Similar documents
PanelView 600 Terminals

Installation Instructions

PanelView Component HMI Terminals

Integrated Display Computers

Installation Instructions

Adapter Kit for PanelView 1200/1200e Touch Screen Terminal Cutout

VersaView 1200P Integrated Display Computers for Hazardous Locations

Wiring and Grounding Guidelines for PanelView Plus Terminals

Installation Instructions

CompactLogix Power Supplies Specifications

*Approved by CSA for non-hazardous locations (Group Safety Publication IEC Third Edition).

InView Marquee Message Display

Digital ac/dc (24V) Input Module

Installation Instructions

VersaView Industrial Non-display Computers

Embedded I/O Expansion Board with 10 Outputs

PACSystems RX7i IC698CHS009/119

FLEX Ex Spring Clamp Terminal Base

CompactBlock Guard I/O EtherNet/IP Safety Modules

ArmorPoint I/O Field Potential Distributor, Series A

PM Series Power Meter

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

PHOENIX CONTACT - 07/2006

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

ControlLogix Redundant Power Supply Chassis Adapter Module

Installation Instructions

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)

ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)

ATS01N232RT soft starter for asynchronous motor - ATS01-32 A V

LXM32SD18M2 motion servo drive - Lexium 32-single phase supply voltage 115/230V - 0.5/1.kW

QUINT-PS/ 1AC/24DC/ 5

ATS01N206RT soft starter for asynchronous motor - ATS01-6 A V

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

Installing the Tracer MP503 Input/Output Module Ordering number: ,

TU531, TU532 Terminal Unit

Redundancy unit CP-A RU

LXM32AD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h

DANGER DANGER: is used in this manual to warn of high voltages capable of causing shock, burns, or death.

Installation Instructions

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

Power supply CP-C 24/5.0

ATS22D47S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

SAFETY, ENVIRONMENTAL, AND REGULATORY INFORMATION. NI CompactDAQ Four-Slot Controller with Quad-Core Processor

CPCI-PS24 24V-Power Supply

QUINT-PS AC/24DC/10

Installation Requirements for Conformance to Standards

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

Operating Instructions 12/2010 MN Z-EN XV-152 MICRO PANEL

Analog Voltage Combination Module

AO523 Analog Input Module

TRIO-DIODE/12-24DC/2X10/1X20

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

MINI-PS AC/10-15DC/8

ETD-BL-1T-OFF-CC- 10S

SLATE. Digital I/O Module INSTALLATION INSTRUCTIONS R8001D4001

Integrated Display Computer with Keypad

Power supply module, bus connection module

Bulletin 290/291 ArmorStart LT Distributed Motor Controllers Specifications

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Zener Barriers Bulletin 937Z

em4 Accessories Digital expansions

ATS22C21S6U softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp)

PV Rapid Shutdown device

COMPACT LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , ,

ATS22C17Q. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

Installation Instructions

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

CC COMPACT DIP SWITCH

F1000 User's Manual. (Version: V1.01)

PCI 2 Axis Servo Card

COMPACT LED CONVERTERS 48 V

TF501, TF521 Terminal Bases

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100hp)

PowerLogic High Density Metering System 1-Meter Enclosure

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

SECTION SWITCHBOARDS

Remote I/O Scanner. Installation Instructions. (Catalog Number 1747-SN)

HMIGK5310 Keypad-touchscreen panel color x 480 pixels VGA -10.4" - TFT LCD

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:

PCI 2 Axis Servo Card

Application Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60

AX522 Analog Input/Output Module

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

Power Supply HARTING pcon

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

DeviceNet ArmorBlock Network Powered 16-input Module

COMPACT LED DRIVERS. ComfortLine Residential. ComfortLine RESIDENTIAL , , ,

MT-8000 series. MT-8056T/ MT-6056T Installation Instruction. 1.0 Installation and Startup Guide. 2.0 Installation Instructions

Temperature. Power requirements. Weight. Dimensions

SECTION TRANSIENT VOLTAGE SUPPRESSION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS

Transcription:

Installation Instructions PanelView Plus/VersaView CE Terminals and Display Modules (Catalog Numbers 2711P-xxxxxx, 6182H-xxxxxx) English Inside: Overview...2 For More Information...2 Modular Components...3 Wiring and Safety Guidelines...4 Hazardous Locations...5 Environmental Considerations...6 Enclosures...6 Clearances...6 Required Tools...6 Mounting Dimensions...7 Cutout Dimensions...9 Installing Terminal in a Panel...10 Connecting DC Power...12 European Communities (EC) Directive Compliance...13 Product Specifications...14

2 PanelView Plus/VersaView CE Terminals and Display Modules Overview This document provides instructions on how to install the following devices in a panel or enclosure. factory assembled PanelView Plus or VersaView CE terminal PanelView Plus or VersaView CE Display Module Refer to the installation instructions shipped with the Logic Module and Communiction Module for field installation of these components. For More Information To obtain electronic versions of the PanelView Plus or VersaView CE User Manual, visit the following web sites: www.theautomationbookstore.com www.ab.com/manuals

PanelView Plus/VersaView CE Terminals and Display Modules 3 Modular Components The PanelView Plus and VersaView CE terminals have the following modular components: Display Module (700/700H, 1000/1000H, 1250/1250H, 1500/1500H) Logic Module (DC Power, CF Card Slot, Ethernet Port, Serial Port, USB Ports) Internal Compact Flash card with firmware or operating system, RAM Memory (SO-DIMM) Communication Module (for specific communication protocols) These items can be ordered as separate components for field installation or factory assembled per your configuration. The base configured unit includes the Display Module and the Logic Module (with Internal Compact Flash and RAM). Logic Module Communication Module DC Power Input Display Module Compact Flash Card Slot USB Ports Ethernet Port Serial Port If the modules are ordered separately, attach the Logic Module and Communication Module) to the Display Module before panel installation. See instructions shipped with each module. The VersaView CE terminal is shipped with RAM and Compact Flash pre-installed in Logic Module. The RAM and Compact Flash are not pre-installed in the Logic Module of the PanelView Plus. You must install the memory before attaching the Logic Module to Display Module. See instructions shipped with Logic Module.

4 PanelView Plus/VersaView CE Terminals and Display Modules Wiring and Safety Guidelines Use publication NFPA 70E, Electrical Safety Requirements for Employee Workplaces when wiring the terminals. In addition to the NFPA guidelines: connect the terminal and other similar electronic equipment to its own branch circuit protect the input power by a fuse or circuit breaker rated at no more than 15 Amps. route incoming power to the terminal by a separate path from the communication lines. where power and communication lines must cross, they should cross at right angles. Communication lines can be installed in the same conduit as low level DC I/O lines (less than 10 volts). grounding minimizes noise from Electromagnetic Interference (EMI) and is a safety measure in electrical installations. To avoid EMI, shield and ground cables appropriately. A source for grounding recommendations is the National Electrical Code published by the National Fire Protection Association of Boston.

PanelView Plus/VersaView CE Terminals and Display Modules 5 Hazardous Locations This equipment is suitable for: Class I, Division 2 Groups A, B, C, D Class II, Division 2 Groups F, G Class III Division 1 or non-hazardous locations only The following statement applies to use in hazardous locations. WARNING! Explosion Hazard Substitution of components may impair suitability for hazardous locations. Do not disconnect equipment unless power has been switched off and area is known to be non-hazardous. Do not connect or disconnect components unless power has been switched off. All wiring must comply with N.E.C. articles 501-4(b), 502-4(b), 503-3(b) as appropriate. Peripheral equipment must be suitable for the location it is used in. The PanelView Plus and VersaView CE terminals have an operating temperature code of T4 (maximum operating temperature of 55 C or 131 F). Do not install the terminals in environments where atmospheric gases have ignition temperatures less than 55 C or 131 F.

6 PanelView Plus/VersaView CE Terminals and Display Modules Environmental Considerations The terminals are suitable for use in an industrial environment when installed in accordance with these instructions. Specifically, this equipment is intended for use in clean, dry environments (Pollution Degree 2 (1) and with circuits not exceeding Over Voltage Category II (2) (IEC 60664-1). (3) (1) Pollution Degree 2 is an environment where, normally, only non-conductive pollution occurs except that occasionally a temporary conductivity caused by condensation shall be expected. (2) Over Voltage Category II is the load level section of the electrical distribution system. At this level transient voltages are controlled and do not exceed the impulse voltage capability of the product s insulation. (3) Pollution Degree 2 and Over Voltage Category II are International Electrotechnical Commission (IEC) designations. Enclosures The terminals must be mounted in a panel or enclosure to protect the internal circuitry. The terminals meet NEMA Type 12/13 and 4X ratings only when mounted in a panel or enclosure with the equivalent rating. When the terminal is not mounted in a panel, it is not secure or safe for operation. You must comply with the NEMA Type 4 requirements for environmental specifications. Clearances Allow adequate clearances around the terminal, inside the enclosure, for adequate ventilation. Consider heat produced by other devices in the enclosure. The ambient temperature around the terminals must be between 0 55 C (32 131 F). Minimum clearances for ventilation are: top and bottom clearance: 51 mm (2 in) side clearances: 25 mm (1 in) Maximum side clearance for insertion of memory card is 102 mm (4 in). Required Tools Besides the tools required for the panel or enclosure cutouts, you will need the following for installation: small slotted screw driver torque wrench (in-lb)

PanelView Plus/VersaView CE Terminals and Display Modules 7 Mounting Dimensions This section provides mounting dimensions for the PanelView Plus and VersaView CE terminals. The depth dimensions are shown for the: base unit including Display Module and Logic Module base unit with Communication Module All measurements are in mm (inches). The illustration following the table shows dimensions for the 1000/1000H terminals. Terminal Type Height Width Depth PanelView Plus 700/VersaView CE 700H Keypad orkeypad & Touch PanelView Plus 700/VersaView CE 700H Touch Screen PanelView Plus 1000/VersaView CE 1000H Keypad orkeypad & Touch PanelView Plus 1000/VersaView CE 1000H Touch Screen PanelView Plus 1250/VersaView CE 1250H Keypad or Keypad & Touch PanelView Plus 1250/VersaView CE 1250H Touch Screen PanelView Plus 1500/VersaView CE 1500H Keypad or Keypad & Touch PanelView Plus 1500/VersaView CE 1500H Touch Screen 193 (7.58) 290 (11.40) 179 (7.04) 246 (9.68) 248 (9.77) 399 (15.72) 248 (9.77) 329 (12.97) 282 (11.12) 416 (16.36) 282 (11.12) 363 (14.30) 330 (12.97) 469 (18.46) 330 (12.97) 416 (16.36) 55 (2.18) Display to Logic Module 83 (3.27) Display to Comm Module 65 (2.55) Display to Logic Module 93 (3.65) Display to Comm Module

8 PanelView Plus/VersaView CE Terminals and Display Modules PanelView Plus and VersaView CE 1000 All measurements are in mm (inches). 1000 Keypad or Keypad & Touch 248 (9.77) 399 (15.72) a 55 (2.18) Display to Logic Module b 83 (3.27) Display to Comm Module a b 1000 Touch 248 (9.77) 329 (12.97) a 55 (2.18) Display to Logic Module b 83 (3.27) Display to Comm Module a b

PanelView Plus/VersaView CE Terminals and Display Modules 9 Cutout Dimensions The table below shows the overall cutout dimensions for each PanelView Plus and VersaView CE terminal. Dimensions are in mm (inches). Use the full size template shipped with your terminal to mark the cutout dimensions. PanelView Plus /VersaView CE Terminal Height Width 700/700H Keypad or Keypad & Touch 167 (6.57) 264 (10.39) 700/700H Touch 154 (6.08) 220 (8.67) 1000/1000H Keypad or Keypad & Touch 224 (8.8) 375 (14.75) 1000/1000H Touch 224 (8.8) 305 (12.00) 1250/1250HKeypad or Keypad & Touch 257 (10.11) 390 (15.35) 1250/1250H Touch 257 (10.11) 338 (13.29) 1500/1500H Keypad or Keypad & Touch 305 (12.00) 419 (16.50) 1500/1500H Touch 305 (12.00) 391 (15.40)

10 PanelView Plus/VersaView CE Terminals and Display Modules Installing Terminal in a Panel All of the PanelView Plus and VersaView CE terminals are installed in the same manner using clips for mounting. The number of clips used (4, 6 or 8) varies by terminal type. The mounting clips are shipped with each terminal. ATTENTION! Disconnect all electrical power from the panel before making the panel cutout. Make sure the area around the panel cutout is clear. Do not allow metal cuttings to enter any components already installed in the panel. Failure to follow these instructions may result in personal injury or damage to panel components. To install a terminal in a panel: 1. Cut an opening in the panel using the panel cutout provided with the terminal. Remove any sharp edges or burrs. 2. Make sure the terminal sealing gasket is properly positioned on the terminal as shown. This gasket forms a compression type seal. Do not use sealing compounds. Sealing Gasket 3. If using keypad legend strips on keypad terminals, we recommend that you install the strips before installing the terminal. Be careful not to pinch legend strip during installation. 4. Place the terminal in the panel cutout.

PanelView Plus/VersaView CE Terminals and Display Modules 11 5. Install the mounting clips. The ends of the clips slide into the slots on the terminal. Mounting ClipSlot Mounting Clip 6. Tighten the clip mounting screws by hand until the gasket seal contacts the mounting surface uniformly. 7. Alternately tighten the mounting clips screws to a torque of.90-1.1 N m (8-10 in-lb). Do not over-tighten. Below are recommended torque sequences. 1 4 1 5 3 1 6 4 Clips 3 2 6 Clips 4 2 6 3 7 5 8 Clips 2 8 4 ATTENTION! Tighten the mounting clip screws to a torque of.90-1.1 N m (8-10 in-lb) to provide a proper seal and to prevent potential damage to the terminal. Allen-Bradley assumes no responsibility for water or chemical damage to the terminal or other equipment within the enclosure because of improper installation.

12 PanelView Plus/VersaView CE Terminals and Display Modules Connecting DC Power The PanelView Plus and VersaView CE terminals have an integrated power supply that operates on 24V dc. The electrical input ratings of the power supply are: 24V dc nominal (18 32V dc) 70 Watts maximum (2.9A @24V dc) The power supply is internally protected against reverse polarity. The input power, terminal block on the power supply is removable and supports the following wire sizes: Wire Type Wire Size Terminal Block Screw Torque Stranded Solid #16 to #22 AWG #18 to #22 AWG.23 -.45 N m (2-4 in-lbs) The terminals using 24V dc power are EN 61131-2 Equipment Class II devices. ATTENTION! Use a SELV (Safety Extra-Low Voltage), isolated and ungrounded power supply as input power to the terminals. This power source provides protection so that under nominal and single fault conditions, the voltage between conductors and between conductors and Functional Earth/Protective Earth does not exceed a safe valve. To connect DC power: 1. Secure the DC power wires to the terminal block screws. 2. Secure the Functional Earth (FE) ground wire to the terminal block screw. 3. Apply 24V dc power to the terminal. Logic Module with DC Power Input Functional Earth Ground - DC Negative + DC Positive

PanelView Plus/VersaView CE Terminals and Display Modules 13 European Communities (EC) Directive Compliance If this product has the CE mark it is approved for installation within the European Union and EEA regions. It has been designed and tested to meet the following directives. EMC Directive This product is tested to meet the Council Directive 89/336/EC Electromagnetic Compatibility (EMC) by applying the following standards, in whole or in part, documented in a technical construction file: EN 50081-2 EMC - Generic Emission Standard, Part 2 - Industrial Environment EN 61000-6-2 EMC - Generic Immunity Standard, Part 2 - Industrial Environment This product is intended for use in an industrial environment. Low Voltage Directive This product is tested to meet Council Directive 73/23/EEC Low Voltage, by applying the safety requirements of EN 61131-2 Programmable Controllers, Part 2 - Equipment Requirements and Tests. For specific information required by EN 61131-2, see the appropriate sections in this publication, as well as the Allen-Bradley publication Industrial Automation Wiring and Grounding Guidelines For Noise Immunity, publication 1770-4.1. Open style devices must be provided with environmental and safety protection by proper mounting in enclosures designed for specific application conditions. See NEMA Standards publication 250 and IEC publication 529, as applicable, for explanations of the degrees of protection provided by different types of enclosure.

14 PanelView Plus/VersaView CE Terminals and Display Modules Product Specifications Electrical DC Power Input Voltage DC Power Consumption DC 24V dc nominal (18 32V dc) 70 Watts maximum (2.9 A @24V dc) Display Display Type Display Size 700/700H 1000/1000H 1250/1250H 1500/1500H Display Area (W x H) 700/700H 1000/1000H 1250/1250H 1500/1500H Display Resolution 700/700H 1000/1000H 1250/1250H 1500/1500H Touch Screen Color Active Matrix, Thin FilmTransistor (TFT), with Liquid Crystal Display (LCD) 6.5 in 10.4 in 12.1 in 15 in 132 x 99 mm (5.2 x 3.9 in) 211 x 158 mm (8.3 x 6.2 in) 246 x 184 mm (9.7 in x 7.2 in) 304 x 228 mm (12.0 x 9.0 in) 640 x 480 640 x 480 800 x 600 1024 x 768 Analog Resistive Environmental Operating Temperature Storage Temperature Vibration Shock Operating Shock Non-Operating Relative Humidity Ratings 0 55 C (32 131 F) -20 70 C (-13 158 F) 10 57 Hz, 0.012 pk-pk displacement 57 500 Hz 2.0 g pk accelertation 15 g at 11 ms 30 g at 11 ms 5 95% without condensation NEMA Type 12, 13, 4X (indoor use only), IP54, IP65

PanelView Plus/VersaView CE Terminals and Display Modules 15 Mechanical Dimensions H x W x D (for base configured unit without communication module) 700/700H Keypad or Keypad & Touch 193 x 290 x 55 mm (7.58 x 11.40 x 2.18 in) 700/700H Touch 179 x 246 x 55 mm (7.04 x 9.68 x 2.18 in) 1000/1000H Keypad or Keypad & Touch 248 x 399 x 55 mm (9.77 x 15.72 x 2.18 in) 1000/1000H Touch 248 x 329 x 55 mm (9.77 x 12.97 x 2.18 in) 1250/1250H Keypad or Keypad & Touch 282 x 416 x 55 mm (11.12 x 16.36 x 2.18 in) 1250/1250H Touch 282 x 363 x 55 mm (11.12 x 14.30 x 2.18 in) 1500/1500H Keypad or Keypad & Touch 330 x 469 x 65 mm (12.97 x 18.46 x 2.55 in) 1500/1500H Touch 330 x 416 x 65 mm (12.97 x 16.36 x 2.55 in) Weight (for base configured unit without communication module) 700/700H Keypad or Keypad & Touch 1.9 kg (4.2 lb) 700/700H Touch 1.7 kg (3.8 lb) 1000/1000H Keypad or Keypad & Touch 2.9 kg (6.3 lb) 1000/1000H Touch 2.6 kg (5.7 lb) 1250/1250H Keypad or Keypad & Touch 3.4 kg (7.6 lb) 1250/1250H Touch 3.2 kg (7.1 lb) 1500/1500H Keypad or Keypad & Touch 4.6 kg (10.0 lb) 1500/1500H Touch 4.2 kg (9.3 lb) Agency Certifications When product is marked: Marked for all applicable directives UL Listed Industrial Control Equipment UL Listed Industrial Control Equipment for use in Canada UL Listed Industrial Control Equipment for use in Class I, Div 2, Group A, B, C, D Class II, Div 2 Groups F, G Class III, Div 1 Hazardous Locations Marked for all applicable acts N223

- December 2002 PN 41061-261-01(1) Copyright 2002 Rockwell Automation. All rights reserved. Printed in the U.S.A.