Automated Tuner System Power Distribution Hub

Similar documents
Precision N Coaxial Calibration Kit

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

87421/22A Power Supply. Operating and Service Manual

iconverter 2-Module Power Chassis

Agilent Technologies E5339A 38-Pin Low-Voltage Probe

Quick Start/Installation Guide

PIM-Mini Pulsed Current Source Operation Manual

Zonit μats TM Users Guide μats1-lv Version 1.2

User's Guide. Extech AM A AC Analog Clamp Meter

User's Guide. MiniTec TM Series Model MN25 MultiMeter

User's Guide. Phase Sequence and Motor Rotation Tester Model

CrystalView DVI Multi INSTALLATION AND OPERATIONS MANUAL Stancliff Road Phone: (281)

Contents. HP E1586A Rack Mount Terminal Panel User s Manual

Installation and Operations Manual

MONITOR Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

User Guide. Control Box. RoscoLED TM.

User s Guide. 600A AC Clamp Meter. Model 38387

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

SATA II HDD Canister KISS DA 435 Quick Reference Guide

OPERATING PROCEDURES for the UPS-S2 Universal Power Supply Series 2

Agilent 70612B K18 Switch Matrix

PCM-7140 Pulsed Current Source Operation Manual

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

MTS-2000 USER S MANUAL

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

Mini Digital Multimeter

TETRIS 2500 High Impedance Active Probe. Instruction Manual

USB Ranger 110/410 User Guide

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

AC4G-D User s Manual

±15 V Current-Limited Power Supply

User s Guide. POWERVAR Single Phase Power Conditioners

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A

ANT CNTR DC ALRM LNB RX DC ALRM +18V OFF

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch

USB Ranger Fiber Optic USB 2.0 Extender. User Guide

KHT 6000 C HV-Probe Calibrator. Instruction Manual

USB 2.0 Ranger Port USB m CAT 5e/6/7 Extender System. User Guide

ODTF-1 Optical Distance-to-Fault Module

Broadband Automatic Disconnect Switch. User Manual

Sonic Ruptor 400. User Manual

20W Tungsten-Halogen Light Source. Operation Manual

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only.

ACLD Channel Opto-isolated Digital Input Board

IAQ-CALC TM Indoor Air Quality Meter

Keysight 42941A Impedance Probe Kit

ETConcept Systems Engineering. User s Guide

USB Ranger 422 User Guide

TD 600 Thermo-Fastprinter

MFA-0801 & MFA-1201 D-M-E Smart Series Low Voltage Temperature Control System. User s Manual. D-M-E Company

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

USB Audio Converter. Installation and Operation Manual. USB to Analog Audio Converter Stancliff Road Houston, Texas 77099

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

User s Manual Legend SB425 K

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7525

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage

USB 3.0 Spectra Port USB m Multimode Fiber Extender System. User Guide

Instruction and Operation Manual. CRMS Contact Resistance Measurement System. Model Number Caution!

Power Quality Recorder

USB Ranger User Guide. Cat 5 USB 2.0 Extender with Remote Power. Powered by

Economy Single Channel Output DC Power Supply

Firmware Updates Model 24 / 44 / 42 Cryogenic Temperature Controllers

OPERATING MANUAL LOW-VOLTAGE DISCONNECT PANELS LVD400 & LVD600 SERIES

Rack Power Distribution Unit AP7530, AP7540

9040/9040UK. Users Manual. Phase Rotation Indicator

PD10. Pulse Divider Instructions PROUDLY MADE IN THE USA

USB 3.0 Spectra

PCMCIA Flash Card User Guide

TCP305A & TCP312A AC/DC Current Probes Instructions

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module

1-36V, 0-3A DC Power Supply

Line Impedance Stabilization Network (LISN)

CV-24D. Stereo to SPDIF Converter with Adjustable Audio Delay. User Manual. Made in Taiwan

USB 2.0 Ranger Port USB m Cat 5e Extender System. User Guide

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

MCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

EPS Power Supply

S82S (3/7.5-W Models)

USER MANUAL CCHP-6000-XX 6kJ/s Capacitor Charging Power Supply

OL-KT. Online Connection Kit Installation Manual

* * Agilent Power Distribution Unit (PDU) Installation Guide

INSTRUCTION MANUAL. Instruction Manual. Analog Multi-Tube Vortexer Digital Multi-Tube Vortexer

Interface Modules for HP Series Instruments. I/O Function Guide. Copyright Hewlett-Packard Company All rights reserved

Automation for Research and Industry. Robotic Shaker

FOR LT-DPLS401. Document No.: A-A Creation: Sep 28, 2010 Revision: 01, Sep 28, 2010

Agilent Technologies LogicWave

ipad Charge & Sync Cart Model MCC2 ipad Cart 430-MCC2-User Manual-010 Is a Registered Trademark of Apple Inc. ipad

Warner Instruments 1125 Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

CiM-25. Quick Start Guide. IP-Enabled M&C Part Number CD/CIM25QSG.IOM Rev. 0

General Warranty. For more details, please refer to the user manual on the supplied CD, it can also be downloaded at

HP E2485A. Installation Guide. Memory Expansion Interface. Copyright Hewlett-Packard Company 1997 All Rights Reserved

Table of Contents. 3.1 Front/Rear Panel and User Interface Front Panel Rear Panel User Interface...

User's Guide. Model High Precision Quad Output DC Power Supply

LBC-PSW52. Link Bridge TM Presentation Scaling Switch with 5 Inputs and Two Mirrored Outputs

User Guide. USB/Ethernet Charging Cradle. Mobility Electronics, Inc Via Pasar, San Diego, CA 92126, USA

IAQ-CALC TM Indoor Air Quality Meter

THECHARGEHUB.COM. User Manual. For Square & Round Models

E-Tool Mobile Manager 6 Drawer Rugged Managed (Rev. 0)

Transcription:

User Guide Automated Tuner System Power Distribution Hub Model MT1020B MT1020-340 (Rev B) 12/11

User Guide Automated Tuner System Power Distribution Hub Model MT1020B 2900 Inland Empire Boulevard Ontario, California 91764-4804 USA Phone: (909) 987-4715 Facsimile: (909) 987-1112 maurymw.com MT1020-340 (Rev B) 12/11 Copyright 2011 Maury Microwave Corporation. All rights reserved.

Warranty Maury Microwave hardware products are warranted against defects in materials and workmanship for a period of one year from date of shipment. During the warranty period, Maury Microwave will, at its option, either repair or replace products which prove to be defective. Maury Microwave software products are warranted against defects in material and workmanship of the media on which the product is supplied for a period of ninety (90) days from date of shipment. Maury also warrants that the product shall operate substantially in accordance with published specifications during the same warranty period. During the warranty period, Maury Microwave will, at its option, either repair or replace products which prove to be defective. Maury does not warrant that the operation of the product shall be uninterrupted or error-free. For warranty service or repair, all products must be returned to Maury Microwave and must be issued a return authorization number by Maury prior to shipment. Buyer shall prepay shipping charges to Maury. Obligation is limited to the original Buyer. Limitation of Warranty The foregoing warranty shall not apply to defects resulting from improper or inadequate maintenance by the Buyer, unauthorized modification or misuse, operation outside of the environmental specifications for the product, or wear resulting from normal use. No other warranty is expressed or implied. Maury Microwave specifically disclaims the implied warranties of merchantability and fitness for a particular purpose. The remedies provided herein are the Buyer s sole and exclusive remedies. Maury Microwave shall not be liable for any direct, indirect, special, incidental, or consequential damages whatsoever (including, without limitation, damages for loss of business profits, business interruption, loss of business information, or any other financial loss) arising out of the Buyer s use of or inability to use the product, even if Maury or an authorized Maury dealer has been advised of the possibility of such damages.

Contents General Information... 1 MT1020B Automated Tuner System Power Distribution Hub... 1 Specifications... 1 Accessories Supplied... 1 Installation... 3 Power Requirements... 3 Ground Requirements... 3 Operational Temperature and Humidity... 3 Connecting the Devices... 3 Operation... 4 Connectors, Controls and Indicators... 4 Appendix... 5 Shipping Package... 5 Data Sheet Resources... 6 Attachment (located behind Appendix) Form No. 278A-12, Declaration of Conformity MT1020-340 (Rev B) 12/11 i

Tables Table 1. Safety Symbol Definitions...2 Figures Figure 1. Power Entry Module with Fuse Holder...3 Figure 2. Front Panel...4 Figure 3. Rear Panel...4 Figure A 1. Packaging Kit...5 ii MT1020-340 (Rev B) 12/11

General Information MT1020B Automated Tuner System Power Distribution Hub The MT1020B Automated Tuner System Power Distribution Hub is designed to provide power and interface control for the Maury USB series of automated mechanical tuners. As many as four units may be controlled through this device. Connection to the host computer is made via a standard USB interface. Specifications USB Interface... USB 1.1 and USB 2.0 compatible Power Requirements... 100 to 264 VAC @ 47 to 63 Hz, 3 Amps Mains supply voltage fluctuations not exceeding ±10% of the nominal voltage. Transient over voltages according to over voltage category II Output Power... +5 VDC @ 5 Amps +24 VDC @ 3.4 Amps USB Power... +5 VDC @ 500 ma per port Environmental... Indoor use only Relative humidity, 90% non-condensing Altitude up to 2000 meters Pollution degree 2 Accessories Supplied Qty Part No. Description 1 499-F-173-21 Spare fuse (5x20 mm, 3.1 A, slow-blow) 1 499-C-722 USB cable assembly 1 499-C-082 Power cord for 115 VAC (USA) or 499-C-469 Power cord for 230 VAC (Europe, CE certified) or 499-C-718 Power cord (China, CCC certified) MT1020-340 (Rev B) 12/11 1

Table 1. Safety Symbol Definitions 2 MT1020-340 (Rev B) 12/11

Installation Power Requirements The model MT1020B power distribution hub contains an internal universal switching supply which requires input power of single phase 100 to 264 VAC at 47 to 63 Hz. The unit contains a four port USB 2.0 hub and a power entry module consisting of a power cord receptacle and fuse holder (see Figure 1). The fuse holder contains a 5x20 mm, 250 VAC, 3.15 A, slow-blow fuse. Ground Requirements Figure 1. Power Entry Module with Fuse Holder To minimize shock hazard, the instrument chassis must be connected to an electrical protective earth ground. The instrument must be connected to the AC mains through a grounded power cable, with the ground wire firmly connected to an electrical ground at the power outlet. Any interruption of the protective (grounding) conductor or disconnection of the protective earth ground will cause a potential shock hazard that could result in personal injury. Operational Temperature and Humidity The MT1020B ATS Power Distribution Hub is designed to operate within the specified performance limits over a temperature range extending from 0 to 50 C (-32 to 122 F) and operate at a maximum (non-condensing) relative humidity of 90% (measured at the fan intake). The fan located on the rear panel assembly cools the instrument by drawing air through the bottom of the instrument case, and exhausting air through the fan opening on the rear panel. Operating the instrument outside the temperature range for extended periods will result in degradation of electrical performance and eventual malfunction. NOTE: Because the MT1020B is fan cooled, it must be installed in a location that allows sufficient (nonrestricted) space below the instrument case for adequate circulation of air. Connecting the Devices The MT1020B Power Distribution Hub is designed to interface with all Maury USB controlled automated mechanical tuners. The cable assembly required to interface with each tuner is provided with the instrument when shipped from the factory. MT1020-340 (Rev B) 12/11 3

Operation WARNING: Always set the MT1020B power switch to the OFF position before installing or removing the combination USB/Power cable assembly to prevent possible damage to the instrument. Set the power switch to the OFF position. Inspect each connector on the tuner, controller and cable assembly to ensure that all connections are clean and undamaged. Align the cable connectors with the tuner and controller connectors and attach. Verify that all connectors are fully engaged before continuing. Install a USB cable assembly between the host computer and the MT1020B Power Distribution Hub. Set the MT1020B power switch to the ON position. To be fully functional, the Power Distribution Hub requires at least one attached USB instrument.. The 4 port USB hub is a standard USB 2.0 hub assembly and will be detected by the computer s Windows operating system. Operation of the USB tuners will be controlled using Maury ATS software version 4.00 or later. No software is required for operation of the MT1020B Power Distribution Hub itself. Connectors, Controls and Indicators Figures 2 and Figure 3 identify the front and rear panel connectors, controls and indicators. 2 1 3 Figure 2. Front Panel 1. Line power switch 2. Power ON indicator 3. Power and USB connectors 6 5 4 Figure 3. Rear Panel 4. AC power entry module 5. Fuse holder (part of power entry module) 6. USB input connector 4 MT1020-340 (Rev B) 12/11

Appendix Shipping Package If it becomes necessary to return the MT1020B ATS Power Distribution Hub to the factory for warranty, repair or maintenance, it is important to protect the unit during transit. To insure this, use of the original packaging materials is suggested. If you do not have the original packaging materials, contact your Maury representative or the factory and a packaging kit will be provided. The instructions provided below will properly prepare the unit for return to the factory. Package the MT1020B ATS Power Distribution Hub using the original carton and foam pads supplied with the unit as shown in Figure A1. Seal carton seams using minimum 2 inch (5 cm) wide adhesive tape. After the unit is packaged into the primary carton and sealed, then package this carton inside a larger carton, properly dunnaged, to prevent shipping damage. Figure A 1. Packaging Kit MT1020-340 (Rev B) 12/11 5

Data Sheet Resources 4T-068 Automated Tuner System Power Distribution Hubs http://www.maurymw.com/pdf/applib/4t-068.pdf 4T-050F Automated Tuner System http://www.maurymw.com/pdf/applib/4t-050f.pdf 4T-056 Automated Tuners (0.25 to 8 GHz) http://www.maurymw.com/pdf/applib/4t-056.pdf 4T-072 7mm Automated Tuners (0.8 to 18 GHz) http://www.maurymw.com/pdf/applib/4t-072.pdf 4T-065 2.4mm Automated Tuners (8.0 to 50 GHz) http://www.maurymw.com/pdf/applib/4t-065.pdf 4T-074 Millimeter-Wave Automated Tuners (33 to 110 GHz) http://www.maurymw.com/pdf/applib/4t-074.pdf 4T-076 Automated Sliding Shorts (0.4 to 18 GHz) http://www.maurymw.com/pdf/applib/4t-076.pdf 6 MT1020-340 (Rev B) 12/11

Contacts Corporate Maury Microwave Corporation 2900 Inland Empire Boulevard Ontario, California 91764-4804 United States of America Tel 909-987-4715 Fax 909-987-5855 email maury@maurymw.com Sales Tel 909-204-3224 Fax 909-987-1112 email maury@maurymw.com Customer Support Tel 909-204-3283 Fax 909-987-1112 email support@maurymw.com Web Site http://maurymw.com Web Resources Visit our web site for additional product information and literature. Maury Calibration Kits http://maurymw.com/precision/vna_cal_kits.php Maury Precision Coaxial and Waveguide-to-Coaxial Adapters http://maurymw.com/finder/adapter_finder.php Maury Applications Notes Library & Technical Articles Archive http://maurymw.com/support/tech-support.php Maury Sales Representative Finder http://maurymw.com/support/find-sales-rep.php