PN DN FIG. 660D-BATT+670D-BATT 661D-BATT+670D-BATT SISTEMI DI MISURA / SYSTEM MEASURE / SYSTEMES DE KAT KAT-06...

Similar documents
SITRANS F M MAG 8000 SITRANS F. Answers for industry. Precise metering with battery powered water meters.

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/221

CONVERTER MC406. Electromagnetic flowmeter. The battery powered electronic converter DS400-1-USA

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

CONVERTER MC608 A/B/R/P/I. The Hybrid electronic converter for all applications DS300-1-USA

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F C

SITRANS F US Inline. SITRANS FUE950 energy calculator 4/269

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline

SITRANS F flowmeters SITRANS F US. SITRANS FUE950 energy calculator. 4/240 Siemens FI

Flow Measurement SITRANS F M

AG3000 SERIES FLANGED MAGMETER

SITRANS F C. Transmitter MASS 6000 Ex d compact/remote 3/195

Flow Measurement SITRANS F M. Transmitter MAG 5000/ /34 Siemens FI Overview

AG3000 SERIES FLANGED MAGMETER

( F L O W I Z F A M I L Y )

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

imag 4700 Series FLANGED MAGMETER

imag 4700 Series FLANGED MAGMETER

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )

Flow Measurement SITRANS F M

Induction Flow Meter. AcquaMAG. Installation and Operating Manual

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

Flow Measurement SITRANS F C

imag-series Flanged Magmeter

SITRANS F flowmeters SITRANS F US

EC 600 Electronic Volume Corrector

DATASHEET ULTRASONIC COMPACT ENERGY METER MODEL 773

Flow Measurement SITRANS F US Clamp-on

WaterMaster Select Electromagnetic flowmeter. The perfect fit for water industry applications

Ultrasonic Flow Meter Brochure

SONOMETER TM 500 Ultrasonic compact energy meter

Electro-Magnetic Flowmeters Converters

Flow Measurement SITRANS F M. Transmitter MAG 5000/6000 4/33. Overview

SENSOR MUT2200EL. Electromagnetic flowmeter. The electromagnetic flowmeter for all applications DS100-1-USA

DRAFT. Customer site gravity factor. Filtering parameters. Five points for linearity correction to ensure maximum accuracy

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter

SITRANS F flowmeters SITRANS F US. Flowmeter SONO 3300/FUS060 4/177. Technical specifications. Overview

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

accurate measurement of compressed air consumption and leakage detection Calibration certificates and continous calibration, OEKD calibration service

MMT330 Series Moisture and Temperature Transmitters for Oil

KATflow 200 Hand-Held Clamp-On Ultrasonic Flowmeter

Flow Measurement SITRANS F C

Thermal Mass Flowmeter Sensyflow FMT200-D

Panel Indicators. NEW 4~20mA Panel Display. Process Indicators INTECH INSTRUMENTS.

SITRANS T measuring instruments for temperature

Flow Measurement SITRANS F US Clamp-on

UW Purchase Specification Section Central Cooling Water Meter Page 1 of 6

Ultrasonic Heat Flow Meters

EE771 Series. Flowmeter for compressed air and gases in Industrial Applications. EE771 Compact. EE771 remote probe

Neon pr. ph/ ORP measurement. Applications. Description

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

EW773 Series Ultrasonic Hydronic Meters FOR HEATING AND COOLING APPLICATIONS

DCT7088 Portable Digital Correlation Transit Time Flowmeter

Level sensor Stainless steel version Model RLT-1000, for industrial applications

THE TECHNOLOGY BEHIND THE MEASUREMENT

MAG. ECO FLO imag Series NSF FEATURES

Weighing Indicator. Features. Description. Applications

Series DMHF Heat Meter

SYSTEM COMPONENTS SYSTEM COMPONENTS MODULES

InCos-P Pressure sensor 20 Pa Pa

Flow measurement in open channel. Portable Area-Velocity Mainstream EH7000 P. Ultrasonic Area-Velocity Flow meter MAINSTREAM 7000

CALEC energy master The benchmark in energy measurement

SITRANS F flowmeters. SITRANS F C Transmitter MASS 6000 for 19" insert/19" wall mounting. 4/134 Siemens FI

MID approval no. DE-08-MI004-PTB004 Date of release

Flow VA 500/

2 CLASS AMR READY INVONIC H DATA APPLICATION HEAT METERING. approved ULTRASOUND HEAT AND COOLING METERS DN15, DN20, DN25, DN40, DN50

... f l o w measurement & control...

DMT345 and DMT346 Dewpoint Transmitters

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310

ISOMAG HIGH PERFORMANCE CONVERTER THE FRIENDLY MAG METER GRAPHIC DISPLAY CONVERTER

Flow. Order number VA 550. Order no. VA 570. Further accessories A_...M_

FEATURES Easy setup Minimal straight pipe Mounted or remote rate & total Tamper-evident seal NSF-61 approved IP68 rated

C-Flow Coriolis Mass Flow Meter

Technical specification FLUXUS F501. Ultrasonic measurement of water flow

SonoSelect and SonoSafe energy meters

NFC110. Flow Computer For Low Pulses FEATURES

SITRANS L Level instruments

Flow Measurement SITRANS F US Clamp-on

FEATURES Easy setup Minimal straight pipe Mounted or remote rate & total Tamper-evident seal NSF-61 approved IP68 rated

Continuous level measuring system NB 3000 Selection list

RHE27. Rack/Panel Mount Multifunction Coriolis Flow Transmitter

Aysix 200 Hand-Held Flow Meter

PTU300 Combined Pressure, Humidity and Temperature Transmitter

RHE28. Field and Wall Mount Multifunction Coriolis Flow Transmitter

B.M LIMENA (PD)

Minilog RDL10. Technical Information. Measured value collector with 2 input channels for storing analog and digital values

Absolute Encoders Multiturn

Easy Flow Indicator Magnetisch-Induktiver Durchflussmesser. Type 8024 For Insertion Fittings. Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI

Wall-/Pipe Mounted Universal Process Indicator

User guide. SonoMeter 30. Ultrasonic energy meter for heating and cooling applications. Danfoss VUIGI102 1

SITRANS F flowmeters SITRANS F US. SITRANS FUS1010 Standard clamp-on. 4/270 Siemens FI Overview

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

Level Measurement Continuous level measurement - Ultrasonic transmitters

Level gauges Series LS Level indicator, switch and transmitter for liquids

Technical specification FLUXUS F501IP. Non-invasive ultrasonic flow measurement on buried pipes. Features. Applications

Transcription:

1 2 BATTERY-OPERATED WATER METER MAG 8000 MAG 8000 is a comprehensive meter which intelligent information and high performance measurement as well as the easy to install concept take cost of ownership and customer service to a new level for water meter. 3 4 5 BENEFITS Easy to install Compact or remote solution with factory mounted cable and customer setting from factory IP68/NEMA 6P enclosure. Sensor can be buried Flexible power supply - internal or external battery pack or mains power supply with battery back-up possibilities Superior measurement Down to 0.2 % maximum uncertainty OIML R 49 type approval PTB K7.2 FM Fire Service Approval Bi-directional measurement 6 Long lasting performance/low cost of Ownership Verification according to Directive 2014/32/EU of the European Parliament and Council of 26 February, 2014 on measuring instruments, Annex VI Thermal Energy Meters (MI-004) No moving parts means less wear and tear Up to 6 to 10 years maintenance-free operation in typical revenue application Robust construction built for the application Intelligent information, easy to access Advanced information on site Data logger Advanced statistics and diagnostics Add-on communication modules APPLICATIONS The following MAG 8000 versions are available as stand-alone water meters: MAG 8000 (7ME6810) for abstraction and distribution network MAG 8000 CT (7ME6820) for revenue and bulk metering MAG 8000 (7ME6880) for irrigation DESIGN MAG 8000 is designed to minimize power consumption. The product program consists of Basic and advanced version Sensor sizes from DN 25 to 1200 (1 to 48 ) Compact and remote installation in IP68/NEMA 6P enclosure and factory-mounted cable SIMATIC PDM and Flow Tool PC configuration softwares Add-on communication module (left), PC-IrDA connection (right) 6-11 k06c-f660d-batt-std-1_rev11-2016

FUNCTION - BATTERY-OPERATED WATER METER MAG 8000 MAG 8000 is a microprocessor-based water meter with graphical display and key for optimum customer operation and information on site. The transmitter drives the magnetic field in the sensor, evaluates the flow signal from the sensor and calculates the volume passing through. It delivers the required information via the integrated pulse output or communication interfaces as part of a system solution. Its intelligent functionality, information and diagnostics ensure optimum meter performance and information to optimize water supply and billing. The SIMATIC PDM tool gives the possibility of testing and verifying the flowmeter on site and creating a printed Qualification Certificate with all specific data that define the quality status of the measurement. The Qualification Certificate consists of two pages with information about the actual status of the sensor: Part 1 provides general settings, sensor and battery info, totalizer values and pulse output settings. Part 2 provides detailed information about electronic and sensor functionality and a main parameter list for evaluating the functionality of the MAG 8000 water meter. MAG 8000 can be ordered as a Basic or an Advanced version. Features / Version Measuring frequency in battery power mode (Manually selected) 1) Output MAG 8000 MAG 8000 Basic/ MAG 8000 Irrigation AG 8000 Advanced 1/15, 1/30 or 1/60 Hz from 6.25 to 1/60 Hz depending of sensor size 2 FW/RV/Al/CA (max. 50 Hz pulse rate) 2 FW/RV/Al/CA (max. 100 Hz pulse rate) Communication Add-on Add-on Data logger No Yes Insulation test No Yes Leakage detection No Yes Meter utilization No Yes Statistics No Yes Tariff No Yes Settle date (Revenue) No Yes 1) Excitation frequency settings with mains power supply, see technical specifications for each version Some information is accessible via the display whereas all information is accessible via the IrDA communication interface with the PDM software. Data and parameters are registered in a EEPROM. They can all be read, but changing the information demands a software password or a hardware key attached to the printed circuit board. 6-12 k06c-f660d-batt-std-2_rev11-2016

TECHNICAL SPECIFICATIONS - BATTERY-OPERATED WATER METER MAG 8000 TRANSMITTER 1 Installation Enclosure Cable entries Display Resolution Flow unit Europe US Australia Digital output Output A function Output B function Output Communication Add-on modules Power supply Internal battery pack External battery pack Mains power supply Cable Compact (integral) Remote with factory-mounted cable 5, 10, 20 or 30 m (16.4, 32.8, 65.6 or 98.4 ft) Stainless steel top housing (AISI 316) and coated brass bottom. Remote wall mount bracket in stainless steel (AISI 304). 2 x M20 (one gland for one cable of size 6 8 mm (0.02... 0.026 ft) is included in the standard delivery) Display with 8 digits for main information. Index, menu and status symbols for dedicated information Totalized information can be displayed with 1, 2 or 3 decimals or automatic adjustment (default) Volume in m3 and flow rate in m3/h Volume in Gallon and flow rate in GPM Volume in Ml and flow rate as Ml/d 2 passive outputs (MOS), individual galvanically isolated Maximum load ± 35 V DC, 50 ma short circuit protected Programmable as pulse volume forward reverse forward/net reverse/net Programmable as pulse volume (like output A), alarm Max. pulse rate of 50 Hz (only Basic version) and 100 Hz, pulse width of 5, 10, 50, 100, 500 ms IrDA: Standard integrated infrared communication interface with Modbus RTU protocol RS 232 serial interface with Modbus RTU (Rx/Tx/GND), point to point with max. 15 m cable RS 485 serial interface with Modbus RTU (+/-/GND), multidrop with up to 32 devices with max. 1000 m cable Encoder interface module (for Itron 200WP) Sensus protocol GSM/GPRS module with or without analog input cable Auto detection of power source with display symbol for operation power. 1 D-Cell 3.6 V/16.5 Ah 2 D-Cell 3.6 V/33 Ah 4 D-Cell 3.6 V/66 Ah 12... 24 V AC/DC (10 32 V) 2 VA 115... 230 V AC (85 264 V) 2 VA Both mains power supply systems are upgradable for battery backup via internal D-Cell (3.6 V 16.5 Ah) or external battery pack. 3 m (9.8 ft) for external connection to mains supply (without cable plug) 2 3 4 5 6 6-13 k06c-f660d-batt-std-3_rev11-2016

TECHNICAL SPECIFICATIONS - BATTERY-OPERATED WATER METER MAG 8000 FEATURES FEATURES Application identification Time and date Totalizer MAG 8000 Measurement Low flow cut-off 7ME6810 7ME6820 7ME6880 Empty pipe detection Data logger Alarm Data protection Battery power management Diagnostic Continuous self test including Alarm statistics and logging for fault analyzing Tag number up to 15 characters Real time clock 3 totalizer: Configurable to Forward, Reverse and Bidirectional netflow 1 totalizer (following totalizer 1 setting) resetable via display key 0.05 % of Qmax (adjustable) 0.25 % of Q3 1 % of Qmax (adjustable) Symbolised in display Logging of 26 records: selectable as daily, weekly or monthly logging Active alarm is indicated on the display All data stored in an EEPROM. Totalizers 1 and 2 are backed up every 10 min, statistic every hour and power consumption and temperature measurement every 4 hour. Password protection of all parameters and hardware protection of calibration and revenue parameters. Optimal battery information on remaining capacity. Calculated capacity includes all consuming elements and available battery capacity is adjusted related to change in ambient temperature. Numbers of power-ups. Date and time registered for first and last time power alarm. Coil current to drive the magnetic field Signal input circuit Data calculation, handling and storing Electrode impedance to check actual media contact Flow simulation to check pulse and communication signal chain for correct scaling Number of sensor measurements (excitations) Transmitter temperature (battery capacity calculation) Low impedance alarm for change in media Flow alarm when defined high flow exceeds Verification mode for fast measure performance check Insulation test Leakage detection Meter Utilization Tariff Settling date Statistic PC Configuration Software PDM Test of signal immunity against disturbance and bad installation. Test interval is selectable and measurement is interrupted during the test period of 4 min. Monitoring the lowest flow or volume during selected time window within 24 hours. Leakage is detected over a selectable period where monitored value exceed the possible leakage level. Min and max values are stored with date. Last store value visible on the display. 6 registers for monitoring total time the meter has operated in different flow intervals. Registered intervals are free selectable as % of Qn (Q3) 6 tariff registers count the volume delivered within the selected tariff windows, based on time of day or flow rates or a combination. Tariff can also be used for consumption profile where consumption is related to different time intervals or flow rates. Tariff values visible on the display. On a predefined date the totalizer 1 index value is stored. Old values are stored to show the latest two totalized 1 index values. Settling values visible on the display. Min. flow rate with time and date Max. flow rate with time and date Min. daily consumption with date Max. daily consumption with date Latest 7 days total and daily consumption Actual month consumption Latest month consumption Meter configuration online and offline mode Own parameter settings Parameter documentation Print and export of data and parameters PDM 6.0 Service Pack 2 Basic and Online version 6-14 k06c-f660d-batt-std-4_rev11-2016

DIMENSIONI / DIMENSIONS / S 114 (4.49) 131 (5.16) 115 (4.53) 104 (4.09) 84 (3.31) 161 (6.34) 155 (6.10) 152 (5.98) M20 161 (6.34) 155 (6.10) 152 (5.98) M20 161 (6.34) 155 (6.10) 152 (5.98) M20 A A A L L L 7ME6810 DN 25-40 (1"-1½") DN 50 300 (2" 12") DN 350 1200 (14" 48") L* PESI EN 1092-1 ANSI 16.5 AS 4087 AWWA C-207 AS 2129 WEIGHT / POIDS DN A PN10 PN16/non-PED PN40 PN16 (INCH) PN16 CLASS D TABLE E Kg** 25 188 - - 200 7.9 200-200 6 40 203 - - 200 7.9 200-200 9 50 178-200 - 7.9 200 - - 11 65 181-200 - 7.9 200 - - 13 80 191-200 - 7.9 200 - - 15 100 197-250 - 9.8 250 - - 17 125 210-250 - 9.8 250-250 22 150 224-300 - 11.8 300 - - 28 200 249 350 350-13.8 350 - - 50 250 276 450 450-17.7 450 - - 71 300 303 500 500-19.7 500 - - 88 350 365 550 550-21.7 550 - - 127 400 391 600 600-23.6 600 - - 145 450 421 600 600-23.6 600 - - 175 500 447 600 600-26.8 600 - - 225 600 497 600 600-32.3 600 - - 340 700 548 700 875/700 - N/A 700 700-316 750 573 N/A N/A - N/A N/A 750 - N/A 800 603 800 1000/800 - N/A 800 800-398 900 656 900 1125/900 - N/A 900 900-476 1000 708 1000 1250/1000 - N/A 1000 1000-602 1050 708 N/A N/A - N/A N/A 1050 - N/A 1100 759 N/A N/A - N/A N/A 1100 - N/A 1200 814 1200 1500/1200 - N/A 1200 1200-887 * Tolerances on build in length: DN 15 to DN 200 (½ to 8 ): +0/-3 mm (+0/-0.12 ), DN 250 to DN 400 (10 to 16 ): +0/-5 mm (+0/-0.20 ), DN 450 to DN 600 (18 to 24 ): +5/-5 mm (+0.20/-0.20 ), DN 700 to DN 1200 (28 to 48 ): +10/-10 mm (+0.39/-0.39 ) ** For remote version the sensor weight is reduced with 2 kg (4.5 lb) DIMENSIONI IN MM / DIMENSION IN MM / S MM 6-15 k06c-f660d-batt-dim-1_rev11-2016

REMOTE VERSION 71 (2.80) 13 (0.51) 71 (2.80) 13 (0.51) Ø8 (0.31) Ø12 (0.47) Ø8 (0.31) 120 (4.72) 31.5 (1.24) 104 (4.09) DIMENSIONI / DIMENSIONS / S 21.5 (0.85) 164 (6.46) 96 (3.78) 1 2 3 4 5 158 (6.22) 77 (3.03) 50.65 (1.99) 6 Dimensions in mm (inch), weight 3.5 kg (8 lb) EXTERNAL BATTERY PACK GROUNDING RINGS 4 (0.16) 44 (1.73) 4 (0.16) 3 (0.12) 20 (0.79) Ø8 (0.31) Ø12 (0.47) 12.4 (0.49) 75 (2.95) 10 (0.39) Ø6.5 (0.26) 189 (7.44) ØD h Ød 76.5 (3.01) Dimensions in mm (inch), weight 2.0 kg (4.5 lb) 47 (1.85) Battery pack has to be mounted in upwards position to ensure maximum battery capacity. 18.5 (0.73) Dimensions in mm (inch) for grounding rings MAG 8000 with NBR lining DN 25 to DN 300 Dimension Internal diameter (d) Outside diameter (D) DN 25 27 68 143 DN 40 38 88 163 DN 50 52 100 175 DN 65 64 120 195 DN 80 79 133 208 DN 100 95 158 233 DN 125 115 188 263 DN 150 145 216 291 DN 200 193 268 343 DN 250 246 324 399 DN 300 295 374 449 h 6-16 k06c-f660d-batt-dim-2_rev11-2016