Eaton 93PM UPS 30 200 kw Class-leading energy efficiency with minimal operating cost August 2013 2013 Eaton. All rights reserved.
Eaton 93PM UPS Content Introduction to Eaton 93PM Overview Lowest Total Cost of Ownership Scalability and reliability Ease of deployment Ease of management 2 2
Eaton 93PM UPS - Overview Class Leading Features Efficiency: 96.7%(On-Line) >99%(ESS) KVA=KW Longest Back-up time of >10min at 50KW Scalable, modular design Touch-Screen display 50kW module 50kW module 50kW module 50kW module SS SS (200kW) (150kW) 50kW module 50kW module 50kW module 50kW module SS SS (200kW) 50kW module Batteries Batteries Batteries 50kW module 50kW module 150kW 200kW Batteries Batteries Batteries SS (200kW) (50kW) SS (200kW) (100kW) 50kW 100kW 2013 Eaton. All rights reserved. 3 3
Eaton 93PM UPS 30KW 50KW The building block is a 30-50kW uninterruptible power module (UPM) When there s only one module, the frame has space for internal batteries 4 4
Eaton 93PM 30-50 kw Taking a closer look at the unit 5 5
Eaton 93PM 30-50 kw Taking a closer look the UPS functional core Uninterruptible power module (UPM) Highest reliability with double conversion topology Rectifier Inverter Battery converter Top-of-market efficiency with multilevel converter technology Rectifier input switch Allows easy isolation of UPM when operating or servicing the system System static bypass switch Has dedicated MCU to boost reliability and system availability With intelligent ESS technology allows increasing to top 99% 6 6
Eaton 93PM 30-50 kw Taking a closer look the UPS stored energy Battery start Start up to battery when utility is not available Battery breaker Protective device for internal batteries UPS battery Internal batteries reduce the footprint of the complete system 7 7
Eaton 93PM 30-50 kw Taking a closer look Switchgear and wiring Rectifier input switch Allows easy isolation of UPM Battery breaker Protective device for internal batteries System maintenance bypass switch (MBS) Internal MBS reduces need for external expensive switchgear solutions Allows servicing the UPS without de-energizing system output and shutting off load Input, output and battery wiring terminals Dual feed increases system availability Rectifier and bypass input (dual feed!) Easy connection of external battery rack or cabinet 8 8
Eaton 93PM UPS 30-50 kw Taking a closer look Switchgear and wiring 9 9
Eaton 93PM UPS The building block is a 30-50kW uninterruptible power module (UPM) By paralleling the modules internally, we get ratings of 2x 40kW = 80kW 2x 50kW = 100kW 3x 40kW = 120kW 3x 50kW = 150kW 4x 40kW = 160kW 4x 50kW = 200kW Static bypass size is chosen according to system power 10 10
Eaton 93PM UPS 100-200 kw Taking a closer look Switchgear and wiring 11 11
Lowest Total Cost of Ownership Eaton 93PM minimises power and cooling OPEX through industry leading energy efficiency > 99% efficiency with Energy Saver System (ESS) Up to 97% efficiency in double conversion Internal scalability allows pay as you grow Internal redundancy reduces the need for additional UPS Space-saving and compact 12 12
Lowest Total Cost of Ownership Eaton 93PM minimises power and cooling OPEX through industry leading energy efficiency > 99% efficiency with Energy Saver System (ESS) Up to 97% efficiency in double conversion 13 13
Lowest Total Cost of Ownership Energy Saver System When mains power quality is high, the load can be powered through the static bypass line >99% operating efficiency from 40% load and up Component lifetime will increase (capacitors, electronics) Less audible noise 2013 Eaton. All rights reserved. 14 14
Lowest Total Cost of Ownership Energy Saver System UPMs in ready state mode Input and output relays (K1 & K3) are closed DC link is energised Continuous monitoring of UPS output voltage Inverters synchronised to bypass, but not gating The UPS is able to transfer to double conversion mode in less than 2 ms 2013 Eaton. All rights reserved. 15 15
Eaton 93PM UPS Advanced battery management (ABM) ABM charging algorithm prolongs battery service life Load adaptive battery cut-off voltage optimises system battery set-up to the actual load 16 16
Scalability and Reliability 2010 Eaton Corporation. All rights reserved.
Scalability and reliability By combining vertical and horizontal paralleling, the system size can be increased further 2013 Eaton. All rights reserved. 18 18
Scalability and reliability Internal scalability True internal redundancy Scales up in 50 kw increments Centralised UPS bypass that is fully rated in Day1 Maximised selectivity combined with flexibility Hot Sync technology for reliable horizontal and vertical paralleling Each UPM in the system operates independently 2013 Eaton. All rights reserved. 19 19
Scalability and reliability The maximum system size reaches around 1 MW of UPS capacity 2013 Eaton. All rights reserved. 20 20
Ease of deployment 2013 Eaton. All rights reserved. 21 21
Ease of Deployment Against-the-wall configuration utilising a Top-airexhaust kit Front-to-back airflow is optimal for hot/cold aisle configurations Maximises deployment flexibility by providing innovative thermal management options. 2013 Eaton. All rights reserved. 22 22
Ease of Management 2013 Eaton. All rights reserved. 23 23
Ease of Management Top-class intelligent software solutions Web interface as standard Integration to IT and management systems with SNMP Intelligent Power Software bundled Monitor and manage your UPS system as an integral part of power and IT infrastructure Web-based interface allows monitoring of multiple UPS through any device with a browser Link to virtualisation management systems (vcenter, XenCenter, Systems Center) Migrate virtual machines to other sites in case of power failure 24 24
Ease of Management Monitor system status information visually 25 25
Ease of management: LED status bars The green/yellow/red LED light-bars make system status visible from a distance in data centers. Green LED s -> System online and normal. Yellow LED s -> System on battery or bypass. Red LED s -> Service required. 2013 Eaton Corporation. All rights reserved. 26 26
Ease of Management Sofware communications & Connectivity Three MiniSlots for additional connectivity hardware Host and device USB port Five building alarm inputs and dedicated EPO Relay alarm output (more available as option) 27 27
Network Card-MS Web/SNMP Software support: Intelligent Power Manager, Intelligent Power Protector NSM, NetWatch 5 LanSafe (requires settings in card) Other features: Email alarms Temperature, humidity and 2 status inputs through Environment Sensor (optional) SNMP v 3, IP v 6 SNMP with Pulsar MIB, Power MIB and standard UPS MIB (RFC 1628) Network and Modbus card MS (successor of inmc 66103) provides ModBus RTU Note: MODBUS-MS does not have 93PM support at FCS 28 28
Relay/Serial card (Relay-MS) Connections to automation and monitoring systems Integration to building management systems IBM AS/400 shutdown Works with all MiniSlot UPS (not 9130) Could be used as a RS232 card DB9 connector 29 29
Eaton 93PM UPS Summary Introduction to Eaton 93PM Lowest Total Cost of Ownership Scalability and reliability Ease of deployment Ease of management 30 30
2013 Eaton. All rights reserved. 31 31