Dual 3-color display makes operation easier!

Similar documents
panasonic.net/id/pidsx/global

The dual display means that the current value and the threshold value, it makes direct setting of threshold value

Head-separated Dual Display Digital Pressure Sensor DPC-L100 SERIES DPH-L100 SERIES. High-precision detection of fluid and air pressure

Head-separated Dual Display Digital Pressure Sensor DPC-100 SERIES DPH-100 SERIES

Head-separated Digital Pressure Sensor For Gas DP5 SERIES DPH SERIES. High speed response of 1/1,000 sec. High speed response 1 ms

One step ahead in performance and mounting ease

EF-S1 SERIES. Continuously check invisible static electricity in lines. Constantly check static in lines!

GL SERIES. Compact & Low Price Inductive Proximity Sensor. Wide variety, high performance in surprisingly small body at low cost.

No. 1. The World s in Compactness. Amplifier Built-in Ultra-minute Photoelectric Sensor EX-Z SERIES panasonic.net/id/pidsx/global

The World s in Compactness. * Among photoelectric sensors with built-in amplifier, as of June 2015 (survey by our company)

Connector Built-in U-shaped Micro Photoelectric Sensor. Approximately 60 % of previous model Detachable

Cylindrical Compact Inductive Proximity Sensor Amplifier Built-in. panasonic.net/id/pidsx/global

GA-311 GH SERIES. Compact Inductive Proximity Sensor Amplifier-separated. High-speed response and excellent workability. IP67G sensor head variations

GA-311 GH SERIES. Compact Inductive Proximity Sensor Amplifier-separated. High-speed response and excellent workability

GX SERIES. Cylindrical Compact Inductive Proximity Sensor Amplifier Built-in. Robust enclosure and flexible cable types are also available

Ultra-small U-shaped Micro Photoelectric Sensor. Extremely small size enables space saving!! 12 mm in

Suitable for detecting transparent films or transparent bottles

PM-24 SERIES. Ultra-small U-shaped Micro Photoelectric Sensor. Extremely small size enables space saving!! ( ) Equipped with two independent outputs

High-speed sampling and high resolution. The new choice for even more variegated data collection and processing.

NA1-5. Ultra-slim Body 25mm Beam Pitch Area Sensor. Even a Slim Hand Is Detected by the 25mm Pitch Beam Curtain AREA SENSORS.

High-speed sampling and high resolution. The new choice for even more variegated data collection and processing.

3-step setting 2. 2-Color Display High-Precision Digital Pressure Switch. ZSE30A(F)/ISE30A Series. Added vacuum range.

PM2 SERIES. Convergent Reflective Micro Photoelectric Sensor. Convergent reflection sensing ensures stable detection

High-speed sampling and high resolution. The new choice for even more variegated data collection and processing.

Compact Inductive Proximity Sensor

PM2 SERIES. Convergent Reflective Micro Photoelectric Sensor. Convergent reflection sensing ensures stable detection

Capable of diagnosing own state and reporting to the host device

Ultra-slim Body Picking Sensor NA1-PK5 SERIES NA1-5 SERIES. Even a slim hand is detectable by the 25 mm in pitch beam area sensor

SERIES. FX-311 realizes the ultimate in ease-of-operation. Its operation enables easy and full use of latest technology.

EX-30SERIES. Threaded Miniature Photoelectric Sensor. The next-generation New Form series. A new alternative to fiber sensors. M4(Reflective type: M6)

Low Price Rectangular-shaped Inductive Proximity Sensor. The GL-N12 series is recommended to large volume users for cost reduction.

DC 3-wire Cylindrical Inductive Proximity Sensor. Long sensing range

PM2 SERIES. Convergent Reflective Micro Photoelectric Sensor. Convergent reflection sensing ensures stable detection

SERIES Amplifier Built-in Miniature-size Photoelectric Sensor

The GL-N12 series is recommended to large volume users for cost reduction. Exclusive mounting bracket. Cost saving. Conventional model.

Adjustable Range Reflective Photoelectric Sensor Amplifier Built-in

DC 3-wire Cylindrical Inductive Proximity Sensor. Long sensing range

DC 2-wire Cylindrical Inductive Proximity Sensor

GX-5SU(B) is just 5.4 mm 0.213in in diameter, the smallest in existing DC two-wire sensors. It saves you space.

GP-X SERIES Conforming to EMC Directive

High-speed sampling and high resolution. The new choice for even more variegated data collection and processing.

panasonic.net/id/pidsx/global CCD The sensor can be used for various applications with its binary data output with four different sensing modes.

Optimum sensing capability for LCD manufacturing

Plug-in unit extension block One sensor extension block allows four plug-in units to be added. Power cable for sensors. Snap-connector inputs

Color Detection Fiber Sensor FZ-10 SERIES. Reliable and precise color discrimination. Red, green and blue LEDs. Easy set up

High Accuracy Eddy Current Type Displacement Sensor. Linearity 0.5 % F.S.

Ultra-compact Laser Collimated Beam Sensor HL-T1 SERIES. Ultra-compact sensor head A high-functionality intelligent controller

From ultra-thin lead frames to iron sheets... Double feed detection of various metal sheets

Long sensing range of 500 mm in (HL-T1005A, HL-T1010A) and 2 m ft (HL-T1001A) are available. Adoption of a Class 1 laser

MPS-32. Pressure Sensors MPS-32 2-Color Panel Mount. Features. Green Display. MPS-32 Programming Options

High-speed sampling and high resolution. The new choice for even more variegated data collection and processing.

From ultra-thin lead frames to iron sheets... Double feed detection of various metal sheets

The GL-N12 series is recommended to large volume users for cost reduction. Exclusive mounting bracket. Cost saving. Conventional model

Ultra-compact Laser Collimated Beam Sensor HL-T1 SERIES. Ultra-compact sensor head A high-functionality intelligent controller

NPN open-collector transistor (Judgment output) Current / voltage output (Linear output)

panasonic.net/id/pidsx/global Up to 16 I/O devices can be connected at once using MIL connectors

Convergent Reflective Micro Photoelectric Sensor

Pressure Switch CE40. Digital settings available via IR data communication without actually applying pressure to the unit

NEW product. Large digital pressure sensor 31series. Easily viewable LCD dual displays. High level visibility with 3-color display.

PM2 SERIES. Convergent Reflective Micro Photoelectric Sensor. Convergent reflection sensing ensures stable detection. Hardly affected by background

SERIES. Ultra-compact Photoelectric Sensor. Long sensing range

NEW product. Large digital pressure sensor 31series. Easily viewable LCD dual displays. High level visibility with 3-color display.

Long sensing range. 2 m ft. Retroreflective type. 200 mm in. Diffuse reflective type. 160 mm in

U-shaped Type/Convergent Reflective Type. onlinecomponents.com

Series Pressure Sensor Instruction Sheet

Even a specular background does not affect the sensing performance if the sensor is located 30mm away from it (when directly opposite).

LCD Readout Digital Pressure Switch

LS-500 SERIES. Digital Laser Sensor Amplifier-separated. Industry s smallest* Industry s smallest* + Stainless steel (SUS) enclosure

ISE5B. Series ZSE5B. Digital Pressure Switch. With Backlight. (For vacuum) (For positive pressure) For General Purpose Fluids

Laser Collimated Beam Sensor

Pressure sensors SPAN

Precise sensing in wide area. Sensing area: mm in Minimum sensing object: "0.1 mm "0.004 in Repeatability: 10!m 0.

Type Pressure range description Part number

Ultra-compact Laser Collimated Beam Sensor HL-T1 SERIES. Ultra-compact sensor head A high-functionality intelligent controller

Digital pressure sensor

Series Pressure Sensor Instruction Sheet

Mini Photoelectric Sensor

A line width of approx. 240 mm in (typical) at a 1,000 mm in sensing distance

Thread length (overall length) material

LS-500 SERIES. Digital Laser Sensor Amplifier-separated. Industry s smallest* Industry s smallest* + Stainless steel (SUS) enclosure

Remote I/O Unit with Connectors for Light Curtain CC-Link Safety System. panasonic.net/id/pidsx/global

187 HG-C SERIES panasonic.net/id/pidsx/global Reliable detection in repeatability 10 μm mil Overwhelmingly stable

Ordering Information. Smart Sensors (Inductive Displacement Type) ZX Series. Sensors

DIGITAL LASER SENSOR. User friendly, high precision Digital Laser Sensor SERIES mm in. Easy 1 Installation.

USER S MANUAL High-Speed High-Accuracy Eddy Current Digital Displacement Sensor. GP-X Series

EE-SPX74/84. Ordering Information. Compact Sensor for High-Density Mounting with Easy Snap-In Connector. H Connector features a built-in safety

Both Compact and Robust. Safety Light Curtain SF4D SERIES. New Concept. GB Conforming to Compact & Robust panasonic.net/id/pidsx/global

E3X-NA. Adjuster type standard that is the culmination of true ease and simplicity. Super Manual Fiber Amplifier. Features

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

Electronic pressure switch with display Model PSD-4

14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

Option 2. Nil. Note 1) Option 1. Note With waterproof seal and mounting screw. With waterproof seal and mounting screw. 48 conversion adapter

Amplifi er-separated. A line width of approx. 240 mm in (typical) at a 1,000 mm in sensing distance

PRCMT18-5DO PRCMT18-5DC PRCMT18-5DO-I PRCMT18-5DC-I

Ferrous metal (The sensing distance decreases with non-ferrous metal.) Power supply voltage (operating voltage range)

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

Ultra-compact Laser Collimated Beam Sensor HL-T1 SERIES. Ultra-compact sensor head A high-functionality intelligent controller

Superb craftsmanship!

Capacitive Proximity Sensor E2K-X

Transcription:

7 Dual Display Digital Pressure Sensor For Gas SERIES Ver. Related Information General terms and conditions... F- Glossary of terms... P.56~ Korea s S-mark... P.6 guide... P.699~ General precautions... P.566 PHOTO PHOTO Ver. Certified [DP-(A)/(A) only] Recognition * Passed the UL 99 Environment Test * UL 6C- compatible, Passed the UL 99 Environment Test based on SEMI S-. [Category applicable for semiconductor manufacturing: TWW, Process Equipment] [Applicable standards: UL 6C-] [Additional test / evaluation standards as per intended use: UL 99, SEMI S-] MEASURE Dual -color display makes operation easier! Digital Auto reference With analog output Achieved further efficiency with upgrades, keeping the same operability UPGRADE Superior visibility Improved visibility in Improvements to the digital display deliver a wide viewing angle along with increased clarity. The display pressure range and set pressure range have also been increased. panasonic.net/id/pidsx/global Old series New series UPGRADE Long-distance transmission of analog output Addition of analog current output capability to multifunctional models Users can now select either voltage output or current output as analog output according to their application.

Dual Display Digital Pressure Sensor SERIES Ver. 7 APPLICATIONS Confirming suction of electronic component Confirming reference pressure Air-leak test for PET bottles PHOTO PHOTO UPGRADE Reduced environmental impact % lower power consumption (during normal operation) Thanks to a redesign of its circuitry, power consumption of the low-power-consumption series during normal operation has been reduced by %. The display is shut off entirely during ECO / FULL mode operation for power savings of up to 5 % compared to normal operation, and display brightness is lowered during ECO / STD mode operation for power savings of up to % compared to normal operation. Old series 8 mw (normal operation) % lower after update New series 7 mw (normal operation) Up to 5 % lower in ECO mode MEASURE Normal operation 7 mw ECO / FULL operation 6 mw UPGRADE Enhanced power circuitry Addition of a reverse polarity protection circuit to the transistor output circuit To prevent from breakage due to miswiring. Current value and threshold value can be checked at the same time! Dual display allows direct setting of threshold value Equipped with a mm in square compact-sized dual display. The current value and the threshold value can be checked at the same time, so the threshold value can be set and checked smoothly without switching to another screen mode. ON/OFF operations still continue while the threshold values are being set, so setting to the same sensitivity as dial control-type sensors is possible. Key lock function is equipped as well. Current value Threshold value

75 Dual Display Digital Pressure Sensor SERIES Ver. PHOTO PHOTO MEASURE -color display (Red, Green, Orange) The main display changes color in line with changes in the status of output ON/OFF operation, and it also changes color while setting is in progress. The sensor status can therefore be understood easily, and operating errors can be reduced. Main Display OFF: Green (or Red) ON: Red (or Green) During normal operation BASIC PERFORMANCE SET: Orange During setting All models in the line-up are compound pressure types No sensor settings are required to switch between positive pressure and negative pressure, so that the number of registered part numbers can be decreased. kpa kpa kpa For low pressure DP- For high pressure FUNCTIONS <> Ideal for applications such as suction. No mis-operations due to vacuum breakdown occur. <> Ideal for applications such as checking reference pressure. Can also be used for simple suction. DP- MPa Copy function reduces man-hours and human error Readable digital display! Alphanumeric indication in segments is used. This improved visual checking. High performance accomplished Low pressure type The low pressure type displays measurements in. kpa at a resolution of /, and has a response time of.5 ms (variable up to 5, ms), ±.5 % F.S. temperature characteristics and ±. % F.S. repeatability, giving it high performance. Resolution: /, Response time:.5 ms Temperature characteristics: ±.5 % F.S. Repeatability: ±. % F.S. Displays measurements in. kpa Sensors can be connected to a master sensor one by one, and a copy of the setting details for the master sensor can be transmitted as data to other sensors. If making the same settings for multiple sensors, this prevents setting errors among other sensors and in addition, when machinery design are changed, there would be less change in work orders. Details transmitted Copying via wiring Master sensor +V Power supply +V Slave sensor Details copied Details received V V Comparative output Comparative output Comparative output Comparative output Note: Settings cannot be copied from the new version (Ver. ) to the old version. However, settings can be copied from the old version to the new version (Ver. ). The sensor s setting operation mode has a -level configuration to suit the frequency of use The setting levels are clearly separated into RUN mode for operation settings that are carried out daily, MENU SETTING mode for basic settings, and PRO mode for special and detailed setting. These make setting operations easy to understand and easy to carry out. RUN mode Settings such as threshold value adjustment and key lock operation can be carried out while the sensor is operating. Simple setting Special and detailed setting RUN mode MENU SETTING mode PRO mode MENU SETTING mode PRO mode Basic settings such as output mode setting and NO/NC switching can be carried out. High-level function settings such as hysteresis adjustment and the copy function can be carried out.

Dual Display Digital Pressure Sensor SERIES Ver. 76 FUNCTIONS Equipped with independent dual output and three output modes Equipped with two independent comparative outputs, and separate sensing modes can be selected for each of them. Since there are two comparative outputs, one of the comparative outputs can even be used for alarm output. In addition, output, which is not being used, can be disabled. Vacuum breakdown can also be notified during suction applications! ON Comparative output EASY mode OFF ON Comparative output EASY mode OFF Suction checking Vacuum breakdown checking kpa P- kpa P- Reference pressure alarm output is possible during reference pressure checking! ON Comparative output Hysteresis mode OFF ON Comparative output EASY mode OFF kpa Reference pressure checking Alarm output Lo- Hi- P- EASY mode Standard type This mode is used for comparative output ON/OFF control. Pressure P H (Hysteresis) ON Comparative output OFF H: Fixed Notes: ) Hysteresis can be fixed to one of eight different levels. ) appears in the sub display for comparative output, and appears for comparative output. Hysteresis mode This mode is used for setting comparative output hysteresis to the desired level and for carrying out ON/OFF control. Pressure Hi Lo ON Comparative output OFF H (Hysteresis) H: digit or more Note: or appears in the sub display for comparative output, and or appears for comparative output. Window comparator mode This mode is used for setting comparative output ON and OFF at pressures within the setting range. H (Hysteresis) Hi H (Hysteresis) Lo ON Comparative output OFF H: Fixed Notes: ) Hysteresis can be fixed to one of eight different levels. ) or appears in the sub display for comparative output, and or appears for comparative output. Pressure PHOTO PHOTO MEASURE Possible to switch over analog output and external input Multi-function type Multi-function type that enables the selection of analog output (voltage/current) or external input (auto-reference/ remote zero-adjustment) is available. It complies a wide range of applications. Multi-function type Comparative output Analog output or External input is lighting. Voltage Low pressure type: to 5 V, High pressure type:.6 to 5 V Current Low pressure type: to ma, High pressure type:. to ma Auto-reference/remote zero-adjust

77 Dual Display Digital Pressure Sensor SERIES Ver. PHOTO PHOTO MEASURE FUNCTIONS Equipped with auto-reference/remote zero-adjustment functions. More precise pressure management is achieved with a minimum of effort If the reference pressure of the device changes, two functions are selectable. One is auto-reference function, which partially shift the comparative output judgment level by the amount that the reference pressure shifts. The other is remote zero-adjustment function, which can reset the display value to zero via external input. These functions are ideal for places where the reference pressure fluctuates wildly, or where fine settings are required. With auto-reference function applied Comparative output: Window comparator mode Hi-, Lo- 5 Sets the absolute threshold level Auto-reference input The display remains at and only the threshold level is changed. 5 OK Threshold level after applying auto-reference input 5 Threshold level before applying auto-reference input Trial Pressure 5 Auto-reference input value Time When auto-reference input is applied, the reference pressure is added to the threshold level. If the reference pressure changes to or, the auto-reference input compensates for this every time by changing the threshold level, so any variation in the filling pressure can be ignored. Sub display can be customized The sub display can be set to indicate any other desired values or letters apart from the threshold value. This eliminates the need for tasks such as affixing a label to the device to indicate the normal pressure value. Setting details can be recognized at a glance The setting details appear in the digital display. Because the settings are in numeric form that can be easily understood, it is useful such as when receiving technical support by telephone. nd digit: Setting status for comparative output st digit: Setting status for comparative output Multi-function type With remote zero-adjustment function applied Comparative output: Window comparator mode Hi-, Lo- 5 Sets the absolute threshold level Remote zero-adjustment input The display is forced to, and only the filling pressure drop range is displayed. 5 5 Pressure 5 5 Threshold level before applying remote zero-adjustment input Trial OK Threshold level after applying remote zero-adjustment input Displayed when remote zero-adjustment input is applied Time When remote zero-adjustment input is applied, the reference pressure is forced to. If the reference pressure changes to or, the remote zero-adjustment input adjusts the reference pressure to every time the reference pressure changes, so any variation in the filling pressure can be ignored. rd digit: Threshold value setting th digit: Display color setting Peak hold and Bottom hold functions The peak values and bottom values for fluctuating pressures can be displayed using the dual display. Blinks alternately 5th digit: Response time setting 6th digit: Display unit setting 8th digit: ECO mode setting 7th digit: Display refresh rate setting Energy-saving design! Equipped with an ECO mode This mode lowers the display luminance to cut power consumption by approximately %. The displays can also be turned off completely to achieve a power saving of approximately 5 %. Normal ECO-STD Power consumption Approx. % less Power consumption Approx. ECO-FULL 5 % less Current consumption for V power supply: ma or less Current consumption for V power supply: ma or less Current consumption for V power supply: 5 ma or less

Dual Display Digital Pressure Sensor SERIES Ver. 78 MOUNTING Tight installation to panels is possible An exclusive mounting bracket that is suitable for to 6 mm.9 to.6 in panel thickness is available. Tight installation is possible Neat and space saving Front protection cover available MS-DP- An exclusive mounting bracket (MS-DP-) that supports tight installation is available Space savings can also be achieved even when an L-shaped mounting bracket is used. MS-DP- MS-DP-5 A single mounting hole! Tight installation is possible PHOTO PHOTO MEASURE Ceiling mounting Floor mounting Rear mounting Positioning bosses for easier mounting bracket installation Cable can be connected with one-touch Connector attached cable ( m 6.56 ft), as an accessory, can be connected easily with one-touch connection. * Connection cable * Options: m.8 ft / m 9.8 ft / 5 m 6. ft types are also available. Types without connector attached cable are also available Commercially-available connectors can be used for cable connections. Cables in required length can be used, so this contributes to reduction in waste of unwanted cables. Environmentally friendly DP- -J Commercially-available parts can be used! * Refer to p.7 for recommended commercially-available connectors.

79 Dual Display Digital Pressure Sensor SERIES Ver. PHOTO PHOTO MEASURE VARIETIES Short pressure port type is lightweight and takes up little space Compact size with a depth of only mm in, so that it can easily fit into narrow spaces. Further, g lighter than standard types. This reduces the loads on movable parts such as robot arms. Short pressure port type DP- -M(-P) M8 plug-in connector types are also available (Only for Europe) Mating cable CN-A-C (cable length m 6.56 ft) CN-A-C5 (cable length 5 m 6. ft) Standard type Short pressure port type DP- -M(-P) mm in * The illustration shows connection using an elbow joint. The elbow joint is sold separately. M8 connector + R /8 male thread Elbow joint Shortened to.5 mm.9 in! Light weight g approx. [Material: Stainless steel (SUS)] DP- -M DP- -E-P-J G /8 male thread Flat installation on the wall by shifting the direction of the pressure port For short pressure port type By mounting the flat attachment to DP- -M(-P), pressure port and cable can now be pulled out in downward, left or right directions. Flat mounting on surfaces such as the wall is made possible. Flat attachment MS-DP-F Conventional model DP / DP series can be switched over to series. Conventional model Rc/8 conversion bushing is available. Compatible with conventional model For short pressure port type By equipping the push-in converter with DP- -M(-P), pressure port can be converted from to Rc/8 female thread. Bore diameter conversion to the DP / DP series is possible. Rc/8 female thread possible directions to mount mm.787 in pitch Model No. MS-DP-FM MS-DP-FR MS-DP-FN MS-DP-FE mm.787 in pitch Pressure port Rc/8 female thread NPT/8 female thread G/8 female thread Conversion bushing MS-DP-7

Dual Display Digital Pressure Sensor SERIES Ver. 7 ORDER GUIDE Standard pressure port type Short pressure port type Europe Asia Asia North America M8 plug-in connector type Type Standard Multi-function Standard Multi-function Standard Multi-function Standard Multi-function Standard Multi-function Type without connector attached cable Appearance * CN-A-C Connector attached ( cable m 6.56 ft ) is attached. Excluding M8 plug-in ( connector type ) Rated pressure range Model No. Pressure port. to +. kpa. to +. MPa. to +. kpa. to +. MPa. to +. kpa. to +. MPa. to +. kpa. to +. MPa. to +. kpa. to +. MPa. to +. kpa. to +. MPa. to +. kpa. to +. MPa. to +. kpa. to +. MPa. to +. kpa. to +. MPa. to +. kpa. to +. MPa DP- DP- + DP-A R /8 male thread DP-A DP--E-P DP--E-P + DP-A-E-P G /8 male thread DP-A-E-P DP--E-P-J DP--E-P-J + G /8 DP-A-E-P-J male thread DP-A-E-P-J DP--N DP--N-P DP--N DP--N-P + DP-A-N NPT /8 male thread DP-A-N-P DP-A-N DP-A-N-P DP--M DP--M-P DP--M DP--M-P DP-A-M DP-A-M-P DP-A-M DP-A-M-P Type without connector attached cable CN-A-C is available. When ordering this type, suffix -J to the Model No. (Excluding M8 plug-in connector type and short pressure port type) (e.g.) Type without connector attached cable of DP--N is DP--N-J Comparative output Accessory CN-A-C (Connector attached cable m 6.56 ft)

OUT -ADJ OUT MODE 7 Dual Display Digital Pressure Sensor SERIES Ver. Designation Connector attached cable Connector attached cable Bending-resistant cable M8 connector attached cable Connector Sensor mounting bracket Panel mounting bracket Front protection cover Conversion bushing Flat attachment Model No. CN-A-C CN-A-C (Note) CN-A-C CN-A-C5 CN-A-R-C CN-A-R-C CN-A-R-C CN-A-R-C5 CN-A-C CN-A-C5 CN-A MS-DP- MS-DP-5 MS-DP- MS-DP- MS-DP- DPX- MS-DP-7 MS-DP-FM MS-DP-FR MS-DP-FN MS-DP-FE Note: The connector attached cable CN-A-C is supplied with the series. (Excluding M8 plug-in connector type). Panel mounting bracket, Front protection cover MS-DP- MS-DP- MS-DP- Front protection cover DPX- (optional) can be installed on MS-DP-. Front protection cover MS-DP- Panel mounting bracket MS-DP- Length: m.8 ft Length: m 6.56 ft Length: m 9.8 ft Length: 5 m 6. ft Length: m.8 ft Length: m 6.56 ft Length: m 9.8 ft Length: 5 m 6. ft Length: m 6.56 ft Description Length: 5 m 6. ft Set of housings and contacts. mm -core cabtyre cable with connector on one end Cable outer diameter: ø.7 mm ø.6 in. mm -core bending-resistant cabtyre cable with connector on one end Cable outer diameter: ø.7 mm ø.6 in For M8 plug-in connector type The connector on one end Cable outer diameter: ø mm ø.57 in Allows sensors to be installed on the flooring or ceiling. Multiple sensors can also be mounted closely. Allows sensors to be installed on the wall. Multiple sensors can also be mounted closely. Allows installation to panels with thickness of to 6 mm.9 to.6 in. Multiple sensors can also be mounted closely. Allows replacement from DP / DP series to series. For newly designed set-up, please use panel mounting bracket MS-DP- for panel mounting. Protects the adjustment surfaces of sensors. (Can be attached when using the panel mounting bracket MS-DP-) Protects the adjustment surfaces of sensors. (Can be attached when using the panel mounting bracket MS-DP-) By equipping with DP- -M(-P), pressure port can be converted to Rc /8 female thread. Replacement from DP / DP series is possible. Rc /8 female thread NPT /8 female thread G /8 female thread For DP- -M(-P) Pressure port and cable can now be pulled out in downward, left or right directions. Flat mounting on surfaces such as the wall is made possible. DP / DP DP- ñ.kpa Remove Remove Insert Mounting holes for DP / DP series can be used as is. Panel mounting bracket MS-DP- Connector attached cable CN-A-C CN-A-R-C M8 connector attached cable CN-A-C..6 MS-DP-5 ø ø.57 ø9 ø.5 (Unit: mm in) Sensor mounting bracket MS-DP- Sensor mounting bracket MS-DP- Sensor mounting bracket MS-DP-5 M (length 6 mm.6 in) screws with washers Accessory for ( MS-DP- ) M (length 6 mm.6 in) screws with washers Accessory for ( MS-DP-5 ) Conversion bushing MS-DP-7 M5 female thread Rc /8 female thread Flat attachment MS-DP-FM MS-DP-FR MS-DP-FN MS-DP-FE Net weight: MS-DP-FM 5g approx. MS-DP-FR/FN/FE 5g approx. Two M (length 8 mm.5 in) screws, two M (length mm.787 in) screws are attached. Conversion bushing MS-DP-7 Recommended connector Contact: SPHD-T-P.5, Housing: PAP-V-S (Manufactured by J.S.T. Mfg. Co., Ltd.) Note: Contact the manufacturer for details of the recommended products. Recommended crimping tool Model No.: YC-6R (Manufactured by J.S.T. Mfg. Co., Ltd.) Note: Contact the manufacturer for details of the recommended products. Recommended connector (e-con) Applicable connector: 7-- FL (Manufactured by M Japan Limited) Note: Contact the manufacturer for details of the recommended products.

Dual Display Digital Pressure Sensor SERIES Ver. 7 SPECIFICATIONS Asia (Note ) Europe M8 plug-in connector type Item North America (Note ) CE marking directive compliance Type of pressure Rated pressure range Set pressure range Pressure withstandability Applicable fluid Selectable unit Supply voltage Power consumption Comparative output Comparative output, Comparative output (Note ) Environmental resistance Output operation / Output modes Hysteresis Repeatability Response time Short-circuit protection External input (Note ) Auto-reference function / Remote zero-adjustment function Analog voltage output (Note ) Analog current output (Note ) Display Indicator Model No. Displayable pressure range Protection Ambient temperature Ambient humidity Voltage withstandability Insulation resistance Vibration resistance Type Shock resistance Temperature characteristics Pressure port Material Connecting method / Cable length Weight Accessories Standard Multi-function DP-(-M)(-P) DP-(-M)(-P) DP-A(-M)(-P) DP-A(-M)(-P) DP--E-P DP--E-P DP-A-E-P DP-A-E-P DP--E-P-J DP--E-P-J DP-A-E-P-J DP-A-E-P-J DP--N(-P) DP--N(-P) DP-A-N(-P) DP-A-N(-P) EMC Directive, RoHS Directive Gauge pressure. to +. kpa. to +. MPa. to +. kpa. to +. MPa. to +. kpa. to +. MPa. to +. kpa. to +. MPa. to +. kgf/cm to +, kpa. to +. kgf/cm to +, kpa. to +. bar. to +. kgf/cm. to +. bar. to +. kgf/cm.6 to +.6 psi. to +. bar.6 to +.6 psi. to +. bar 757 to +757 mmhg 757 to +757 mmhg 9.8 to 9.8 inhg.6 to +6. psi 9.8 to 9.8 inhg.6 to +6. psi 5 kpa.5 MPa 5 kpa.5 MPa Non-corrosive gas : kpa, kgf/cm, bar, psi, mmhg, inhg, : MPa, kpa, kgf/cm, bar, psi to V DC ± % Ripple P-P % or less Normal operation: 7 mw or less (Current consumption ma or less at V supply voltage) ECO mode: 8 mw or less at STD (Current consumption ma or less at V supply voltage) 6 mw or less at FULL (Current consumption 5 ma or less at V supply voltage) <Asia (NPN output), North America (NPN output)> <Asia (PNP output), Europe, North America (PNP output)> Maximum sink current: ma Maximum source current: ma Applied voltage: V DC or less (between comparative output and V) Applied voltage: V DC or less (between comparative output and +V) Residual voltage: V or less (at ma sink current) Residual voltage: V or less (at ma source current) NO/NC (selectable by key operation) / EASY mode / Hysteresis mode / Window comparator mode Minimum digit (variable) (however, digits when using psi unit) ±. % F.S. (within ± digits) ±. % F.S. (within ± digits) ±. % F.S. (within ± digits) ±. % F.S. (within ± digits).5 ms, 5 ms, ms, 5 ms, 5 ms, ms, 5 ms, 5 ms,, ms, 5, ms, selectable by key operation Incorporated <Asia (NPN output), North America (NPN output)> <Asia (PNP output), Europe, North America (PNP output)> ON voltage:. V DC or less ON voltage: 5 V to +V DC OFF voltage: 5 to V DC, or open OFF voltage:.6 V DC or less, or open Input impedance: kω approx. Input impedance: kω approx. Input time: ms or more Input time: ms or more Output voltage: to 5 V DC Zero point: within V ±5 % F.S. Span: within V ±5 % F.S. Linearity: within ± % F.S. Output impedance: kω approx. Output current: to ma Zero point: ma ±5 % F.S. Span: 6 ma ±5 % F.S. Linearity: within ± % F.S. Load resistance: 5 Ω (max.) Output voltage:.6 to 5 V Zero point: within V ±5 % F.S. Span: within. V ±5 % F.S. Linearity: within ± % F.S. Output impedance: kω approx. Output current:. to ma Zero point: ma ±5 % F.S. Span: 7.6 ma ±5 % F.S. Linearity: within ± % F.S. Load resistance: 5 Ω (max.) digits + digits -color LCD display (Display refresh rate: 5 ms, 5 ms,, ms, selectable by key operation). to +. kpa. to +. MPa. to +. kpa. to +. MPa. to +. kgf/cm to +, kpa. to +. kgf/cm to +, kpa. to +. bar. to +. kgf/cm. to +. bar. to +. kgf/cm.6 to +.6 psi. to +. bar.6 to +.6 psi. to +. bar 757 to +757 mmhg 757 to +757 mmhg 9.8 to 9.8 inhg.6 to +6. psi 9.8 to 9.8 inhg.6 to +6. psi Orange LED Orange LED Comparative output operation indicator, comparative output operation indicator: Comparative output operation indicator: Lights up when comparative output is ON, ( Lights up when each comparative output is ON ) ( Analog voltage output operation indicator: Lights up when setting ) IP (IEC) to +5 C + to + F, Storage: to +6 C + to + F 5 to 85 % RH (No dew condensation or icing allowed), Storage: 5 to 85 % RH, V AC for one min. between all supply terminals connected together and enclosure 5MΩ or more with 5 V DC megger between all supply terminals connected together and enclosure to 5 Hz frequency, mm.8 in double amplitude or maximum acceleration 96 m/s, in X, Y and Z directions for two hours each (when panel is mounted: to 5 Hz frequency,.75 mm. in amplitude or maximum acceleration 9 m/s, in X, Y and Z directions for two hours each) m/s acceleration ( G approx.) in X, Y and Z directions three times each Within ±.5 % F.S. (at + C +68 F) Within ± % F.S. (at + C +68 F) Within ±.5 % F.S. (at + C +68 F) Within ± % F.S. (at + C +68 F) Asia: + R (PT) /8 male thread [excluding DP- -M(-P)], Europe: + G /8 male thread, North America: + NPT /8 male thread Enclosure: PBT (glass fiber reinforced), LCD display: Acrylic, Pressure port: Stainless steel (SUS), Mounting threaded part: Brass (nickel plated), Switch part: Silicone rubber Connector / Total length up to m 8.8 ft (less than m 98.5 ft when conforming to CE marking) is possible with. mm, or more, cable. Net weight: g approx. (DP- -M(-P): g approx.), Gross weight: g approx. (DP- -M(-P): g approx.) CN-A-C (Connector attached cable m 6.56 ft): pc. (excluding M8 plug-in connector type) Notes: ) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of + C +68 F. ) Model Nos. of Asia type having -M are short pressure port type. Model Nos. of Asia and North America types having the suffix -P are PNP output type. ) Only standard type is equipped with comparative output. ) Cannot be used at the same time.

7 Dual Display Digital Pressure Sensor SERIES Ver. I/O CIRCUIT AND WIRING DIAGRAMS DP- I/O circuit diagrams Standard type Sensor circuit Tr Tr Internal circuit Symbols D to D : Reverse supply polarity protection diode ZD, ZD : Surge absorption zener diode Tr, Tr : NPN output transistor Terminal arrangement diagram D ZD ZD D D (Brown) +V (Black) Load Comparative output Load ma max. (White) Comparative output ma max. (Blue) V DP- -P I/O circuit diagrams Standard type Sensor circuit Tr Tr Terminal No. Color code of connector attached cable Users circuit Terminal (Brown) +V D ZD ma max. (Black) Comparative output ZD ma max. Load (White) Comparative output Load (Blue) V Internal circuit Users circuit Symbols D : Reverse supply polarity protection diode ZD, ZD : Surge absorption zener diode Tr, Tr : PNP output transistor Terminal arrangement diagram DP- -E-P-J I/O circuit diagrams Standard type Sensor circuit Tr Tr Terminal arrangement diagram + Terminal No. Color code of connector attached cable Terminal Terminal No. Color code of connection cable (Brown) +V D ZD ma max. (Black) Comparative output ZD ma max. Load (White) Comparative output Load (Blue) V Internal circuit Users circuit Symbols D : Reverse supply polarity protection diode ZD, ZD : Surge absorption zener diode Tr, Tr : PNP output transistor Terminal + + to V DC ± % Multi-function type Sensor circuit 5V Tr Tr Symbols D to D : Reverse supply polarity protection diode ZD : Surge absorption zener diode Tr : PNP input transistor Tr : NPN output transistor Designation kω Internal circuit +V Comparative output D D (Brown) +V Standard type: Comparative output Multi-function type: Analog output or External input V to V DC ± % Designation +V Comparative output Standard type: Comparative output Multi-function type: Analog output or External input V to V DC ± % ZD D Multi-function type Sensor circuit Tr kω Tr D ZD D D Internal circuit Terminal No. Color code of connector attached cable (White) Analog output or External input Load (Black) Comparative output ma max. (Blue) V Users circuit (Brown) +V ma max. (Black) Comparative output (White) Analog output or External input Load (Blue) V Users circuit Symbols D to D : Reverse supply polarity protection diode ZD : Surge absorption zener diode Tr : PNP output transistor Tr : NPN input transistor Multi-function type Sensor circuit Tr Tr Designation +V Standard type: Comparative output Multi-function type: Analog output or External input V Comparative output + Terminal No. Color code of connector attached cable Terminal No. Color code of connection cable (Brown) +V D ZD ma max. k (Black) Comparative output + (White) Analog voltage output or External input D Load (Blue) V Internal circuit Users circuit Symbols D, D : Reverse supply polarity protection diode ZD : Surge absorption zener diode Tr : PNP output transistor Tr : NPN input transistor + NPN output type to V DC ± % PNP output type to V DC ± % PNP output type to V DC ± %

OUT -ADJ OUT MODE Dual Display Digital Pressure Sensor SERIES Ver. 7 PRECAUTIONS FOR PROPER Refer to p.566 for general precautions. Part description Never use this product as a sensing device for personnel protection. In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. The series is designed for use with non-corrosive gas. It cannot be used with liquid or corrosive gas. Comparative output operation indicator Comparative output operation indicator Work as analog voltage output operation indicator in Multi-function type Mode selection Decrement key key Increment key Main display Sub display Wiring Make sure that the power supply is off while wiring. Verify that the supply voltage variation is within the rating. If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.) terminal of the power supply is connected to an actual ground. In case noise generating equipment (switching regulator, inverter motor, etc.) is used in the vicinity of this sensor, connect the frame ground (F.G.) terminal of the equipment to an actual ground. Do not run the wires together with high-voltage lines or power lines or put them in the same raceway. This can cause malfunction due to induction. Incorrect wiring will cause problems with operation. The MS-DP- panel mounting bracket is available when switching from the DP / DP series. Front protective cover DPX- (optional) can be installed on MS-DP-. DP / DP An conversion bushing is available for when using the DP- -M short pressure port type. It can be used to switch between this model and the DP / DP series. When connecting to the pressure port, use a tightening torque of. N m or less. Rc 8 female thread The MS-DP-F flat attachment is available for when using the DP- -M short pressure port type. If using the MS-DP-F flat attachment (optional), install by following the procedures given below. Decide the direction of this product to mount with the sensor. DP- ñ.kpa Remove Insert Panel mounting bracket MS-DP- Remove Mounting holes for DP / DP series can be used as is. Conversion bushing MS-DP-7 Connection Do not apply stress directly to the connection cable leader or to the connector. Connector attached cable [CN-A(-R)-C ] Pressure port faces downward Pressure port faces leftward Note: It is not possible to mount this product such that the pressure port faces upward. Pressure port faces rightward Mounting MS-DP- / MS-DP-5 sensor mounting brackets are available separately, and it should be used for mounting. When tightening the sensor to the sensor mounting bracket, use a tightening torque of.5 N m or less. Sensor mounting bracket MS-DP- (Optional) M (length 6 mm.6 in) screws with washers Accessory for MS-DP- ( and MS-DP-5 ) The MS-DP- panel mounting bracket (optional) and the MS-DP- front protection cover (optional) are also available. Pressure port faces upward Mount this product with the M female threads of the sensor by using the attached M (length 8 mm.5 in) screws. The tightening torque should be.5 N m or less. M female thread M female thread M (length 8 mm.5 in) screw (Accessory) Mount this product with the mounting surface by using the attached M (length mm.787 in) screws. The tightening torque should be. N m or less. Groove Front protection cover MS-DP- (optional) Panel mounting bracket MS-DP- (optional) Connector attached cable M (length mm.787 in) screw (Accessory) Note: Take care that if the cable with connector is sticking out of the side groove of this product when mounting, the cable may disconnected.

75 Dual Display Digital Pressure Sensor SERIES Ver. PRECAUTIONS FOR PROPER Refer to p.566 for general precautions. Conditions in use for CE conformity The series is a CE conformity product complying with EMC Directive. The harmonized standard with regard to immunity that applies to this product is EN 6-6- and the following condition must be met to conform to that standard. Condition The line to connect with this sensor should be less than m 98.5 ft. Piping mm.7 in If connecting a commercially-available spanner coupling to the pressure port, attach a mm.7 in spanner ( mm.55 in spanner for -E type) to the hexagonal section of the pressure port to secure it, and tighten at a torque of 9.8 N m or less. If it is tightened using excessive torque, it may damage the coupling or the pressure port. In addition, wrap sealing tape around the coupling when connecting it to prevent leaks. If connecting a commercially-available joint to the pressure port of the DP- -M(-P), hold the main unit in your hand to steady it, and tighten to a torque of. N m or less. If it is tightened to an excessive torque, the joint or the main unit may become damaged. If connecting a commercially-available joint to the pressure port of the MS-DP-7, tighten to a torque of 9.8 N m or less. mm.55 in spanner The tightening torque should be N m or less when connecting a coupling to the pressure port of MS-DP-FM. Pressure port Coupling (Purchase separately.) When connecting the coupling to the pressure port of MS-DP-FR/FE/FN, hold the pressure port with a mm.55 in spanner and make sure that the tightening torque is 9.8 N m or less. In addition, in order to prevent any leakage, wind a sealing tape on the coupling when connecting. Flat attachment Make sure to mount MS-DP-F with the sensor properly. If it is not mounted properly, air leakage may occur. Take care that the excessive mounting and dismounting of this product may cause deterioration of the O-ring. If you touch the O-ring of MS-DP-F, or any scratch or dust, etc. is attached to it, air leakage may occur and the sensing performance may deteriorate. Take sufficient care when using and storing MS-DP-F. Others Use within the rated pressure range. Do not apply pressure exceeding the pressure withstandability value. The diaphragm will get damaged and correct operation shall not be maintained. Do not use during the initial transient time (.5 sec. approx.) after the power supply is switched on. Avoid dust, dirt, and steam. Take care that the sensor does not come in direct contact with water, oil, grease, or organic solvents, such as, thinner, etc. Do not insert wires, etc., into the pressure port. The diaphragm will get damaged and correct operation shall not be maintained. Do not operate the keys with pointed or sharp objects. RUN mode This is the normal operating mode. Setting item Threshold value setting Zero-adjustment function Key lock function Peak hold / bottom hold function MENU SETTING mode If the mode selection key is pressed and held for seconds in RUN mode, the mode will switch to MENU SETTING mode. If the mode selection key is pressed while a setting is being made, the mode will switch to RUN mode. In this case, the settings that have been changed will be entered. Setting item Comparative output output mode setting Comparative output output mode setting (standard type only) Analog output / external input switching (multi-function type only) NO/NC switching Response time setting Description The threshold values for ON/OFF operation can be changed directly by pressing the increment key (UP) and the decrement key (DOWN). This forces the pressure value display to be reset to zero when the pressure port is open on the atmospheric pressure side. Stops key operations from being accepted. Displays the peak value and bottom value for fluctuating pressure. The peak value appears in the main display, and the bottom value appears in the sub display. Description Sets the output mode for comparative output. Sets the output mode for comparative output. Allows switching between analog voltage output / analog current output, and auto-reference input / remote zero-adjust-ment input. Sets normally open (NO) or normally closed (NC). Sets the response time. The response time can be selected from.5 ms, 5 ms, ms, 5 ms, 5 ms, ms, 5 ms, 5 ms,, ms and 5, ms. mm.55 in spanner Note: Do not tighten the pressure port by holding the product with the spanner. It may cause the product breakage. Display color switching for main display Unit switching Allows the color for the main display to be changed. The colors can be set to red / green or green / red to correspond to ON/OFF output, or it can be fixed at red or green all the time. Pressure unit can be changed.

Dual Display Digital Pressure Sensor SERIES Ver. 76 PRECAUTIONS FOR PROPER Refer to p.566 for general precautions. PRO mode If the mode selection key is pressed and held for 5 seconds in RUN mode, the mode will switch to PRO mode. If the mode selection key is pressed while a setting is being made, the mode will switch to RUN mode. In this case, the settings that have been changed will be entered. Setting item Sub display switching Display refresh rate switching Hysteresis fix value switching Linked display color switching (standard type only) ECO mode setting Setting check code Setting copy mode Reset setting Description Changes the information in the sub display during RUN mode operation to the desired alphanumeric display. Changes the display refresh rate for the pressure value displayed in the main display. Sets the hysteresis for EASY mode and window comparator mode. (8 steps) Allows the display color for the main display to be switched in line with the output operation for comparative output or comparative output. Allows power consumption to be reduced by dimming the display or turning it off. Allows the setting details to be checked via codes. Allows the setting details for the master sensor to be copied to slave sensors. Resets the settings to the factory settings. DIMENSIONS (Unit: mm in) DP- (-P).5.67 5.5 7.5 9.5..95.7 Table of codes Code Code.787 Comparative output NO/NC output mode switching EASY Hysteresis st digit Window comparator Response time Unit switching Display refresh rate ECO mode.5 ms MPa 5 ms OFF 5 ms kpa 5 ms STD ms kgf/cm, ms FULL 5 ms bar 5 ms psi ms mmhg 5 ms inchhg 5 ms, ms 5, ms nd digit th digit Standard type Multi-function rd digit type Standard type only Comparative output NO/NC Analog voltage output / Threshold Display color for Display output mode switching External input value display main display color linking NO OFF OFF Analog voltage Comparative P-, Lo- output Red output Auto- when ON Comparative NC NO reference Hi- output EASY Remote Comparative NO NC zero-adjustment P-, Lo- Green output Analog current when ON Comparative NC NO Hi- output output Hysteresis NO NC Comparative ADJ. Always output NC red Comparative NO Window output comparator NC Comparative Always output green Comparative output 5th digit 6th digit 7th digit 8th digit Connector The CAD data can be downloaded from the website. Europe.9.76 7 Sensor.5.59 R (PT) /8 male thread (North America: NPT /8).787.7 M female thread,.57 deep G /8 male thread.55 DP- -M(-P) 5.5..5.77.787 Sensor ø8. ø.7.787 connector.5.59 M female thread,.57 deep,.57 deep DP- -E-P-J Sensor 7.5 5.5.87. 7.76.787 M8 connector.5.59 9.5.7.5.77 5 G /8 male thread.59 7.76.787.55 M female thread,.57 deep

77 Dual Display Digital Pressure Sensor SERIES Ver. DIMENSIONS (Unit: mm in) The CAD data can be downloaded from the website. MS-DP-.5.57 9.5.7.787 t t.79.787..65 R R.5 Assembly dimensions Mounting drawing with DP- (-P).866.787.5 ø. ø.9.9 -R. R.8 -ø.5 ø.8 5..9 5.5.7.7 Material: Cold rolled carbon steel (SPCC) (Trivalent uni-chrome plated) Two M (length 6 mm.6 in) screws with washers are attached. MS-DP-5.75.896.5.77.787 9.5.6.787.5.5.787 Material: Stainless steel (SUS) Two M (length 6 mm.6 in) screws with washers are attached. MS-DP- MS-DP- ø.5 ø.77 8.5.5.5.75 -ø.5 ø.8 8. t.5 t.59 Sensor mounting bracket (Optional) Assembly dimensions Mounting drawing with DP- (-P) 5.77 9.5.866 -R. R.8 9.5.7..65.5.57 5.5. 5.77 5.59 Assembly dimensions.99 ø.5 ø.77.787 9.5.6 9.5.787 8.5.99..5.77 Panel cut-out dimensions When unit is installed...6 7.5.95.5.67.5.59 Mounting drawing with DP- -M(-P) R6.75 R.66 6.6.5.77.5.59 8. 5.5.6 9.5.7 t t.79 ø8. ø.7 t.5 t.59.7 Sensor mounting bracket (Optional) Panel mounting bracket (Optional), Front protection cover (Optional).5.58.787 9..57.5.58 5.969..5 7..8. Front protection cover 8.7. 8..7 (Note ) 7.5.95 9.5.7 (Note ).7 R /8 male thread (Note ) Panel thickness dimension to 6 mm.9 to.6 in When n units are installed horizontally in series 55.65 or more. Xn +.5.8 X (n-)...6...6 When n units are installed vertically in series...6. Xn +.5.8 X (n-)..5 Connector,.57 deep M female thread, (5.7 max).57 deep View A Material: Polyacetal (Panel mounting bracket) Polycarbonate (Front protection cover) Note: The panel thickness should be to 6 mm.9 to.6 in. 55.65 or more Note: The panel thickness should be to 6 mm.9 to.6 in. Notes: ) DP- -E-P has a G/8 male thread. DP- -N(-P)has a NPT/8 male thread. ) In case of DP- -E-P, the dimension 7.5 become to be, the dimension 9.5 become to be 7 and the dimension become to be.

Dual Display Digital Pressure Sensor SERIES Ver. 78 DIMENSIONS (Unit: mm in) The CAD data can be downloaded from the website. MS-DP- Assembly dimensions Mounting drawing with DP- (-P).575.7.68.575 9.7 (.8).7.68 Front protection cover (DPX-) Panel thickness dimension to. mm.9 to.6 in 8.5 6.7 6.5. 6.5.56.8 R /8 male thread (Note ) Panel mounting bracket body Panel mounting bracket Panel mounting bracket (Replacement from conventional model) (Optional).7 Connector M5 female thread Spacer Material: Nylon 6 (Panel mounting bracket body) Stainless steel (SUS) (Panel mounting bracket) Cold rolled carbon steel (SPCC) (Trivalent uni-chrome plated) (Spacer) Notes: ) DP- -E-P has a G/8 male thread. DP- -N(-P)has a NPT/8 male thread. ) The panel tickness should be to mm.9 to.6 in. Panel cut-out dimensions MS-DP-FM Flat attachment (Optional) MS-DP-FR/FN/FE Flat attachment (Optional) Assembly dimensions Mounting drawing with DP- -M(-P).5.75 -ø. ø.69.5.75.95.787.95.95 6.5.56 5.5.7 8.5.5 7.57.5.5. 7.5.689 Material: Polybutylene terephthalate (PBT) (Glass fiber reinforced) (Enclosure) Stainless steel (SUS) (Pressure port) Hydrogenated Nitrile Butadiene Rubber (H-NBR) (O-ring) Weight: 5 g approx. (flat attachment only) Two M (length 8 mm.5 in) screws, two M (length mm.787 in) screws are attached. 8.5 56.5 Assembly dimensions Mounting drawing with DP- -M(-P) 5.5.67 -ø. ø.69 Pressure port G /8 female thread (Note).55.787.95 5.5.67 (.95).95 6.5.56 5.5.7.5.5 Product distinguishing mark MS-DP-FR: line MS-DP-FN: line MS-DP-FE: line 6.7 Note: MS-DP-FR has a Rc/8 female thread. MS-DP-FN has a NPT/8 female thread. +.5 +. 6.7 +.5 +. 7.57.5.5 7.5.689. 8.5.5 Material: Polybutylene terephthalate (PBT) (Glass fiber reinforced) (Enclosure) Stainless steel (SUS) (Pressure port) Hydrogenated Nitrile Butadiene Rubber (H-NBR) (O-ring) Weight: 5 g approx. (flat attachment only) Two M (length 8 mm.5 in) screws, two M (length mm.787 in) screws are attached. MS-DP-7 Conversion bushing (Optional) CN-A(-R)-C Connector attached cable (Optional, CN-A-C is attached to the sensor) 5.8.6 5 5 (.78) (.969) 8 (.5) 8 L.5.5.8.5 (. ) 7.8.7.55 M5 male thread Gasket Length L ø.7 ø.6 cable..9 8.5 Rc /8 female thread Material: Brass (Nickel plated) Weight: g approx. Model No. Length L (mm in) CN-A(-R)-C, 9.7 CN-A(-R)-C, 78.7 CN-A(-R)-C, 8. CN-A(-R)-C5 5, 96.85