Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

Similar documents
Multifunction Transducer MT440

Voltage Transducer UMT516 / MT516

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

Plug-in module SIRAX TV 808, 2 channels Isolating Amplifier unipolar/bipolar

IST ULTRASTAB Power Supply for IT/ITN ULTRASTAB transducers

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

JUMO Quantum PID100/PID200/PID300

SUBJECT TO CHANGE WITHOUT NOTICE

IST ULTRASTAB Power Supply for high precision transducers

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet

TM3TM3 module TM3-2 temperature inputs and 1 analog output

WG 20. The WG 20 achieves an extraordinarily. accuracy for hazardous-area. applications.

Energy meters Single phase electrical energy meters WM1-6 / WM1M6

MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

TM3TI4 module TM3-4 inputs temperature

Controller module. Brief description. Features. Block structure. Page 1/7. Data Sheet

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

MINI MCR-SL-PT100-UI(-SP)(-NC)

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet

Standard-Signal Isolation Amplifiers. VariTrans A 21000

itemp TMT180 Technical information

PHOENIX CONTACT Features

DINALOG A 144 x 36 A1400 Light-Strip Indicator

SensoTrans DMS A 20220

UNIVERSAL CURRENT CONVERTER

Digital input modules

TM3AI4 module TM3-4 analog inputs

Controller module. Brief description. Features. Block structure. Data Sheet Page 1/7

MINI MCR-SL-PT100-UI-200

MIC-2 Multi-instrument DATA SHEET

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

Signal Doublers. VariTrans A 20300

MIC-2 MKII, Multi-instrument DATA SHEET

MINI MCR-SL-UI-2I-NC. Extract from the online catalog. Order No.:

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

Digital Indicating Controllers. JC Series. High performance controllers...at the lowest prices anywhere! Toll Free

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

SX90 Process Controller

Process displays For current and voltage

Contact protection relay

Compact Universal Controllers

VariTrans B The world s first 3-port standard signal isolator in a 6-mm modular housing.

VariTrans A The specialist for ±10 V and ±20 ma. With calibrated range selection and broad-range power supply.

DATA SHEET Selectable AC transducer, TAS-331DG

MINI MCR-SL-UI-2I(-SP)(-NC)

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

RM35LM33MW liquid level control relay RM35-L V AC/DC

Electronic timer CT-AWS Impulse-OFF with 2 c/o contacts Data sheet

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

Energy Management Energy Transducer Type ET112

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

MODEL: R1M-GH. PC Recorders R1M Series

Data sheet ACT20P ACT20P-CMT-10-AO-RC-S. Phone: Fax: Web: - [!

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

PI-EX-ME-2NAM/COC-24VDC

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

Displays Transducers. Displays and transducers

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

TM3TI8T module TM3-8 inputs temperature

ISOMETER isoev425 with coupling device AGH420

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

TM3TI4 module TM3-4 inputs temperature

RM35TF V AC

Expansion Module HZS 541-1S

Zelio Control-modular measurement and control relays 1

Transducers for Pt-100/1000, Resistors

Electronic timer CT-ERD ON-delayed with 1 c/o contact Data sheet

PI-EX-ME-2NAM/COC-120VAC

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

SAX.. ACVATIX Electromotive actuators for valves. with a 20 mm stroke

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

MCX08M2 Programmable controller

Assembly. Front view. LED yellow: Relay output I. LED yellow: Relay output II

Electronic timer CT-VWD Impulse-ON with 1 c/o contact Data sheet

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

PTC/PT100 board 2.0 Option

02/11/2015

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

AIAS. Technical description

Non-Contact Safety System CES-AZ

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Non-communicating room controllers

ISOMETER isoev425/isoev425hc with coupling device AGH420

DATA SHEET Selectable AC transducer, TAS-321 DG

Transcription:

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450 o Measuring of resistance of RTD sensors (Pt100, Pt1000, Ni100, Cu10,...) o Accuracy class up to: 0.5 o Programmable input and output o Serial communication RS232 or RS485, MODBUS protocol o Universal AC/DC or AC Auxiliary power supply 1 MI450 Programmable transducers for RTD sensors

PROPERTIES o Measuring of resistance of RTD sensors (Pt100, Pt1000, Ni100, Cu10*,...) o Accuracy class: 0.5 (Cu10 - Accuracy class: 1*) o Programmable input and output o Serial communication RS232 or RS485, MODBUS protocol o Universal AC/DC or AC Auxiliary power supply o (very high speed data rate: up to 115,200 bit/s, MODBUS protocol) o Low power consumption o Housing for DIN rail mounting o Correspond to EN 60770-1: 1999 LAYOUT AND MODE OF OPERATION Resistance on the input terminals can be measured with three methods, two, three or four wire connection. In all cases U-I method is used for measuring. Enforced current causes a voltage drop (A - Picture 2) on measured RTD sensor which is supplied to the programmable amplifier B. After A/D conversion the signal is computed in microprocessor C. The measured value determined by the microprocessor is assigned to the programmable analogue output E. Communication D enables programming of the measuring transducer and monitoring of the measuring resistance on the input terminal. Communication, analogue output and auxiliary power supply are electrically insulated from other system by means of separation transformer. *See chapter Technical data - Accuracy. APPLICATION Measuring transducer MI450 is designed for use in industrial process for conversion of nonlinear resistance sensors (RTD sensors) in to appropriate DC current or DC voltage signal. The analogue output signal is proportional to the measured value and it is appropriate for regulation of analogue and digital devices with reasonable dependence on environmental conditions, where they are planned to be used. Picture 1: Block diagram PROGRAMMING Input and output values are programmed 1) with MiQen setting software via RS232 or RS485 communication. Before setting the transducer, output value must be selected by the jumpers on the output module 2). It is possible to choose between three ranges 0 ±10 V, 0 ±5 ma and 0 ±20 ma. Within this three ranges it is possible to set any linear or bent (with maximum 5 break points) output. 1) Programming is not possible in versions without communication 2) Qualified person only VERSIONS The following transducer versions are available as programmable via communication or to be specified at the placing order: Type of Measuring Bent of Input Output Supply Communication RTD voltage analogue output -200 to 850 C for Pt..., -60 to 250 C for Ni..., 20Ω to 10kΩ for polinom 3), -50 to 250 C for Cu... Pt100 Pt1000 Ni100 Cu10* < 2.2 V 1 ma 5mA 10 ma 20 ma 4...20 ma 1 V 10 V other on request Universal or Table 1: Versions of MI450 3) With program package MiQen it is possible to set 6 th grade polynomial function *Cu10: Accuracy class 1; see chapter Technical data. Transducers are mounted on standard rail 35 x 15 mm (according to DIN EN 50022) AC: 57 V 100 V 230 V 400 V 500 V RS232 or RS485 Programmable via communication or to be specified at the placing order 2 MI450 Programmable transducers for RTD sensors

TECHNICAL DATA GENERAL: Measured quantity: Measured principle: INPUT: temperature from RTD sensor microprocessor sampling Measuring method: two wire connection three wire connection four wire connection Input range with programmable ratings: RTD sensors limit values: Measuring voltage: 20 Ω to 10 kω < 2.2 V Minimum temperature range 4) : 100 K Minimum differential resistance 5) : 40 Ω (100Ω -> 140Ω) Lead resistance: < 10 Ω per lead Consumption: < 0.5 VA 4) Cu10: 80 K 5) Cu10: 3 Ω (10Ω -> 13Ω) ANALOGUE OUTPUT: Programmable DC current output: Output I OutN (output range end value): Output range values 6) : 0 ±1 ma to 0 ±5 ma or, 0...±5 ma to 0...±20 ma Burden voltage: 15 V External resistance: RBmax.[kΩ]= 15V IOutN [ma] 6) - Depends of set jumpers on output module Programmable DC voltage output: Output U OutN (output range end value): Output range values Burden current: 0 ±1 V to 0 ±10 V 20 ma UOutN [V] External resistance: R Bmin.[kΩ]= 20mA General: Response time: programmable from 0.5 s to 60 s Residual ripple: < 1 % p.p. Maximum output value: limited at 125 % All the output range end values can be reduced subsequently using the programming software, but a supplementary error results. ACCURACY: Reference value: Input range end value Accuracy class: Analogue output 7),8) : Temperature 0.5 c Communication 8) : Temperature 0.5 7) To calculate intrinsic error, see chapter intrinsic-error (for analogue outputs) on this page. 8) Cu10: Accuracy class 1, due to low resistance range (10Ω -> 13Ω). Reference conditions: Ambient temperature: 15 30 C Input: 0...100 % R N Intrinsic-error (for analogue outputs): For intrinsic-error for analogue outputs with bent or linear-zoom multiply accuracy class with correction factor (c). Correction factor c (the highest value applies): Linear Bent x x c y0 1 y x0 1 xe c = e = or 1 b 1 xb b - number of break points (1 to 5) Picture 3: Examples of settings with linear and bent POWER SUPPLY: Auxiliary AC/DC voltage (universal): Rated voltage (Ur): Frequency range: Power consumption: 24 300 V DC 40 276 V AC 40 70 Hz < 3 VA Picture 2: Output transfer N Number of sliding windows t Sampling time The output may be either short or open-circuited and it is electrically insulated from all other circuits (floating). Auxiliary AC voltage: 9) Rated voltage (Ur) 57.74 V 100 V 230 V 400 V 9) 500 V 9) Rated operating range 80 120 % Ur to 300 V installation category III, from 300 to 500 V installation category II see chapter Regulations. Table 3: Rated AC voltage for Auxiliary power supply Frequency range: 45 65 Hz Power consumption: < 3 VA MI450 Programmable transducers for RTD sensors 3

COMMUNICATION (OPTIONAL): RS232 Connection type: Point to point Signal levels: RS232 Maximum cable length: 15 m Connector: Screw terminals Isolation: 3.7 kv rms for 1 minute between all terminals and all other circuits, except between communication terminals and output terminals, 2 kv rms for 1 minute Transmission mode: Asynchronous Message format: MODBUS RTU Data rate (very high speed): 1.200 to 115.200 bits/s RS232 connections MI450 9 pin D connector (PC) 25 pin D connector (PC) Rx (21) Tx (3) Tx (2) (22) GND (5) GND (7) Tx (23) Rx (2) Rx (3) Table 4: RS232 connections Picture 4: Connection of MI450 on PC via RS232 communication RS485 Connection type: Multi-drop (32 connections per link) Signal levels: RS485 Cable type: Screened twisted pair Maximum cable length: 1000 m Connector: Screw terminals Isolation: 3.7 kv rms for 1 minute between all terminals and all other circuits, except between communication terminals and output terminals, 2 kv rms for 1 minute Transmission mode: Asynchronous Message format: MODBUS RTU Data rate (very high speed): 1,200 to 115,200 bits/s RS485 connections HOUSING: Material of housing: PC/ABS uninflammable, according to UL 94 V-0 Mounting: For rail mounting, 35 x 15 mm according to DIN EN 50022: 1978 Enclosure protection: IP 50 (IP 20 for connection terminals) according to EN 60529: 1989 Weight: Approx. 300 g CONECTION TERMINALS: Permissible cross section of the connection leads: 4.0 mm 2 single wire 2 x 2.5 mm 2 fine wire REGULATIONS: Protection: Test voltage: ENVIRONMENTAL CONDITIONS: Protection class II 300 V rms, installation category III 500 V rms, installation category II Pollution degree 2 3.7 kv rms according to EN 61010-1: 1990 Climatic rating: Climate class 2 acc. to EN 60688: 1992 Operating temperature -10 to +55 C Storage temperature -40 to +70 C Annual mean relative humidity: 75% r.h. EU DIRECTIVES CORRESPONDING FOR CE MARKING Low voltage directive 73/23/EEC: EN 61010-1: 1993 and EN 61010-A3: 1995 Safety requirements for electrical equipment for measurement, control, and laboratory use, Part 1: General requirements EMC directive 89/336/EEC: EN 61326-1: 1997 Electrical equipment for measurement, control, and laboratory use EMC requirements, Part 1: General requirements. Commentary: If strong HF electromagnetic fields are expected in the place where transducer will be used, usage of 5mA analogue output is recommended, because in that case field influence on the transducer is the lowest. MI450 RS485 A (21) DATA + C (22) NC 10) B (23) DATA - Table 5: RS485 connections 10) NC do not connect Picture 5: Connection of MI450 on RS485 communication line 4 MI450 Programmable transducers for RTD sensors

Marking Measuring transducers with linear : One label at the front of housing (Picture 7a): Measuring transducers with bent : One label at the front of the housing and additional label at the top of the housing (Picture 7b): Picture 6a: Example of label for transducer with linear CONNECTION Picture 6b: Example of label for transducer with bent Type of connection can be specified with the order or changed via communication with MiQen software. The connection terminals marking can be found on the front plate. Picture 7a: Connection diagram 4-wire Picture 7b: Connection diagram 3-wire DIMENSIONAL DRAWING Picture 7c: Connection diagram 2-wire Picture 8: Dimensional drawing (all dimensions are in mm) MI450 Programmable transducers for RTD sensors 5

SPECIFICATION AND ORDERING INFORMATION For ordering it is necessary to declare type of the transducer (MI450), type of RTD sensor or polynomial function, measuring range, output quantity and range, type of power supply, type of communication and shape of output. ORDERING CODE: MI450 b; c; d e F; G; H(i V); J; K MI450 Value Code b Type of sensor or input polynomial function of X 6 order c Measuring range: d e F G H i J K Start value of output signal End value of output signal Type of output signal Type of connection Type of power supply Value of power supply voltage (only for AC power supply) Type of communication Type of output Pt100; Pt1000; Ni100; Cu10*... -200 to 850 C (depends of sensor type) 20 Ω to 10 kω (for polynomial function) -20 20 - current output -10 10 - voltage output 0 20 - current output 0 10 - voltage output current - ma voltage - V b -200 c 850 20 Ω c 10 kω -20 c 20 1 d 20 ma 2 - wire 2 3 - wire 3 4 - wire 4 universal power supply AC power supply V U 57 V 57 100 V 100 110 V 110 230 V 230 300 V 300 RS 232 2 RS 485 4 no communication 0 linear 11) bent 1 5 (number of break points) Table 6: Ordering information Voltage - V A L 1 I 5 *Cu10: Accuracy class 1; see chapter Technical data - Accuracy. 11) - For ordering code for bent see additional ordering information Table 7. ORDERING EXAMPLE FOR TRANSDUCER WITH LINEAR OUTPUT CHARACTERISTIC Measuring transducer MI450, for Pt100 RTD sensor with temperature range 0 100 C, output range 4 20 ma, 4-vire connection, 110 V AC power supply, communication RS232 and linear output (Graph 1). MI450 Pt100; 0...100 ; 4 20 ma; 4; A 110 V; 2; L. V Additional ordering information For ordering transducer with bent it is necessary to declare breaking points in output (maximum 5 breaking points). Ordering code for transducers with bent output : MI450 b; c; d e F; G; H(i V); J; K(l 1 /m 1 ;l 2 /m 2 ; ) l m MI450 Value Code value of input quantity value of output quantity when input value is k depends of measuring range -20 20 (depends of output range) -200 l 850 or 20Ω l 10 kω (depends of measuring range and type of RTD sensor) -20 m 20 Table 7: Ordering information for bent The sequence of breaking points must rise with measured quantity. ORDERING EXAMPLE FOR TRANSDUCERS WITH BENT OUTPUT CHARACTERISTIC Measuring transducer MI450 for Pt100 RTD sensor with temperature range 0 500 C, output range 0 10 ma, 4-vire connection, universal power supply, communication RS485 and bent output. The transducer is zooming the range from 150 C to 250 C (Graph 2) MI450 Pt100; 0...500 ; 0 10 ma; 4, U; 4; 2(150/2; 250/8) Graph 2: Example of bent output with two breaking points Graph 1: Example of linear output 6 MI450 Programmable transducers for RTD sensors

Printed in Slovenia Subject to change without notice Version 4.02 / Oct-2015 GB P 22.495.301