HP LeftHand P4500 and P GbE to 10GbE migration instructions

Similar documents
HP LeftHand SAN Solutions

HP LeftHand P4000 Virtual SAN Appliance in an HP BladeSystem environment solution guide

HP StoreVirtual Storage Multi-Site Configuration Guide

HP P4000 SAN Solution User Guide

HP Insight Remote Support Advanced HP StorageWorks P4000 Storage System

HP StoreVirtual Storage Multi-Site Configuration Guide

HPE StoreVirtual OS v13.5 Release Notes

HP 3PAR OS MU1 Patch 11

HP StorageWorks. P4000 SAN Solution user guide

HP Accelerated iscsi for Multifunction Network Adapters User Guide

Guidelines for using Internet Information Server with HP StorageWorks Storage Mirroring

HPE D2600/D2700 Disk Enclosure I/O Module Firmware 0149 Release Notes

HP 3PAR OS MU3 Patch 17

P4000 VSA Installation and Configuration Guide

HP ALM Client MSI Generator

HP P4000 Remote Copy User Guide

HP Virtual Connect Enterprise Manager

HP 3PAR OS MU3 Patch 18 Release Notes

HPE 3PAR OS MU3 Patch 24 Release Notes

HPE Security ArcSight Connectors

HP UFT Connection Agent

HP StorageWorks Enterprise Virtual Array 4400 to 6400/8400 upgrade assessment

HP OpenView Storage Data Protector A.05.10

IDE Connector Customizer Readme

Designing high-availability solutions using HP Integrity Virtual Machines as HP Serviceguard packages

HP ALM. Software Version: patch 2. Business Views Microsoft Excel Add-in User Guide

HP Operations Orchestration Software

Replacing the Battery HP t5730 and t5735 Thin Clients

HPE 3PAR OS MU5 Patch 49 Release Notes

HP Storage Mirroring Application Manager 4.1 for Exchange white paper

HP VMware ESXi and vsphere 5.x and Updates Getting Started Guide

HP integrated Citrix XenServer 5.0 Release Notes

HP StorageWorks MSA/P2000 Family Disk Array Installation and Startup Service

Assessing performance in HP LeftHand SANs

HP Intelligent Management Center Branch Intelligent Management System (BIMS) User Guide

HPE VMware ESXi and vsphere 5.x, 6.x and Updates Getting Started Guide

HP StoreVirtual DSM for Microsoft MPIO Deployment Guide

HP Device Manager 4.6

HPE StoreVirtual 3200 Storage Release Notes

HPE StoreEver MSL6480 Tape Library Version 5.50 Firmware Release Notes

External Devices. User Guide

HPE 3PAR OS GA Patch 12

HPE ALM Client MSI Generator

HP BladeSystem c-class Virtual Connect Support Utility Version Release Notes

Configuring Security Mitigation Settings for Security Bulletin HPSBPI03569 Protecting Solution Installation Settings

HP ProLiant Agentless Management Pack (v 3.2) for Microsoft System Center User Guide

HPE RDX Utility Version 2.36 Release Notes

HP StorageWorks. EVA Virtualization Adapter administrator guide

HP Management Integration Framework 1.7

HP Fortify Scanning Plugin for Xcode

Implementing High Availability for SAP Business Objects CMS Repository and Audit Database

HPE ALM Excel Add-in. Microsoft Excel Add-in Guide. Software Version: Go to HELP CENTER ONLINE

HP BLc Intel 4X QDR InfiniBand Switch Release Notes. Firmware Version

HP IDOL Site Admin. Software Version: Installation Guide

ProLiant Cluster HA/F500 for Enterprise Virtual Array Introduction Software and Hardware Pre-Checks Gathering Information...

External Devices User Guide

HPE 3PAR OS MU3 Patch 18 Upgrade Instructions

HP AutoPass License Server

HPE 3PAR OS MU3 Patch 28 Release Notes

Modem and Networking compaq notebook series

HPE Automatic Number Plate Recognition Software Version: Automatic Number Plate Recognition Release Notes

HP MSA Family Installation and Startup Service

HP ProLiant Essentials RDMA for HP Multifunction Network Adapters User Guide

Achieve Patch Currency for Microsoft SQL Server Clustered Environments Using HP DMA

HP LeftHand P4000 Windows Solution Pack Release Notes

XP7 High Availability User Guide

HPE Moonshot ilo Chassis Management Firmware 1.52 Release Notes

HPE 3PAR OS MU3 Patch 23 Release Notes

HP P6300/P6500 EVA Fibre Channel Controller Replacement Instructions

HP 3PAR Host Explorer MU1 Software User Guide

Configuring the MSA1000 for Linux or NetWare Environments

External Devices User Guide

Release Notes: ProCurve Network Immunity Manager Version 1.0, Update 3

HP 3PAR OS MU2 Patch 11

HP EVA Cluster Extension Software Installation Guide

HPE BladeSystem c-class Virtual Connect Support Utility Version Release Notes

HP ProLiant DL580 Generation 2 and HP ProLiant ML570 Generation 2 Server Hot-Add Memory. July 2003 (Second Edition) Part Number

HP integrated Citrix XenServer Online Help

HPE 3PAR OS MU3 Patch 97 Upgrade Instructions

HP D6000 Disk Enclosure Direct Connect Cabling Guide

System information update for system board replacement events

HP Data Protector A Support for Windows Vista and Windows Server 2008 Clients Whitepaper

HP Enterprise Integration module for SAP applications

HP Business Availability Center

HP BladeSystem c-class Ethernet network adaptors

HP P6000 Cluster Extension Software Installation Guide

HP Service Test Management

Configuring RAID with HP Z Turbo Drives

Configuring the HP StorageWorks Modular Smart Array 1000 and 1500cs for external boot with Novell NetWare New Installations

HPE 3PAR OS MU2 Patch 36 Release Notes

HPE StoreVirtual OS Update Guide

HP OpenVMS Software-Based iscsi Initiator Technology Demonstration Kit Configuration and User s Guide

HP Network Node Manager i Software Step-by-Step Guide to Scheduling Reports using Network Performance Server

HPE ilo Federation User Guide for ilo 5

HPE ProLiant Gen9 Troubleshooting Guide

ProLiant CL380 Software User Guide. Fourth Edition (December 2000) Part Number Compaq Computer Corporation

Release Notes: ProCurve Identity Driven Manager Version 2.0, Update 2

HP Insight Control for Microsoft System Center Installation Guide

HP BladeSystem c-class Ethernet network adapters

IEther-00 (iether) B Ethernet Driver Release Notes

Transcription:

HP LeftHand P4500 and P4300 1GbE to 10GbE migration instructions Part number: AT022-96003 edition: August 2009

Legal and notice information Copyright 2009 Hewlett-Packard Development Company, L.P. Confidential computer software. Valid license from HP required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor's standard commercial license. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. WARRANTY STATEMENT: To obtain a copy of the warranty for this product, see the warranty information website: http://www.hp.com/go/storagewarranty Microsoft, Windows, Windows XP, and Windows NT are U.S. registered trademarks of Microsoft Corporation.

Contents About this guide... 5 1 Instructions for migrating bonded interfaces in a SAN/iQ cluster from 1GbE to 10GbE Ethernet... 7 Overview... 7 Bonding 10GbE interfaces... 7 Supported bonds with 10GbE... 7 Unsupported bonds with 10GbE... 7 Migrating an existing cluster to a 10GbE bonded configuration... 8 Recommended bond configuration... 8 Installation overview... 8 Installation prerequisites... 9 Prepare IP address worksheets... 10 Put the management group into maintenance mode... 10 Install the hardware and the software upgrade patch... 11 Configure the 10GbE ports for SAN/iQ communication using the CMC... 13 Configure the Active-Passive bond using eth2 and Motherboard:Port1 (RECOMMENDED)... 14 Creating the Active-Passive bond... 14 Verifying the bond... 14 Changing the VIP if required... 15 Preparing your host server to be 10GbE capable... 15 Configure the 10GbE and 10GbE ALB bond (using eth2 and eth3)... 15 Creating the ALB bond... 16 Verifying the bond... 17 Changing the VIP if required... 17 Preparing your host server to be 10GbE capable... 17 1GbE to 10GbE migration instructions 3

Tables 1 2 3 4 5 HP LeftHand P4300 and HP LeftHand P4500 - possible 1GbE and 10GbE Ethernet bonds... 8 Storage node network configuration pre-migration... 9 Storage node network configuration post-migration... 9 Pre-upgrade storage node information... 10 During upgrade, use this storage node information... 10 4

About this guide This guide provides information about migrating bonded interfaces in an existing cluster from 1GbE to 10GbE. 1GbE to 10GbE migration instructions 5

6 About this guide

1 Instructions for migrating bonded interfaces in a SAN/iQ cluster from 1GbE to 10GbE Ethernet Overview The 10GbE feature option adds 10GbE over CX4 cabling to the HP LeftHand P4300 and HP LeftHand P4500 platforms. This is an add-on feature to the standard 1GbE dual Ethernet adapters built into the system boards of the P4300 and P4500. After the 10GbE dual port Ethernet adapter is installed and configured, users see 4 Ethernet interfaces listed in the Centralized Management Console (CMC) TCP/IP Network tab window. These 4 interfaces can be bonded a number of ways for redundancy and failover. Bonding 10GbE interfaces After installing the 10GbE Ethernet upgrade, you have a choice of supported bond configurations. Note that not all the bond configurations which are supported by the HP LeftHand Storage Solution are supported with the 10GbE upgrade. We recommend using the Active-Passive bond configuration with the 10GbE interface as the active primary interface and the 1GbE interface as the passive failover interface. Supported bonds with 10GbE The HP LeftHand P4300 and HP LeftHand P4500 with the 10GbE feature installed and configured now supports these new bond types. Active-Passive bond with 1GbE NIC and 10GbE NIC Adaptive Load Balancing (ALB) bond with the two 10GbE Ethernet NICs Active-Passive bond with two 10GbE Ethernet NICs Link Aggregation Dynamic Mode (802.3ad) bond with two 10GbE Ethernet NICs Unsupported bonds with 10GbE The HP LeftHand P4300 and HP LeftHand P4500 with the 10GbE feature installed and configured do not support these bond types. ALB with 1GbE Ethernet NIC and 10GbE Ethernet NIC 802.3ad with 1GbE Ethernet NIC and 10GbE Ethernet NIC Bonding 3 ports or all 4 ports (two 1GbE Ethernet & two 10GbE Ethernet) 1GbE to 10GbE migration instructions 7

Bonding two bonds Table 1 HP LeftHand P4300 and HP LeftHand P4500 - possible 1GbE and 10GbE Ethernet bonds Motherboard:Port1 (1GbE) Motherboard:Port2 (1GbE) eth2 (10GbE) eth3 (10GbE) SAN/iQ interface Enabled eth2 Enabled Enabled eth2 Enabled Enabled eth3 ALB Bond ALB Bond Bond 802.3ad bond 802.3ad bond Bond Bond (Active) Bond (Passive) Bond Bond (Passive) Bond (Active) Bond Bond (Passive) Bond (Active) Bond Bond (Active) Bond (Active) Bond Bond (Active) Bond (Active) Bond Bond-1GbE Bond-1GbE Bond-10GbE Bond-10GbE Bond-10GbE Migrating an existing cluster to a 10GbE bonded configuration If you are upgrading to 10GbE HP LeftHand P4300s and HP LeftHand P4500s that have bonded NICs and are already in a cluster and providing storage volumes, you must follow certain steps to ensure an effective migration to the new hardware configuration. This migration guide covers the following 2 of these possible bonded configurations. Active-Passive Bond: configured with the 10GbE interface as the active primary interface and the 1GbE interface as the passive failover interface. Adaptive Load Balancing Bond: configured with 2 10GbE interfaces as an ALB bonded pair. Recommended bond configuration The Active-Passive bond provides the best combination of high availability and performance. The performance boost comes from using the 10GbE as the active primary interface and using the 1GbE interface as the passive failover interface ensures a robust failover configuration. Installation overview The example below shows how to migrate existing HP LeftHand P4300s and HP LeftHand P4500s configured with a 1GbE Adaptive Load Balancing (ALB) bond to a configuration with a 10GbE and 1GbE Active-Passive Ethernet bond. In this case, the 10GbE interface will be the Active Ethernet interface of the bond and the 1GbE interface will act as the failover interface for the bond. For this example the other 2 Ethernet interfaces in the storage nodes are not used by SAN/iQ and can be disabled. 8 Instructions for migrating bonded interfaces in a SAN/iQ cluster from 1GbE to 10GbE Ethernet

The example below utilizes planned downtime of the entire management group and results in none of the volumes needing to restripe data. However, all access and I/O to the volume(s) is disconnected during this upgrade period. A summary of the installation and migration steps follow: 1. Stop all I/O and disconnect all iscsi sessions to volumes. 2. Shut down management group and power off all storage nodes. 3. Install 10GbE Ethernet adapter and additional memory in each storage node. 4. Power on each storage node and install 10GbE SAN/iQ software Patch 10041. 5. Configure new IP address and bonds for 10GbE on each storage node, and change SAN/iQ communication IP address. 6. Change the cluster's VIP if required. 7. Reconnect iscsi sessions and start I/O. Installation prerequisites Check the following two items before starting the migration from 1GbE interface to 10GbE interface: Have compatible VIP addresses for 10GbE and 1GbE switches that are running the 10GbE 1GbE Active/Passive bond. SAN/iQ version 8.x requires each cluster to have a valid VIP address. A valid VIP address is one that is on the same subnet as the storage nodes. This VIP address must be valid after updating the storage nodes to the 10GbE - 1GbE Active/Passive bond failover network. If the 10GbE and 1GbE are on the same network, you may not need to change/update the cluster VIP. Ensure that all network settings (Flow Control, Frame Size (MTU)) for each NIC are consistent across the switch, the storage node and the client. The network settings must be configured the same on each interface before creating a bond. Table 2 shows a summary of the network interfaces and bonds listed on the CMC TCP/IP Network panels before installing and configuring the 10GbE adapter. Table 3 shows a summary list of those interfaces and bonds after installing and configuring the 10GbE adapter. NOTE: The SAN/iQ communication interface in both configurations is Bond0. Table 2 Storage node network configuration pre-migration NIC Motherboard:Port1 Motherboard:Port2 Bond type Speed 1GbE 1GbE 1GbE Mode Slave (bond0) Slave (bond0) Logical Failover Device (Adaptive Load Balancing - ALB) Table 3 Storage node network configuration post-migration NIC Motherboard:Port1 Motherboard:Port2 eth2 eth3 Speed 1GbE 1GbE 10GbE 10GbE Mode Passive (bond0) Active (bond0) 1GbE to 10GbE migration instructions 9

NIC Bond type Speed Mode Active-Passive Prepare IP address worksheets Write down the following information and keep this information handy throughout the migration process for each storage node. In Table 4, enter information about the storage node before it is updated. In Table 5, enter the information about the storage node you will use during the update. Table 4 Pre-upgrade storage node information Motherboard:Port1 IP address Motherboard:Port2 IP address Bond address Cluster VIP Table 5 During upgrade, use this storage node information Motherboard:Port1 IP address to use Motherboard:Port2 IP address to use Bond0 IP address to use Which 10GbE interface to use (eth2 or eth3) for bond Which 1GbE interface to use for bond (Motherboard:Port1 or Motherboard:Port2) Cluster VIP (if different from step 4) Put the management group into maintenance mode 1. Halt all I/O to the volume(s). 2. Via the iscsi initiator, log off all the volumes attached to this cluster. 3. Right-click the management group in the navigation window and select Shutdown Management Group to place the group into Maintenance mode. The following message opens: 10 Instructions for migrating bonded interfaces in a SAN/iQ cluster from 1GbE to 10GbE Ethernet

4. Click Shut Down Group. You are next prompted to confirm the management group shutdown. 5. Click Shut Down Group to continue the shutdown process. 6. Verify that all the storage nodes in the management group are powered OFF. Install the hardware and the software upgrade patch Follow the instructions in the Hardware Upgrade Guide to install the 10GbE network card and additional memory. 1. Power ON the storage nodes. 2. Rediscover the storage nodes in the CMC. 3. Wait for the Store to become READY on all storage nodes. 4. Make sure the management group is operating in the Normal mode. (Once all storage nodes are up with all SAN/iQ services running properly, the CMC shows the management group in Normal mode). 5. Install Patch 10041 on all the upgraded storage nodes as described in "Upgrading the SAN/iQ Software" in the Hardware Upgrade Guide. The patch installs the required drivers and firmware to use the HP IB 4X DDR Conn-X PCI-e G2 Dual Port HCA. a. Right-click on an upgraded storage node and select Install Software. The Install Software window opens. The completed window is shown below, after finding the patch file and selecting the storage nodes to upgrade. 1GbE to 10GbE migration instructions 11

b. Click Install. A confirmation message opens, shown below. c. Click Install to start the upgrade patch installation. Patch 10041 will be installed on the selected storage nodes and the storage nodes will be rebooted. NOTE: If volumes were online, then the CMC waits for those volumes to resync before the patch installation can complete successfully. This resync could take a while depending on the amount of data that was written while the storage node was rebooting. NOTE: The cluster may continue flashing the warning symbol while the volumes are resyncing. Clicking on the cluster resolves the blinking. 6. After the storage nodes finish rebooting, log in to each storage node in the management group and navigate to the TCP/IP Network tab window. You should see two Mellanox Technologies ConnectX EN 10GigE devices on the TCP/IP tab. 12 Instructions for migrating bonded interfaces in a SAN/iQ cluster from 1GbE to 10GbE Ethernet

Configure the 10GbE ports for SAN/iQ communication using the CMC For each storage node in the cluster, configure the ports as follows: 1. Right-click the existing bond and delete it. (This is the old ALB bond of the two 1GbE interfaces.) 2. Search for the storage node using the Find dialog. 3. Log in to the management group (if necessary). 4. Make sure the storage node Storage Server status is Normal before proceeding. 5. On the TCP/IP tab window, right-click the eth2 interface and select Edit. 6. In the Edit TCP/IP Configuration window, select one of the following options to assign an IP address: Obtain an IP address automatically using the DHCP/BOOTP protocol IP Address, and manually assign an available IP address If you are prompted with the following message, click OK to continue. The condition described is not actually true. 7. When the following confirmation prompt opens, click OK to confirm the TCP/IP settings change on this storage node. The storage node reboots. 8. After the storage node reboots, search for it using the Find dialog. 9. Log in to the management group (if necessary). 10. Log in to the storage node. 11. Verify that the eth2 interface was assigned an IP address successfully. 1GbE to 10GbE migration instructions 13

Configure the Active-Passive bond using eth2 and Motherboard:Port1 (RECOMMENDED) The following instructions describe how to configure the storage node network bonding for the high availability Active-Passive configuration. This configuration takes advantage of the speed of the 10GbE interface on the adapter while providing failover protection through the 1GbE interface on the motherboard. Motherboard:Port1 (1GbE) Motherboard:Port2 (1GbE) eth2 (10GbE) eth3 (10GbE) SAN/iQ Interface Passive (Ready) Active Bond0 Creating the Active-Passive bond 1. Before proceeding, make sure both the Motherboard:Port1 interface and the eth2 interface have consistent network settings. You can view individual TCP settings on the TCP Status tab window. 2. Select the eth2 interface in the CMC. This NIC will be the Active NIC in the bond. 3. Hold down Ctrl and select the Motherboard:Port1 interface. This NIC will be the Passive NIC in the bond. 4. Click TCP/IP Tasks and select New Bond. The Create Bond Configuration window opens. 5. Under Type, select Active-Passive and click OK. A confirmation prompt opens. 6. Click OK to confirm the TCP/IP settings change. 7. Search for the storage node using the Find function. 8. Log in to the management group (if necessary). 9. Log in to the storage node. Verifying the bond 1. Verify on the TCP/IP tab window that the bond was created successfully. 2. Switch to the TCP Status tab. 3. Verify that the status of the 10GbE NIC eth2 interface is Active and the Preferred column is Yes. a. If the status of the 10GbE NIC eth2 interface is not shown as Active and the Preferred column is empty, then select the eth2 interface and right-click and select Set Preferred. b. Verify that the status of the eth2 interface is now shown as Active. c. Verify that the Preferred column of the eth2 interface now shows Yes. d. Verify that the status of the Motherboard:Port1 interface is now shown as Passive (Ready). 14 Instructions for migrating bonded interfaces in a SAN/iQ cluster from 1GbE to 10GbE Ethernet

4. Switch to the Communication tab and verify the SAN/iQ Interface is set to communicate via the Active-Passive bond you just created. Changing the VIP if required 1. Select the Cluster node and select the ISCSI tab. 2. Select the existing VIP address, click ISCSI Tasks and select Edit VIP & Subnet mask. 3. Change the VIP to a valid VIP for the new bond/network environment. 4. Add the bond IP address to the Find by Node IP or Hostname list and rediscover this storage node. NOTE: Delete the existing IP address that was being used to discover this storage node. The SAN/iQ Storage Server on this storage node will restart to allow the networking changes to take effect. Wait for the Storage Server to become Normal before proceeding. 5. Navigate to the node's TCP/IP Network category. 6. Select the Communication tab to verify that the Manager IP Addresses are correctly updated with the eth2 interface IP address of this node. If not, click Communication Tasks and select Update Manager IP Addresses. At this point, the SAN is ready to communicate via the 10GbE interface. Preparing your host server to be 10GbE capable While reconnecting to the iscsi volumes, configure the iscsi initiator on the host server to communicate via the 10GbE interface for all iscsi communication. You have successfully upgraded your existing SAN to 10GbE Ethernet. Configure the 10GbE and 10GbE ALB bond (using eth2 and eth3) CAUTION: Bonding both the ports on the 10GbE network adapter and then using this bond for all SAN/iQ communication could pose a risk to your volume and snapshot availability in the event of any network connectivity and/or functionality issues with the 10GbE adapter. If you set up this bond configuration, make sure you configure your volumes and snapshots for 2-way or higher replication to ensure that your volumes and snapshots remain available at all times. This example describes how to configure two 10GbE interfaces into a Balance ALB bond. Note that this configuration does not provide the failover protection of the Active-Passive bond described previously. Motherboard:Port1 (1GbE) Motherboard:Port2 (1GbE) eth2 (10GbE) eth3 (10GbE) SAN/iQ interface ALB bond ALB bond Bond0 1GbE to 10GbE migration instructions 15

Creating the ALB bond 1. Navigate to the TCP/IP Network tab window. 2. Right-click the eth3 interface and select Edit. 3. In the Edit TCP/IP Configuration dialog, assign a valid IP to eth3. 4. If you are prompted with an error like this, click OK to continue. The condition described is not actually true. 5. Click OK to confirm the TCP/IP settings change. 6. Search for the storage node using the Find function. 7. Log in to the management group (if necessary). 8. Log in to the storage node. 9. Verify that the eth3 interface was assigned the IP address successfully. 10. Hold down Ctrl and select the eth2 and eth3 interfaces. 11. Right-click and select New Bond. The Create Bond Configuration window opens. 12. Under Type, select Adaptive Load Balancing (ALB) and click OK. A confirmation prompt opens. 13. Click OK to confirm the TCP/IP settings change. 14. Search for the storage node using the Find function. 15. Log in to the management group (if necessary). 16. Log in to the storage node. 16 Instructions for migrating bonded interfaces in a SAN/iQ cluster from 1GbE to 10GbE Ethernet

Verifying the bond 1. Verify on the TCP/IP tab window that the bond was created successfully. 2. Switch to the Communication tab and verify that the SAN/iQ Interface is set to communicate via the Balance-ALB bond interface that you just created. Changing the VIP if required 1. Select the Cluster node and select the ISCSI tab. 2. Select the existing VIP address, click ISCSI Tasks and select Edit VIP & Subnet mask. 3. Change the VIP to a valid VIP for the new bond/network environment. 4. Add the bond IP address to the Find by Node IP or Hostname list and rediscover this storage node. NOTE: Delete the existing IP address that was being used to discover this storage node. 5. The SAN/iQ Storage Server on this storage node will restart to allow the networking changes to take effect. Wait for the Storage Server to become Normal before proceeding. 6. Navigate to the node's TCP/IP Network category. 7. Select the Communication tab to verify that the Manager IP Addresses are correctly updated. If not, click Communication Tasks and select Update Manager IP Addresses. At this point, the SAN is ready to communicate via the 10GbE interface. Preparing your host server to be 10GbE capable While reconnecting to the iscsi volumes, configure the iscsi initiator on the host server to communicate via the 10GbE interface for all iscsi communication. You have successfully upgraded your existing SAN to 10GbE. 1GbE to 10GbE migration instructions 17

18 Instructions for migrating bonded interfaces in a SAN/iQ cluster from 1GbE to 10GbE Ethernet