voltage ranges and associated resistor values. Voltage Range 1-5V 0-5V 0-10V 0-6V 0-12V R (ohms) 499 499 Mode 4-20MA 0-20MA 0-20MA 0-24MA 0-24MA RESISTOR FIGURE 3 IN GND REEIVING DEVIE Resistor should be rated at 1/2W or higher. Suggested resistor part type is Dale MF-65 or 70 series, or equivalent. If a resistor value other than those shown above is desired, its value must not exceed 800 ohms in order to maintain output loop compliance. Bulletin 139 Rev. D (09/27/07) Page 5 of 5 4/9/2013 12:38:33 PM, 1:1, OPYRIGHT 2013 PNEUMERATOR OMPANY, IN.