Differential pressure sensor For ventilation and air-conditioning Model A2G-50

Similar documents
Dual differential pressure sensor For ventilation and air-conditioning Model A2G-52

Pressure sensor For highest pressure applications to 15,000 bar Model HP-2

Threaded resistance thermometer Miniature design Model TR10-D

Micro calibration bath Models CTB , CTB

Hand-held thermometer, precision version Model CTH6500 Model CTH65I0, Ex version

Threaded thermocouple Miniature design Model TC10-D

Temperature dry-well calibrator Models CTD , CTD

Miniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm

Hand-held thermometer, industrial version Model CTH6300 Model CTH63I0, Ex version

Temperature dry-well calibrator Models CTD9100-COOL, CTD , CTD , CTD

Hand-held thermometer Model CTH6200

Resistance thermometer With spring-loaded tip Model TR55

Level sensor Stainless steel version Model RLT-1000, for industrial applications

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Bourdon tube pressure gauge with electrical output signal Stainless steel, safety version, NS 63 Model PGT23.063

CalibratorUnit Models CPU6000-W, CPU6000-S, CPU6000-M

Temperature dry-well calibrator Models CTD9100-COOL, CTD , CTD , CTD

Portable low-pressure controller Model CPC2000

Hand-held thermometer Model CTH7000

Gas-actuated thermometer Stainless steel version Model 73

Reed sensor For bypass level indicators Model BLR

Programming unit VIATOR HART modems Model PU-H

Electronic pressure switch with display Model PSD-4

Electronic pressure switch with display For sanitary applications Model PSA-31

ProcessCalibrator Model CPH6000

USB pressure transmitter model CPT2500 with model CPA2500 USB adapter and USBsoft2500 software

Precision thermometer Model CTR2000

Float switch For industrial applications Model RLS-1000

Portable pressure calibrator Model CPH7600

USB pressure sensor With USB adapter and software Model CPT2500

Precision hand-held pressure indicator Model CPH6400

Multi-functional precision thermometer CTR3000

Electronic pressure switch with display For sanitary applications Model PSA-31

Precision pressure indicator 1- or 2-channel version Model CPG2500

Level sensor with reed measuring chain Model FLR, for the process industry

Precision thermometer Model CTR5000

DP2500 DP0250. Differential Pressure Transmitter. Product Bulletin

Bayonet resistance thermometer Model TR53

Electronic pressure switch with display For sanitary applications Model PSA-31

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

High-end pressure controller Model CPC8000

Hand-held thermometer Model CTH6200

DP DP2500 DP0250

Precision digital pressure gauge Model CPG1500

Pneumatic precision pressure controller Model CPC6000

ProcessCalibrator Model CPH6000

Hand-held thermometer Model CTH7000

Standard reference resistor Model CER6000

Precision digital gas density indicator Model GDI-100-D

DC resistance thermometry bridge Model CTR6000

High-Precision Pneumatic Pressure Controller Series CPC8000-L/-X

Data sheet * * Digital 2-channel transmitter for direct connection to bus-capable automation devices. Design and mode of operation

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

Pneumatic precision pressure controller Model CPC6000

Datasheet DE DB_EN_DE45_LCD Rev. ST4-G 11/17. Digital differential pressure switch / transmitter with colour-change LCD * *

Multi-range pressure and differential pressure transmitter

Pneumatic precision pressure controller Model CPC6000

Hand-held pressure indicator Model CPH6300-S1 (1-channel version) Model CPH6300-S2 (2-channel version)

Air data test indicator Model CPA2501

Threaded resistance thermometer With protection tube Model TR10-C

ProcessCalibrator Model CPH6000

USER GUIDE PEL / PEL-M

DIFFERENTIAL PRESSURE TRANSMITTER with MODBUS interface Optional Input module

Portable Multi-Function Calibrator Model CEP6000

Thermocouples Model TC200, for Additional Thermowell

Resistance thermometer For additional thermowell Model TR10-B

Float Switches with Permanent Magnet For Vertical Installation Model RSM

USER GUIDE PEL 8K / PEL 8K-M

Threaded resistance thermometer Model TR10-C, with protection tube

Precision digital pressure gauge Model CPG1500

DCT 531. Industrial Pressure Transmitter with RS485 Modbus RTU. Stainless Steel Sensor

Float Switches with Permanent Magnet For Horizontal Installation Model HIF

Hand-held pressure indicator Model CPH6200-S1 (1-channel version) Model CPH6200-S2 (2-channel version)

Pressure transmitter for mobile hydraulic applications With output signals CANopen and J1939

Adapter system for measuring instruments with G1 hygienic connection Model process adapter

Hydrostatic filling level sensor HFB C4 / R / MD

Pneumatic precision pressure controller Model CPC6000

Hand-Held Thermometer Model CTH 6200

Pneumatic High-Speed Pressure Controller Model CPC3000

Portable pressure calibrator Model CPH7650

DMT PERFORMING UNDER PRESSURE DMT. With USB adapter and software. Applications. Special features. Description 1/7

DMT PERFORMING UNDER PRESSURE DMT. Applications. Special features. Description 1/9

Pneumatic Precision Pressure Controller Model CPC6000

Thermal Mass Flowmeter Sensyflow FMT200-D

LMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO.

PCD DIGITAL Differential pressure probe

Datasheet DE DB_EN_DE44_LCD Rev. ST4-C 07/17. Digital 2-channel differential pressure switch/transmitter with colour-change LCD * *

Calibration software Model WIKA-Cal

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

Air Quality Solutions

Differential pressure and air velocity measurement instruments

TM172PBG42R Modicon M172 Performance Blind 42 I/Os, Ethernet, Modbus

Type Differential pressure transducer

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

Differential Pressure Controller DPC 200

DPA+ LCD. Application. Types Available. Differential Pressure Transmitter. Datasheet

Operating Instructions for Low Volume Rotating Vane Flow Meter. Model: DPL-1P... DPL-1V... DPL-1E...

LMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions

High-speed peumatic pressure controller Model CPC3000

Transcription:

Electronic pressure measurement Differential pressure sensor For ventilation and air-conditioning Model A2G-50 WIKA data sheet PE 88.02 for further approvals see page 5 Applications For measuring differential pressures and static pressures Monitoring of filters Overpressure monitoring in clean rooms and laboratories Special features Electrical output signal 0... 10 V or 4... 20 ma, can be selected directly at the instrument via jumpers Modbus output signal (option) LC display (option) Maintenance-free Maximum operating pressure 20 kpa Differential pressure sensor, model A2G-50 Description The model A2G-50 differential pressure sensor is used for measuring differential pressures of gaseous media in ventilation and air-conditioning applications. It is based on the piezoresistive measuring principle. This compact differential pressure sensor offers excellent performance and high quality at an attractive price. Electrical analogue output signals for both measurement parameters (0... 10 V or 4... 20 ma; adjustable in the instrument via jumpers) or the digital Modbus versions enable the direct connection to control systems or the building automation system. Page 1 of 5 Data sheets showing similar products: Differential pressure sensor, Eco version; model A2G-55; see data sheet PE 88.04

Specifications Differential pressure sensor, model A2G-50 Measuring element Variant 1 Variant 2 Variant 3 Variant 4 Piezo measuring cell Measuring range 0 2,500 Pa 1) 0 2,000 Pa 2) 0 1,500 Pa 2) 0 1,000 Pa 2) 0 500 Pa 2) 0 250 Pa 2) 0 100 Pa 2) -100 +100 Pa 2) 0 7,000 Pa 1) 0 5,000 Pa 2) 0 4,000 Pa 2) 0 3,000 Pa 2) 0 2,500 Pa 2) 0 2,000 Pa 2) 0 1,500 Pa 2) 0 1,000 Pa 2) -250... +250 Pa 1) -100... +100 Pa 2) -50... +50 Pa 2) -25... +25 Pa 2) 0... 250 Pa 2) 0... 100 Pa 2) 0... 50 Pa 2) 0... 25 Pa 2) 0 12,000 Pa 1) 0 10,000 Pa 2) 0 9,000 Pa 2) 0 8,000 Pa 2) 0 7,500 Pa 2) 0 7,000 Pa 2) -1,000 +1,000 Pa 2) -500 +500 Pa 2) 8 measuring ranges can be selected via jumpers (measuring ranges < 250 Pa: automatic zero point setting (AZ) recommended) Option: Digital indicator (D), automatic zero point setting (AZ), digital indicator and automatic zero point setting (AZ-D) Accuracy 0... 2,500 Pa = pressure < 125 Pa = ±2 Pa + 1 % pressure > 125 Pa = ±1 Pa + 1 % 0... 7,000 Pa = pressure < 125 Pa = ±2 Pa + 1.5 % pressure > 125 Pa = ±1 Pa + 1.5 % 0... 12,000 Pa =pressure < 125 Pa = ±2 Pa + 1.5 % pressure > 125 Pa = ±1 Pa + 1.5 % Units (adjustable in the menu) Air flow Differential pressure Process connection all data refer to the current measured value (of measured pressure) m 3 /h, m 3 /s, l/s, cfm Pa, kpa, mbar, inwc, mmwc Connecting nozzle (ABS), lower mount, for hoses with inner diameter 4 or 6 mm Power supply U B With automatic zero point setting (AZ) Without automatic zero point setting (AZ) Electrical connection AC 24 V or DC 24 V ±10 % Output signal 0... 10 V: DC 14... 30 V or AC 24 V ±10 % Output signal 4... 20 ma: DC 9... 30 V or AC 24 V ±10 % Cable gland M16 Screw terminals max. 1.5 mm 2 DC 0 10 V (3-wire) or 4 20 ma (3-wire) Output signal Current consumption < 1.0 W (DC 0 10 V), < 1.2 W (4 20 ma), < 1.3 W (Modbus ) Case Plastic (ABS) Permissible temperatures Ambient temperature Storage temperature Medium temperature Ingress protection Weight -20 +70 C -50 +70 C -10 +50 C IP54 150 g 1) Standard 2) Jumpers Page 2 of 5

Modbus version (option) Modbus communication Protocol Transfer mode Interface Byte format Baud rate Modbus addresses Modbus via serial interface RTU RS-485 (11 bits) in RTU mode Coding system: 8 bits binary Bits per byte: - 1 Start bit - 8 data bits, lowest-order bit is sent first - 1 bit for parity - 1 stop bit 9,600, 19,200, 38,400 - adjustable in the configuration 1 247 addresses - adjustable in the configuration Automatic zero point setting (option) The automatic zero point setting aligns the zero point from time to time so that a manual zero point setting is not necessary. During the zero point setting (3 seconds every 10 minutes), the output signal and the digital display show the last measured value. 40376281X.01 ZERO Page 3 of 5

Electrical connection Output signal DC 0... 10 V Output signal 4... 20 ma V Signal [U] 100 % 10.0 V 0... 10 V not connected 24 V Power supply GND AC/DC 24 V V not connected 4... 20 ma 24 V GND 50 % 5.0 V Power supply AC/DC 24 V 0 % 0.0 V A Signal [U] 100 % 10.0 V A Signal [I] 100 % 20.0 ma 50 % 5.0 V 50 % 12.0 ma 0 % 0.0 V 0 % 4.0 ma Signal [I] 100 % 20.0 ma 50 % 12.0 ma Dimensions in mm 0 % 4.0 ma 40405589.02 Page 4 of 5

Accessories Description Order number Connections for static duct probes for ¼" pipes Insertion length 100 mm 40232956 Insertion length 150 mm 40232964 Insertion length 200 mm 40232972 Measuring hoses PVC hose, inner diameter 4 mm, roll at 25 m 40217841 PVC hose, inner diameter 6 mm, roll at 25 m 40217850 Silicone hose inner diameter 4 mm, roll at 25 m 40208940 Silicone hose inner diameter 6 mm, roll at 25 m 40208958 Duct connector for hose 4 and 6 mm 40217507 Approvals Logo Description Country EC declaration of conformity European Union EMC directive RoHS conformity WEEE directive EAC (option) Eurasian Economic Community Import certificate KazInMetr (option) Kazakhstan - MTSCHS (option) Kazakhstan Permission for commissioning UkrSEPRO (option) Ukraine Uzstandard (option) Uzbekistan Certificates (option) 2.2 test report 3.1 inspection certificate Scope of delivery Differential pressure transmitter 2 mounting screws Approvals and certificates, see website Ordering information Model / Measuring range / Options 08/2008 WIKA Alexander Wiegand SE & Co. KG, all rights reserved. The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. 01/2018 EN Page 5 of 5 WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Straße 30 63911 Klingenberg/Germany Tel. +49 9372 132-0 Fax +49 9372 132-406 info@wika.de www.wika.de