User s Manual. Model and Sound Level Calibrators

Similar documents
User's Guide. Model Laser Photo Tachometer

User's Guide. Video Borescope. Model BR100

User's Manual. Model Heavy Duty Datalogging Module with Windows Software

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage

Heavy Duty Datalogger Module

User Guide. Moisture Meter. Model MO250

Heavy Duty Datalogger Module

True RMS AC Voltage/Current Datalogger

User's Guide. Datalogging Light Meter with PC Interface. Model

User's Guide. Cup Thermo-Anemometer. Model AN400

User's Guide. Phase Sequence and Motor Rotation Tester Model

User s Guide. 600A AC Clamp Meter. Model 38387

User's Guide. Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer. Patented

User's Manual Sound Level Alert Model SL130

Digital Vane Thermo-Anemometer Model

Mini Photo Tachometer Model Mini Contact Tachometer Model

User's Guide. Model High Precision Quad Output DC Power Supply

Laser Photo/ Contact Tachometer. m/min. ft/min

User's Guide. Digital Sound Level Meter. Model

User's Guide. Hot Wire Thermo-Anemometer Model

User's Guide. Power Analyzer Model Power Analyzer Datalogger Model Introduction

User's Guide. Extech AM A AC Analog Clamp Meter

User Guide. Heavy Duty Differential Pressure Manometer. Model HD750

Heavy Duty Vibration Meter

User Guide. ExStik TM Model RE300 Waterproof ORP Meter. Patent Pending RE300 ORP

Heavy Duty Datalogging Light Meter

User's Guide. Heavy Duty Differential Pressure Manometer. Model

Heavy Duty Mini Vane CFM Thermo Anemometer

Heavy Duty CFM Thermo-Anemometer Model

Digital Sound Level Meter

User's Guide Video Borescope Model BR200

3-Axis G-Force Datalogger

User's Guide. Hot Wire Thermo-Anemometer Model Introduction

Integrating Sound Level Datalogger Model

User's Guide. Vibration Meter and Laser Combination Tachometer Model

User's Guide. Heavy Duty Vane Thermo-Anemometer. Model

User's Guide. 1/16 th DIN ph Controller. Model 48PH2. Introduction

User's Guide. Temperature / Humidity Datalogger. Model 42270

Power Analyzer Datalogger Model

User's Guide. Vane Thermo-Anemometer Datalogger. Model Introduction

User Guide. Model Temperature Datalogger Kit Model Temperature and Humidity Datalogger Kit Model SW276 Datalogging Software SW276

User Guide. ExStik FL700. Fluoride Meter

User's Guide. Programmable DC Power Supply 200 Watt (40 Volts / 5 Amps) Model Introduction

User's Guide. MiniTec TM Series Model MN25 MultiMeter

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

User's Guide. Model Noise Dosimeter with PC Interface. Introduction

SuperHeat Psychrometer Models RH350 and RH355 (kit)

User's Manual. Digital Sound Level Meter. Model

User's Guide. Mini Microscope. Model MC108

INSTRUCTION MANUAL. Model Dual Input RTD Thermometer. Measures two temperatures simultaneously. Dual RTD probe inputs

Heavy Duty Psychrometer + IR Thermometer Model HD500

Hygro Thermo-Anemometer Model

Mini Digital Multimeter

Oyster Meter ph-conductivity-tds-salinity-orp(mv)

APO F T1 F T1-T2 ESC - 0 ENTER. [Limits] CLR? SET[ ] LOG READ SAVE READ SHIFT [OFS] [APO] MAX/MIN REL HOLD [TIME] T1-T2 TYPE T1/T2 TYPE T1/T2

Autoranging Multimeter plus IR Thermometer Extech 450 Patented

Autoranging Mini Multimeter Model MN16A

Dual Input, 3-Display Thermometer/Datalogger Model

Personal Sound Level Meter

CONTENTS Safety Information Description Features Specifications Nomenclature And Function Operating Preparation Calibration Procedure

User s Manual. Models Digital Force Gauge. Additional User Manual Translations available at

SOUND LEVEL PEN INSTRUCTION MANUAL SPER SCIENTIFIC

Sound Level Pen Instruction Manual

DIGITAL SOUND LEVEL METER. Instruction Manual

User's Manual. CFM/CMM Thermo Anemometer + InfraRed Thermometer. Model AN200 UNITS NEXT AREA RECALL. cf m/cmm Anemometer Thermometer AN200

Digital Sound Level Meter

User's Guide. True RMS Multimeter plus IR Thermometer. Extech 470 Patent Pending

User's Guide. Heavy Duty Conductivity / Temperature. Model Introduction

LCT-1 User manual_v1_2017_03_30. LCT-1 Ultimate. Load Cell Tester Issue: Revision A User s Guide

Mini Sound Meter. Instruction Manual SPER SCIENTIFIC

MTP INSTRUCTION MANUAL

SM-10 SM-20-A. Sound Level Meters. Users Manual. For detailed specifications and ordering info go to

Digital Sound Level Meter

EXT-DVI-FM1000P User Manual

Sound Level Meter SD Card real-time Datalogger

User's Guide Extech EX840 True RMS 1000 Amp Clamp Meter with IR Thermometer

User s Guide. ExTERM Software for Model RH520 Humidity/Temperature Chart Recorder. Introduction. Software Installation

Owner s Manual. MWBPT UHF 100 Frequency Wireless Belt Pack Transmitter. MWBPT Wireless Belt Pack Transmitter. AtlasIED.com

Heavy Duty Hot Wire CFM Thermo-Anemometer

Datalogging Hygro-Thermometer

V-9908 MESSAGE/PAGE PANEL

Owner s Manual. MWHHM UHF 100 Frequency Wireless Handheld Microphone. MWHHM Wireless Handheld Microphone. AtlasIED.com

Handheld Laser Particle Counter. Model: P311. Operation Manual. Ver: 1.50 AIRY TECHNOLOGY INC

Fruit Hardness Tester

Digital Sound Level Meter MODEL

USER GUIDE. 3 Channel DC Current Datalogger Model SD900

Video Borescope Inspection Camera

USER MANUAL. Light Meter. Model LT510. Additional User Manual Translations available at

PUNCH FACTORY OPTICAL COMPRESSOR

1:4 Splitter for DisplayPort

WIR RX15-2 Receiver MHz or 2.8 MHz

12-Channel Thermocouple Datalogger

INFRARED WIRELESS HEADPHONES

MTP INSTRUCTION MANUAL

Heavy Duty Vibration Meter

3 Channel Datalogging Thermometer

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasSound.com

Carefree-Security. Installation and programming instructions 1050A. Owner s Manual

Global Water Instrumentation, Inc.

Barometric Pressure / Humidity and Temperature Datalogger

Transcription:

User s Manual Model 407744 and 407766 Sound Level Calibrators

Introduction Congratulations on your purchase of Extech s Sound Level Calibrator. Extech Calibrators accommodate Sound Level Meters with 0.5 and 1 microphones. The Calibrator s die-cast aluminum housing is built for ruggedness and durability. The 407744 provides a 94dB calibration output signal while the 407766 provides both 94dB and 114dB outputs. This professional calibrator, with proper care, will provide years of safe reliable service. Specifications Output signals 407744: 94dB 407766: 94dB and 114dB Output signal accuracy 407744: ± 0.5dB; 407766: ± 0.5dB (94dB), ±1.0dB (114dB) Output signal frequency 1KHz sine wave Accuracy of output signal frequency ± 5% Compatible microphones sizes 0.5 and 1 microphones Total Harmonic Distortion (THD) <2%@94dB, <5%@114dB (407766) Operating temperature 32 to 122 o F (0 to 50 o C) Power supply Two (2) 9V batteries Power consumption Approx. 10mA DC Battery check Status LED Dimensions 2.2 diameter x 5.6 length (50 x 127mm) Weight 0.75 lbs. (340g) Standards meets IEC 60942 1997-11 class 2 Standards Meets IEC 60942 1997-11 class 2 2 407744 & 407766 - V5.1 04/10

Description Note that only the 407766 is pictured. 1. ½ Microphone adaptor * 4 2. 407766: OFF-94dB-114dB switch 407744: OFF-BATTERY TEST-94dB switch 3. 407766: POWER-ON / LOW-BATTERY status LED 407744: BATTERY OK LED 4. Battery compartment cap 3 2 1 * To remove the ½ adaptor, pull straight down as shown in diagram below. 3 407744 & 407766 - V5.1 04/10

Operation Theory of Operation The 407744 sound level calibrator generates a 94dB sine wave at 1 KHz. The 407766 generates a 94dB and a 114dB sine wave at 1kHz. When a microphone from a sound level meter is inserted into the calibrator, the sound level meter picks up the signal and displays the signal in db (decibel) units. The sound level meter should be adjusted (if necessary) to match the calibrator s output signal as closely as possible (see diagram). Procedure 1. Insert the microphone into the calibrator s microphone cavity as shown; ensure that it is fully inserted. Use the ½ microphone adaptor (supplied attached to the calibrator) for ½ microphones. Remove the adaptor (remove as shown in the Description section) for 1 microphones. 2. On the 407744, slide the function switch to the I (Power On) position. As soon as the unit is powered, the calibration tone is generated. On the 407766, slide the function switch to the 94dB or the 114dB position as desired. The calibrator generates its signal as soon as the switch is set. 3. Read the sound level meter s display. The sound level meter should read 94dB or 114dB depending on the calibrator s setting. If the sound level meter does not match the calibrator s signal (within specification), adjust it as explained in the Operation section (typically a front or sidepanel pot adjustment). Refer to diagram at right. 4. Slide function switch to the OFF position, and remove the microphone. Battery Check On the 407744, check the condition of the battery by moving the function switch to the Battery test position. The Battery status LED should illuminate if the battery is OK. If it does not light, replace the 9V battery. On the 407766, the POWER-ON / LOW-BATTERY LED glows brightly when the battery is fresh and dimly when the battery is weak. Battery Replacement Lift off battery compartment cap (shown in the Description section) to access the two (2) 9V batteries. Remove the batteries and replace with new alkaline 9V batteries. Replace the cap. 4 407744 & 407766 - V5.1 04/10

Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a six month limited warranty applies to sensors and cables). If it should become necessary to return the instrument for service during or beyond the warranty period, contact the Customer Service Department at (781) 890-7440 ext. 210 for authorization or visit our website www.extech.com for contact information. A Return Authorization (RA) number must be issued before any product is returned to Extech. The sender is responsible for shipping charges, freight, insurance and proper packaging to prevent damage in transit. This warranty does not apply to defects resulting from action of the user such as misuse, improper wiring, operation outside of specification, improper maintenance or repair, or unauthorized modification. Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct, indirect, incidental or consequential damages. Extech's total liability is limited to repair or replacement of the product. The warranty set forth above is inclusive and no other warranty, whether written or oral, is expressed or implied. Calibration and Repair Services Extech offers repair and calibration services for the products we sell. Extech also provides NIST certification for most products. Call the Customer Service Department for information on calibration services available for this product. Extech recommends that annual calibrations be performed to verify meter performance and accuracy. Support line (781) 890-7440 Technical Support: Extension 200; E-mail: support@extech.com Repair & Returns: Extension 210; E-mail: repair@extech.com Product specifications subject to change without notice For the latest version of this User Guide, Software updates, and other up-to-the-minute product information, visit our website: www.extech.com Extech Instruments Corporation, 285 Bear Hill Road, Waltham, MA 02451 ISO9001 Certified Copyright 2010 Extech Instruments Corporation (a FLIR company) All rights reserved including the right of reproduction in whole or in part in any form. 5 407744 & 407766 - V5.1 04/10