Installation manual CF3-D, CF3-D-Disp

Similar documents
esense Duct (-Disp) Conduit

Please Read Instruction Carefully Before Installation! Figure 1: A/CO2-DUCT

asense m III in industrial wall mounted housing / CO sensor with built-in general purpose controller

Installation manual CF8-W-Disp-AL

AQS51/61-KAM COMBINED CO 2 -/TEMPERATURE DUCT SENSOR/CONTROLLER

The unit is designed for connecting to Direct Digital Control (DDC). The linear output functions are pre-programmed as CO 2

CDD4 Duct Carbon Dioxide Transmitter

2001VT Temp & CO 2. - air quality sensor/controller NOTE!!! Manual for Installation. General. SenseAir AB

RF-RR-C 24V Powered Routers CO 2 and RH & T Sensors

Installation Guide. Carbon Dioxide (CO 2. ) Detectors. General Information. Mounting WARNING CAUTION. SAE-1011/1012 Space Mount SAE-1011/1012/1062

TOXALERT MODEL AIR 2000

NSGV Series "90DM3" Carbon Dioxide Detector

Schneider Electric s SCD series of duct mount sensors measure the levels of CO 2. , RH (if equipped) and temperature of air inside a duct.

User Manual. PolyGard AT Infrared Carbon Dioxide transmitter Serial No. AT December, PolyGard is a registered trademark of MSR

Product Specification. CO 2 Engine ICB. Sensor module for bio applications

CDD Carbon Dioxide Transmitter

CDD4 Series Room CO2 Transmitter Installation Instructions

Gas and Air Sensors. Product Specification. CO 2 Engine K30. Sensor Module and OEM Platform. Document PSP 110. Rev 4. Page 1 (11)

Product Specification. CO 2 Engine K30 STA. Sensor Module and OEM Platform

Product Specification. Sensor Module and OEM Platform

Installation Guide. Section 1 - Room... pg 03. Section 2 - Duct... pg 23. I-CDD3_Modbus Installation. Modbus Gas Transmitters I-CDD3 Series

Table of Contents. General Information. Document Sure-Aire Flow Monitoring System. User and Service Manual WARNING CAUTION

Datasheet: K-33 BLG Sensor

InBin-P Pressure switches from 5 Pa Pa

Carbon Monoxide Sensor - ModBus

Carbon Monoxide Transmitter

IN-LINE. vpinstruments.com

Application. Types Available. Duct sensor for air quality, temperature and humidity (optional) Datasheet

Installing a Power over Ethernet injector

lindab we simplify construction UltraLink Technical information

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

C7110C1001A / C7110D1009A WALL MODULES

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

VFC. Operating manual TROX air terminal units Type VFC volume flow controllers. General information 2. VFC series volume flow controllers

Output signal active note. Output signal. temperature DC V, DC V DC V, DC V DC V

Zone Pressure Touch (ZPT) Sensor - Standard Range

Product Specification. CO 2 Engine K33-LP T. Sensor Module and OEM Platform. Document PSP0120. Rev 4. Page 1 (13)

CODE 50108, 50110, 50164, 50165

Greentrol Automation, Inc.

USER GUIDE PEL / PEL-M

CDD ModBus Carbon Dioxide Detector

Zone Pressure Touch Sensor - Standard Range

tsense (Disp) T RH RL

DST550 Digi-Stem Thermometer

Your Global Flow Control Partner. Series 50 Valve Status Monitor Operation and Maintenance Manual

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

Air Quality Solutions

ELECTROSTSTIC FIELDMETER

DIMENSION/WEIGHT kpa. 0 to 20 m / 0 to 60 ft 0 to 2 bar / 0 to 29 psi. 0 to 50 m / 0 to 160 ft 0 to 5 bar / 0 to 72.5 psi

BTU-4D/BTU-4D-I Digital Temperature Unit & Sensors. Installation and Operation Manual

BTU 4 & Sensors. Installation and Operation Manual

Zone Pressure Touch (ZPT) Sensor with Attached Tube (-AT) - Low Pressure Range Unit Installation and Operation Instructions

Operating Instructions for Digital Thermometers. Model: DTM

USER GUIDE PEL 8K / PEL 8K-M

MAXIMA+ Series Rotary Level Indicator

InReg Volume flow controller Pa

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

USER GUIDE TEHR LU / TEHR-M

CombiTemp TFRN/TFRH. Operating instructions. Temperature sensor. Operating Instructions: EN.

Installation and Assembly: 2 x 2 Video Wall Ceiling Mount for 40" - 55" flat Panel Displays

MAXIMA + Series ROTARY LEVEL CONTROL

Temperature sensors TTM series. Miniature transmitters

MAXIMA + Series ROTARY LEVEL CONTROL

ST-601 Inline ClO2 Concentration Monitoring Probe Instruction Manual

Model CD-AW. Infrared Environmental CO2 Sensor. Operator's manual

DIN Molded Cable Assemblies

V E62B Snap-in I/O Module

Instruction Manual. T3110 T3110L T3110Ex

Data Sheet for Joysticks

AWP-24-3 Wave Height Gauge User's Guide

Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24

DSI-4. DMX Optically Isolated 1x4 Splitter. D Series. DSI_4 Users Manual r3.lwp copyright 2009, 2010, 2011 ELM V. T. Inc.

Quick Start Guide. SEB-710 I/O Expansion board. Introduction

This guide provides basic information for Unitronics Models V230/260/280/290 (Non-color Screens).

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5

Humidity transmitter for critical climate applications

Mounting DIGITAL DISPLAY

V E5B Snap-in I/O Module

Temperature and humidity regulator H3020 H3021 H3023 H3027. Instruction Manual

Wafer Type Butterfly Valve

Flowtronic D 607 Series

BA/BS4S Temperature Sensor Installation & Operating Instructions

EL7060 Series SERVICE MANUAL

Distribution Systems for Sensors and Actuators

Environmental Equipment, Inc.

Basic Characteristics Data

Series A19A/A19B/A19D. Thermostats for Refrigeration, Cooling, Heating, Ventilation and Air-conditioning. Feature and Benefits

Inductive Cylinder Position Sensors

Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems

This guide provides basic information for Unitronics Models V230/260/280/290 (Non-color Screens).

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

ZC-OH5 TAMPER-RESISTANT INDOOR/OUTDOOR HOUSING INSTRUCTION MANUAL FOR USE WITH GANZ ZC-D5000 SERIES MINIDOME CAMERAS

TPE 1464 Series Pressure Transducer

) Forward voltage (V f. Typ. Typ. Typ. Max. Typ. Typ. Typ. [K] [lm] [lm] [V] [V] [lm/w] [lm/w] Operating Tc. current Temp

This guide provides basic information for Unitronics Models V230/260/280/290 (Non-color Screens).

TRANSMISSOR DE PRESSÃO PIEZO RESISTIVO INTELIGENTE MICRO PROGRAMÁVEL SÉRIE PAS

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

Pipe fittings and flanges, sockets for bayonet locks

Operation Manual SuperDry Data Logger (SDDL)

EVOLVE1-M MONITOR ARM

Transcription:

Installation manual CF3-D, CF3-D-Disp General Figure 1 The sensor The IAQ-sensor product CF3-D (for mounting in ventilation ducts) is designed to measure carbon dioxide (CO ). Option - TR is prepared for temperature measurements by the resistive temperature probe mounted by the user. Option -Disp displays the measured CO value in ppm (parts-per-million) on the LCD. The units are designed for connecting to Direct Digital Control (DDC) with 0-10V or -10V signal inputs. The two parallel signal outputs Out(1) (0-10V) and Out() (-10V or 4-0 ma) give linear signal voltages or currents corresponding to the measuring range. The output OUT() also indicates the status by setting the output voltage to 1V or the output current to ma when the sensor self-diagnostics detects any error. IMA 04 1 (7)

1 1 3 7 4 5 6 9 10 8 Figure Parts of the CF3-D for duct mounting 1 Sampling probe 6 O-ring 9,x3,53 (Factory mounted in box) Sealing gasket 7 PCB (Factory supplied mounted in box) 3 Largest locking nob 8 Snap-in lid 4 washers 9 PG9 cable entry bushing 5 screws IMA 04 (7)

Mounting of CF3-D on to the duct. 10 Figure 3 Mounting of the sensor to the ventilation duct 10 Hole with 5 mm diameter 11 Temperature sensor with 110 mm cable mounted in the sampling probe Mounting Instruction Since there might be a substantial pressure difference in duct mounting applications, it is essential to avoid ambient air from suction into the duct mounting box. For correct function it is indispensable that the sealing of the box cover, the cable entry bushings, the cable feed through and the duct entrance are absolutely tight. The duct entrance may need extra sealing paste in order to prevent leakage. The PCB must be handed carefully and protected from electrostatic discharge. 1) Electrical cable entry: The box has a factory mounted cable entry bushing in dimension PG9. Never feed more than one cable through each cable entry bushing, or else gas might leak through! ) Mounting the tube: Drill a hole (10) with 5 mm diameter (or 1 inch) for the sampling probe and two holes with 4 mm diameter for the screws (5) into the air duct and mount the tube (1) with the gasket (). The sampling probe should be mounted with the largest locking knob on top. The unit can be mounted with the air coming from the left or right. 3) Attaching the sensor box is made to the sampling probe by a snap-in bayonet fitting. Orient the box onto the sampling probe so that the box upside is on the same side as the largest locking knob (3). When the probe is fitted into the notches of the box, then turn the box clockwise until stop (see Figure 1). Position 1 indicates open where the box can be removed from the sampling probe. In position the box is locked to the probe. IMA 04 3 (7)

Electrical connections The power supply has to be connected to and. is considered as system ground. The same ground reference has to be used for the CF3-D unit and for the DDC/signal receiver. PLEASE NOTE! The same ground reference has to be used for the CF3-D unit and for the control system! Terminal Function Electrical data Remarks Standard settings Power () 4 VAC/DC (- 0%), W Remarks Settings of this sensor Out(1) Power ground (-) Analogue output 1 () 4 VAC/DC- System voltage reference 0-10 VDC 0-000 ppm CO Out() Analogue output (),0 10,0 VDC or 4,0 0,0 ma 0-000 ppm CO 0,9 1,6 VDC or 1.5 to,5 ma Status = ERROR 0 VDC or 0mA Status = NOT READY Table I. Connections of the main terminal of CF3-D IMA 04 4 (7)

Option display Figure 4 PCB with jumper to configure OUT for current output 4-0mA or voltage output -10VDC Figure 5 Enlarged picture of the PCB with the jumper set to current output (left position) Figure 6 Enlarged picture of the PCB with the jumper set to voltage output (right position) Self-diagnostics The system contains a complete self-diagnostic procedure that is executed automatically when the sensor is in operation. Sensors with display show a wrench if an error is found. The wrench is shown during the first seconds after power up and if the measuring range is exceeded. The output Out() indicates the same information by setting the output voltage to 1V or ma. IMA 04 5 (7)

Maintenance The CF3-D is basically maintenance free in normal environments thanks to the builtin self-correcting ABC algorithm. PLEASE NOTE! The sensor accuracy is defined at continuous operation (at least 3 weeks after installation) PLEASE NOTE! Electronic products should be disposed of via a suitable recycling centre. IMA 04 6 (7)

Dimensions Figure 7 The dimensions of the sensor in mm and (inches) IMA 04 7 (7)