Wattstopper. Catalog Number: LP8 and LP24 INSTALLATION. Lighting Control Panel Quick Start Guide. No: /16 rev. 1

Similar documents
Installation Instructions

TS InteliSwitch Digital Time Switch 24VDC/VAC

Installation Instructions

Installation Instructions

CA-A480-A Elevator Controller. Reference & Installation Manual

Installation Instructions

INSTALLATION INSTRUCTIONS

AirTest Model CN9000 Series Sensor Controller

INSTALLATION INSTRUCTIONS

Overview These instructions are presented as a guideline for installing and setting up the LX Series Breaker Control Panel.

Installation Instructions

Installation Instructions

Installation Instructions

Install Motor Controller User Manual

Models 120LS, 200LS, 300LS, 400LS, 560LS Installation Instructions

PMDX-108-Output. 8-Channel Isolated Output Board for PC parallel port pins 2-9. User s Manual

Installation Instructions

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

ES-600 Ozone Controller Operation Manual

INSTALLATION INSTRUCTIONS

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Lighting Control Panel 16 and 24 INSTALLATION INSTRUCTIONS

OZONE SWITCH Model OS-6. OS-6 Features

INSTALLATION INSTRUCTIONS

Carefree-Security. Installation and programming instructions 1050A. Owner s Manual

Instruction Manual: IM E

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

PMDX-103. Parallel Port Isolator Board. User s Manual. Document Revision: 1.2 Date: 20 February 2007 PCB Revision: PCB-447B

Digital Lighting Systems, Inc. PD216. Two Channel Dimmer and Switch Packs PROTOCOL USER'S MANUAL. PD216-UM Rev. E - 02/03

Installation Instructions Model LFMWLT450, Class 1 Series AC-DC Power Supply

INSTALLATION INSTRUCTIONS STZ-R SERIES (ENGLISH)

CubePro. Main PCB Replacement Guide. Prosumer 3D Printer. Original Instructions

Model HM-535 Power Supply Installation and Service Instructions

Measure Ø-N, Ø-Ø, Ø-Gnd with voltmeter to confirm application voltage prior to installation.

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

Expandable Power Systems

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE

COBEX RECORDERS, INC.

A0/A1 Controller Assembly Operation/Installation Manual READ AND FOLLOW ALL SAFETY INSTRUCTIONS

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

AK-21. Digital Keyless Entry System. Installation and Programming Instructions

Model# CKM18 Model# CKM36 Model# CKM48 WARNING

Allen-Bradley PLCs. 100 Programmable Controller Processor Unit -Catalog Nos LPI01, -LP102, -LP103, -LP104 SLC TM. The Unit

Wiring Inside the card reader you will see a circuit board. The connections are as follows:

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

Connecting a Cisco Output Module

Specialized Lighting Solutions, Inc. SLS DALI CONTROLLERC

Rev. A. ANC Series RS-485/RS-422 Synchronous Clock Display. Antona Corporation (818) URL:

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT

IRB-MON O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY PHOTOEYE U L M O N I T O R E D DEVICE

CDD Carbon Dioxide Transmitter

Nevco Message Center Installation Manual Retain this manual in your permanent file. 08/27/ Rev. C

SERVICE MANUAL MODEL SSW-520-F

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION IMPORTANT SAFETY INSTRUCTIONS

EverPump Wireless Pump control system

VRp Three-Phase Precision AC Voltage Regulator

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

PQ V ac. CONTROL PANEL 230V FOR ROLLING SHUTTERS Instructions Manual. Control panel for electric rolling shutters 230Vac TECHNICAL FEATURES

COCKPIT DOOR SURVEILLANCE SYSTEM - DESCRIPTION AND OPERATION

641G-001A PRINTER KIT INSTRUCTIONS

MAXIMA + Series ROTARY LEVEL CONTROL

SECURE/NONSECURE LED SIGN USER MANUAL

Catalog Numbers Les Numéros de Catalogue Números de Catálogo: LMSM-3E/LMSM-6E INTRODUCTION

MAXIMA+ Series Rotary Level Indicator

Self-Adjusting Ultrasonic Wall Switch Sensor

ILC LightLEEDer MicroLite 1000P Retrofit Installation

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

Digital Keypad Introduction

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

Photoelectric Sensor

Expansion Unit Catalog Nos , - 152, - 153, - 154, - 156, -E157

RB24 Relay Box Installation Guide For use in low voltage motorized window and skylight systems

V-9941A ONE ZONE HANDSFREE TALKBACK CONTROL UNIT

LC3 LIGHTING CONTROLLER OPERATIONS & MAINTENANCE MANUAL 2013 Dec

Photoelectric Sensor

OPLC Installation Guide

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

Area of Rescue Command Unit Installation Instructions Model AOR-8 / Model AOR-16

MAXIMA + Series ROTARY LEVEL CONTROL

Plus-X 300. Installation and Operation Manual

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

CONTACTOR DRIVER BOARD. DS200CDBAG1A and DS200CDBAG1B

232iLM Keypad Installation & Programming Instructions

DMX SYSTEM INSTALLATION GUIDE

DTMF-4HC. DTMF decoder board with four high current relays. Copyright 2004 Intuitive Circuits, LLC

The identified danger could cause physical and property damage.

Series 803 LED Product Price Display

Resolver to Digital Expansion Board

LPG STM 94442A User s Manual

HP ProLiant MicroServer

Solid State Relays with Failure Detection Function

Series Amp Pad Mount Quick Connect Input and Output Power Panels

DESCRIPTION AND OPERATION

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved.

QCPort Cover Control Trouble Shooting Guide

Oracle <Insert Picture Here>

Transcription:

attstopper Lighting Control Panel Quick Start Guide No:2279 11/16 rev. 1 Catalog Number: LP8 and LP2 Country of Origin: Made in China INSTALLATION 1. Loosen the enclosure s front cover screws (about 1/ ). Do not remove the screws. Lift the cover and pull it toward you to remove it from the enclosure. 2. emove the panel interior and set it aside.. Mount the panel enclosure to the wall using appropriate hardware (not provided).. Note the entry areas for low and line voltage in the picture. Install conduit into the designated areas of the enclosure.. einstall the panel interior using the original hardware. 6. Connect the power supply (lower left corner) to the line voltage power source. Note the allowable voltages printed on the unit. 7. Note the entry areas for low and line voltage in the picture below. Install conduit into the designated areas of the enclosure. 8. einstall the panel interior using the original hardware. 9. Connect the power supply (lower left corner) to the line voltage power source. Note the allowable voltages printed on the unit.

PANEL INTEIO COMPONENTS AND CONNECTIONS elay Control elay Line and Push-buttons Load Connections EM-2A2 Photocell Connections Keypad and Display Door (open) Interior door latches (Two black plastic self-retained pop-fasteners) Pull to release. Press to latch. Power Supply Connections Accessory Power Connections elay Switch and Pilot Connections Optional Group Switching (GS) Card Ground Neutral Line Line Voltage iring Section Power supply 277V 11V NEUT GND 1 2 6 7 8 ELCOM 2V 2VAC HITE ELA PILOT 2VDC 2V 2VAC HITE ACC. POE 2 Clock Screen HELP A C D E F G H Group switch card ( GS Option) Group channel control push-buttons (8) elay status LEDs (8) elay control push-buttons (8) Observe correct voltage as marked on power supply. The exterior panel cover is hinged in the center - the low voltage side is latched for easy access; the line voltage side is screwed down for safety. Inside the panel, all low voltage terminals are below a hinged metal door on which the clock screen display and programming keypad are mounted.

GENEAL INSTALLATION INFOMATION ANING: TUN THE POE OFF AT THE CICUIT EAKE EFOE IING. All power must be turned off prior to wiring, installation or service. More than one disconnect may be required to de-energize power to the LP8. External circuit protection to the LP8 is required (for example, circuit breaker). Installation shall be in accordance with all applicable regulations, wiring practices, and codes. Care should be taken to separate high voltage power from low voltage (Class 2) control wiring. Do not energize wiring until the unit is fully assembled and connected circuits have been tested and found to be free of electrical shorts. C8 (motherboard) Status LEDs (7) Solid Green () linking lue (1) Solid Green (2) elay Driver (D) boards (2) Flashing lue (at DS6) Power Supply (PS) board Group Switch Card (optional) Flashing lue LEDs (2) = normal operation linking Amber LEDs (2) = trouble condition Power LEDs (2) Solid Green linking Amber on D board (at DS7) = trouble condition POE UP AND TEST 1. Power up the panel. 2. Complete the tests in the table.. Upon completing and passing all tests, power down the panel.. Install, connect, and test low voltage devices, contactors and loads to the panel per the instructions referenced in the esources section below.. Program the clock per your application requirements and record relay schedules and scenario information on the Programming ecord Sheet. ANING: IMPOPE INSTALLATION O CONNECTION OF THE LP8 MA ESULT IN SEIOUS PESONAL INJU AND/O DAMAGE TO THE LP8 AND OTHE DEVICES..

1 2 6 Test esponse esult Observe the lue Status LED on the C8 board Observe lue LED (at DS6) on D boards (and on GS card if installed) Observe the Green Status LEDs on the C8 board Observe the two green Power LEDs at DS1 & DS2 on the PS board Look for any lit Amber LEDs on the D (and GS if installed). elay Operation: Press each elay control push-button lue LED blinks at a regular tempo. lue LED off or lue LED flashes at regular intervals on both boards. lue LED off or All 6 Green Status LEDs are Any Green Status LED is off. oth green Power LEDs are Either Green Power LED is off. No Amber LEDs observed. An Amber LED is lit or blinking. ed LED for each relay lights and relay clicks. Press button again, relay clicks and ed LED goes off. ed LED doesn t light and/or relay doesn t click. hat next? If the panel continues to fail a test, call Technical Support. eset panel power. Check LED again. eset panel power. Check LED again. eset panel power. Check LEDs again. Turn off power to panel and check red and black wire connections to the J2 terminal block on the PS board. eset panel power. Check LEDs again. eset panel power. Check for Amber LEDs again. Ok to wire low voltage devices to relay card terminals. See esources list for wiring and accessory installation instructions. Make sure a jumper is installed on PS board between ELCOM and 2V terminals.

The following instructional tools are available: ESOUCES 1. iring loads and accessories: LP Series Installation & iring eference (included with the panel): Detailed LP8 wiring instructions for relays/contactors and loads, as well as low voltage controls wiring and Group Switch card smartwiring procedures. 2. Low voltage control device installation instructions: Provided in the box with optional products.. LP8 Programming: LP Series User Guide (included with the panel).. Instructions for individual clock screens: Press the HELP button on the panel s clock keypad.. Keeping records of circuit and relay schedules and programming selections: LP8 Programming ecord Sheet (included with the panel). 6. Technical support: Visit our website see the downloads page for new matierals, FAQ area, or call 800.879.88. 1 2 AISE HELP SELECT LOE On min. Sunset link off? No es Time Delay/Sweep Interval: min.

AANT INFOMATION attstopper warranties its products to be free of defects in materials and workmanship for a period of five () years. There are no obligations or liabilities on the part of attstopper for consequential damages arising out of, or in connection with, the use or performance of this product or other indirect damages with respect to loss of property, revenue or profit, or cost of removal, installation or reinstallation. No. 2279 11/16 rev. 1 Copyright 2016 Legrand All ights eserved. Copyright 2016 Tous droits réservés Legrand. Copyright 2016 Legrand Todos los derechos reservados. 800.879.88 www.legrand.us/wattstopper