MasterSwitch 230V. AP9210i

Similar documents
MasterSwitch 100V. AP9210j

Remote Power-Off Device AP9830

Rack Power Distribution Unit AP7530, AP7540

Triple Chassis. for Silcon. DP300E Series UPSs AP9604S AP9604SR

Broadband Automatic Disconnect Switch. User Manual

Vertical Console Port Server AP9290. Installation and Quick-Start

RPM1581HVN RPM20161VN RPM2082HVI RPM20162VI (Remote Power Manager) User s Manual

AC4G-D User s Manual

USER S GUIDE. masterswitch vm. Product Descriptions. Products Described in This Manual. MasterSwitch VM PDUs. MasterSwitch VM controller

Zonit μats TM Users Guide μats1-lv Version 1.2

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

Owner s Manual. HDMI Over Cat5 1x2 Extenders. Models: B126-2A1, B126-2A0

Owner s Manual. DVI over Cat5 Extenders and Extender/Splitters

Owner s Manual HDMI Matrix Switch

Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13

Pro Series Owner's Manual. 1. Introduction Controls and Indicators Troubleshooting Replacing the Battery Obtaining Service 11

Quick Start Guide. KVM Extender USB

Owner s Manual. DVI Single Link with Audio Splitter. Models: B A and B A

Owner s Manual. VGA Over Cat5 Extender Kits with EDID Copy 2 Local, 2 Remote. Models: B and B A

DisplayPort Multi-Display Splitter/Expanders. Models: B , B DVI, B HDMI

Owner s Manual. DVI over Cat5 Extenders and Extender/Splitters

Owner s Manual. USB 3.0 Docking Station for Microsoft Surface. Models: U342-GU3, U342-HGU3 PROTECT YOUR INVESTMENT!

Quick Start Guide. Dual USB Wall Charger with PD Charging, (x1) USB-A Port and (x1) USB-C Port. Model: U280-W02-A1C1

Owner s Manual. USB 3.1 Gen 1 USB-C to HDMI Adapter

Pro Series Owner's Manual. 1. Introduction Controls and Indicators Troubleshooting Replacing the Battery Obtaining Service 12

Owner s Manual. USB 3.1 Gen 1 USB-C to DisplayPort Adapter with Charging. Model: U444-06N-DP-C

Owner s Manual. USB 3.1 Gen 1 USB-C Docking Station, Aluminum. Model: U442-DOCK10-S

VGA Over Cat5 Extender with Audio

Owner s Manual. USB 3.1 Gen 1 USB Type-C to DVI Adapters

Owner s Manual. Audio/Video with RS-232 and IR Control over IP Extenders

DISCONTINUED PRODUCT DISCONTINUED PRODUCT

Owner s Manual. HDMI over Cat5 Extenders and Extender/Splitters

Quick Start Guide. NetDirector Console KVM Switch (8- or 16-Port) or Rackmount KVM Switch (8-Port)

Data Reporter. Installation-Operation E rev.f

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

Line-R. Models 600 and User s Manual

Owner s Manual. 2-Port DB9 RS-232 Serial PCI Card

Owner s Manual. Industrial-Grade USB 3.0 Hub. Models: U IND (4-Port), U IND (7-Port), U IND (10-Port)

Owner s Manual Automatic Voltage Switch

Owner s Manual. USB 3.1 Gen 1 USB-C to 4K HDMI Adapter with PD Charging. Models: U444-06N-H4K6WC, U444-06N-H4K6BC

TB-100 ControLynx Terminal Block

Owner s Manual. USB Type-C to HDMI, VGA, Gigabit Ethernet and USB-A Hub Adapter. Models: U444-06N-HV4GU (White), U444-06N-HV4GUB (Black)

Owner s Manual. USB 3.1 Gen 1 USB-C to 4K HDMI Adapter with Ethernet and PD Charging. Model: U444-T6N-H4GUBC

VIP-812A DUAL NETWORKED STATION PORT

Owner s Manual. Media Converters

Installation and Operation Back-UPS Pro BR700G-TW

Owner s Manual. USB to Serial Adapter. Model: U DB25 PROTECT YOUR INVESTMENT!

Owner s Manual. USB 3.1 Gen 1 USB Type-C to DVI Adapters

Quick Start Guide. USB 3.1 Gen 1 to DVI Alternate Mode Adapter. Models: U444-06N-DVI-AM (White), U444-06N-DVIBAM (Black)

Metered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R

Easy Installation Guide

Owner s Manual. USB to RJ45 Cisco Rollover Cable. Model: U RJ45-X PROTECT YOUR INVESTMENT!

Owner s Manual. Media Converters Models: N SC & N ST

Owner s Manual. USB 3.1 Gen 1 USB-C Docking Station. Models: U442-DOCK1, U442-DOCK1-B

Owner s Manual. Desktop Charging Stations. USB Charging (Model: CSD1006USB) AC Charging with Surge Suppression (Model: CSD1006AC)

VE8014A/VE8014AR QUAD NETWORKED STATION PORT

Owner s Manual. USB 3.1 Gen 1 USB-C to 4K HDMI Adapters

Owner s Manual. 5200mAh Mobile Power Bank

USB Ranger 110/410 User Guide

Owner s Manual. DisplayPort / Mini DisplayPort v1.2 Multi-Stream Transport Hubs

Portable Hard Drive USB 2.0 User Guide

Owner s Manual. USB 3.1 Gen 2 (10 Gbps) to Dual SATA Dock/Cloning Station. Model: U CG2. Este manual esta disponible en español en la página de

MEC-LAN-M002. User s Manual

Quick Start Guide. USB 3.1 Gen 1 to DisplayPort Alternate Mode Adapter White. Model: U444-06N-DP-AM, U444-06N-DP-RA (Right Angle)

Metered Rack PDU Rack PDU, Metered, Zero U, 5.7kW,208V,(36)C13& (6)C19; 10' Cord

User s Guide. POWERVAR Single Phase Power Conditioners

DCM Digital Control Modules

Metered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord

Owner s Manual. USB 3.1 Gen 1 USB-C to VGA Adapter

Owner s Manual. USB 3.1 Gen 1 USB-C Docking Station - Silver. Model: U442-DOCK4-S. USB Type-C and USB-C are trademarks of USB Implementers Forum.

MFJ ENTERPRISES, INC.

Quick Start Guide. USB 3.1 Gen 1 to HDMI Alternate Mode Adapter. Models: U444-06N-HD-AM, U444-06N-HDB-AM

Owner s Manual. HDMI to VGA + Audio Splitter 2-Port. Model: P131-06N-2VA-U

Back-UPS RS APC Back-UPS RS 800VA 120V Black

Automated Tuner System Power Distribution Hub

Installation and Configuration

USB Ranger 422 User Guide

Owner s Manual. 4-Port RS-232 Serial PCIe Card with Breakout Cable

Owner s Manual. USB Peripheral Sharing Switch

NI CB-37F-LP. Introduction INSTALLATION GUIDE. Connector Block for 37-Pin D-Sub Devices

Console Port Server (AP9301, AP9302, AP9303) Installation and Configuration

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Installation and Operation

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

CA-A480-A Elevator Controller. Reference & Installation Manual

Owner s Manual 2-Port USB to Serial Adapter Cable

Owner s Manual. DVI USB KVM Switch with Audio. Models: B004-DUA2-K-R, B004-DUA4-K-R

SpectraGuard Sensor SS-300-AT-C-50 Technical Specifications

MEC-COM-M114. User s Manual

Owner s Manual. Industrial-Grade USB to RS-422/485 Serial Adapter. Models: U IND (1-Port), U IND (2-Port), U IND (4-Port)

ChemiDoc and ChemiDoc MP Imaging Systems with Image Lab Touch Software Installation Qualification Protocol (IQ)

MEC-SAT-M002. User s Manual

1 LIMITED WARRANTY STORCASE TECHNOLOGY, Incorporated ( StorCase ) warrants that its products will be free from defects in material and workmanship, su

Installation and Operation Back-UPS Pro 900

PS8 - II. Professional Power Sequencer. User s Manual

FP-PS-4. Features. Installation

Owner s Manual. 1-Port Gigabit Ethernet (GbE) PCI Express (PCIe) Card

MEC-USB-M002. User s Manual

Owner s Manual. USB Type-C to Serial Adapter Cable. Model: U C. * USB Type-C and USB-C are trademarks of USB Implementers Forum

USB Ranger Fiber Optic USB 2.0 Extender. User Guide

Transcription:

MasterSwitch 230V AP9210i

Thank You! Thank you for selecting the MasterSwitch 230V network-manageable power control unit (PCU). The MasterSwitch 230V has been designed for many years of reliable, maintenance-free service in combination with your American Power Conversion (APC) uninterruptible power supply (UPS). APC is dedicated to the development of high-performance electrical power conversion and control products. We hope that you will find this product a valuable, convenient addition to your computing system. Please read this manual! It provides important safety, installation, and operating instructions that will help you get the most from your MasterSwitch 230V. Save this manual! It includes instructions for obtaining warranty service. Declaration of Conformity Application of Council Directives: Standards to which conformity is declared: Manufacturer s Name and Address: 89/336/EEC EN55022, EN50082-1 American Power Conversion 132 Fairgrounds Road West Kingston, Rhode Island, 02892, USA -or- American Power Conversion (A. P. C.) b. v. Ballybritt Business Park Galway, Ireland Importer s Name and Address: American Power Conversion (A. P. C.) b. v. Ballybritt Business Park Galway, Ireland Type of Equipment: UPS Accessory Equipment Model Numbers: AP9210I Serial Numbers: WA9801000000-WA9952999999 Years of Manufacture: 1998, 1999 We, the undersigned, hereby declare that the equipment specified above conforms to the above directives. St. Louis, MO 1/7/98 Place Date Dan Rohr Design Engineer Galway, Ireland 1/7/98 Place Date Ray Ballard General Manager, Galway

Contents 1 Introduction....................... 1 1.1 Overview 1 1.2 Hardware Requirements 1 1.3 Online Documentation 1 2 Product Description.................. 2 2.1 Inventory 2 2.2 Front Panel 3 2.3 Rear Panel 4 2.4 Status Indicator 4 3 Installation........................ 5 3.1 Desktop Installation 5 3.2 Rackmount Installation 5 4 Setup............................ 7 4.1 Defining Address Values 7 4.2 Configuration Using SNMP 7 4.3 Checking Operation 7 5 Problem Resolution.................. 8 5.1 Troubleshooting 8 5.2 If Problems Persist 8 6 Specifications..................... 10 i

1 Introduction 1.1 Overview The MasterSwitch is a network-manageable, intelligent power control unit (PCU) designed to provide control of power for up to eight 230-VAC electrical devices. The MasterSwitch allows you to: Individually control each of eight outlets using a web browser, a Simple Network Management Protocol (SNMP) browser, telnet, or a terminal program. Remotely and individually reboot hung servers. Remove power to non-essential loads. Sequentially apply power to equipment that is plugged into the MasterSwitch. 1.2 Hardware Requirements MasterSwitch 230V requires an IEC power cord rated at 10 amps, 230VAC. 1.3 Online Documentation The diskette that comes with the MasterSwitch includes a copy of the MasterSwitch User Guide in portable data format (pduguide.pdf). This guide can be read using Acrobat Reader, a free application available from Adobe (http//:www.adobe.com). If you do not have web capabilities, a copy of this guide is available from the APC FTP site (apccorp.apcc.com). 1

2 Product Description 2.1 Inventory In addition to this installation guide, the MasterSwitch also comes with the following items: Two rack-mounting brackets. (See Table 1.) Four screws for attaching the rack-mounting brackets to the MasterSwitch. (See Figure 1.) One DB9 female cable (APC PN 940-0103) for connecting a terminal (or terminal emulator) to the MasterSwitch for configuration. (See Figure 1.) One diskette which contains a copy of the MasterSwitch User Guide (pduguide.pdf) in Portable Document Format (PDF), as well as a copy of the MasterSwitch Management Information Base (MIB) that provides the object identifiers (OIDs) needed to use an SNMP browser to monitor and control the MasterSwitch. One copy of the warranty card. Note: Please fill out and return the warranty card. This card not only provides us with valuable feedback on how we can refine our products to better serve your needs, but also enables us to notify you about important product updates and changes. Release notes may also be included to advise you of any information that has become relevant since this Installation Guide and the online User Guide were last revised. Figure 1: MasterSwitch 230V with Rack-Mounting Brackets and Configuration Cable 2

2.2 Front Panel As shown in Figure 2, the MasterSwitch also features: A 9-pin configuration port for connecting the MasterSwitch to a terminal (or terminal emulator) during the setup procedures. (See Installation on page 5.) This connection is made using the 9-pin cable (APC PN 940-0103) that comes with the MasterSwitch. An 8-pin RJ45 jack for connecting the MasterSwitch to a 10Base-T Local Area Network (LAN). Two LEDs Link and Status for monitoring the network connection. Eight LEDs one for each receptacle to report power on or off conditions of the MasterSwitch power outlets. A reset button that reinitializes the MasterSwitch without affecting its outlet power (warm reboot). Reset Button Network Status LEDs Configuration Port 10 Base-T Network Port Receptacle Status LEDs www.apcc.com Figure 2: MasterSwitch 230V Front Panel 3

2.3 Rear Panel As shown in Figure 3, the MasterSwitch has: Eight 230-VAC, 10-amp power receptacles (8 IEC 320). One circuit breaker. 2.4 Status Indicator Figure 3: MasterSwitch 230V Rear Panel The MasterSwitch has eight receptacle status leds located on the front panel. When a status LED is on, it indicates the corresponding receptacle has power. When a status LED is off, its receptacle does not have power. The front panel of the MasterSwitch also has two leds that display network connection status. Refer to Table 1. LED STATE INDICATION Link RX/TX Blinking Green Off Solid Green MasterSwitch is connected to a working network. MasterSwitch has failed to connect with a network. MasterSwitch is ok. Status Blinking Green Network configuration values have not been defined for the MasterSwitch. Flashing Red Processing bootp. (See Section 4.) Solid Red Hardware failure. Table 1: Network Connection (10Base-T) Status Indicators 4

3 Installation The MasterSwitch, which connects to a 10Base-t LAN through the RJ45 jack on the front of the unit, can be used as a freestanding desktop unit or mounted in an APC NetShelter cabinet (or other 19" NEMA rack). 3.1 Desktop Installation The MasterSwitch is equipped with rubber feet for desktop use and can be located wherever space permits. To install MasterSwitch on a desktop: 1 Place the MasterSwitch in its permanent location. Make sure that this location is within 3 meters of a single-phase, 230-VAC, 10-amp outlet, and that the back of the unit (receptacle side) will be readily accessible. 2 Plug the male end of your network interface cable (not supplied with the MasterSwitch) into the RJ45 jack on the front of the MasterSwitch. 3 Plug the MasterSwitch power cord into the single-phase, 230-VAC, 10-amp outlet. Refer to See Section 4 for information on setting up the MasterSwitch. 3.2 Rackmount Installation To mount the MasterSwitch in a NetShelter (or other 19" NEMA rack): 1 Peel the rubber feet from the bottom of the MasterSwitch. 2 Attach the mounting brackets to the MasterSwitch. (See Figure 4.) Use a #2 Phillips-head screwdriver and two of the supplied screws to attach each mounting bracket to the MasterSwitch. Note: The mounting brackets can be attached at various positions along the side of the chassis. Choose a position that will allow sufficient room between the mounted MasterSwitch with attached cables and the cabinet door in its closed position. If more than two mounting holes are aligned, choose the pair that are farthest apart. 5

Figure 4: Attaching Mounting Brackets 3 Mount the MasterSwitch into the NetShelter cabinet (Figure 5) with four caged nuts and machine screws (not supplied with the MasterSwitch). If the MasterSwitch is being installed in a cabinet other than a NetShelter, use hardware that is appropriate for the cabinet. 4 Plug the male end of your network interface cable (not supplied with the MasterSwitch) into the RJ45 jack on the front of the MasterSwitch. 5 Plug the MasterSwitch power cord into a single-phase 230-VAC, 10-amp outlet. 6 See Setup on page 7 for information on setting up the MasterSwitch. Figure 5: Mounting MasterSwitch in a NetShelter Cabinet 6

4 Setup 4.1 Defining Address Values Before the MasterSwitch can operate over the network, it needs to have certain address values defined. These values can be set by a server using the Bootstrap Protocol (BOOTP) or by a terminal (or terminal emulator) connected to the 9-pin configuration port on the front panel of the MasterSwitch. The MasterSwitch comes with bootp enabled. Refer to the MasterSwitch User Guide for information on the initial configuration of the MasterSwitch. See Online Documentation on page 1 of this manual. 4.2 Configuration Using SNMP If you want to use SNMP to configure and control the MasterSwitch, you will need to load and compile the APC MasterSwitch MIB at any network management station (NMS) that you plan to use for SNMP control of the MasterSwitch. The MasterSwitch MIB is provided on the diskette that came with the MasterSwitch. If you want to use this MIB, see the documentation for instructions on loading and compiling MIBs. 4.3 Checking Operation After the MasterSwitch is installed and set up: Confirm the network connection by checking that the status LEDs (Link and Status) are on. Confirm that all eight of the receptacle status LEDs are on. 7

5 Problem Resolution 5.1 Troubleshooting PROBLEM POSSIBLE CAUSE SOLUTION No power from any receptacle. Network connection LEDs do not come on. Circuit breaker trips continously or frequently. Blown MasterSwitch circuit breaker or no input power. Connection to network is faulty. Amperage drawn by load equipment exceeds 10-amp maximum Reset circuit breaker, or correct input power problem. Make sure network cable is securely connected to the MasterSwitch and network. Limit load equipment to those devices which together draw less than 10 amps. 5.2 If Problems Persist If the MasterSwitch requires service: Table 2: Troubleshooting 1 Check the MasterSwitch using Table 2 before calling for service. 2 Note the model number of the MasterSwitch, the serial number, and the date purchased. See the back cover of this manual for the correct telephone number and call apc Technical Support. A technician will ask you to describe the problem in order to help solve it over the phone. 3 If the MasterSwitch requires servicing, the technician will give you a return merchandise authorization (RMA) number. If APC Technical Support is not available in your area, call the dealer that sold the MasterSwitch. If it is under warranty, repairs are free. Otherwise there will be a charge for repair. 4 It is important to pack the MasterSwitch properly to avoid damage in transit. If possible, use the original packing materials. Damage sustained in transit is not covered under warranty. 5 Include a letter with your name, RMA number, address, copy of the sales receipt, description of the trouble, your daytime phone number, and a check (if necessary). 8

6 Mark the RMA number on the outside of the package. The factory cannot accept any package without this marking. 7 Return the MasterSwitch by insured, prepaid carrier to the address given by the technician. 9

6 Specifications TYPE ITEM SPECIFICATION Electrical Physical Environmental Approvals Input Nominal input voltage: Acceptable input voltage: Nominal input frequency: Overcurrent protection: Input connector: Output Output connectors: Maximum total current draw: Size (h w d) Without mounting brackets: With mounting brackets: Weight Net weight: Shipping weight: Elevation Operating: Storage: Temperature Operating: Storage: 230 VAC 207 253 VAC 50/60 Hz 12 (resettable circuit breaker) IEC 320 inlet connector IEC 320 receptacles 10 A 5.4 43.2 16.5 cm 4.8 48.3 16.5 cm 3.0 kg 4.5 kg 0 to 3000 m 0 to 15,000 m 0 to 40 C 0 to 45 C CISPR, CE, VDE Table 3: MasterSwitch Specifications 10

Limited Warranty American Power Conversion (APC) warrants MasterSwitch 230V to be free from defects in materials and workmanship for a period of two years from the date of purchase. Its obligation under this warranty is limited to repairing or replacing, at its own sole option, any such defective products. This warranty does not apply to equipment which has been damaged by accident, negligence, or misapplication or has been altered or modified in any way. This warranty applies only to the original purchaser. To obtain service under warranty you must obtain a Returned Material Authorization (RMA) number from APC or a designated APC service center. Products must be returned to APC or an APC service center with transportation charges prepaid and must be accompanied by a brief description of the problem encountered and proof of date and place of purchase. EXCEPT AS PROVIDED HEREIN, AMERICAN POWER CONVERSION MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MER- CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Some states do not permit limitation or exclusion of implied warranties; therefore, the aforesaid limitation(s) or exclusion(s) may not apply to the purchaser. EXCEPT AS PROVIDED ABOVE, IN NO EVENT WILL APC BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT, EVEN IF ADVISED OF THE POS- SIBILITY OF SUCH DAMAGE. Specifically, APC is not liable for any costs, such as lost profits or revenue, loss of equipment, loss of use of equipment, loss of software, loss of data, costs of substitutes, claims by third parties, or otherwise. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. Life support policy As a general policy, APC does not recommend the use of any of its products in life support applications where failure or malfunction of the APC product can be reasonably expected to cause failure of the life support device or to significantly affect its safety or effectiveness. APC does not recommend the use of any of its products in direct patient care. APC will not knowingly sell its products for use in such applications unless it receives in writing assurances satisfactory to APC that (a) the risks of injury or damage have been minimized, (b) the customer assumes all such risks, and (c) the liability of American Power Conversion is adequately protected under the circumstances. Examples of devices considered to be life support devices are neonatal oxygen analyzers, nerve stimulators (whether used for anesthesia, pain relief, or other purposes), autotransfusion devices, blood pumps, defibrillators, arrhythmia detectors and alarms, pacemakers, hemodialysis systems, peritoneal dialysis systems, neonatal ventilator incubators, ventilators for both adults and infants, anesthesia ventilators, and infusion pumps as well as any other devices designated as critical by the U.S. FDA, or other competent authority. Hospital grade wiring devices and leakage current may be ordered as options on many APC UPS systems. APC does not claim that units with this modification are certified or listed as Hospital Grade by APC or any other organization. Therefore these units do not meet the requirements for use in direct patient care.

Toll free technical support: U. S. & Canada 1-800-800-4272 Austria 0660 6480 Belgium 0800 15063 Czech Republic 0 800 102063 Denmark 800 18 153 Finland 9800 13 374 France 0 800 906 483 Germany 01300818907 Holland 0800 0224655 Hungary 00800 12221 Ireland 1 800 702000 x 2045 Israel 177 353 2206 Italy 1678 74731 Japan 0120-80-60-90 Luxembourg 0800 2091 Norway 800 11 632 Poland 00800 353 1202 Portugal 050 553182 South Africa 0800 994206 Spain 900 95 35 33 Sweden 020 795 419 Switzerland 0800 556177 Turkey 0800 35390275 U. K. 0800 132990 Areas without toll free numbers: Addresses: American Power Conversion Corporation 132 Fairgrounds Road P. O. Box 278 West Kingston, Rhode Island 02892 USA American Power Conversion Corporation (A. P. C.) b. v. Ballybritt Business Park Galway Ireland American Power Conversion BR Gotanda 7 th Floor 2-30-4 Nishi-gotanda, Shinagawa-ku Tokyo 141 Japan http://www.apcc.com +1 401 789 5735 (USA) or +353 91 702020 (Ireland) +7095 916 7166 (Russia) Serial number: Entire contents copyright 1998 American Power Conversion. All rights reserved. Reproduction in whole or in part without permission is prohibited. MasterSwitch is a trademark of APC. All other trademarks are the property of their respective owners. 990-0205 Rev. 2 5/98