TB 45 Temperature limiter / monitor

Similar documents
Limit signalling function for any type of input signal... DESCRIPTION

Preset for output value APPLICATIONS

APPLICATIONS. Furnaces and ovens Burners and boilers Weighing and batching Process control Plastics processing... DESCRIPTION

APPLICATIONS. Container scales Floor scales / platform scales Road vehicle weighbridges Rail vehicle weighbridges Crane weighers Transshipment cranes

Controller. Application Example Climate chambers, dryer, heat threating plants, sterilisers, packing machines, food application, laboratory

KS 40-1 / 41-1/ 42-1 Universal Industrial Controller

KS 3012 PMA GENERAL DESCRIPTION

APPLICATION. Data acquisition Remote I/O I/O extension DESCRIPTION CONSTRUCTION

KS 90-1 Industrial and Process Controller

KS 90-1 Industrial and Process Controller

KS 108 easy Compact automation unit for industrial control and process technology

KS 108 easy Compact automation unit for industrial control and process technology

West Instruments. The 8800 series. Process Controllers and Profilers series. ...setting a new standard in advanced control

JUMO safetym TB/TW 08 Temperature limiter, monitor as per DIN EN

v v PMA isolated by means of opto-couplers.

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

Compact universal controllers

PMA Prozeß- und Maschinen-Automation GmbH. Temperature monitor TB 40-1 TB40-1 TB40-1. Operating manual English

KS 90-1 / 92-1 Industrial and Process Controller

JUMO Quantum PID100/PID200/PID300

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

itemp TMT180 Technical information

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

Controller module. Brief description. Features. Block structure. Page 1/7. Data Sheet

Safety Temperature Limiter TT-STL 50

JUMO diraview 104/108/116/132

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

iologik 4000 Series (M) Modules

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

TM3TM3 module TM3-2 temperature inputs and 1 analog output

MID approval no. DE-08-MI004-PTB004 Date of release

TM3TI4 module TM3-4 inputs temperature

AMC 8 & IOC 8T. Analog Monitoring Card Type AMC 8 and Input / Output Card Type IOC 8T FEATURES

Multifunction controller GHM-ONE MSR9696H. Multifunction controller. Features. ... professional Instruments M ADE IN GERMANY

FL MC 2000E (SM40) LC

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

Faults on the system Proximity switch connection technology:

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

Controller module. Brief description. Features. Block structure. Data Sheet Page 1/7

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

THM501 PT100 MODBUS TEMPERATURE TRANSMITTER

KS 108 flexible Compact PLC with touch operating screen

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

aditec CONTROLS for FOODTECHNOLOGY

DINALOG A 96 x 24. Programmable quasi-analogue bar graph meters. Technical characteristics DINALOG A 96 x 24

C160 Wall-/Pipe Mounted Universal Process Indicator

Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

Gas Controller System DGC-06

Wall-/Pipe Mounted Universal Process Indicator

Operating instructions. Standstill monitor A / / 2011

TM3TI4 module TM3-4 inputs temperature

CJ1W-PTS/PDC/PH41U/AD04U

Compact Universal Controllers

MINI-PS AC/10-15DC/8

Intrinsically Safe Barriers

DINALOG A 144 x 36 A1400 Light-Strip Indicator

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS

TU531, TU532 Terminal Unit

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

PMA Rail Line. Product Brochure.

Data sheet Video Recorder LINAX A303

MINI MCR-SL-PT100-UI(-SP)(-NC)

High-powered control system for sophisticated processes

TF501, TF521 Terminal Bases

AI531 Analog Input Module

DI572 Digital Input Module

Features and Benefits. Certifications

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

UNIVERSAL TEMPERATURE TRANSMITTER

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

Digital Overspeed Protection System with PROFIBUS -DP interface DOPS, DOPS AS, DOPS TS

DX561 Digital Input/Output Module

RSTI-EP Slice I/O. Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3664, EP-3704, EP GFK-2960F September 2018

DI561 Digital Input Module

General information. Display. Supply voltage

DC562, digital input/output module,

TM3AI4 module TM3-4 analog inputs

/8 DIN Universal Process Indicator

CSI 6300 SIS Overview

I/O module, analogue outputs and universal inputs

Power supply CP-C 24/5.0

Trident and Trident X2 Digital Process and Temperature Panel Meter

General information. Display. Supply voltage. Input current

SEM310 SEM310X HART UNIVERSAL TEMPERATURE TRANSMITTER

ATV320U07M2C variable speed drive ATV kW V - 1 phase - compact

AO523 Analog Input Module

Millenium 3. General Characteristics. General environment characteristics for CB, CD, XD, XR and XE product types

Millenium 3 logic controllers

General information. Display. Supply voltage. Input current

English. Operating manual. Limit switch GS125. Keep for future reference. Ventures / brands of GHM

Temperature-Guard TG 50 Pt100/Pt Thermocouple J, K, N, S

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage

Transcription:

TB 45 Temperature limiter / monitor Compact design Suitable for heating and refrigeration processes For all thermocouple types and resistive sensors Display & operating functions Communication functions Two relay outputs Analog output Two universal inputs Reset via front key combination / external contact Type-tested to DIN 344 / EN 4597 rail line FEATURES Configurable as limiter, monitor, or limit signaller Compact design, only.5 mm wide Clips onto top-hat DIN rail Plug-in screw terminals or spring-clamp connectors Dual-line LC display with additional display elements Convenient 3-key operation Communication via bus connector fitted in top-hat rail BluePort front interface Two universal inputs Two relay outputs Two pre-alarms Universal output for display values APPLICATIONS All plants, in which an exceeded min/max temperature limit can cause serious damage. Heating system in buildings to DIN EN 88 Large hot-water boilers to DIN EN 953-6 Thermal transfer plants with organic heat transfer media to DIN 4754 Oil-fired installations to DIN 4755 Limit signalling function for any type of input signal... DESCRIPTION The temperature limiter TB 45 is intended for precise, cost-effective signal monitoring & limiting tasks. Every TB 45 is fitted with at least one universal input and two output relays. Optionally, the TB 45 can be supplied with an analog output for display purposes. Galvanic isolation is provided between inputs and outputs as well as from the supply voltage and the communication interfaces. Mounting The compact TB 45 is clipped onto a top-hat DIN rail, and can also be unmounted very simply. All connections are of the plug-in type, so that a device can be replaced very quickly without disturbing the wiring. Display and operation The dual-line LC display permits simultaneous indication of the measured value and all of the unit s operating functions. Moreover, a LED and 4 other display elements give a reliable indication of operating status, operating mode, and error messages. The user-configurable engineering unit of the measured value can be included in the display. By means of the extended Operating Level, it is possible to show any signal or parameter in the nd display line. Interfaces and Engineering Tools The limiter s settings are also configurable by means of an Engineering Tool. Via the BlueControl software (which includes a limiter simulation), and especially the convenient connection via the BluePort front interface, the user can solve the task in hand without having to work through operating instructions. Of course, practically all settings can also be made from the device front. Moreover, the TB 45 can exchange data with superordinate PLCs and PCs via an optional RS 485 interface with Modbus RTU protocol that is fitted into the top-hat DIN rail. Devices with option system interface can be connected to fieldbus coupler of the rail line series. Password protection Unauthorized access to the limit settings and the Operating Levels is prevented with a password.

TECHNICAL DATA INPUTS Survey of inputs Input INP INP (Option) di Purpose X (process value ), universal input X (process value ), universal input; input for additional limit monitoring and display Operation disabled; Reset of stored alarms UNIVERSAL INPUT INP Type: single-ended, except thermocouples Resolution: > 4 bits Decimal point: to 3 decimals Digital input filter: adjustable...999.9 s Scanning cycle: ms Linearization: 5 segments, adaptable with BlueControl Measurement value -point or offset correction: Thermocouples (Table ) Input resistance:? M[ Influence of source úv/[ resistance: Input circuit monitor break, reversed polarity Cold-junction compensation Internal - additional error: typical: ß_.5 K max.: ß +. K External... C Break monitoring Sensor current: úa Operating sense configurable Resistive sensors (Table ) Connection technique: 3-wire or 4-wire (not available if using INP) Lead resistance max. 3 [ (for max. span): Input circuit monitoring: break and short circuit Table : Thermocouple input Thermocouple type Measurement range Accuracy Typical resol. L Fe-CuNi (DIN) -... 9 C -48...,65 F ß K. K J Fe-CuNi -..., C -48...,9 F ß K. K K NiCr-Ni -...,35 C -48...,46 F ß K. K N Nicrosil/Nisil -...,3 C -48...,37 F ß K. K S PtRh-Pt %...,76 C 3... 3, F ß K. K R PtRh-Pt 3%...,76 C 3... 3, F ß K. K T** Cu-CuNi -... 4 C -38... 75 F ß K.5 K C W5%Re-W6%Re...,35 C 3... 4,99 F ß 3K.4 K D W3%Re-W5%Re...,35 C 3... 4,99 F ß 3K.4 K E NiCr-CuNi -..., C -48...,83 F ß K. K B* PtRh-Pt6% (4)...,8 C 3(75)... 3,38 F ß 3K.3 K Special -5 +75 mv ß.%.% * Values apply from 4 C upwards **Values apply from -8 C upwards Table : Resistive inputs Type Sensor current Measurement range Accuracy Typical resol. Pt *** -.. (5) C -38... (3) F ß K. K Pt -... 85 C -38...,56 F ß K. K Pt -... 85 C -38...,56 F ß K. K KTY -6* -5... 5 C -58... 3 F ß K. K Special...4,5 [** ß.%.%.5 ma Special...45 [** ß.%.% Potentiom....6 [** ß.%.% Potentiom....45 [** ß.%.% Poti...,6 [** ß.%.% Poti...4,5 [** ß.%.% * Default setting is the characteristic for KTY -6 (-5...5 C) ** Including lead resistance Table 3: Current and voltage input Measurement range Input resistance Accuracy Typical resol.... ma [ ß. %,5 µa... V k[ ß. %,6 mv -... V k[ ß. %, mv -5... 5 V k[ ß. %,6 mv -,5... 5 mv* > M[ ß. % 6 µv -5...,5 mv* > M[ ß. % 6 µv -5... 9 mv* > M[ ß. % 8 µv -5... 5 mv* > M[ ß. % 8 µv -... mv* > M[ ß. % 4 µv * For INP: high-impedance, without break monitoring for INP: high impedance, break monitoring always active Measurement span separated into ranges Physical measurement range:...4,5 [ The BlueControl software enables the internal characteristic curve for the KTY -6 temperature sensor to be adapted. Current and voltage measurement (Table 3) Span start and span: anywhere within the measurement range Scaling: freely selectable,999...9,999 Input circuit monitoring (current):.5% below span start ( ma) O - measuring (option) EMI-measuring by means of INP (high-impedance mv-inputs) suitable for probes with constant sensor temperature (heated probes), setting by means of parameter measured sensor temperature (non-heated probes), measuring by means of INP ADDITIONAL INPUT INP (UNIVERSAL, OPTIONAL) Resolution: Digital input filter: Scanning cycle: Linearization: Measurement value correction: Type: > 4 bits adjustable...999.9 s ms as for INP -point or offset single-ended except thermocouples TB 45

Thermocouples (Table ) Cold-junction compensation Internal - additional error: typical: ß_.5 K max.: ß -.5 K External... C Remaining technical data as for INP. Resistive sensors (Table ) Connection technique: 3-wire Measurement span Remaining technical data as for INP. Current and voltage measurement (Table 3) Remaining technical data as for INP except: Voltage input ranges...+v and -5...+5V not possible. Millivolt input ranges: break monitoring always active. CONTROL INPUT DI (RESET) Configurable as direct or inverse switch or push button! Contact input Connection of potential-free contact that is suitable for switching dry circuits. Switched voltage: 5 V Switched current: ma Optocoupler input Actively switched optocoupler input Nominal voltage: 4 V DC external Logic : -3 V +5 V Logic : 5 V 3 V Current demand: max. 6 ma OUTPUTS SURVEY OF OUTPUTS Output Purpose LC (relay) Limit contact, alarms * OUT (relay) Limit contact, alarms, errors * OUT3 (logic, Same as OUT option) OUT3 (continuous, option) Analog output (display value, Inp, Inp), Transmitter supply * All logic signals can be OR-linked. RELAY OUTPUTS LC, OUT Type: NO contacts with a common terminal Max. contact rating: Min. contact rating: Switching cycles (electrical): Note: 5 VA, 5 VAC, A at 48...6 Hz, resistive load 6V,mADC for I=A/A:? 8,/5, (at 5VAC, resistive load) If the relays OUT and OUT operate external contactors, these must be fitted with RC snubber circuits to manufacturer specifications to prevent excessive voltage peaks at switch-off. OUT3 AS UNIVERSAL OUTPUT (OPTION) Galvanically isolated from the inputs. Parallel current/voltage output with common minus terminal (combined use only in galvanically isolated circuits). Freely scalable Resolution: 4 bits Tracking error I/U: ß % Residual ripple: (referred to end of span) ß_%...3 khz Current output /4... ma, configurable short-circuit proof Control range: -.5...3 ma Load: ß 7 [ Load effect: ß.% Resolution: ß.5 úa Error: ß.% Voltage output /...V, configurable not continuously short-circuit proof Control range: -.5...5 V Load:? k[ Load effect: ß.6% Resolution: ß.75 mv Error: ß.% Additional error with ß.9% simultaneous use of current output OUT3 as transmitter supply Output: ma /? 3 V OUT3 as logic signal Load 7 [ /ß 3 ma Load > 5 [ /> 3 V GALVANIC ISOLATION (FIG. ) Galvanic isolation is provided between inputs and outputs as well as from the supply voltage (3-port-isolation). Test voltage: Between power supply and in-/outputs: Between input and output: Isolation: between in-/output against earth: Fig.: galvanic isolation System Power Relay LC RS 485 Relay OUT FUNCTIONS Safety isolation Function isolation LC RELAY OUTPUT.3 kv AC, min 5 V AC; min ß 33VAC Input INP Input INP Front interface di (contact) di (option optocoupler) Output OUT3 Interruption of the power supply if the upper or lower limit for the process value is exceeded. Possible operation as: Limiter Switch-off if a limit is exceeded Output is re-enabled when the process value is within limits again (incl. hysteresis), and the electronic latch has been released manually via the reset function. Monitor Switch-off if a limit is exceeded Output is re-enabled automatically when the process value is within limits again (incl. hysteresis). Limit signaller Limit signalling function (see below) Process value settings: INP, optional difference INP-INP, MAX/MIN (INP, INP), O measurement. TB 45 3

OTHER LIMIT SIGNALLING FUNCTIONS MAX, MIN or MAX+MIN monitoring with adjustable hysteresis additional alarms available. Monitored signals Process value (absolute) Difference to limit contact LC (relative) Input Input Functions Input circuit monitoring Input circuit monitoring with latching Several limit and alarm signals can be OR-linked for output. ALARMS Sensor break/short circuit Depending on the selected input type, the input circuit is monitored for break, short circuit, and reversed polarity. Behaviour on sensor break / short circuit Response of the analog output is selectable (upscale / downscale) SIGNAL LINKING (OPTION) Additional combinations if INP is fitted: Difference INP - INP Max. value selection INP, INP Min- value selection INP, INP O measurement with constant sensor temperature (INP: mv input)* O measurement with measured sensor temperature (INP: mv input, INP: temperature input)* * Precise calculation using Nernst equation. DISPLAY AND OPERATION Display LCD dual-line plus additional display elements Upper line 4 digits, 7 segments for: Process value Limit value of LC Fig. : Connections TB 45 INP INP OUT3 PWR (mv) 5 6 L N ~9-6V ~4V Parameters Extended Operating Level 3 Additional display elements 4 display elements (bars in the lower line of the LCD) Identifiers &:LC/OUT active Identifier TB: Adjusted function as temperature limiter. Identifier E: Entry has been made in the error list. LED Dual-colour Green: OK Green, blinking: no data exchange with bus coupler (only for devices with system option) Red: limit value Lim/LC exceeded Red, blinking: internal fault Operating functions Only three keys at the front of the TB 45 are used to operate process values, parameters, and configuration data. Different Operating Levels and selected parameters can be disabled by means of BlueControl. 5 mv Logic 6 V 7 V 8 3 4 4 7 8 di RGND Data A Data B RS 485 LC OUT top RGND Data A Data B 5 6 7 8 System MAINTENANCE MANAGER Display of error messages, warnings, and stored limit value messages in the error list. Messages are stored, and can be reset manually. Possible elements in the error list: Sensor break, short circuit, incorrect polarity Stored limit values e.g. re-calibration warning (message is generated when a predefined operating time is reached) e.g. maintenance interval for a switching device (message is generated when a predefined number of switching cycles is reached) Internal fault (RAM, EEPROM,...) Lower line 5 digits, 4 segments; configurable contents (via BlueControl ) Engineering unit 4 TB 45

POWER SUPPLY Fig. 3: Dimensions Depending on ordered version: 5.5 (, ) AC supply Voltage: Frequency: Power consumption: 9...6 V AC 48...6 Hz approx. 7 VA max. 5 6 7 8 Klemme / terminal 3 4 Universal supply 4 V UC* AC voltage: 8...3 V AC Frequency: 48...6 Hz DC voltage: 8...3 V DC Power consumption: approx. 4 VA / 3W max. Supply only from protective low-voltage sources (SELV) * Devices with system option: They are supplied via the bus connector from bus coupler or power supply module. Behaviour with power failure Configuration and parameter settings: Permanent storage in EEPROM BLUEPORT FRONT INTERFACE Connection to the transmitter front via a PC adapter (see Accessories ). The BlueControl software enables the TB 45 to be configured, parameters set, and operated. BUS INTERFACE (OPTIONAL) RS 485 Connection via bus connector fitted in the top-hat rail. Screened cables should be used. Galvanically isolated Type: RS 485 Transmission speed:,4, 4,8, 9,6, 9,, 38,4 bits/s Parity: even, odd, none Address range:...47 Number of devices per 3 bus segment: PROTOCOL MODBUS RTU SYSTEM INTERFACE For connection to fieldbus couplers (see system components) Connection via bus connector fitted in the top-hat rail. Technical data see data sheet 9498-737-593. ENVIRONMENTAL CONDITIONS Protection classes Front panel: IP Housing: IP Terminals: IP Permissible temperatures For specified accuracy: Warm-up time: Temperature effect: Additional effect of CJ compensation: Operating limits: For storage: -...55 C ß minutes ß.5% / K ß.5% / K -...6 C -3...7 C Humidity Max. 95%, 75% yearly average, no condensation Shock and vibration Vibration test Fc (DIN EN 6 68--6) Frequency: Unit in operation: Unit not in operation:...5 Hz g or.75 mm g or.5 mm Shock test Ea (DIN EN 6 68--7) Shock: Duration:.5 (,87 ) 5g ms 7.5 (4,63 ) (4,37 ) 56 7 8 Electromagnetic compatibility Complies with EN 6 36- for continuous, unattended operation. Interference radiation: Within the limits for Class B devices. Immunity to interference: Meets the test requirements for devices in industrial areas. Evaluation criteria: Surge interference partly has marked effects, which decay after the interference stops. With high levels of surge interference on 4 VAC mains leads, it is possible that the device is reset. With HF interference, effects up to 5 µv can occur. GENERAL Klemme / terminal Housing front: Material Polyamid PA 6.6 Flammability class: V (UL 94) Connecting terminals: Material: Flammability class: 3 4 Electrical safety Complies with EN 6 -: Over-voltage category II Contamination degree Protection class II.3 (,8 ) 99 (3,9 ) Polyamid PA V (UL 94) for screw terminals V (UL 94) for spring-clamp terminals and bus connections TB 45 5

Electrical connections Plug-in connector strips with choice of terminal type: Screw terminals for lead cross-sections from. to.5 mm (AWG4-) Spring-clamp terminals for lead cross-sections from. to.5 mm (AWG4-) Mounting method Clip-on rail mounting (35 mm top-hat rail to EN 5 ). Locked by means of metal catch in housing base. Close-packed mounting possible. Mounting position: Weight:.8 kg vertical CERTIFICATIONS CE certification DIN 344 / EN 4597 UL / cul ACCESSORIES BlueControl (Engineering Tool) PC software package for configuring, parameter setting, and operating (commissioning) the TB 45. Moreover, all settings are saved and can be printed, if required. Table 4: BlueControl, Versions and functions: Functionality Mini Basic Expert parameter and configuration setting download: writes an engineering to the device online-mode / visualisation SIM only yes yes creation of user defined linearizations configuration of extended operation level upload: reads an engineering from the device SIM only yes yes basic diagnosis function no no yes saves files and engineering data no yes yes printer function no yes yes online documentation / help system measurement correction (calibration procedure) data acquisition and trend function SIM only yes yes personal assistant function Blocking operator functions, Operating Levels, and password definition Text inputs Definition of the display contents Hardware requirements: A special PC adapter (see Additional Accessories ) is required for connecting to the unit. Fig. 4: Hiding of interface parameters, only address visible Depending in version, a powerful data acquisition module with trend graphics is available. Show/hide functions The BlueControl software enables any number of parameters and configuration setting to be shown/hidden. Updates and demo software from: www.pma-online.de This ensures that only permitted parameters & settings can be changed in the unit. Safety-relevant parameters are not displayed. Simulation functions The built-in simulation serves to test the settings. Software requirements: Windows 95/98/NT//XP Configuration settings that can only be made via the BlueControl software (not via the unit s front keys): Customer-specific linearization Setting the limits for operating hours and switching cycles Switch-over to 6 Hz mains frequency 6 TB 45

Fig. 5: Accessory parts 4 3 5 ACCESSORIES Description Orderl-No. Connector set with screw terminals 4 pcs. 947-998-7 Connector set with spring-clamp terminals 4 pcs. 947-998-7 3 Bus connector for fitting in top-hat rail pcs. 947-998-7 4 Plug for bus connection, connections at left, pcs. 947-998-73 horizontal cable entry 5 Plug for bus connection, connections at right, vertical cable entry pcs. 947-998-74 ADDITIONAL ACCESSORIES Description Order-no. PC adapter for the BluePort front interface 947-998- USB serial adaptor (USB to RS 3) 947-998-8 Converter RS 3 to RS 4/485 galv. isolated ADAM-45-D BlueControl Mini www.pma-online.de BlueControl with Basic license rail line 947-999- BlueControl with Expert license rail line 947-999- TB 45 7

ORDERING INFORMATION SYSTEM COMPONENTS Temperature limiter TB 45 universal input, digital input with display and BluePort interface without plug-in connector terminals with screw terminal connector 9...6V AC, relays 8...3VAC/8...3VDC, relays 9...6V AC, ma/v/ logic + relays T B45 Fieldbus coupler PROFIBUS DP Fieldbus coupler PROFIBUS DP, UL / cul certified Power supply module Power supply module UL / cul certified RL4--- RL4---U RL4-9-- RL4-9--U 8...3VAC/8...3VDC, ma/v/ logic + relays 3 without options RS 485 / MODBUS - protocol System interface (only for 4V versions) di as contact input di as optocoupler input INP als universal input, -measurement, di as contact input INP als universal input, -measurement, di as optocoupler input 3 Standard configuration Customer-specific configuration 9 Standard (CE-certification) UL, cul U DIN 344 / EN 4597 D Standard accessories Operating notes Devices with Interface option: bus connector for fitting into top-hat rail Please also order the associated documentation (as separate item): DOCUMENTATION Description Order-no. Operating instructions TB 45 (E) 9499-4-79 Interface description for Modbus rail line (E) 9499-4-7 Interface description PROFIBUS-DP (E) 9499-4-77 Data sheet system components rail line (E) 9498-737-593 PMA Germany PMA Prozeß- und Maschinen-Automation GmbH Miramstraße 87, D-343 Kassel Tel.: +49 56 55-37 Fax: +49 56 55-66 E-mail: export@pma-online.de Internet: http://www.pma-online.de Your local distributor Printed in Germany - Edition /5 - Data subject to alteration without notice - 9498-737-4843