3SE2 / SE3 Molded plastic /metal enclosure with separate actuator Application Safety interlock switches with separate actuator are used where the position of doors, covers or safety screens must be monitored for safety reasons. For example, they can be used together with 3TK28 safety relays up to safety category 4. Construction Interlock switches with separate actuator are available in three versions. Molded plastic enclosure with mounting dimensions according to EN 50 047 Metal enclosure with mounting dimensions according to EN 50 041 Molded plastic enclosure outside of the standards that have arisen in this form in accordance with general market requirements. When used as a safety switch mounting at a spacing of 20 mm (molded plastic housings) or 30 mm (metal housing) is necessary. Or, the interlock switch must be fitted with a pin or stop. Operation Interlock switches with separate actuator can only be operated with a matching triple-coded actuator. Actuation by hand or with auxiliary devices is virtually impossible. The actuators are not included with the interlock switch and must be ordered separately. Side operating heads can be rotated in 90 increments and cannot be replaced with actuators of the standard type. Operating heads for the 3SE2 243 and 3SE2 257 types cannot be changed. Radius actuator Interlock switches with radius actuators are particularly suitable for rotatable protection devices. The movable actuation key allows even small radii to be approached. Damage to the switch and the actuator due to inaccurate approach is prevented. Contact reliability The movable contacts of the 3SE2 120, 3SE3 170 and 3SE2 200 switches are designed as double-break contacts. This ensures extremely high contact stability, even when the devices are switching low voltages and currents, e.g. DC 5V / 1 ma. 13/40
3SE2 / 3SE3 Molded plastic / metal enclosure with separate actuator Technical data Type 3SE2 1, 3SE2 2, 3SE3 2 3SE2 243 Standards IEC 60947-5-1, EN 60947-5-1 (VDE 0660 Part 200) Rated insulation voltage U i V 500 Pollution degree acc. to EN 60664 Class 3 Rated operating voltage U e V AC 500; over AC 380 V only for equal potential Continuous thermal current I th A 10 Rated operating current I e For alternating current 40... 60 Hz I e /AC-12 I e /AC-15 I e /AC-12 I e /AC-15 - at 24 V A 10 10 10 10 - at 125 V A 10 10 10 10 - at 230 V A 10 6 10 4 - at 400 V A 10 4 10 4 - at 500 V A 10 3 10 3 For direct current I e / DC-12 I e / DC-13 - at 24 V A 10 10 - at 48 V A 6 4 - at 110 V A 4 1 - at 220 V A 1 0.4 - at 440 V A 0.5 0.2 Short circuit protection 1 ), DIAZED fuse links Operational class gl/gg A 6 Quick response characteristic A 10 Mechanical endurance > 1 x10 6 operating cycles Electrical endurance With 3RH11, > 1 x10 6 operating cycles 3RT10 16 to 3RT10 26 contactors For AC-15 duty 0.5 x10 6 operating cycles when interrupting I e / AC-15 at 230 V For DC-13 duty With DC the contact endurance depends not only on the breaking current but also on the voltage, the circuit inductance and the speed of switching. No generally valid information can be given. Operating frequency 6 x10 3 operating cycles/h with 3RH11, 3RT10 16 to 3RT10 26 contactors Type 3SE2 200 3SE3 200 1) Without any welds according to IEC 60947-5-1. 3SE2 243, 3SE2 257 3SE2 120 Enclosure Fiber-glass strengthened thermoplastic Aluminum (GD - AlSi 12) Degree of protection acc. to IEC 60529 IP65 IP67 IP67 Ambient temperature in operation 30... +85 C 35... +85 C for storage, transport Mounting position Any Cable entry 3SE2 200: 1 x (M 20 x 1.5) 1 x (M 20 x 1.5) or 1 x (M 16 x 1.5) 1 x (M 20 1.5) 3SE3 200: Pg 13/5 Conductor cross-sections Solid 2 x 2.5 mm² 1 x (0.5... 1.5 mm²), 2 x 2.5 mm² 2 x (0.5... 1 mm²) Finely stranded with end sleeve 2 x 1.5 mm² 1 x (0.5... 1.5 mm²), 2 x (0.5... 1 mm²) 2 x 1.5 mm² Protective conductor terminal inside enclosure M 3.5 13/41
3SE2 120 / 2SE3 170 Metal enclosure with separate actuator Selection and ordering data 2 or 4 contacts Moving double break contacts 1 ) 3 ) Actuation/Fixing Enclosure width/ length of actuator 3SE. position switches 3SE. position switches 3SE. position switches Wght. with 2 slow-action contacts with 2 slow-action contacts with 4 slow-action contacts ap. 6 mm stroke 6 mm stroke 6 mm stroke Ident. No. 11 Ident. No. 22 mm 1 unit 1 unit 1 unit kg Metal enclosure IP 67, EN 50 041 3SE2 120-0XX Side Entry 1 ) M 20 x 1.5 connecting thread 1/2 NPT connecting thread 4-pole M12 male receptacle 3SE2 120-0XX 3SE3 170-0XX 3SE2 120-0XX00-0AC4 87.00 92.00 123.00 3SE2 120-6XX 3SE3 170-6XX 3SE2 120-6XX00-0AC4 87.00 92.00 123.00 3SE2 120-4XX 3SE3 170-4XX - 92.00 92.00 0.350 0.350 0.360 Actuator Standard 79 3SX3 197 13.00 0.027 With transverse mounting For lateral 50 50 3SX3 206 3SX3 306 13.00 13.00 0.025 0.025 mounting Universal radius actuator Approach from the left 80 132 3SX3 203 3SX3 207 77.00 14.00 0.113 0.085 Operation, operating speed and travel Actuator Operation by a separate bar Switch blocks Nominal travel and related terminals v max max. operating speed direction of operation Radius actuation: for all approach directions Internal circuit diagram Terminal designation contact closed contact open Actuator in actuator head; NC is closed Separate actuator Slow-action contacts perpendicular to plunger axis Side operation 3SE2 120.XX / 3SE3-170.XX v max = 1 m/s 1 NO + 1 NC Minimum force required in operating direction on retraction 10 N Ident. No. 11 2 NC 2 NO + 2 NC Ident. No. 22 Wiring Diagram for M12 Connection Interlock Switch, 4-pole Connection Typical M12 Cable 1 ) M12 1 NO + 1 NC 2 NC 4-wire 4-pole Pin Connection Connection Connection Male 1 21 11 Brown Receptacle 2 22 12 White 3 13 21 Blue 4 14 22 Black 1) Typical 4-pole Female Plugs with black 5 meter cable: Right-angle: 3RX1542 Straight: 3RX1513 Positive opening acc. to IEC 60 947-5-1, Appendix K. 1) Supplied without actuator. 2) Radius actuator (universal): R min > 70 mm. 3) For conduit thread adaptors see page 13/97. 13/42 Discount Code: SIRIUS Safety Switches
3SE. 200 Molded plastic enclosure with separate actuator Selection and ordering data 2 contacts Moving double-break contacts 1 ) 2 ) Actuation/Fixing Enclosure width Length of actuator 3SE. position switches 3SE. position switches Wght. with 2 slow-action contacts with 2 slow-action contacts appr ox. 6 mm stroke 6 mm stroke Ident. No. 11 mm 1 unit 1 unit kg Molded plastic enclosure IP 65, EN 50 047 3SE2 200-0XX03 Side actuation 31 3SE2 200-0XX03 49.00 3SE2 200-6XX03 47.00 0.085 Top actuation 31 3SE2 200-0XX04 49.00 3SE2 200-6XX04 49.00 0.100 M 20 1.5 3SX3 196 Actuator Standard actuator 50 3SX3 196 4.00 0.016 70 3SX3 195 5.00 0.18 3SE3 200-0XX13 5 directions of approach 2 ) Pg. 13.5 31 3SE3 200-0XX13 49.00 3SE3 200-6XX13 49.00 0.109 3SX3 220 Actuator Standard 44 3SX3 220 5.00 0.013 With transverse actuation 36 3SX3 221 5.00 0.013 3SX3254 Radius actuator 44 3SX3 254 16.00 0.025 For operation, operating speed and travel, see Page 13/45. Positive opening acc. to IEC 60 947-5-1, Appendix K, and DIN VDE 0660 Part 200. 1) Supplied without actuator. 2) For conduit thread adaptors see page 13/97. Discount Code: SIRIUS Safety Switches 13/43
3SE. 243 / 3SE. 257 Molded plastic enclosure with separate actuator Selection and ordering data 1 contact 3 contacts Moving double-break contacts 1 ) 2 ) Actuation Enclosure width Length of actuator 3SE. position switches 3SE. position switches Wght. with 3 slow-action contacts with 1 slow-action contact appr ox. 6 mm stroke 6 mm stroke Ident. No. 12 Wght. Ident. No. 01 appro x. mm mm 1 unit kg 1 unit kg Molded plastic enclosure IP 67 3SE2 243-0XX Top and side entry 1 ) M20 x 1.5 connecting thread Extraction force 5 N 52 3SE2 243-0XX40 46.00 1.120 3SE2 257-6XX40 41.00 0.140 Extraction force 30 N 52 3SE2 243-0XX 46.00 1.120 3SE2 257-6XX 41.00 0.140 With automatic ejection 52 3SE2 243-0XX30 46.00 1.120 3SE2 257-6XX30 41.00 0.140 M16 x 1.5 connecting thread Extraction force 5 N 52 3SE2 243-0XX48 46.00 0.140 3SE2 257-6XX48 41.00 0.140 Extraction force 30 N 52 3SE2 243-0XX18 46.00 0.145 3SE2 257-6XX18 41.00 0.140 With automatic ejection 52 3SE2 243-0XX38 46.00 0.140 3SE2 257-6XX38 41.00 0.140 Actuator Standard actuator (r min. = 150 mm) 28 3SX3 218 5.00 0.022 Radius actuator (universal) (r min. = 45 mm) 33 3SX3 228 12.00 0.025 Ball catch (up to 100 N) 28 3SX3 217 29.00 0.037 Actuator with dust protector and slit cover (1 set) 34 3SX3 234 28.00 0.035 Radius actuator 82 3SX3 256 14.00 0.019 Accessories Slit cover only for 3SX3234 (1 set = 3 units) For operation, operating speed and travel, see Page 13/45. 3SX3 233 2.50 Positive opening acc. to IEC 60 947-5-1, Appendix K, and DIN VDE 0660 Part 200. 1) Supplied without actuator. 2) For conduit thread adaptors see page 13/97. 13/44 Discount Code: SIRIUS Safety Switches
3SE3 200 / 3SE. 243 / 3SE. 257 Molded plastic enclosure with separate actuator Operation, operating speed and travel Actuator Operation by a separate bar Switch blocks Nominal travel and related terminals v max max. operating speed direction of operation Radius actuation: for all approach directions Internal circuit diagram Terminal designation acc. to EN 50 013 contact closed contact open Actuator in actuator head; NC is closed Separate actuator 3SE2 200.XX03 3SE2 200.XX04 Slow-action contacts 1 NO+1 NC perpendicular to plunger axis front end operation Side actuation v max = 1.5 m/s for top operation Minimum force required in operating direction on retraction 10 N Identification number 11 Top actuation v max = 1 m/s 2 NC Actuator a b Short 42 to 45 66.5 to 69 Long 62 to 65 86.5 to 89 Top and side actuation (4 90 ) 3SE3 200.XX13 Side actuation 1 NO+1 NC 10 N Ident. No. 11 2 NC Horizontal actuation Top and side actuation 3SE2 243.XX.., 3SE2 257.XX.. 30 N or 5 N Ident. No. 12 Ident. No. 01 M20 x 1.5 1) Radius actuator: R min > 38 mm. 13/45
3SE. 200 Molded plastic enclosure with separate actuator Dimension drawings Molded plastic enclosure 3SE2 200-.XX03, side actuation 3SE2 200-.XX04, top actuation Permissible center offset of actuator to position switch: vertical and horizontal ±1 mm Actuator a b Short 42 to 45 66.5 to 69 Long 62 to 65 86.5 to 89 Radius actuation: for all radii 50 mm, lateral and front-end actuation Short actuator 3SX3 196 Long actuator 3SX3 195 3SE3 200-.XX13, 5 approach directions Radius actuation: for all radii 50 mm, lateral and front-end actuation Standard actuator 3SX3 220 Actuator for transverse mounting 3SX3 221 Radius actuator 3SX3 254 13/46
3SE3 120 / 3SE. 243 / 3SE. 257 Metal / molded plastic enclosure with separate actuator Dimension drawings Metal enclosure 3SE. 120-.XX / 3SE3-170-.XX side entry Actuator 3SX3 197 for lengthwise actuation Actuator 3SX3 206 for transverse actuation Universal radius actuator 3SX3 203 9 5 Molded plastic enclosure 3SE2 243, side and top actuation, with standard actuator 3SX3 218 3SE2 257, side and top actuation Universal radius actuator 3SX3 228 Ball catch 3SX3 217 M20 13/47