CoolMaster Programmers Reference Manual (PRM)

Similar documents
PRELIMINARY. CoolMasterNet PRM. CoolMasterNet Universal Interface Adapter for HVAC Systems. Document Revision /11/2014

CooLinkHub PRM. CooLinkHub Universal Interface Adapter for HVAC Split Systems. Document Revision /09/2017

CooLinkNet CooLinkNet PRM CooLinkNet Universal Interface Adapter for HVAC Split Systems

CoolMasterNet CooLinkNet CooLinkHub CooLinkBridge. BACnet Integration Guidelines. BACnet Integration Guidelines

MM-A20 BMS Interface for Mitsubishi Electric Split Air-Conditioning

USER MANUAL FOR GS100/GS1003G

+ (5~27 VDC) GND. Bluetooth V4.1 BLE RS-232 Serial Adapter. Model: BLE-232B. 1. Package content: BLE RS-232 adapter

LM058 Bluetooth Serial Adapter

+ (5~27 VDC) GND. Bluetooth V4.2 BLE RS-232 Serial Adapter. Model: BLE-232D-E. 1. Package content: BLE RS-232 adapter

Serial Bluetooth Smart Adapter - RS232, Low Energy 4.2 BLE Datasheet and Quick Reference for USBLE232C

Bluetooth RS232 Serial Adapter

CoolMasterNet CooLinkNet. HDL Integration Guidelines. HDL Integration Guidelines

Doug Fleenor Design, Inc. RS-232 to DMX512 Interface, 2 Generation. March 8, 2010 (Software V1.2)

Serial Bluetooth Smart Adapter - RS232, Low Energy 4.1 BLE Datasheet and Quick Reference for BLE232V2

RFID MODULE Mifare Read/Write Module SL025B User Manual Version 1.1 Jun 2010 StrongLink

Installation and operation manual ReciFlow Gas

Setting Up Your Cisco Unified Videoconferencing 3515 MCU

Updating Reader Firmware

Manual. Specifications. Contents. Options

1450 First Ave. Page 1 of 11 Chippewa Falls, WI (800) or (715) Fax: (715)

Before powering on your driver, read this manual thoroughly. If you have any doubt or suggestion, please do not hesitate to contact us!

TEC-BT temperature controller User manual

INDEX. Document Name : User Manual for SC10EJ Serial to Ethernet Converter

Manual DTM Digital Pressure Transmitter

ThermoPad Reference Manual

Operating Instructions. Controller for Automatic Mass Comparators from Software Version 1.22 for CC...- L / CCE...- L Model

B-100 / B-300 Series HDMatrix Switchers

Manual 601: : USB/RS232. Specifications. Contents. Options

MXM-50. Modbus Interface for Mitsubishi Air-Conditioning. Installation and User Guide.

3.1 I-7560 Pin Assignment and Specifications: Introduction

Configuring the Switch

ETH-4X1-G / 2X1-G / 2X1

Configuring the Switch

Temperature-Humidity Sensor Configuration Tool Rev. A 1/25/

Industrial Serial Device Server

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

LD6015. Datasheet & Manual. 1. Features. 3. Description. 2. Applications. 4. Absolute maximum ratings* 5. Recommended operating conditions

W8735A1013 EnviraCOM Serial Adapter

Thermoelectric Cooler Controller TED1000

15693-RW-TTL-PCB1 CONTENT 1. MAIN FEATURES PINNING INFORMATION BAUD RATE SETTING COMMUNICATION PROTOCOL...5

AMT203 ABSOLUTE ENCODER Demo Kit User Guide DISCONTINUED

Installation Instructions. Procon IP-32M wir-1_ MITSUBISHI ELECTRIC

Flex Series User Guide

ZM56 High-Speed Industrial Modem. Command Summary. 1 ZM56 High-Speed Industrial Modem

BMV Text Protocol. Table of contents

RS-232/422/485 to Copper or Fiber. Ethernet Converter. User s Manual

Integrity Instruments

Installing the Cisco Unified Videoconferencing 3545 MCU

SeriBox. antrax Datentechnik GmbH

Serial Bluetooth Smart Adapter - RS232, Low Energy 4.2 BLE Datasheet and Quick Reference for USBLE232DEXA

BV4109. Serial LCD Controller. Product specification November ByVac 2006 ByVac Page 1 of 12

Installation Manual. DZK BACnet

BMS Interface for Panasonic Air-Conditioning

Before powering on your driver, read this manual thoroughly. If you have any doubt or suggestion, please do not hesitate to contact us!

V0STAT51P-2 Programmable Wired Controller

Setting Up Your Cisco Unified Videoconferencing 3500 Gateway

PowerView. Hub. by LUXAFLEX WINDOW FASHIONs

BV4531U. I2C or Serial 6 Way Relay

ZM24x Quick-Connect Industrial Modem. User s Manual

UPDATING THE FIRMWARE IN FRAME BASED MODULES...

OPERATING MANUAL AND TECHNICAL REFERENCE

RTD-RA. realtime. Installation Instructions. English A B. Installation Instructions Control Systems LEDS ALL DIMENSIONS IN MM

USER MANUAL HPS-120. About this product: Your Communications Solutions Provider

DSP Terminal V1.5.7 Users Guide

PACSystems* RX3i IC695CMM002 and IC695CMM004

Procon BAC-A/50. Installation Instructions MITSUBISHI ELECTRIC

Chapter. Modbus. In This Chapter...

LM058 Bluetooth Serial Adapter SMA Antenna 100m m Range SPP GAP + Wireless DTR DSR RTS CTS

PACSystems* RX3i IC695CMM002 and IC695CMM004

RFID MODULE Mifare Reader / Writer SL031 User Manual Version 3.0 Jan 2018 StrongLink

Modbus Server - Mitsubishi Electric G50

2001 by NEC America. All Rights Reserved. Printed in U.S.A.

NOTE CONTENTS NOTE-CONTENTS

MF1-RW-TTL-PCB Mhz Mifare ISO14443A reader/writer module with TTL interface CONTENT 1. MAIN FEATURES...,, PINNING INFORMATION...

KNX is a European Standard Protocol used for household and industrial Buliding Management System (BMS).

PACSystems* RX3i IC695CMM002-EG and IC695CMM002CA-EG IC695CMM004-EG, IC695CMM004CA-EG, and IC695CMM004LT-EG

Flash Magic Application Note 4 What to do if ISP Does Not Work Embedded Systems Academy 2003, All Rights Reserved

SERVICE INSTRUCTION. Updating the firmware and software on the RCS-2

The I-7530A-MR Modbus RTU to CAN Converter

LM048 Bluetooth v2.0, v2.1 RS232 Serial Adapter Standalone (With Embedded Bluetooth v2.0 / v2.1 Stack)

LM058 Bluetooth v2.0, v2.1 RS232 Serial Adapter - SMA Connector Standalone (With Embedded Bluetooth v2.0 / v2.1 Stack)

T1DP 0v High Voltage Desk Top Power Supply. Operators Manual

Integration Note OVERVIEW AND SUPPORTED FEATURES

PROJECTOR MODEL SETUP MANUAL

Operating Instructions. Sartorius. Description of the Interface for EA, EB, GD, GE and TE Balances/Scales

I/O Interface DNA300

DWP-98 Series. Counting scale. User s Guide PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE ATTEMPT TO OPERATE THE INSTRUMENT

RTD-NET Installation Instructions

Installation and User Guide

MX200 SERIES Modbus Card 50P GE Zenith Controls. Operation and Maintenance Manual 50R-2200B 12/00

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL

B-520-MTRX-230 HDBaseT Matrix Switchers

epowerswitch-8 Power Management Master Slave User's Guide

User Manual A08. User Manual

Bluetooth V4.1 BLE RS-232 Serial Adapter Model: BLE-232B Bluetooth V4.2 BLE RS-232 Serial Adapter Model: BLE-232C

Unpacking an Epica Distribution Matrix

REMOTE CONTROLLER CS244-R OWNER S MANUAL

Datapanel. VT100 Terminal Emulator for Datapanels. Operator Interface Products. User's Manual

VS-626M5 Parameter Upload/Download Software User s Manual (Preliminary) 5/18/99

LDV Communications Specification

Transcription:

CoolMaster Programmers Reference Manual (PRM) CoolMaster Interface Adapter for VRV, VRF Air Conditioning Systems Cool Master 1000D Cool Master 2000S Cool Master 3000T Cool Master 4000M Version 3.0 8/12/2009

CoolMaster PRM Contents 2 Table of Contents Foreword 0 Part I RS232 Interface 3 1 Mechanical and... Electrical Specification 3 2 Port Settings... 4 Part II General Protocol Definitions 5 1 Message format... 5 2 Indoor Unit Addressing... 5 Part III Commands Reference 7 1 Cool Master Commands... 7 alloff allon boot cool dry heat fan filt fspeed off on set simul stat stat2 stat3 swing temp... 7... 7... 8... 8... 8... 9... 9... 10... 10... 10... 11... 11... 12... 13... 13... 14... 15... 16 Part IV Firmware Update 17 1 Entering bootloader... mode 17 2 Firmware Download... 17 3 Reboot... 18 2

RS232 Interface 3 1 RS232 Interface 1.1 Mechanical and Electrical Specification RS232 Interface connector used in Cool Master is D-Type 9-pin DB9 female connector. Cool Master DB9 Connector front view DB9 Pin Signal Lvel Description 2 ±12V TxD (Data from Cool Master) 3 ±12V RxD (Data to Cool Master) 5 GND Ground Connecting Cool Master to Home Automation Equipment According to RS232 specification cable length should not exceed 25m. RS232 Cable supplied with Cool Master is 1.5m length suitable for direct connection to PC RS232 serial port.

RS232 Interface 4 1.2 Port Settings For proper communication with Cool Master RS232 Port should be configured with following parameters Baud Rate 9600 Data Bits 8 Parity Control None Stop Bits 1 Flow Control None Below is an example of COM port setup in HyperTerminal application

General Protocol Definitions 5 2 General Protocol Definitions 2.1 Message format Communication between PC or Home Automation Controller and CoolMaster via RS232 interface is based on text messages. Communication example is shown below >stat 101 command PC to CoolMaster 101 ON 27C 00,00C Auto Dry response exit code CoolMaster to PC > prompt Command message sent to CoolMaster must be terminated by CR (carriage return 0x0D) LF (line feed 0x0A) sequence or a single CR character. Messages from CoolMaster (except prompt character) are terminated by CR LF. Commands are case sensitive and should not contain leading or trailing spaces. The only separator between command name and command parameter(s) is space character. In case of wrong command CoolMaster response can be one of the following strings: Unknown command Bad parameters Unrecognized command name Command has missing or wrong parameters If command was executed CoolMaster will return optional response and exit code. Detailed information is provided in topics describing specific commands. 2.2 Indoor Unit Addressing To address specific indoor unit in CoolMaster command the UID parameter is used. UID format is three digits. First digit can be hexadecimal in range 1-9 or A-F to represent system numbers 1 to 15 correspondingly. 1 2 3 System Number Unit Number in System 0-9, A-F 00-99 For CoolMaster 4000M System Number must be 0, Unit Number must be 01-50 For CoolMaster 1000D System Number must be in range 1-4 For CoolMaster 2000S and 3000T System Number should not be 0 UID reflects the indoor unit Centralized Address. For proper operation of Cool Master all indoor units have to be given Centralized Address (depending on specific AC system type this can be done automatically by system or has to be done manually by integrator). You should refer to specific AC system manuals to find out how to set and quire Centralized Addresses. Below are examples of accepted UID's. UID Centralized Address 100 1-00 101 1-01 201 2-01 310 3-10 F99 15-99

General Protocol Definitions 6 Note: For backward compatibility Unit number in System can be represented by hexadecimal numbers couple in range 00-0F equal to decimal 00-15. For example 10A represents Centralized Address 1-15. We recommend not to use this option in future designs.

Commands Reference 7 3 Commands Reference 3.1 Cool Master Commands 3.1.1 alloff Enter topic text here. alloff Turn off all indoor units >alloff 3.1.2 allon allon Turn on all indoor units. >allon

Commands Reference 8 3.1.3 boot boot Switch CoolMaster to bootloader mode. Bootloader mode is used for Firmware Update. For details please see the Firmware Update section. >boot reboot... 3.1.4 cool cool <UID> Set indoor unit UID mode to COOL. >cool 102 3.1.5 dry dry <UID> Set indoor unit UID mode to DRY. >dry 102

Commands Reference 9 3.1.6 heat heat <UID> Set indoor unit UID mode to HEAT. >heat 102 3.1.7 fan fan <UID> Set indoor unit UID mode to FAN. >fan 102

Commands Reference 10 3.1.8 filt filt <UID> Reset filter sign on indoor unit UID. >filt 102 CoolMaster 1000D v 0.3.1 3.1.9 fspeed fspeed <UID> <l m h a> Set indoor unit UID fan speed to low, medium, high, auto. >fspeed 101 l >fspeed 101 m >fspeed 101 h >fspeed 101 a Set unit 1-01 fan speed to low Set unit 1-01 fan speed to medium Set unit 1-01 fan speed to high Set unit 1-01 fan speed to auto 3.1.10 off Only l and h options supported offl <UID>

Commands Reference 11 Turn off indoor unit UID. >off 102 3.1.11 on on <UID> Turn on indoor unit UID. >on 102 3.1.12 set set [<option> <value>] Query or set CoolMaster configuration. Without parameters set command will list all supported configuration options and their values. To change option use format with option and value. Some options are read only and can not be changed. Configuration Access Description Option Mode S/N Read CoolMaster Unit Serial Number myid R/W CoolMaster Unit own Centralized Address

Commands Reference 12 version Read Firmware Version echo R/W 0-Disable 1-Enable Commands echo lcd R/W LCD size simul R/W Number of Indoor units permanently simulated. If simul is not zero CoolMaster will simulate given number of units after reset. CS count Read Check Sum errors counter TO count Read Timeout errors counter S/N : 0041 myid : 0A version : 2.1.4 echo : 1 lcd : 8 simul : 0 CS count: 0 TO count: 0 >set echo 0 Query configuration Set echo option (disable echo) 3.1.13 simul simul <N> Simulate N indoor units. Simulation mode can be used to debug Home Automation Controller software without connecting CoolMaster to Air Conditioning system line. To exit simulation mode set N to zero or restart CoolMaster. >simul 20 >simul 0 Simulate 20 Indoor Units Terminate simulation mode

Commands Reference 13 3.1.14 stat stat [UID] Get Indoor unit(s) status. Specific indoor unit can be addressed by UID. If no UID provided in request, response will contain information about all units >stat 100 ON 12C 12,41C High Cool 101 OFF 32C 04,93C Low Dry 102 ON 07C 08,27C High Dry 103 OFF 01C 26,84C Med Dry 104 ON 04C 24,08C High Dry 105 OFF 11C 07,23C Low Dry 106 ON 11C 14,91C Auto Dry 107 ON 27C 12,94C Med Cool >stat 101 101 OFF 32C 04,93C Low Dry RESPONSE Position in String Example Format Description 0-2 109 NNN Indoor unit Centralized Address 4-6 ON ON or OFF On/Off Status 8-10 23C NNC Set Temperature ºC 12-17 24,08C NN,NNC Room Temperature ºC 20-23 Auto Low or Med or High or Auto Fan Speed 25-28 Cool Cool or Heat or Fan or Dry Operation Mode 30-32 or XN or Failure code 3.1.15 stat2 CoolMaster 1000D v 0.0.1 This command is obsolete and is supported only for backward compatibility. stat2 [UID] Get Indoor unit(s) status. Specific indoor unit can be addressed by UID. If no UID provided in request, response will contain information about all units. stat2 compared to stat1 has additional Filter Reset Sign indication

Commands Reference 14 >stat2 100 ON 12C 12,41C High Cool 0 101 OFF 32C 04,93C Low Dry 1 102 ON 07C 08,27C High Dry 0 103 OFF 01C 26,84C Med Dry 0 104 ON 04C 24,08C High Dry 0 105 OFF 11C 07,23C Low Dry 0 106 ON 11C 14,91C Auto Dry 0 107 ON 27C 12,94C Med Cool 1 >stat2 101 101 OFF 32C 04,93C Low Dry 0 RESPONSE Position in String Example Format Description 0-2 109 NNN Indoor unit Centralized Address 4-6 ON ON or OFF On/Off Status 8-10 23C NNC Set Temperature ºC 12-17 24,08C NN,NNC Room Temperature ºC 20-23 Auto Low or Med or High or Auto Fan Speed 25-28 Cool Cool or Heat or Fan or Dry Operation Mode 30-32 or XN or Failure code 34 0 0 or 1 Filter Reset Sign present CoolMaster 1000D v 0.3.1 3.1.16 stat3 stat3 [UID] Get Indoor unit(s) status. Specific indoor unit can be addressed by UID. If no UID provided in request, response will contain information about all units. stat3 compared to stat2 has no fractional part in the room temperature presentation. >stat3 100 ON 12C 12C High Cool 0 101 OFF 32C 04C Low Dry 1 102 ON 07C 08C High Dry 0 103 OFF 01C 26C Med Dry 0 104 ON 04C 24C High Dry 0

Commands Reference 15 105 OFF 11C 07C Low Dry 0 106 ON 11C 14C Auto Dry 0 107 ON 27C 12C Med Cool 1 >stat3 101 101 OFF 32C 04C Low Dry 0 RESPONSE Position in String Example Format Description 0-2 109 NNN Indoor unit Centralized Address 4-6 ON ON or OFF On/Off Status 8-10 23C NNC Set Temperature ºC 12-14 24C NNC Room Temperature ºC 16-19 Auto Low or Med or High or Auto Fan Speed 21-24 Cool Cool or Heat or Fan or Dry Operation Mode 26-27 or XN or Failure code 29 0 0 or 1 Filter Reset Sign present CoolMaster 1000D v 2.0.9 3.1.17 swing swing <UID> <a h 3 4 6 v> Set indoor unit <UID> swing to auto, horizontal, 30º, 45º, 60º or vertical. Not all indoor unit types support swing. >swing 101 a >swing 101 h >swing 101 3 >swing 101 4 >swing 101 6 >swing 101 v Set unit 1-01 swing to auto Set unit 1-01 swing to horizontal Set unit 1-01 swing to 30º Set unit 1-01 swing to 45º Set unit 1-01 swing to 60º Set unit 1-01 swing to vertical

Commands Reference 16 CoolMaster 1000D N.A. CoolMaster 2000S v2.3.1 CoolMaster 3000T v2.3.1 CoolMaster 4000M v2.3.1 3.1.18 temp temp <UID> [±]<TEMPERATURE> Set indoor unit temperature. <TEMPERATURE> parameter must be decimal number. Command can work in relative or absolute manner. If plus '+' or minus '-' sign precede <TEMPERATURE> parameter it's value will be used as requested delta. It means the set temperature will be increased (+) or decreased (-) to that delta. Otherwise temperature will be set to the given value. >temp 101 20 >temp 101-1 >temp 101 +3 Set unit 1-01 temperature to 20ºC Decrease unit 1-01 temperature by 1ºC Increase unit 1-01 temperature by 3ºC CoolMaster 1000D v 2.0.9

Firmware Update 17 4 Firmware Update 4.1 Entering bootloader mode The process of updating CoolMatser's firmware is very simple and straightforward. First of all CoolMaster has be switched into bootloader mode. In order to do so, please connect your PC (Laptop) to the RS232 port of the CoolMaster. Next open the Hyper Terminal program and run boot command. This process is described in "User Manual" document. At this point "BOOT" message should appear on the LCD screen of the CoolMaster. Now it is ready for firmware uploading. Please close Hyper Terminal program and follow to the next step - Firmware Download. If for some reason CoolMaster is not responding to boot command or preceding firmware update has failed and CoolMaster is not functioning at all, follow the next steps in order to enter bootloader mode. Step1 Step2 Disconnect power supply from the CoolMaster Open CoolMaster top cover Step3 Open BOOT jumper shown on the diagram Step4 Connect power supply to CoolMaster 4.2 Firmware Download Firmware update is supplied as a set of BAT file(s) and firmware image(s). BAT file can be for example progp-daikin.bat and corresponding image file DAIKIN.INC. Make sure that BAT file and the image file are located in same directory. In order to start the process, please simply run the BAT file. After running BAT file, the ComPort selection prompt will appear and the correct port number should be entered in order to proceed.

Firmware Update 18 CoolMaster will react with running address counter on its LCD screen. The whole process may take about a few minutes, and it ends with "EOF" and shortly afterwards "READY" messages on the LCD screen. 4.3 Reboot After firmware downloading has being finished you need to power reset CoolMaster. If it was entered bootloader mode with BOOT jumper, please make sure to close BOOT jumper back before power reset.

Index 19 Index - A - AirNet 14 - B - boot 8 - C - cool 7, 8 - D - dry 8 - F - fan 9, 10 filt 10 Filter Sign 10, 13, 14 - H - heat 9 - O - off 10 on 11 - S - set 11 simul 12 stat 13 stat2 13 stat3 14 swing 15