Artistic Licence. Mica. User Guide. Mica User Guide. Version 1-1

Similar documents
Artistic Licence. Net-Lynx I/P. User Guide. Net-Lynx I/P User Guide. Version 1-5

Artistic Licence. Net-Lynx O/P. User Guide. Net-Lynx O/P User Guide. Version 1-5

Artistic Licence. Rail-Demux. User Guide. Rail-Demux User Guide. Version 2-7

Artistic Licence. Rail-Split RDM. User Guide. Serial nos and upwards. Rail-Split RDM User Guide. Version 5-0

Artistic Licence. Rail-Switch II. User Guide. Rail-Switch II User Guide. Version 5-5

Artistic Licence. Cata-Lynx I/P. User Guide. Cata-Lynx I/P User Guide. Version 1-4

Artistic Licence. Rail-Split extreme. User Guide. Serial numbers 151 upwards. Rail-Split extreme User Guide. Version 5-0

Artistic Licence. matisse d4 dmx. User Guide. matisse d4 dmx User Guide. Version 1-1

Artistic Licence. Rail-DALI-DMX. User Guide. Rail-DALI-DMX User Guide. Version 1-5

Artistic Licence. artlynx duo. User Guide. artlynx duo User Guide. Version 1-0

Artistic Licence. Ether-Lynx II. User Guide. Ether-Lynx II User Guide. Version 1-5

Artistic Licence. daligate quad. User Guide. daligate quad User Guide. Version 1-0

Artistic Licence. Dali-Scope. User Guide. Dali-Scope User Guide. Version 1-8

Artistic Licence. versasplit. User Guide. versasplit User Guide. Version 1-5

Split2.8 RDM. 2 input DMX/RDM Splitter. User guide

Artistic Licence Price List

Artistic Licence. nanoscope. User Guide. nanoscope User Guide. Version 1-0

EtherN.8 RDM & EtherN.2 RDM

DIN-Rail Mounting 6-port 100M/Gigabit Layer 2 Unmanaged Industrial PoE Ethernet Switch

Flexoled FTP3HP RGB LED DMX Driver

CS2 DMX Distribution Splitter

KPW-T2P25. PoE Splitter. Industrial IEEE 802.3at High Power. User s Manual -1- DOC

Blitzer Strobe. User Manual. Order code: EQLED366

FTP1 Single Channel LED DMX Driver

UV Power Flood. User Manual. Order code: EQLED029

RGB Power Batten. User Manual. Order code: EQLED032

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink

Features: S98-B v1.0 S98-B 9-port switch with buffer power supply for 8 IP cameras

LASERMET SLIMJIM LED SIGN INSTRUCTION MANUAL LEDS-SJ XXX

Blitzer RGB Strobe. User Manual. Order code: EQLED365

Features and Benefits. Certifications

Microbar COB System. User Manual. Order code: EQLED137

Features: DSB98 v1.0 DIN rail mounted switch 9-port DSB98 with buffer power supply for 8 IP cameras

Product Manual. USB Charging Hub 10 Port Hi-Power 2.4A USB Charger Hub. Coolgear, Inc. Version 1.1 September 2017 Model Number: U2CHGRHUB10

User Manual Entry Line Industrial Gigabit Ethernet High Power 60/95 W PoE Injector

POE084824B. PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. v.1.1 EN* Edition: 7 from

Features and Benefits. Certifications

Party Par. User Manual. Order codes: EQLED015 - Black housing EQLED015B - Polished housing

Support 1 RS-232 or RS-485/422 serial port to 1 10/100Base-T(X) self-adaptive Ethernet interface

User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

Slimline CW & WW Series

Performer 18 HEX. 18 x 12W 6-in-1 colour LEDs (RGBWAUV) User Manual. Order code: LEDJ252B

Features and Benefits. SNMP MIB-II for network management. Certifications

CDP 405 Digital Dimmer Pack

CAN485. Wall Mounting CAN to RS-485 Interface Converter. Support data conversion between 1 CAN port and 1 RS-485 serial port

Features: Example of use

Advanced Power over Ethernet Controllers. Models: TS-5-POE, TS-8-PRO, TS-16-CARRIER. Gigabit PoE Ports. Advanced Switch Management Features

Features: DSFB108 v1.1 DIN rail mounted switch 10-ports DSFB108 with buffer power supply for 8 IP cameras

UV Spectra Batten 12 x 5W UV LEDs

Mid-span 802.3af PoE Injector. Installation Guide KPOE-100

Industrial 8-port unmanaged Gigabit PoE Ethernet switch with 8x10/100/1000Base-T(X) P.S.E., 24VDC power inputs

High-Power Unmanaged PoE Switch with LCD Status Display. Power over Ethernet 802.3at. Innovative LCD Status Display

Alu HEX Par 64. (12 x 12W six-colour LEDs RGBWAUV) User Manual. Order code: ELUM114

ZF LED Zoom Fresnel. User Manual

Video surveillance camera Installation Guide

Gobo Projector XP 80W

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

Crossfire. User Manual. Order code: EQLED061

TECHCONNECT TC2-HDMI14 OWNERS MANUAL

Performer 18 RGBWA MKII

Artistic Licence Price List

Advanced Power over Ethernet Controllers. Datasheet. Tel: +44 (0) Fax: +44 (0)

Advanced Power over Ethernet Controllers. Datasheet. Models: TS-5-POE, TS-8-PRO, TS-16-CARRIER. Gigabit PoE Ports. Intuitive Configuration Interface

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Stride SE2 Series Unmanaged Industrial Ethernet Switches and Media Converters

PF LED Profile. User Manual

ISE2005D Series Unmanaged Industrial Fiber/Ethernet Switch

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

PSBOC PSBOC 27,6V/5,5A/OC

HDMI 8x8 Matrix Switch UHD-4K

5-Port 10/100TX with 4 PoE Injector Industrial Switch

Device Server for the conversion of serial interfaces (RS-232/422/485) to IP.

APT20. User Manual.

LIGHT BRICK - 12 X 3W TRI-COLOUR

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

Entry Line Industrial Gigabit Ethernet Bridging Converter, PoE+ optional 1x 10/100/1000Base-T, 1x 100/1000 SFP

Modular 8-Port Mid-span Power over Ethernet Injector

CLT-302R & CLT-302L CAMERA LINK TRANSLATOR. User s Manual. Document # , Rev 0.2, 7/15/2011

Save installation time and money with PoE and get the most out each PoE connection with PoE passthrough!

APM. User manual & Installation guide. Digital paging microphone.

Industrial and Industrial Hardened Unmanaged non- PoE and PoE switch range

DL-HD2100 Quick Install Guide

8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual

Industrial 10/100/1000BASE-T to 100/1000BASE-X SFP Media Converter

See instructions to download and install the latest version of LinkBoxMB and the user's manual at


KRAMER ELECTRONICS LTD. USER MANUAL MODEL: RC-76R/RC-78R Room Controllers. P/N: Rev 5

ISE2016D Series Unmanaged Industrial Ethernet Switch

INJ-24A Series Quick Installation Guide

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

User's Manual

6 / 8 Port Gigabit Ethernet Switch with PoE+ optional with 2x SFP Slots

LevelOne. User Manual. USB-0301 USB Fast Ethernet Adapter

Vector Beam White. User Manual. Order code: LEDJ265

4TX + 1MMFX Unmanaged Ethernet Switch

Installation instructions Ethernet switch EC / / 2011

CF-POE4 4-Port Gigabit + 2GE Uplink PoE Switch

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

MAINSLINK MAINSLINK. Applications: Switched Live Cable Replacement. Thermostat Cable Replacement

Transcription:

Artistic Licence Mica User Guide Version 1-1

Please read these instructions before using the product. This product has been designed & manufactured for professional use only. It should only be installed by a suitably qualified technician and in accordance with electrical regulations in the country of use. Unless directed in the instructions there are no user serviceable parts inside the outer case of this product. Always disconnect from the power supply when not in use. Any specific IP rating, where appropriate, is given in the instructions. Unless otherwise stated this product is designed for indoor use only. If used outdoors it MUST be installed in an appropriate IP rated cabinet. Do not allow this product to be exposed to rain or moisture. Do not allow liquid to penetrate the product. Please recycle all packaging. Copyright Artistic Licence Engineering Ltd. All rights reserved. Download the user guide by scanning the following QR code: Page 2

Connections Label Type Description 1 Switch User Interface 2 Connection DC Power In 3 Connection Art-Net & PoE 4 Configuration Switch See below Table: Configuration Settings Ref. On Off 1 2 3 Tx: Art-Net Macros Macros Sub-Key 1-8 DMX Channels 1-8 IP Address: DHCP Tx: ArtDMX Channels Macros Sub-Key 101-108 DMX Channels 101-108 IP Address: Static 4 Not Used Not Used 5 Not Used Not Used 6 Not Used Not Used 7 Not Used Not Used 8 Not Used Not Used Mounting Diagram Page 3

Overview Mica is a wall mounted trigger panel designed to provide a user interface for larger systems. It is capable of transmitting either ArtDMX (DMX over Ethernet) or Art-Net Macro trigger packets to controllers such as dvnet, Colour-Tramp, or Multi-Play. Configuration is achieved using the internal DIP switch with options for Packet Type, Channels/Keys used and IP address assignment. Application Diagram Mica Art-Switch PoE4 PSU Art-Net / PoE Art-Lynx O/P Art-Net Macro Art-Net DMX DMX Multi-Play Lighting Controller Terminated Terminated Electrical Connection Mica can be powered either by a 9V DC connection or using PoE on the Ethernet connection. This unit has been designed to be permanently powered due to its low power consumption. DC Power In This option allows the use of a good 9V DC PSU. The connection must be made with the correct polarity. This is indicated on the PCB. PoE Power-over-Ethernet is a method of powering devices on an Ethernet line. The power is supplied usually within the switch. The PoE Switch will check to see if there is a compatible node on the output and if there is it will apply 48V. An example of a PoE Switch is Art-Switch PoE4. Page 4

Ethernet Connection Mica is a fully compliant Ethernet based product and the protocol it uses is Art-Net V1.4. It can be used with all standard Ethernet devices, for example a standard Ethernet Switch. The Ethernet connection is made using a standard RJ45 connector. As with all Ethernet based products there are two cable choices: y Connecting Mica to an Ethernet Switch - A Patch cable must be used. y Connecting Mica to an Art-Net Node - A Cross-Over cable must be used. Configuration For the Art-Net and Art-DMX configuration settings, please refer to page 3. IP Address Mica can be configured to have either a static IP address or one assigned by a DHCP server. Static IP Address If this option is selected Mica will use its default IP address which is in the 2.x.x.x range. The actual address is calculated based on its MAC address value to ensure there are no two devices using the same IP address. The static IP address can be changed by using DMX-Workshop. This will allow the use of any legal IP address and Sub-Net value. DHCP Assigned IP Address If Mica is being used on a dynamically addressed system that uses a DHCP server, it can be configured to have its IP address assigned by the server. Output Mica has the option of sending out two different packets. ArtDMX Packets An ArtDMX packet contains a full universe of DMX data that can be used to trigger a controller. Please see the table below regarding channel use. Dip Switch 1: OFF Button DIP Switch 2 OFF DIP Switch 2 ON 1 DMX Ch 1 @ 255 DMX Ch 101 @ 255 2 DMX Ch 2 @ 255 DMX Ch 102 @ 255 3 DMX Ch 3 @ 255 DMX Ch 103 @ 255 4 DMX Ch 4 @ 255 DMX Ch 104 @ 255 5 DMX Ch 5 @ 255 DMX Ch 105 @ 255 6 DMX Ch 6 @ 255 DMX Ch 106 @ 255 7 DMX Ch 7 @ 255 DMX Ch 107 @ 255 8 DMX Ch 8 @ 255 DMX Ch 108 @ 255 Page 5

Art-Net Macros Art-Net Macros are used specifically for triggering within an Art-Net Network. Each packet is made up of a Key and a Sub-Key to allow for unique triggering messages. Mica uses a Key value of 1. The Sub-Key value can change. Please see the table below for more details. The specification of an Art-Net Macro packet can be found in the Art-Net spec. Dip Switch 1: ON Button DIP Switch 2 OFF DIP Switch 2 ON 1 Key 1 Sub-Key 1 Key 1 Sub-Key 101 2 Key 1 Sub-Key 2 Key 1 Sub-Key 102 3 Key 1 Sub-Key 3 Key 1 Sub-Key 103 4 Key 1 Sub-Key 4 Key 1 Sub-Key 104 5 Key 1 Sub-Key 5 Key 1 Sub-Key 105 6 Key 1 Sub-Key 6 Key 1 Sub-Key 106 7 Key 1 Sub-Key 7 Key 1 Sub-Key 107 8 Key 1 Sub-Key 8 Key 1 Sub-Key 108 Operation When a Front Panel button on Mica is pressed it performs two functions: 1. The LED on the button pressed illuminates 2. The selected packet is sent When this packet is received by a controller it can be used to trigger a response, such as starting a show. Mica Art-Net Macros (1 to 8) Art-Net Macros (101 to 108) DMX (via Art-Net) (Ch: 1 to 8 @ 255) DMX (via Art-Net) (Ch: 101 to 108 @ 255) Page 6

Mica Specification Mechanical y Housing: 2-gang style panel (portrait or landscape) y Material: metal y Overall dimensions: 85mm (H) x 147mm (W) x 41 mm (D) y Weight: 0.25 kg y Mounting: -gang back box (47mm deep) y Country of manufacture: UK Environmental y Operating temperature: 0 C to 40 C y Storage temperature: -10 C to +50 C y Operating relative humidity (max): 80% non-condensing y IP rating: IP20 indoor use only y Certification: CE, FCC, WEEE, RoHS y Warranty: 2-year (return to base) Power & Electrical y Input voltage: 9 VDC y Input connector: 2-pin pluggable screw terminal (1 no.) y Input power (max): 2 W y Duty cycle: 80% @ 25 C y DC input: reverse voltage protection Ethernet y Isolation: 1 kv y PoE: supported Control y Output Protocols: Art-Net macros, ArtDMX triggers Data Connections y RJ45 ethernet (1 no.) User interface y 8 push-buttons with LED indication Configuration y DIP switch (8-way) y Configurable settings include: --Art-Net macro or ArtDMX packet --Sub-Key or DMX channel (1-8 or 101-108) --Static/Dynamic IP addressing Package Contents y Mica y Back box (screws included) y User guide Ordering Info y Product code: Mica Accessories (not included) y PSU-9-1.5-DCJ y Art-Switch PoE4 & PSU-48-1-DR (powers up to 4 units) CE Compliance Mica is CE compliant when installed in a shielded and earthed metal back box Page 7

Warranty All products are covered from date of purchase by a two-year return to base warranty. By return to base, we mean that the customer is responsible for all costs of transport to and from Artistic Licence. Returns will not be accepted without prior authorisation. In order to discuss a request to return goods, please email: Sales@ArtisticLicence.com Compliance All Products manufactured or sold by Artistic Licence Engineering Ltd are fully compliant with the appropriate CE, FCC, and RoHS regulations. Product specific information is available on request. Waste Electrical & Electronic Equipment (WEEE) Artistic Licence is a member of a WEEE compliance scheme and will happily recycle any of our products that you, at your expense, return to us. Artistic Licence Studio 1, Spectrum House 32-34 Gordon House Road London NW5 1LP United Kingdom Customer support and knowledge base: www.artisticlicence.com/support.html Telephone +44 (0) 20 8863 4515 Fax +44 (0) 20 8426 0551 Email: Sales@ArtisticLicence.com Web: www.artisticlicence.com Due to our policy of continuing product improvement specifications are subject to change without notice