ATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase

Similar documents
ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

ATV32HU75N4 variable speed drive ATV kw V - 3 phase - with heat sink

ATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase - with heat sink

ATV32H055N4 variable speed drive ATV kw V - 3 phase - with heat sink

ATV32HD11N4 variable speed drive ATV32-11 kw V - 3 phase - with heat sink

ATV32HD11N4 variable speed drive ATV32-11 kw V - 3 phase - with heat sink

ATV32H075M2 variable speed drive ATV32-0,75 kw V - 1 phase - with heat sink

ATV32HU40N4 variable speed drive ATV32-4 kw V - 3 phase - with heat sink

ATV32H018M2 variable speed drive ATV32-0,18 kw V - 1 phase - with heat sink

ATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase - with heat sink

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

ATV320U06N4C variable speed drive ATV kW V - 3 phase - compact

ATV320U07M2C variable speed drive ATV kW V - 1 phase - compact

ATV320U30N4B variable speed drive ATV320-3kW V - 3 phase - book

ATV320D11N4B variable speed drive ATV320-11kW V - 3 phase - book

ATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book

ATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

ATV61HC31Y variable speed drive ATV61-310kW - 690V - without EMC filter

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

ATV61HC11N4 SPEED DRIVE 150 HP 460 V ATV61

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

ATV61HU55M3 ATV61 5,5 kw 7,5HP 240V single phase EMC IP20

ATV71QC16N4 variable speed drive ATV71Q - 160kW / 250HP V - IP20

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

ATV650U30N4E variable speed drive ATV650-3kW V - IP55 - disconnect switch

ATV61QC31N4 variable speed drive ATV61Q - 315kW / 500HP V - IP20

ATV930D22M3 variable speed drive - ATV930-22kW - 200/240V- with braking unit - IP21

ATV630U15N4 variable speed drive ATV kW/2HP V - IP21/UL type 1

ATV340D75N4E variable speed drive - 75kW- 400V - 3 phases - ATV340 Ethernet

ATV340D18N4E variable speed drive - 18kW- 400V - 3 phases - ATV340 Ethernet

ATV61HC31N4 variable speed drive ATV61-315kW 500HP - 500V - EMC filter - IP20

ATV630D11N4 variable speed drive ATV630-11kW/15HP V - IP21/UL type 1

ATV320D15M3C variable speed drive ATV320-15kW - 200V - 3phase - compact

ATV212WD30N4 variable speed drive ATV212-30kW - 40hp - 480V - 3ph - EMC class C2 - IP55

ATV212WU40N4 variable speed drive ATV212-4kW - 5hp - 480V - 3ph - EMC class C2 - IP55

ATV71EXA2C71N4 enclosed variable speed drive ATV71 Plus kw - 400V - IP23

ATV212WU55N4 variable speed drive ATV kW - 7.5hp - 480V - 3ph - EMC class C2 - IP55

ATV32HU15N4 variable speed drive ATV kw V - 3 phase - with heat sink

ATV61HC22N4 Altivar 61 drive 350hp 400/480 3ph

ATV32H037N4 variable speed drive ATV kw V - 3 phase - with heat sink

ATV32HD11N4 variable speed drive ATV32-11 kw V - 3 phase - with heat sink

ATV320D11N4B. Product datasheet Characteristics. Main. Complementary 1 / 8. Device short name Format of the drive

ATV630D90N4 variable speed drive ATV630-90kW/125HP V - IP21/UL type 1

ATV320U15N4C. Product datasheet Characteristics. Main. Complementary 1 / 7. Device short name Format of the drive

ATV320U11N4C. Product datasheet Characteristics. Main. Complementary 1 / 7. Device short name Format of the drive

ATV320U22M2C. Product datasheet Characteristics. Main. Complementary 1 / 7. Device short name Format of the drive

ATV212HD18N4 variable speed drive ATV kW - 25hp - 480V - 3ph - EMC - IP21

ATV212HD11N4 variable speed drive ATV212-11kW - 15hp - 480V - 3ph - EMC - IP21

ATV212HD15N4 variable speed drive ATV212-15kW - 20hp - 480V - 3ph - EMC - IP21

ATV930U07M3 variable speed drive - ATV930-0,75kW - 200/240V- with braking unit - IP21

ATV630D15N4 variable speed drive ATV630-15kW/20HP V - IP21/UL type 1

ATV650D22N4 variable speed drive ATV650-22kW/30HP V - IP55

ATV320U06N4C variable speed drive ATV kW V - 3 phase - compact

ATV212HU55N4 variable speed drive ATV kW - 7.5hp - 480V - 3ph - EMC - IP21

ATV212HU55N4 variable speed drive ATV kW - 7.5hp - 480V - 3ph - EMC - IP21

ATV340U15N4 variable speed drive - 1.5kW- 400V - 3 phases - ATV340

ATV61HD11Y variable speed drive ATV61-11kW / 690V - 10HP / 575V - IP20

ATV660C16Q4X1 Compact Drive System ATV /132kW V - IP23

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)

ATV630U15N4 variable speed drive ATV kW/2HP V - IP21/UL type 1

ATS01N232RT soft starter for asynchronous motor - ATS01-32 A V

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATV212HD15N4 variable speed drive ATV212-15kW - 20hp - 480V - 3ph - EMC - IP21

ATV630D30N4 variable speed drive ATV630-30kW/40HP V - IP21/UL type 1

ATV212HD75N4. Main. Range of product Altivar 212. Device short name. Motor power hp 160 A 460 V khz with derating factor

ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)

ATV680C45Q4X1 Low Harmonic Drive System ATV /355kW V - IP23

ATV930D45N4 variable speed drive - ATV930-45kW - 400/480V - with braking unit - IP21

ATV212HD30N4 variable speed drive ATV212-30kW - 40hp - 480V - 3ph - EMC - IP21

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h

ATS22C17Q. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATV930U55N4 variable speed drive - ATV930-5,5kW - 400/480V - with braking unit - IP21

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

ATV650C13N4F. ATV650C13N4F variable speed drive ATV kW V - IP54 - disconnect switch. Product data sheet Characteristics.

ATS22D47S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATV61WD18N4C variable speed drive ATV kW 25HP V - EMC filter - IP54

ATV650C16N4F variable speed drive ATV kW V - IP54 - disconnect switch

ATV212HU15N4. Main. Range of product Altivar 212. Device short name 3.7 A 460 V khz adjustable

ATV71HC31N4 variable speed drive ATV71-315kW-500HP - 480V - EMC filter-graphic terminal

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

ATS22C41Q soft starter-ats22-control 220V-power 230V(110kW)/ V(220kW)

ATV71HC40N4 variable speed drive ATV71-400kW-600HP - 480V - EMC filter-graphic terminal

ATV630C22N4 variable speed drive ATV kW/350HP V - IP00

600 hp at V 3 phases. 568 A for 480 V 3 phases 400 kw / 600 hp 637 A for 380 V 3 phases 355 kw 709 A for 380 V 3 phases 400 kw / 600 hp

ATV212HD11M3X variable speed drive ATV212-11kW - 15hp - 240V - 3ph -wo EMC - IP21

ATV630U55N4 variable speed drive ATV kW/7.5HP V - IP21/UL type 1

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

ATV71HC50Y variable speed drive ATV71-500kW - 690V

ATV71HC11Y variable speed drive ATV71-110kW - 690V - EMC filter-graphic terminal

250 kw at V 3 phases. 400 hp at V 3 phases

ATV71HC28N4D variable speed drive ATV71-280kW-450HP - 480V - EMC filter-graphic terminal

ATV71HC40N4 variable speed drive ATV71-400kW-600HP - 480V - EMC filter-graphic terminal

ATV61HU30N4 SPEED DRIVE, 4HP,460V,ATV61

Transcription:

Product datasheet Characteristics ATV32HU30N4 variable speed drive ATV32-3 kw - 400 V - 3 phase - with heat sink Complementary Line current Apparent power Prospective line Isc Nominal output current Maximum transient current Output frequency Nominal switching frequency Switching frequency Speed range Speed accuracy Main Range of product Altivar 32 Product or component type Product destination Product specific application Function available - Assembly style Component name EMC filter Network number of phases Variable speed drive Asynchronous motors Synchronous motors Complex machines With heat sink ATV32 Class C2 EMC filter integrated 3 phases [Us] rated supply voltage 380...500 V - 15...10 % Supply voltage limits 323...550 V Supply frequency 50...60 Hz - 5...5 % Network frequency Motor power kw 11.1 A 380 V 3 phases 3 kw 8.4 A 500 V 3 phases 3 kw 7.3 kva 500 V 3 phases 3 kw <= 5 ka 3 phases 7.1 A 4 khz 500 V 3 kw 10.7 A 60 s 3 kw 0.0005...0.599 khz 4 khz Torque accuracy +/- 15 % 2...16 khz adjustable Transient overtorque 170...200 % Braking torque Asynchronous motor control profile Synchronous motor control profile Regulation loop Motor slip compensation Local signalling Output voltage Noise level Insulation Electrical connection 47.5...63 Hz 3 kw 380...480 V 1...100 asynchronous motor in open-loop mode +/- 10 % of nominal slip 0.2 Tn to Tn <= 170 % with braking resistor Voltage/frequency ratio, 2 points Voltage/frequency ratio, 5 points Flux vector control without sensor - Energy Saving, NoLoad law Flux vector control without sensor, standard Voltage/frequency ratio - Energy Saving, quadratic U/f Vector control without sensor Adjustable PID regulator Automatic whatever the load Not available in voltage/frequency ratio (2 or 5 points) Adjustable 0...300 % 1 LED red drive voltage 1 LED green CANopen run 1 LED red CANopen error 1 LED red drive fault <= power supply voltage 45 db 86/188/EEC Electrical between power and control Screw terminal 0.5...1.5 mm² AWG 18...AWG 14 control The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. 1 / 8

Tightening torque Removable screw terminals 1.5...2.5 mm² AWG 14...AWG 12 motor/braking resistor Screw terminal 1.5...4 mm² AWG 14...AWG 10 power supply 0.5 N.m 4.4 lb/ft control 0.7 N.m 7.1 lb/ft motor/braking resistor 0.6 N.m 5.3 lb/ft power supply Supply Internal supply for reference potentiometer (1 to 10 kohm) 10.5 V DC +/- 5 % <= 10 ma overload and short-circuit protection Analogue input number 3 Analogue input type Sampling duration Response time Voltage AI1 0...10 V DC 30000 Ohm 10 bits Bipolar differential voltage AI2 +/- 10 V DC 30000 Ohm 10 bits Current AI3 0...20 ma (or 4-20 ma, x-20 ma, 20-x ma or other patterns by configuration) 250 Ohm 10 bits 2 ms AI1, AI2, AI3 analog 2 ms AO1 analog 8 ms +/- 0.7 ms LI1...LI6 logic 2 ms R1A, R1B, R1C relay 2 ms R2A, R2C relay Accuracy +/- 0.2 % AI1, AI2, AI3 for a temperature of -10...60 C +/- 0.5 % AI1, AI2, AI3 for a temperature of 25 C +/- 1 % AO1 for a temperature of 25 C +/- 2 % AO1 for a temperature of -10...60 C Linearity error Analogue output number 1 Analogue output type Discrete output number 3 Discrete output type Minimum switching current Maximum switching current Discrete input number 7 Discrete input type Discrete input logic Acceleration and deceleration ramps Braking to standstill Protection type Communication port protocol Connector type Physical interface Transmission frame Type of polarization Number of addresses Method of access +/- 0.2...0.5 % of maximum value AI1, AI2, AI3 +/- 0.3 % AO1 Software-configurable current AO1 0...20 ma 800 Ohm 10 bits Software-configurable voltage AO1 0...10 V 470 Ohm 10 bits Configurable relay logic R1A, R1B, R1C NO/NC 100000 cycles Configurable relay logic R2A, R2B NO 100000 cycles Logic LO 5 ma 24 V DC configurable relay logic 3 A 250 V AC resistive (cos phi = 1 R1 4 A 30 V DC resistive (cos phi = 1 R1 2 A 250 V AC inductive (cos phi = 0.4 R1, R2 2 A 30 V DC inductive (cos phi = 0.4 R1, R2 5 A 250 V AC resistive (cos phi = 1 R2 5 A 30 V DC resistive (cos phi = 1 R2 Programmable (sink/source) LI1...LI4 24...30 V DC level 1 PLC Programmable as pulse input 20 kpps LI5 24...30 V DC level 1 PLC Switch-configurable PTC probe LI6 24...30 V DC Safe torque off STO 24...30 V DC 1500 Ohm Positive logic (source) LI1...LI6 < 5 V > 11 V Negative logic (sink) LI1...LI6 > 19 V < 13 V S U CUS Deceleration ramp automatic stop DC injection Deceleration ramp adaptation Linear Ramp switching By DC injection Input phase breaks drive Overcurrent between output phases and earth drive Overheating protection drive Short-circuit between motor phases drive Thermal protection drive CANopen Modbus 1 RJ45 Modbus/CANopen on front face 2-wire RS 485 Modbus RTU Modbus No impedance Modbus 1...247 Modbus 1...127 CANopen Slave CANopen Electromagnetic compatibility 1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5 2 / 8

Width Height Depth Product weight Option card Functionality Specific application Electrical fast transient/burst immunity test level 4 IEC 61000-4-4 Electrostatic discharge immunity test level 3 IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 Conducted radio-frequency immunity test level 3 IEC 61000-4-6 Voltage dips and interruptions immunity test IEC 61000-4-11 60 mm 325 mm 245 mm 3 kg Communication card CANopen daisy chain Communication card CANopen open style Communication card DeviceNet Communication card Ethernet/IP Communication card Profibus DP V1 Mid Other applications Environment standards EN 55011 class A group 1 EN 61800-3 environments 1 category C2 EN 61800-3 environments 2 category C2 EN/IEC 61800-3 EN/IEC 61800-5-1 product certifications marking CSA C-Tick GOST NOM 117 UL pollution degree 2 EN/IEC 61800-5-1 IP degree of protection IP20 EN/IEC 61800-5-1 vibration resistance 1 gn 13...200 Hz EN/IEC 60068-2-6 1.5 mm peak to peak 3...13 Hz EN/IEC 60068-2-6 shock resistance 15 gn 11 ms EN/IEC 60068-2-27 relative humidity 5...95 % without condensation IEC 60068-2-3 5...95 % without dripping water IEC 60068-2-3 ambient air temperature for operation ambient air temperature for storage -25...70 C operating altitude operating position CE -10...50 C without derating 50...60 C with derating factor <= 1000 m without derating 1000...3000 m with current derating 1 % per 100 m Vertical +/- 10 degree Offer Sustainability Sustainable offer status RoHS (date code: YYWW) REACh Product environmental profile Product end of life instructions Green Premium product Compliant - since 1007 - Schneider Electric declaration of conformity Reference not containing SVHC above the threshold Available Available Contractual warranty Warranty period 18 months Size B Dimensions 3 / 8

Mounting and Clearance (1) Minimum value corresponding to thermal constraints. A 150 mm clearance may help to connect the ground. (2) Optional GV2 circuit-breaker Option: Protection Device, GV2 circuit-breaker The drive is prepared to be equipped with an optional GV2 circuit-breaker. The GV2 circuit-breaker is directly mounted on the drive. Mechanical and electrical link are made using the optional adapter. The options are supplied with detailed mounting instruction sheet. NOTE: The product overall dimension, including GV2 adapter and EMC plate mounted, becomes 424 mm (16.7 in.) 4 / 8

(1) Ground screw (HS type 2-5x12) Connection Diagrams Single or Three-phase Power Supply - Diagram with Line Contactor Connection diagrams conforming to standards EN 954-1 category 1 and IEC/EN 61508 capacity SIL1, stopping category 0 in accordance with standard IEC/EN 60204-1. (1) Line choke (if used) (3) Fault relay contacts, for remote signaling of drive status Single or Three-phase Power Supply - Diagram with Switch Disconnect Connection diagrams conforming to standards EN 954-1 category 1 and IEC/EN 61508 capacity SIL1, stopping category 0 in accordance with standard IEC/EN 60204-1. (1) Line choke (if used) (3) Fault relay contacts, for remote signaling of drive status Diagram with Preventa Safety Module (Safe Torque Off Function) Connection diagrams conforming to standards EN 954-1 category 3 and IEC/EN 61508 capacity SIL2, stopping category 0 in accordance with standard IEC/EN 60204-1. When the emergency stop is activated, the drive power supply is cut immediately and the motor stops in freewheel, according to category 0 of standard IEC/EN 60204-1. A contact on the Preventa XPS AC module must be inserted in the brake control circuit to engage it safely when the STO (Safe Torque Off) safety function is activated. 5 / 8

(1) Line choke (if used) (2) It is essential to connect the shielding to the ground. (3) Fault relay contacts, for remote signaling of drive status The STO safety function integrated into the product can be used to implement an "EMERGENCY STOP" (IEC 60204-1) for category 0 stops. With an additional, approved EMERGENCY STOP module, it is also possible to implement category 1 stops. STO function The STO safety function is triggered via 2 redundant inputs. The circuits of the two inputs must be separate so that there are always two channels. The switching process must be simultaneous for both inputs (offset < 1 s). The power stage is disabled and an error message is generated. The motor can no longer generate torque and coasts down without braking. A restart is possible after resetting the error message with a "Fault Reset". The power stage is disabled and an error message is generated if only one of the two inputs is switched off or if the time offset is too great. This error message can only be reset by switching off the product. Diagram without Preventa Safety Module Connection diagrams conforming to standards EN 954-1 category 2 and IEC/EN 61508 capacity SIL1, stopping category 0 in accordance with standard IEC/EN 60204-1. The connection diagram below is suitable for use with machines with a short freewheel stop time (machines with low inertia or high resistive torque). When the emergency stop is activated, the drive power supply is cut immediately and the motor stops in freewheel, according to category 0 of standard IEC/EN 60204-1. (1) Line choke (if used) (2) It is essential to connect the shielding to the ground. (3) Fault relay contacts, for remote signaling of drive status The STO safety function integrated into the product can be used to implement an "EMERGENCY STOP" (IEC 60204-1) for category 0 stops. Control Connection Diagram in Source Mode 6 / 8

(1) Reference potentiometer SZ1RV1202 (2.2 kω) or similar (10 kω maximum) Derating Curves Derating curve for the nominal drive current (In) as a function of temperature and switching frequency. X Switching frequency Above 4 khz, the drive will reduce the switching frequency automatically in the event of an excessive temperature rise. Sink / Source Switch Configuration (SW1) The logic input switch (SW1) is used to adapt the operation of the logic inputs to the technology of the programmable controller outputs. Switch SW1 set to Source position Switch SW1 set to Source position and use of an external power supply for the LIs Switch SW1 set to Sink Int position Switch SW1 set to Sink Ext position 7 / 8

8 / 8