Hygro-/Thermometer. Operating Manual GFTH 95

Similar documents
Digital Quick-Response Thermometer

GMH Operating Manual for Digital Quick-Response Thermometer

Manometer. (Over- /Under- And Difference Pressure) Operating Manual GDH

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26 phone: / , fax: / ,

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26 phone: / , fax: / ,

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

Digital Precision Hand-held Measuring Device

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 100. T-Logg 100 E

Precision thermometer

Hand-held measuring device with alarm function

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 120 W -... T-Logg 120 K -...

Operating Manual Digital Quick Response Thermometer GMH 3210 For Thermocouple Probes Type J, K, N, S, T from Version 1.0

GMH to 1300 mbar absolute Version 4.7

Digital Precision Hand-held Measuring Device

Universal interface adapter for GMSD / GMxD - sensor

GHM Messtechnik GmbH Standort Greisinger Hans-Sachs-Str. 26 D Regenstauf +49 (0) 9402 / (0) 9402 /

Operating manual. GTL - Configuration tool. Please keep the manual for future use.

Operating manual GTL 142 GTL 152. Temperature probe. Please keep the manual for future use.

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

Precision thermometer

Operating instructions. Standstill monitor A / / 2011

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

Operating Manual Configuration software for EASYBus devices

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

GB/UK. Operating manual. Data logger EBI USB

Compact universal controllers

Classic Flanger effects pedal. user manual

TETRIS 2500 High Impedance Active Probe. Instruction Manual

Electronic Temperature Controller. Instruction Manual Version

Kvaser USBcan Light User s Guide

Operating Instructions for Hand-held Conductivity Measuring Units. Model: HND-C110

Temperature & Humidity Datalogger

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

Englisch. Operating Manual. Operating Software GHMware Retain for further references. Unternehmen / Marken der GHM

D1210H dimmer pack. user manual

D610H, D610H MKII, D610S, D610T dimmer pack. user manual

Manual. Polaron SMPS Watt power supply for chargers. No. S2024. Copyright Graupner/SJ GmbH

Operating and mounting instructions

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

English. Instruction and operation manual S 505. Dew point meter (portable)

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

Mini Digital Multimeter Model MN15. User's Guide

TA400 OPERATING MANUAL DYNAMIC PRESSURE ANEMOMETER TRT-BA-TA400-TC-002-EN

Operating instructions. Switching amplifier DN0210 DN / / 2015

MU110-6U. Analog output module 6 channel. User guide

Polymer Electric. Operating Instructions. Control Unit SG-RST 153. Version 0.3

BI20 OPERATING MANUAL LOCATING DEVICE TRT-BA-BI20-TC-002-EN

Operating instructions. Speed monitor D / / 2014

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

Pressure Transmitter and Reader of the PT-RF Series Manual

Next Generation! We measure it. With the professional Testo data loggers, a new age begins for you. Logger series testo 174. Logger series testo 175

DIS-2/M UTP DIS-2/M NSU DIS-2/M Multi-D HD

Operating Instructions

Operating Instructions Differential Pressure Transducer PS27

DIGITAL SOUND 8922 Owner s manual Sound level meter

User's Guide. MiniTec TM Series Model MN25 MultiMeter

testo 175 Data loggers Instruction manual

Operating manual. Diagnostic adapter VAS Operating manual Diagnostic adapter VAS Client documentation Revision: 00 Version: 05/2018

Smart Grid Tie Microinverter User Manual

374 FC/375 FC/376 FC. Clamp Meter. Safety Information

testo 184 Data logger Instruction manual

Kvaser Leaf Light v2 User s Guide

Kvaser Mini PCI Express User s Guide

Operating instructions for AX5801. TwinSAFE drive option card for the AX5000 servo drive. Version: Date:

GIR 230 TC Version 1.1

Instruction book IQAN-LSL. Publ no HY /UK Edition 0301

English. Operating manual. Limit switch GS125. Keep for future reference. Ventures / brands of GHM

DDC-6, DDC-12 LCD DMX controller. user manual

Kvaser Leaf Light v2 User s Guide

D-SEED effects pedal. user manual

Kvaser Mini PCI Express User s Guide

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

Operating Instructions

MDM 011-Z1 Regen Resistor

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

Colorado Series. CR-10 Portable ph / mv / Temperature Meter Operation Manual

UP-1-1 Channel Dimmer dimmer pack. user manual

Operating Instructions PRO-AB /6.15. Leakage Current Measuring Adapter

Next Generation! We measure it. With the professional Testo data loggers, a new age begins for you. Logger series testo 174. Logger series testo 175

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

EC Series. Safety Guide

PTZ Control VMC Joystick

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

RТTH DUAL ROOM SWITCH

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

User s Manual Model PBL100 Logic Probe IM E. 4th Edition

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Instruction book IQAN-LST. Publ no HY /UK Edition 0301

Mini Digital Multimeter

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

Kvaser PCIEcan HS v2 User s Guide

Hand-Held Thermometer Model CTH 6200

DPX-620III 6-Ch. dimmer pack. user manual

Kvaser Leaf Light v2 User s Guide

User Manual Shutter (T6801) and filter wheel (L981054) D / Sa

Transcription:

H53.0.X1.6C-07 Hygro-/Thermometer Operating Manual GFTH 95 WEEE-Reg.-No. DE93889386 GHM Messtechnik GmbH Standort Greisinger Hans-Sachs-Str. 26 D-93128 Regenstauf +49 (0) 9402 / 9383-0 +49 (0) 9402 / 9383-33 info@greisinger.de

H53.0.X1.6C-07 Operating Manual GFTH 95 Page 2 of 6 Contents 1 GENERAL NOTE... 3 2 SAFETY... 3 2.1 INTENDED USE... 3 2.2 SAFETY SIGNS AND SYMBOLS... 3 2.3 SAFETY GUIDELINES... 3 3 PRODUCT SPECIFICATION... 4 3.1 SCOPE OF SUPPLY... 4 3.2 OPERATION AND MAINTENANCE ADVICE... 4 4 NOTES FOR DEVICE FUNCTIONS... 5 4.1 CHOICE OF MEASURING UNIT... 5 5 SYSTEM MESSAGES... 5 6 SPECIFICATION... 5 7 RESHIPMENT AND DISPOSAL... 6 7.1 RESHIPMENT... 6 7.2 DISPOSAL INSTRUCTIONS... 6

H53.0.X1.6C-07 Operating Manual GFTH 95 Page 3 of 6 1 General Note Read this document carefully and get used to the operation of the device before you use it. Keep this document within easy reach near the device for consulting in case of doubt. The manufacturer is not liable for misprints. 2 Safety 2.1 Intended Use The safety requirements (see below) have to be observed. The device must be used only according to its intended purpose and under suitable conditions. Use the device carefully and according to its technical data (do not throw it, strike it,...) Protect device from dirt. Quick-response measurement of atmospheric humidity, temperature in EDP rooms, museums, churches, administrative and residential buildings, storage rooms, green houses, pools, production rooms, for cooling technology and air conditioning as well as for building engineers and for the evaluation of damage to buildings etc. 2.2 Safety signs and symbols Warnings are labelled in this document with the followings signs: DANGER Caution! This symbol warns of imminent danger, death, serious injuries and significant damage to property at non-observance. Attention! This symbol warns of possible dangers or dangerous situations which can provoke damage to the device or environment at nonobservance. Note! This symbol point out processes which can indirectly influence operation or provoke unforeseen reactions at non-observance. 2.3 Safety guidelines This device has been designed and tested in accordance with the safety regulations for electronic devices. However, its trouble-free operation and reliability cannot be guaranteed unless the standard safety measures and special safety advises given in this manual will be adhered to when using the device. 1. Trouble-free operation and reliability of the device can only be guaranteed if the device is not subjected to any other climatic conditions than those stated under "Specification". If the device is transported from a cold to a warm environment condensation may cause in a failure of the function. In such a case make sure the device temperature has adjusted to the ambient temperature before trying a new start-up.

H53.0.X1.6C-07 Operating Manual GFTH 95 Page 4 of 6 2. If there is a risk whatsoever involved in running it, the device has to be switched off immediately and to be marked accordingly to avoid re-starting. Operator safety may be a risk if: _DANGER - there is visible damage to the device - the device is not working as specified - the device has been stored under unsuitable conditions for a longer time. In case of doubt, please return device to manufacturer for repair or maintenance. 3. Do not use these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury or material damage. Failure to comply with these instructions could result in death or serious injury and material damage. _DANGER 3 Product Specification 3.1 Scope of supply The scope of supply includes: Device GFTH 95, incl. 9V battery block Operation manual 3.2 Operation and maintenance advice Battery operation: If BAT appears in the left hand corner of the display, the battery is used up and needs to be replaced. However, the instrument can still be operated for a short period of time. If bat is displayed in large letters the battery is finally used up and has to be replaced. Measuring is no more possible. The battery has to be taken out, when storing device above 50 C. We recommend taking out battery if device is not used for a longer period of time. The humidity and temperature sensor are located in the protruding sensor head. Make sure that the openings are not soiled. In case of soiling do not try to remove the dirt. Improper use may damage the sensors. Prevent any mechanical impact on the device as this may also lead to a destruction of the sensors (supporting material glass or ceramics)! In the sensor area there is ESD-sensitive. Never touch or hold sensor head! In order to guarantee accurate measurements the device has to be adjusted to ambient temperature. If necessary wait for the temperature of the device to adjust to the ambient temperature. If this is not possible, please proceed as follows: Move device around while holding it at an arm's length (fanning), to speed up the exchange of air and the temperature adjustment process. As soon as the display value is steady, readings can be made. This procedure shall be used for temperature and for humidity measurements. If you hold the device during measurements your body heat as well as your breath will change the temperature and the humidity. In order to minimise these factors, hold the device at as great a distance from the sensor as possible. Also try to prevent your breath coming into contact with the sensor. For optimum measuring results put down device and read display from a certain distance as soon as a constant measuring value is displayed. Always take into account that any humidity measurements in an open space cannot be made to an accuracy of more than 0.1% due to factors such as movement in the air, temperature changes etc. A user-calibration at the users site is not possible. To ensure highest accuracies it should be returned to the manufacturer every 12 months (when used in clean air) for checking or, if necessary: recalibration. If desired a calibration certificate can be made (acc. ISO 9000 ff). Price upon request. Probe tube and case are not 100% proof. If there are pressure differences between probe tube and case, there may be made wrong measuring. For measuring in channels with over/under pressure or strong air flow we recommend our GMH3330 or GMH3350 with humidity probe TFS0100 or TFS0100E.

H53.0.X1.6C-07 Operating Manual GFTH 95 Page 5 of 6 4 Notes for Device Functions 4.1 Choice of Measuring Unit The measuring unit can be chosen by means of the slide switch at the right side of the instrument. Temp slide switch up: The instrument shows the current temperature % RH slide switch down: The instrument shows the current humidity 5 System Messages In case of measuring range overruns, etc. according error messages are displayed: Er. 1 = measuring range has been exceeded Er. 2 = meas. values have fallen below perm. range Er. 7 = System fault - the device has detected a system fault 6 Specification Measuring range: temperature: -20,0 C... +70.0 C humidity: 10.0... 95.0 %RH (recommended range for application: 30 to 80 %RH) Resolution: temperature: 0,1 C humidity: 0,1 %RH Accuracy: (±1 digit) temperature: ± 0.5 % of m. v. ± 0.1 C (same as Pt1000 1/3 DIN) (at nominal temperature = 25 C) humidity: ± 3 % RH (range: 30... 80 %RH) Measuring probe: temperature: Pt1000 humidity: capacitive polymer humidity sensor Response time: T90 = 15 sec. Display: approx. 13 mm high, 3½-digit LCD-display Operation elements: Slide switch for selection of measuring range Nominal temperature: 25 C Operating conditions: electronics: -20... 70 C; 0... 80 % RH (non-condensing) sensors: -20... 70 C; 0... 100 %RH. Power supply: 9V battery (in scope of supply) Power consumption: approx. 0.1mA Low battery warning: "BAT" automatically displayed if battery is low Housing: impact resistant ABS-housing: approx.106 x 67 x 30 mm (HxWxD), in addition, sensor head protruding vertically, length 35 mm, diameter 14 mm, overall length 141 mm. Weight: approx. 135g incl. battery EMC: The device corresponds to the essential protection ratings established in the Regulations of the Council for the Approximation of Legislation for the member countries regarding electromagnetic compatibility (2004/108/EG). Additional fault: <1%

H53.0.X1.6C-07 Operating Manual GFTH 95 Page 6 of 6 7 Reshipment and Disposal 7.1 Reshipment _DANGER All devices returned to the manufacturer have to be free of any residual of measuring media and other hazardous substances. Measuring residuals at housing or sensor may be a risk for persons or environment Use an adequate transport package for reshipment, especially for fully functional devices. Please make sure that the device is protected in the package by enough packing materials. 7.2 Disposal instructions Batteries must not be disposed in the regular domestic waste but at the designated collecting points. The device must not be disposed in the unsorted municipal waste! Send the device directly to us (sufficiently stamped), if it should be disposed. We will dispose the device appropriate and environmentally sound.