Flow Cytometry & FACS Core Facility

Similar documents
FACSLyric TM General User instructions

BD FACSDiva Software Quick Reference Guide for BD FACSCanto Systems with Loader Option

FACSLSRFortessa SORP QUICK REFERENCE GUIDE

Setup protocol for Firefly particles. On BD FACSCanto cytometers with single tube loader function

LSRFortessa Guide. Cell Evaluation and Therapy Core HO324

UNC Flow Cytometry Core Facility LSR II Operation 2018

Canto II Operation Protocol

BD Influx Standard Operation Protocol - Basic Operation

Setup protocol for Firefly particles. On BD LSR II and LSRFortessa cytometers with single tube loader function

Unscrew and remove the cap from the waste tank

FACSAria Fusion SORP QUICK REFERENCE GUIDE

BD Accuri C6 with single tube loader protocol. For multiplex assays

BD FACSMelody Cell Sorter Quick Reference Guide

CyAn ADP Guide. Starting Up

SPA III Quick Reference Guide for Custom Panels

FACCalibur Users Guide

BD High Throughput Sampler User s Guide

JMJ-Group Microbiology BMB SDU

NovoExpress Software Guide. Software Version 1.2.4

BD CellQuest Pro Software Acquisition Tutorial

Release Notes Life Technologies Attune NxT Cytometric Software v 2.0.0

Standard Operating Procedure For: Independent End User Training and Maintaining Optimal Instrument Performance:

STANDARD OPERATING PROCEDURE FOR THE LSR II

Applied Biosystems Attune Cytometric Software version 1.2 Release Notes

Tutorial: FCAP Array Software with BD FACSArray Bioanalyzer

USER GUIDE TO BECKMAN COULTER FC500

Standard Operating Procedure For: Independent End User Training and Maintaining Optimal Instrument Performance:

BD CellQuest Pro Acquisition Tutorial

The Danish Stem Cell Center (DanStem) Danish Stem Cell Center Flow Cytometry Core Facility. LSR Fortessa Guide

BD Multiwell AutoSampler Additional Features Tutorial

STAINING PROTOCOL FOR CYTOMETRY (Réf LabEx #1)

Comparing technical specification documents

Offline Flow Cytometry Analysis Software: Importance of Scaling and Data Visualization

Release Notes Life Technologies Attune NxT Software v2.3

Gallios TM Quick Reference

Log into the computer using your CU Denver username and password. Log into the DIVA software using your CU and Username and the password flow

Science is hard. Flow cytometry should be easy.

FloMax Software for Cytometry. Operating Manual Instrument Control and Acquisition. FloMax Operating Manual Instrument Control and Acquisition

FlowJo Software Lecture Outline:

Release Notes Thermo Fisher Scientific Attune NxT Software v2.4

Release Notes Life Technologies Attune NxT Software v2.2

Attune NxT Acoustic Focusing Cytometer

Quick Start Guide: COLLECT

MA900 Multi-Application Cell Sorter

North America/International Japan Europe

Customer ( you ) must review these notes prior to installing or operating the Attune NxT Software version ( Attune Software v1.1.0 ).

CELLQuest Acquisition Tutorial

Spherotech, Inc Irma Lee Circle, Lake Forest, IL

User Manual. For Windows operating systems Excelsior Blvd. Suite Pécs St. Louis Park, MN Kedves street 20

Getting Started. COULTER EPICS XL TM Flow Cytometer COULTER EPICS XL-MCL TM Flow Cytometer SYSTEM II TM Software. PN BA (October 2010)

A Bright Cytometer Easy to use

Flow Cytometry/FACS Bio-Rad S3e Cell Sorter

Getting Started in FCS Express for Previous FlowJo Users

NovoSampler Pro Operator s Guide

FX500 Exchangeable Fluidics Cell Sorter

Sysmex CyFlow Cube Series

Tecan crystallisation robot user guide

FLUORESCENCE ACTIVATED CELL SORTING (FACS)

Offline Flow Cytometry Analysis Software: Importance of Scaling and Data Visualization

BD FACSLink LIS Interface Solution User s Guide

Hacking FlowJo VX. 42 Time-Saving FlowJo Shortcuts To Help You Get Your Data Published No Matter What Flow Cytometer It Came From

4 plate fully automated ELISA analyzer Reagent system. Open (Human tests predefined) Throughput (max.) Up to 7 plates / run Reaction / reading system

Instructions for Use. COULTER EPICS XL Flow Cytometer COULTER EPICS XL-MCL Flow Cytometer SYSTEM II Software. PN CA (September 2010)

Data acquisition and analysis of MACSPlex Exosome Kit using the MACSQuant Analyzer Express Mode in MACSQuantify Software version 2.

Getting Started. Ohm Portal. v2_ec01b38. Buddy Platform, Limited Ltd.

BD FACS Sample Prep Assistant III Instructions For Use

Hints for Working with Diva FCS 3.0 files in FlowJo Workspaces By Julie Yuan, SickKids-UHN Flow and Mass Cytometry Facility

Flowlogic. User Manual Version GraphLogic: Developed by scientists, for scientists. Graphing and Statistical Analysis.

BioRobot 9604 Operating Procedure

Aqueous GPC Instructions - Detailed

APS (Automatic Population Separator)

Workflow Optimization with EZ Access and ChemStation Browser. Tony Brand, Ph.D., Agilent Technologies, Inc., North Carolina, USA

BD Lyoplate Human Screen Analysis Instructions For analysis using FCS Express or FlowJo and heatmap representation in Excel 2007

BD Spigot to BD FACS Sortware Conversion Guide

BD FACS Loader Reference Manual

Sepacore X10 / X50 system Technical data sheet

Cytomics FC 500 Quick Reference

FACScan 4 and 5 Color Upgrade Rainbow Users Guide

eprep Sample Preparation Workstation

MACSQuantify Software 2.11

SymBiot I Sample Workstation

Guidebook for Installation and Familiarization. HP 1100 Series Combinatorial Chemistry Analysis System

Introduction to the HPLC ChemStation and Acquisition

Reagent Transfer User Guide

Data acquisition and analysis of MACSPlex Cytokine Kits using the MACSQuant Analyzer Express Modes in MACSQuantify Software version 2.

1 plate fully automated ELISA analyzer Reagent system. Open (Human tests predefined) Throughput (Max.) 1 plate /run Barcode reader

BD FACSDiVa Option. BD Biosciences Clontech Discovery Labware Immunocytometry Systems Pharmingen

BD CellQuest Pro Software Reference Manual BD CellQuest Pro Software Reference Manual

Cytometry Data Analysis in FlowJo V10. Timothy Quinn Crawford, PhD Application Scientist FlowJo, LLC

Data acquisition and analysis of MACSPlex Cytokine Kits using the MACSQuant Analyzer Express Modes in MACSQuantify Software version 2.

CyFlow Cube 6 Instrument Operating Manual

Standard Operating Procedure for the HPLC-ICP-MS System By Celina Dozier Fall 2017

Gallios Flow Cytometer

Easy Comext (or Easy XTnet) is an HTML based interface giving to the public at Eurostat s External Trade database.

Mitos Duo XS-Pump Part No

MICROFLUIDIC EOF KIT 9015

Easy user s guide <outline>

GEMINI. Compact Microplate Processor. System Guide

Machine Starters Kit

LSM510 Confocal Microscope Standard Operation Protocol Basic Operation

Transcription:

ZMBH - Zentrum für Molekulare Biologie der Universität Heidelberg Flow Cytometry & FACS Core Facility BD FACSCanto TM with HTS User's Guide For authorization to use the FACSCanto II cytometer, you first have to receive a training and must accept the user rules of the facility! Tube-based Acquisition Cytometer Startup 1. Remove HTS cover. 2. Remove sample coupler from SIT. 3. Re-install HTS cover. 4. Switch on computer. 5. In Windows log in as Operator > Password:... 6. Switch on cytometer. 7. Launch Diva. 8. Select your account and log in. 9. Cytometer > Fluidics Startup Data Acquisition 1. Create a new experiment in the browser. 2. Select the detectors you want to use in the cytometer settings window and delete nonused ones. 3. Create a new specimen and activate the first tube with the tube pointer. 4. Create plots on worksheet and define axis labels. Open Population Hierarchy and Statistics View with right-click on plot. Right-click on Statistics View to edit. 5. Move aspirator arm to the left and install the first sample tube on the SIT. 6. Click Acquire Data in the Acquisition Dashboard. 7. Adjust PMT voltages in the Cytometer Settings window. 8. Define gates. 9. Define number of events to record, stopping gate, etc. 10. Click Record Data in the Acquisition Dashboard. 11. Click Remove Tube and move aspirator arm all the way to the left. Then take out the tube and wait for the flush to complete before installing the next sample.

Exporting Data To export FCS files go to File > Export > FCS To create a PDF file right-click the experiment > Batch Analysis > select Save as PDF and define storage location (USB stick) > start To create a CSV file based on the statistics selected in the Statistics View right-click the experiment > Batch Analysis > select Save Statistics and define storage location (USB stick) > start Cleaning 1. Install tube with FACS Clean. 2. Cytometer > Cleaning Modes > Clean Flow Cell 3. Repeat 3 times. 4. Install tube with FACS Rinse. 5. Cytometer > Cleaning Modes > Clean Flow Cell 6. Repeat 3 times. Cytometer Shutdown 1. Cytometer > Fluidics Shutdown 2. Switch off cytometer. 3. Empty the Waste Tank, and then fill in 500 ml FACS Clean. 4. Replace Sheath or Shutdown Solution Tank if empty.

Plate-based Acquisition (96-well or 384-well) Cytometer Startup 1. Remove HTS cover. 2. Make sure that the sample coupler is installed on the SIT. 3. Re-install HTS cover. 4. Switch on computer. 5. In Windows log in as Operator > Password:... 6. Switch on cytometer. 7. Launch Diva. 8. Select your account and log in without password. 9. Cytometer > Fluidics Startup Data Acquisition 1. Create a new experiment in the browser. 2. Select the detectors you want to use in the Cytometer Settings window and delete nonused ones. 3. Create a new specimen and activate the first tube with the tube pointer. 4. Create plots on worksheet and define axis labels. Open Population Hierarchy and Statistics View with right-click on plot. Right-click on Statistics View to edit. 5. Open a new plate in the browser. Make sure to select the correct plate type. 6. In the plate layout define 1-2 setup wells. 7. Click Run Wells in the Acquisition Dashboard. 8. Adjust PMT voltages in the cytometer settings window. 9. Define gates. 10. In the plate layout define specimen wells. 11. Select the wells you want to record. Choose sampling mode and adjust loader settings if needed. 12. Define number of events to record, stopping gate, etc. for each well using either the Acquisition Dashboard or go to Experiment > Experiment Layout. 13. Click Run Plate.

Exporting Data To export FCS files go to File > Export > FCS To create a PDF file right-click the experiment > Batch Analysis > select Save as PDF and define storage location (USB stick) > start To create a CSV file based on the statistics selected in the Statistics View right-click the experiment > Batch Analysis > select Save Statistics and define storage location (USB stick) > start Cleaning 1. Install a plate with 200 µl FACS Clean in well A1-A4 and 200 µl DI Water in well B1-B4. 2. HTS > Clean. Cytometer Shutdown 1. Cytometer > Fluidics Shutdown 2. Switch off cytometer. 3. Empty the Waste Tank, and then fill in 500 ml FACS Clean. 4. Replace Sheath or Shutdown Solution Tank if empty.

HTS Specifications Standard Mode High Throughput Mode Default Range Default Range Well volume 96 well 250 µl 50-300 µl 100 µl 50-300 µl Well volume 384 well 50 µl 50-120 µl 50 µl 50-120 µl Aspirated volume sample volume + 20 µl fixed volume = 22 µl Sample volume 10 µl 2-200 µl 2 µl 2-10 µl Sample flow rate 1 µl/s 0.5-3.0 µl/s 1 µl/s 0.5-3.0 µl/s Sample flow rate 60 µl/min 30-180 µl/min 60 µl/min 30-180 µl/min Mixing volume one-half the available volume Mixing speed 180 µl/s 25-250 µl/s 200 µl/s 25-250 µl/s Number of mixes 2 0-5 2 0-5 Wash volume 400 µl 200-800 µl 200 µl 200-800 µl Stopping time 1 well Max event rate sample volume (µl)/sample flow rate (µl/s) 35000 evt/s