Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Similar documents
Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

LM24A-MOD. Cable 1 m, 6 x 0.75 mm 2 RJ12 socket

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency. Draft

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

s Spring return C / max C

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

9.5 nominal torque 4.5 W 16 VA. Min. 30 nominal voltage Min. 30 Nm. Reversible with switch By mounting. MIN (minimum position)

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Brief description. Service tool ZTH, PC-Tool service socket: locally pluggable or via PP connection.

Technical data. Safety notes. Product features

Technical data sheet. Technical data

Functional data Factory settings Variable Setting Torque Inhibiting torque

Technical data sheets

Power consumption In operation At rest For wire sizing

Belimo Gateway MP to Modbus RTU - UK24MOD

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Belimo Gateway MP to Modbus RTU - UK24MOD

Overview of types. Technical data

Brief description. Type overview

Brief description. Type overview

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manuelle Auslösung der Adaption durch Drücken der Taste «Adaption» oder mit dem PC-Tool

Products no longer available

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range

VAV system solution for non-pressure dependent applications in enclosed spaces

Products no longer available

Technical data. PRCA-BAC-S2-T en-gb subject to changes 1

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency

NKQB24-1, NKQX24-1 On/Off, Electronic Fail-Safe, Direct Coupled, 24V

Functional data Nominal torque min. 180 in lb [20 NM] Communicative control Cloud: (call for clientapi )

NKQB24-1, NKQX24-1 On/Off, Fail-Safe, Operation, Direct Coupled, 24V

Technical data sheet

Functional data Position indication reflective visual indicator (snap on) Communicative control Cloud: (call for clientapi )

BUS. Adaptive control system for pressure applications (STP) Table of contents

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

Functional data Communicative control Cloud: (call for clientapi ) Angle of rotation 90

A CLOSER LOOK. Electronic Fail-Safe Series Direct Coupled Actuators. The Belimo Difference. Brushless DC Motor for Added Accuracy and Controllability

Installation VAV-Compact Retrofit Set

Control engineering information VARYCONTROL VAV Units VAV Compact flow rate controller BC0 BF0

ZN230-24MP-1 MP-BUS

BUS. Adaptive VAV control system for sensitive working areas. Table of contents

Functional data Communicative control Cloud: (call for clientapi ) Angle of rotation 90

Air Damper Actuators Modbus RTU

Air Damper Actuators Modbus RTU

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Output Signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power Supply DC V, ±10%, 0.3 W

InReg Volume flow controller Pa

IQ-MP Gateway. Version apr Electrocom Rødeledsvej 95 DK-5700 Svendborg Denmark Tel :

VAV Compact Controller Modbus RTU

Output signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power supply DC V, ±10%, 0.3 W

Rotary version, three-position control

Products no longer available

Modbus TCP/RTU MP-Bus converter

Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator

Output Signal. Temperature 22DTH-56M BACnet DC V, DC V. Electrical Data Power Supply DC V, ±10%, 0.7 W

Electric Actuators Type 5824 (without fail-safe action) Type 5825 (with fail-safe action)

VAV compact controller KNX / PL-Link

B. AVM321S/AVM322S: 1000N Actuator with analog SUT positioner

VAV compact controller GDB181.1E/3 GLB181.1E/3

Zelio Control-modular measurement and control relays 1

Cables. U.S. Registered Trademark EN0B-0341GE51 R0402 Copyright 2002 Honeywell Inc. All rights reserved

Product information. Technical data. Safety notes. Definitions

Output signal active note. Output signal. temperature DC V, DC V DC V, DC V DC V

Non-communicating room controllers

Products no longer available

AIAS. Technical description

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

SIMOCODE 3UF Motor Management and Control Devices

Andover ContinuumTM b3865/866 VAV Controllers with Built-in Actuator

Belimo Gateway MP to BACnet MS/TP - UK24BAC

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Use. Functions. OpenAir TM. Linear version, modulating, AC 24 V

VFC. Operating manual TROX air terminal units Type VFC volume flow controllers. General information 2. VFC series volume flow controllers

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

VAV compact controller

Air damper actuators

Actuators for CAV control lers

Belimo Gateway MP to LONWORKS - UK24LON

Power consumption motor (motion) 2,5 W Power consumption standby (end position) 1,0 W. Position feedback -

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

Compact Universal Controllers

InCos-P Pressure sensor 20 Pa Pa

Super universal modules

Control components for VAV terminal units

ARI-PREMIO Plus 2G Electric thrust actuator with fail-safe function

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

Product information. Technical data. Safety notes. Definitions

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

Contact protection relay

Transcription:

echnical data sheet SF24A-MOD Communicative spring-return actuator with emergency control function for adjusting dampers in technical building installations Air damper size up to approx. 4 m² Nominal torque 20 Nm Nominal voltage AC/DC 24 V Conversion of sensor signals Communication via Modbus RU (RS-485) echnical data Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency 50/60 Hz Nominal voltage range AC 19.2...28.8 V / DC 21.6...28.8 V Power consumption in operation 8.5 W Power consumption in rest position 3.5 W Power consumption for wire sizing 11 VA Connection supply / control Cable 1 m, 6 x 0.75 mm² Data bus communication Protocol Modbus RU (RS-485), not galvanically isolated Number of nodes Max. 32 (without repeater) ransmission formats 1-8-N-2, 1-8-N-1, 1-8-E-1, 1-8-O-1 Baud rate 9600, 19,200, 38,400, 76,800, 115,200 Bd Default: 38,400 Bd erminating resistor 120 Ohm, can be switched Parameterisation with service tool ZH EU Pushbutton-operated fast addressing 1... 16 possible Functional data orque motor Min. 20 Nm orque spring return Min. 20 Nm Position accuracy ±5% Direction of motion motor Selectable with switch L / R Direction of motion emergency control Selectable by mounting L / R function Manual override By means of hand crank and locking switch Angle of rotation Max. 95 Angle of rotation note adjustable starting at 33% in 2.5% steps (with mechanical end stop) Running time motor 150 s / 90 Motor running time variable 70...220 s Running time emergency control position <20 s / 90 Running time emergency setting position <20 s @ -20...50 C / <60 s @ -30 C note Adaption setting range manual Adaption setting range variable No action Adaption when switched on Adaption after pushing the gear disengagement button Override control, controllable via Modbus MAX (maximum position) = 100% MIN (minimum position) = 0% ZS (intermediate position) = 50% Override control variable MAX = (MIN 32%)...100% MIN = 0%...(MAX 32%) ZS = MIN...MAX Sound power level motor 40 db(a) Spindle driver Universal spindle clamp 10...25.4 mm Position indication Mechanical Service life Min. 60,000 emergency positions Safety Protection class IEC/EN III Safety extra-low voltage Protection class UL UL Class 2 Supply Degree of protection IEC/EN IP54 www.belimo.eu SF24A-MOD en-gb 2016-03-03 subject to changes 1

20 Nm, Communication via Modbus RU (RS-485) echnical data Safety Degree of protection NEMA/UL NEMA 2, UL Enclosure ype 2 EMC CE according to 2014/30/EU Certification IEC/EN IEC/EN 60730-1 and IEC/EN 60730-2-14 Certification UL culus according to UL 60730-1A, UL 60730-2- 14 and CAN/CSA E60730-1:02 Mode of operation ype 1.AA Rated impulse voltage supply / control 0.8 kv Control pollution degree 3 Ambient temperature -30...50 C Non-operating temperature -40...80 C Ambient humidity 95% r.h., non-condensing Maintenance Maintenance-free Weight Weight 2.4 kg Safety notes! he device must not be used outside the specified field of application, especially not in aircraft or in any other airborne means of transport. Outdoor application: only possible in case that no (sea)water, snow, ice, insolation or aggressive gases interfere directly with the actuator and that is ensured that the ambient conditions remain at any time within the thresholds according to the data sheet. Only authorised specialists may carry out installation. All applicable legal or institutional installation regulations must be complied during installation. he device may only be opened at the manufacturer s site. It does not contain any parts that can be replaced or repaired by the user. Cables must not be removed from the device. o calculate the torque required, the specifications supplied by the damper manufacturers concerning the cross-section, the design, the installation site and the ventilation conditions must be observed. he device contains electrical and electronic components and must not be disposed of as household refuse. All locally valid regulations and requirements must be observed. Product features Mode of operation Converter for sensors Parameterisable actuators Simple direct mounting Manual override High functional reliability Adjustable angle of rotation he actuator is fitted with an integrated interface for Modbus RU, it receives the digital positioning signal from the Modbus-Master and returns the current status. Connection option for a sensor (passive or active sensor or switching contact). In this way, the analogue sensor signal can be easily digitised and transferred to Modbus. he factory settings cover the most common applications. Single parameters can be modified with the Belimo Service ools MF-P or ZH EU. he Modbus communication parameters (address, baud rate etc.) are set with the ZH EU. Pressing push-button Service on the actuator while connecting the supply voltage resets the communication parameters to the factory setting. Quick addressing: he Modbus address can alternatively be set using push-buttons on the actuator from 1 to 16. he value selected is added to the «Basic address» parameter and results in the effective Modbus address. For example, with a basic address of 140, Modbus addresses between 141 and 156 can be parameterised using quick addressing. Simple direct mounting on the damper spindle with an universal spindle clamp, supplied with an anti-rotation device to prevent the actuator from rotating. By using the hand crank the damper can be actuated manually and engaged with the locking switch at any position. Unlocking is carried out manually or automatically by applying the operating voltage. he actuator is overload protected, requires no limit switches and automatically stops when the end stop is reached. Adjustable angle of rotation with mechanical end stops. 2 SF24A-MOD en-gb 2016-03-03 subject to changes www.belimo.eu

20 Nm, Communication via Modbus RU (RS-485) Product features Home position Adaption and synchronisation he first time the supply voltage is switched on, i.e. at the time of commissioning, the actuator carries out a synchronisation. he synchronisation is in the home position (0%). he actuator then moves into the position defined by the positioning signal. An adaption can be triggered manually by pressing the Adaption button or with the PC-ool. Both mechanical end stops are detected during the adaption (entire setting range). Automatic synchronisation after actuating the hand crank is programmed. he synchronisation is in the home position (0%). he actuator then moves into the position defined by the positioning signal. A range of settings can be adapted using the PC-ool (see MF-P documentation) Accessories Description Electrical accessories Auxiliary switch, 2 x SPD S2A-F Feedback potentiometer, 200 Ohm, incl. installation accessories P200A-F Feedback potentiometer 1 kohm, incl. installation accessories P1000A-F Connecting cable 5 m, AB: RJ12 6/6, o ZH/ZIP-USB-MP ZK1-GEN Connection cable 5 m, A: RJ11 6/4, B: Free wire end, o ZH/ZIP- USB-MP ZK2-GEN Description Mechanical accessories Shaft extension 250 mm, for damper spindles Ø 8...25 mm AV8-25 End stop indicator for NF..A / SF..A IND-AFB Spindle clamp set for NF..A/SF..A (1, 3/4, 1/2 ) K7-2 Straight ball joint with M8, suitable for damper crank arms KH8 KG10A Angled ball joint with M8, suitable for damper crank arms KH8 KG8 Damper crank arm, for damper spindles KH8 Damper crank arm for NF..A / SF..A, for 3/4 spindles KH-AFB Form fit insert 10x10 mm, for spring return actuators NG ZF10-NSA-F Form fit insert 12x12 mm, for spring return actuators NG ZF12-NSA-F Form fit insert 16x16 mm, for spring return actuators NG ZF16-NSA-F Damper crank arm, for spring return actuators NG ZG-AFB Base plate extensions for NF..A/SF..A Z-SF ype ype Service ools Description Service ool, for MF/MP/Modbus/LonWorks actuators and VAV- Controller Belimo PC-ool, software for adjustments and diagnostics Adapter to Service ool ZH ype ZH EU MF-P MF-C www.belimo.eu SF24A-MOD en-gb 2016-03-03 subject to changes 3

20 Nm, Communication via Modbus RU (RS-485) Electrical installation! Wiring diagrams Modbus wiring Notes Connection via safety isolating transformer. he wiring of Modbus RU (RS485) is to be carried out in accordance with applicable regulations (www.modbus.org). he device has switchable resistors for bus termination. Modbus-GND: Supply and communication are not galvanically isolated. Connect earth signal of the devices with one another. D D Master AC/DC 24 V MF D D MF D D AC/DC 24 V Slave 1 Slave 32 Connection without sensor MF D D Note Modbus signal assignment: C₁ = D- = A C₂ = D = B Connection with passive sensor, e.g. Pt1000, Ni1000, NC Ni1000 28...98 C 850...1600 Ω 2) MF D D P1000 35...155 C 850...1600 Ω 2) NC 10...160 C 1) 200 Ω...60 kω 2) 1) depending on type 2) Resolution 1 Ohm Connection with switching contact, e.g. pressure control device Connection with active sensor, e.g. 0...10 V @ 0...50 C p MF D D Requirements for switching contact: he switching contact must be able to accurately switch a current of 16 ma @ 24 V. MF D D Possible voltage range: 0...32 V (resolution 30 mv) 4 SF24A-MOD en-gb 2016-03-03 subject to changes www.belimo.eu

20 Nm, Communication via Modbus RU (RS-485) Modbus communication parameters Register No. Adr Register 1 0 Setpoint [%] 2 1 Override control 3 2 Command 4 3 Actuator type 5 4 Relative position [%] 6 5 Absolute position [ ] [mm] 7 6 Relative volumetric flow [%] (only for VAV/EPIV) 8 7 Absolute volumetric flow (pressure) [m 3 /h] [l/min] [Pa] (only for VAV/EPIV) 9 8 Sensor value [mv] [Ω] [] 101 100 Series number 1st part 102 101 Series number 2nd part 103 102 Series number 4th part 104 103 Firmware version (Modbus module) 105 104 Malfunction and service information 106 105 Min [%] 107 106 Max [%] 108 107 Sensor type 109 108 Bus fail position In operation Service Registers in Bold can be written Registers <100 (In operation) which can be written are volatile and should therefore be updated periodically Registers >100 which can be written are non-volatile Commands Note regarding Read Discrete Inputs he command reads one or more bits and can alternatively be used for register 105 (Malfunction and service information). he start address to be used is 1664. All data is arranged in a table and addressed by 1..n (register) or 0..n-1 (address). No distinction is made between data types (Discrete Inputs, Coils, Input Registers, Holding Registers). As a consequence, all data can be accessed with the two commands for Holding Register. he commands for Discrete Inputs and Input Registers can be used as an alternative. Standard commands: Read Holding Registers [3] Write Single Register [6] Optional commands: Read Discrete Inputs [2] Read Input Registers [4] Write Multiple Registers [16] www.belimo.eu SF24A-MOD en-gb 2016-03-03 subject to changes 5

20 Nm, Communication via Modbus RU (RS-485) Modbus communication parameters Register 1: Setpoint Register 2: Override control Register 3: Command Register 4: Actuator type Register 5: Relative position Register 6: Absolute position Register 7: Relative volumetric flow Register 8: Absolute volumetric flow Setpoint for actuator setting or volumetric fl ow in hundredths of one percent, i.e. 0 10 000 corresponds to 0 100% Overriding the setpoint with defined values Override control 0 None 1 Open 2 Close 3 Min 5 Max Initiation of actuator functions for service and test; the register is reset automatically. Command 0 None 1 Adaption 2 est run 3 Synchronisation 4 Reset actuator malfunctions Actuator type; the allocation may deviate from the basic category with some actuators. Actuator type 0 Actuator not connected / not known 1 Air/water actuators with/without safety function 2 Volumetric fl ow controller VAV / EPIV 3 Fire damper actuator Relative position in hundredths of one percent, i.e. 0 10 000 correspond to 0 100% Absolute position 0 10 000 (65535 if not supported by the actuator) he unit depends on the device: [ ] for actuators with rotary movement [mm] for actuators with linear movement Relative volumetric flow in hundredths of one percent of Vnom, i.e. 0 10 000 correspond to 0 100% his value is available only for VAV controllers and EPIV devices (actuator type: 2). For all other types, 65535 will be entered. Absolute volumetric flow his value is available only for VAV controllers and EPIV devices (actuator type: 2). For all other types, 65535 will be entered. he unit depends on the device: [m 3 /h] for VAV controllers (or [Pa] for pressure applications) [l/min] for EPIV devices Register 9: Sensor value Current sensor value; dependent on the setting in Register 108 he unit depends on the sensor type: [mv] [Ω] [-] Register 101-103: Series number Register 104: Firmware Version Each device has an unambiguous series number which is either impr essed on or glued to the housing. he series number consists of 4 segments, although only parts 1, 2 and 4 are displayed on Modbus. Example: 00839-31324-064-008 Register 101 Register 102 Register 103 1st part 2nd part 4th part 00839 31234 008 Firmware version of Modbus module (VX.XX) e.g. 101 V1.01 6 SF24A-MOD en-gb 2016-03-03 subject to changes www.belimo.eu

20 Nm, Communication via Modbus RU (RS-485) Modbus communication parameters Register 105: Malfunction and service information he status information is split into messages about the actuator (malfunctions) and other service information. Malfunctions (low byte) Service (high byte) Bit Description 0 Excessive utilisation 1 Mechanical travel increased 2 Mechanical overload 3 4 Safety-relevant faults (fire protection only) 5 Damper test error (fi re protection only) 6 Duct temperature too high (fire protection only) 7 Smoke detector tripped (fi re protection only) 8 Internal activity (test run, adaption, ) 9 Gear disengagement active 10 Bus watchdog triggered 11 12 13 14 15 he malfunction bits can be reset with Register 3 (command 4) or with the Belimo PC-ool. Malfunctions 0 and 4 cannot be reset. Register 106: Min / Vmin setting Register 107: Max / Vmax setting Register 108: Sensor type Notes After changing the sensor type, the actuator must always be restarted in order for correct sensor values to be read out. By using actuator variants with RJ12 sockets (J6) sensor values are not available, as connecting a sensor is not possible. Register 109: Bus fail position Minimum limit (position or volumetric fl ow) in hundredths of one percent, i.e. 0 10 000 correspond to 0 100% Caution: Changing the setting may result in malfunctions. Maximum limit (position or volumetric fl ow) in hundredths of one percent, i.e. 2000 10 000 correspond to 20 100% Caution: Changing the setting may result in malfunctions. Sensor type connected to the actuator; in the absence of sensor specification, the switching at the Y input will have the effect of a local compulsion. Sensor type 0 None 1 Active sensor (mv) 2 Passive sensor 1 k (Ω) 3 Passive sensor 1 20 k (Ω) 4 Switching contact (0 / 1) Modbus communication is not monitored as standard. In the event of a breakdown in communication, the actuator retains the current setpoint. he bus monitoring controls the Modbus communication. If neither the setpoint (Register 1) nor the override control (Register 2) is renewed within 120 seconds, the actuator controls to the bus fail position. riggered bus monitoring is indicated in Register 105. Bus fail position 0 Last setpoint (no bus monitoring) 1 Fast close if time is exceeded 2 Fast open if time is exceeded 3 Parameterized intermediate position Mid if time is exceeded www.belimo.eu SF24A-MOD en-gb 2016-03-03 subject to changes 7

20 Nm, Communication via Modbus RU (RS-485) Operating controls and indicators 3 Adaption Address Power Status 1 Membrane key and LED display green Off: No power supply or malfunction On: In operation Flashing: In address mode: Pulses according to set address (1...16) When starting: Reset to factory setting (Communication) Press button: In standard mode: riggers angle of rotation adaptation In address mode: Confirmation of set address (1...16) 2 Push-button and LED display yellow Off: On: Flickering: Press button: Standard mode Adaptation or synchronising process active or actuator in address mode (LED display green flashing) Modbus communication active In operation (>3 s): Switch address mode on and off In address mode: Address setting by pressing several times When starting (>5 s): Reset to factory setting (Communication) 3 Service plug For connecting parameterisation and service tools Operating elements he manual override, locking switch and direction of rotation switch elements are available on both sides Service Quick adressing Modbus Service ools connection 1. Press the Service button until the green Power LED is no longer illuminated. he green Adaption LED flashes in accordance with the previously set address. 2. Set the address by pressing the Service button the corresponding number of times (1-16). 3. he green LED flashes in accordance with address that has been entered (1-16). If the address is not correct, then this can be reset in accordance with Step 2. 4. Confirm the address setting by pressing the green Adaption button. If no confirmation occurs for 60 seconds, then the address procedure is ended. Any address change that has been made will be discarded. he resulting Modbus address is made up of the set basic address plus the short address (e.g. 1407=147). he actuator can be parameterised by ZH EU via the service socket. For an extended parameterisation the PC tool can be connected. AC 24 V DC 24 V MP USB ZH EU i esc OK BELIMO PC-ool MF D D USB 8 SF24A-MOD en-gb 2016-03-03 subject to changes www.belimo.eu

20 Nm, Communication via Modbus RU (RS-485) Dimensions [mm] Spindle length Dimensional drawings L Clamping range Min. 85 Min. 15 60 20.5 93 10...22 10 14...25.4 12.5 19...25.4 12...18 80 98 32 27 162 172 182 236 www.belimo.eu SF24A-MOD en-gb 2016-03-03 subject to changes 9