Lighting Control System for Indoor Applications LIGHT CONTROLLER L LIGHT CONTROLLER L

Similar documents
Lighting Control System for Indoor Applications LIGHT CONTROLLER LW RADIO-OPERATED VERSION ENOCEAN RADIO-OPERATED CONTROLLER

Intelligent Light Control System for Indoor Applications

Lighting Control System for Indoor Applications EXTENDER / EXTENDER64 EXTENDER / EXTENDER64. To extend the LiCS Indoor System

Intelligent Light Control

Technical Manual. Light Controller L/LW. LiCS Light Controller L/LW EN 02/2014 I

Blu2Light Light Management Installation in Luminaires

COMPACT LED DRIVERS. PrimeLine DALI dimmable & Selectable Current (Dip Switch) PrimeLine DALI DIMMABLE & SELECTABLE CURRENT (DIP SWITCH)

Electrical devices may only be mounted and connected by electrically skilled persons.

Operating Instructions. DALI-Gateway

1 Safety instructions. 2 Device components. 3 Function. IC00P01DAL - DALI gateway. DALI gateway. Operating instructions

KNX DALI Gateway Plus - User Manual

LINEAR LED DRIVERS. PrimeLine DALI dimmable. PrimeLine DALI DIMMABLE , , , , ,

DALI Professional Controller-4. Control unit Operating instructions

LED FlatPanel Gen. 2 DALI

LINEAR LED DRIVERS. ComfortLine NFC. ComfortLine NFC , , ,

Operating and mounting instructions

COMPACT LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , , , , , ,

CC COMPACT DIP SWITCH

COMPACT LED CONVERTERS 48 V

Data sheet. Function description. Benefits

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

LINEAR LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , ,

COMPACT LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , ,

LINEAR LED DRIVERS. ComfortLine Industry Selectable Current (LEDset) ComfortLine INDUSTRY SELECTABLE CURRENT (LEDset) ,

COMPACT LED DRIVERS. ComfortLine Residential. ComfortLine RESIDENTIAL , , ,

Product documentation

Data sheet. Constant current DALI LED control gear 80 W Output power ma Output current Intelligent temperature protection.

Control unit for lux control, MDRC Type: SL/S 50.1, GH Q R0001

LinkRay LED Drivers EasyLine With Selectable Current , Typical Applications

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

COMPACT LED DRIVERS. EasyLine Selectable Current (Output Terminal) EasyLine SELECTABLE CURRENT (OUTPUT TERMINAL) , , ,

As soon as the luminaires are switched off, the built-in relay disconnects the control gear from the mains supply, reducing power loss to 0.5 W.

LC35SE-DA W SELV Dimmable DALI-2 LED driver. 35 W V 0/ Hz. Functional Description. Mains Characteristics

Product and functional description

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

Product and functional description

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

LL1x50-E-DA. 1x50 W Dimmable DALI LED driver. 50 W V 0 / 50 Hz 60 Hz. Functional description. Mains characteristics

Operating instructions

1 Safety instructions. 2 Device components. 3 Function. Control unit 1-10 V, 3-gang. Art.-No.: 2193 REG. Operationsmanual

1 Safety instructions. 2 Device components. 3 Function. Control unit, 1-10 V 3-gang. Order-No. : Operating instructions

Operating instructions I / 2010

IP20 RED. Applications. DALI / 1-10V Version. Trailing Edge / On-off Version. Features. Free smartphone App for set-up and commissioning

Product and function description

OT EASY 60 II. LED control unit Operating instructions

OPTIMISED LUMINAIRE PROTECTION

Operating instructions. Standstill monitor A / / 2011

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

ABB i-bus EIB. Shutter Actuator, 2-fold, 6 A, 230 VAC, MDRC JA/S 2.6.1, GH Q R0111

Operating Instructions VEGAMET 381

PHOENIX CONTACT - 07/2006

PHOENIX CONTACT - 01/2008

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

TRIO-DIODE/12-24DC/2X10/1X20

OPTIMISED LUMINAIRE PROTECTION

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

Electronic Temperature Controller. Instruction Manual Version

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions Evaluation system for flow sensors VS / / 2013

Non-communicating room controllers

OTi DALI 75/ /700 D LT2 UF L

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

LL1x150-CR-DA. 150 W Dimmable DALI-2 LED driver. 150 W V 0 / Hz. Functional Description. Mains Characteristics

ETD-BL-1T-OFF-CC- 10S

Supplementary operating instructions for your air curtain system Controller TMC 500

Figure 1: Device components

WAGO Lighting Management The Lighting Control Solution Stay in Control of Your System

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

LL1x80-CR-DA. 80 W Dimmable DALI-2 LED driver. 80 W V 0 / Hz. Functional Description. Mains Characteristics

Operating instructions AC010S Compact AS-i E-STOP safety module

Installation and User Guide

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

PHOENIX CONTACT Features

Product and functional description

SATEL-LP-AI4. I/O extension module, 4 analog current inputs. Data sheet. 1 Description

Switching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX

Application Manual TOUCH DIM CORRIDOR FUNCTION WIRELESS

Product and functional description

Operating voltage Maximum

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

G5 PDU Installation Guide

Technical information

Assembly and operating instructions DULCOMARIN II, N-Module (Power Supply Module without Relay) DXMaN

QUINT-BUFFER/24DC/24DC/40

Docking station Order no Operation and installation instructions. 1 Safety instructions. 2 Structure of the device.

PHS Series. PowerHUBB Node - Satellite

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Product and functional description

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

RTU500 series Data Sheet Power Supply CP-E 24/2.5

LRI1655, LLC1655 Datasheet ActiLume 1-10V System

MINI-PS AC/10-15DC/8

Dimmers - Clipsal by Schneider Electric

basicdim Wireless Wireless module for basicdim

IF-80x Outdoor Terminal

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

Transcription:

LIGHT CONTROLLER L LIGHT CONTROLLER L The VS Light Controllers are light management systems that were developed to control and regulate light independently of PCs and higher-order bus systems. Communication between the Light Controller and the luminaire is achieved using the standard DALI protocol. The Light Controllers comply with all the parts of standard IEC 62386 currently valid. Within this standard, the number of maximum possible luminaires is defined as 64. The controllers have been designed for mounting to a 35 mm DIN installation rail. The lighting system can be configured completely and easily without a PC or radio control being necessary. Any later modifications to the system can thus be carried out without any problems. The Light Controller L is particularly suitable for controlling systems with different groups: Flexible combination of the system participants in different groups Switching and dimming of the groups using standard keys Activation of a digital timer through a key Requesting scenes using standard keys Constant light regulation of groups/single luminaires Motion detection in different variants, automatic and semiautomatic Stand-by function to minimise loss thanks to the use of an internal cut-off relay contact Use of a password to prevent misuse Light Controller L STAND-ALONE CONTROLLER FOR DALI DEVICES for integration into the distribution board INDIVIDUAL ADDRESSING FLEXIBLE CONFIGURATION without additional tools or PC MAX. 64 ELECTRONIC BALLASTS, MAX. 36 SENSORS AND 6 PUSH BUTTONS

Overview of the LiCS Indoor System Product matrix Light Controller L / LS Light Controller LW / LSW Light Controller S Light Controller XS for integration into the distribution board for integration into the distribution board EnOcean wireless version for independent operation for independent operation MultiSensors High Bay Sensors MultiSensors (motion and brightness) Extender HB Sensors (motion) or brightness (constant light control) Accessories max. 6 buttons (mains voltage-compatible) antenna (magnetic-base or screw-base); max. 6 buttons (mains voltagecompatible); EnOcean wireless modules (max. 16 pcs.) button (mains voltage-compatible) button (mains voltage-compatible) LiCS Controller L_GB 2/6 February, 2014 Functions Light Controller Light Controller Light Controller Light Controller L LS LW LSW S XS Control options single and group group single and group group broadcast broadcast No. of groups max. 16 max. 16 No. of operating devices (DALI-EBs, LiCS-Extender, HB sensors) max. 64 max. 64 max. 64 max. 10 No. of MultiSensors max. 36 max. 36 max. 36 max. 4 Motion detection (automatic and semi-automatic) Constant light control Scene settings Push function (on/off, up and down) Dimming (only up or only down) ON/OFF function Overriding central control Stairwell function (timer) With integrated timer clock Discourage burglaries System analysis software Password protection Minimising standby losses Menu navigation in German, English, French, Italian, Spanish German, English, French, Italian, Spanish Configuration using rotary push key and screen rotary push key and screen dip switch dip switch 2

Light Controller L For installation in a distribution board This light control gear is designed for installation in a distribution board. Technical notes Configuration interface: display screen and rotary push key (on the controller) Ambient temperature t a : 5 to 50 C Push-in terminals with lever opener: 0.5 1.5 mm² Degree of protection: IP20, Protection class: I RFI-suppressed The MultiSensors are connected directly to the DALI bus No. of operating devices (DALI EBs, LiCS Extender, HB sensors): max. 64 pcs. No. of MultiSensors: max. 36 pcs. 126 48,5 90 68 Connections Mains connection: 220 240 V AC, 50 60 Hz, max. power consumption 9 W 1 DALI bus to 3 pairs of terminals: max. current on DALI bus = 200 ma (see the respective data sheet for current consumption of individual components) As a standard DALI bus is not SELV-compliant, the DALI cable must be rated for mains voltage. The DALI bus features reversible electronic overload and short-circuit protection. 6 independently configurable push button inputs: cables must be rated for mains voltage; 220 240 V AC, 50 60 Hz 1 closing relay contact to 2 pairs of terminals (can be reconfigured as an opener): Minimising standby losses 93,2 Functions Automatic and semi-automatic motion detection, constant light control, scene settings, push function, ON/OFF function (also central), stairwell function (timer), system analysis software, password protection, control options (single and/or group) Software languages: German, English, French, Spanish, Italian LightController L Dimensions (LxWxH): 126x90x68 mm, 7hp (horizontal pitches) Weight: 250 g Ref. No.: 186189 LiCS Controller L_GB 3/6 February, 2014 3

General safety information LiCS products may only be installed and commissioned by authorised and fully qualified staff. These instructions must be carefully read before installing and commissioning the system, as this is the only way to ensure safe and correct handling. Before any work is carried out on the equipment, it must be disconnected from the mains. All valid safety and accident-prevention regulations must be observed. The products should never be inexpertly opened as this poses lethal danger due to electrical shock. Repairs may only be undertaken by the manufacturer. On no account may the DALI control line be used to carry mains voltage or any other external voltage as this can destroy individual system components. Light Controller L Installation In a distribution board on a 35-mm mounting rail in acc. with DIN 43880; required installation space: 7 hp (horizontal pitches) (126 mm) The controller must be installed so the display screen is in the upper left corner. Hook the light controller over the upper edge of the rail using the two mounting notches. Then carefully press the controller onto the lower part of the rail until the mounting spring on the controller snaps into place over the rail. If required, use a screwdriver to help you with the spring. Removal To remove the controller from the mounting rail, use a screwdriver to loosen the spring and ease the controller over the rail flange from the bottom. Installation instructions Conductor cross-section for all terminals: 0.5 1.5 mm² for rigid or flexible conductors Cable preparation (see right) To protect the equipment, a 10 A or 16 A, Type B automatic circuit breaker must be fitted. Push button inputs 1 6: cables must be rated for mains voltage; max. cable length = 100 m. As a standard DALI bus is not SELV-compliant, the DALI cable must be rated for mains voltage. A max. of 64 DALI operating devices in aggregate can be connected as well as up to 36 MultiSensors, which in total must not exceed 200 ma. The exact number of components can be found in the manual. The power supply and the DALI line can be laid in a single cable provided the cable does not exceed a maximum length of 100 m, e.g. using 5 x1.5 mm². Three electrically connected DALI outputs make it easier to connect DALI control gear. Please observe the maximum lengths of the DALI bus during installation: 0.5 1.5 mm² 8.5 9.5 1.5 mm² 1 mm² 0.75 mm² 0.5 mm² 6,2 Ω max. 300 m 180 m 130 m 80 m The relay contact is a potential-free closing contact. The current load of the relay contact must not exceed an Ohmic load of I max. = 3 A. When using the standby contact, an additional external power relay should be used. Although models of the Light Controller L/LS and LW/LSW feature an antenna-connection jack (located top right on the front), only the jack on the LW/LSW model is functional. This is where the antenna is connected to enable wireless operation (EnOcean) of the Light Controller LW/LSW. LiCS Controller L_GB 4/6 February, 2014 4

Additional information To ensure faultless wireless operation, an antenna must be connected that is set to the respective frequency. This antenna is not included in the scope of delivery. Please refer to the manual at www.vossloh-schwabe.com/en/home/products/ light-management-systems-for-indoor-applications.html for exact instructions on how to configure the system using the controller. The outputs of different controllers must not be connected with each other. To ensure safe operation of the controller, the maximum ambient temperature must not be exceeded. Circuit diagram of Light Controller L Technical details Light Controller L Light Controller L Ref. No. 186189 Supply voltage 220 240 V AC, 50 60 Hz Power consumption 9 W Ambient temperature t a 5 to 50 C DALI output (da+ ) max. 200 ma current drain No. of operating devices (DALI-EBs, LiCS-Extender, max. 64 pcs. per Controller (expandable with the Extender) HB sensors) No. of MultiSensors max. 36 pcs. RF input Wireless module No. of wireless modules Relay (outputs a1, a2) 250 V, max. 3 A ohmic load Push inputs 1 6 220 240 V AC, 50 60 Hz Degree of protection IP20 Protection class I Weight 250 g CE requirements EMC in acc. with EN 61547, RFI in acc. with EN 55015, Safety in acc. with EN 61347-2-11 LiCS Controller L_GB 5/6 February, 2014 5

Sales information Light Controller L Developed for use in indoor applications, the L Controller in combination with the standard DALI protocol (DIN EN 62386) enables control of dimmable electronic ballasts with a DALI interface. The individually configurable Controller performs all tasks associated with commissioning and managing a modern lighting system. Instead of needing additional equipment, such as a PC plus respective software, the Controller can be operated using the integrated rotary push key and display screen. 6 wired push buttons make the Controller highly flexible and extremely user-friendly, both during installation and commissioning. In addition, huge energy-saving potential can be harnessed by integrating motion, occupancy and brightness data loggers (sensors) powered via the DALI bus into the lighting system. Thanks to the fact that values can be adjusted directly at the Controller, the various data logger (sensor) functions (motion detection and/or brightness control) can be fine-tuned to suit the given need. In addition, the Controller can also be used to define the various motion data logger (sensor) modes (automatic/semi-automatic) and is fitted with a mounting bracket for fixing the unit to a 35 mm installation rail (DIN 43880). The L Light Controller covers 7TE (125 mm) on the installation rail (hat rail). Text for invitations to tender Light Controller L Light controller type: Integration in a distribution board for self-sufficient installation with data loggers (sensors) to deliver the DALI supply voltage for all DALI control gear devices that are connected to the communication interface within a permanently operating lighting system. The integrated display screen and the rotary encoder are used to configure the system. System parameters are saved without an additional prompt and can be changed at will without requiring additional devices. Six individually configurable 230 V inputs are available as control elements for the lighting system. 100 addresses can be allocated using the DALI bus system; a maximum of 64 addresses can be used to individually address standardised DALI control gear devices and a maximum of 36 addresses to clearly allocate data loggers (sensors) that do not feature a standardised protocol. Several addresses can be grouped together a maximum of 16 times. Both operating elements/data loggers (push buttons or sensors) and functions can be allocated to the individual addresses and groups. In this regard, a single data logger (sensor) can be allocated to the same address of a push button to jointly control a luminaire or a luminaire group, to deliver feedback for motion detection and to call up or switch off defined DALI lighting values. Possible functions are manual dimming, call up or switching off of defined DALI lighting values (0 254), call up of up to three defined lighting values (0 254) with an adjustable delay of 10 seconds to 90 minutes. The functions lighting value logger and movement detection of the MultiSensor data logger can also be taken over independently. Parameters are set using just the integrated display screen and the rotary encoder. An integrated potential-free relay contact makes it possible to activate connected control gear via a power relay (NO or NC). Light Controller: DALI master acc. to EN 62386 Software languages: German, English, Spanish, French, Italian (further languages can be integrated) Configuration screen: Monochrome with high-contrast lighting (128x64 pixels) Parameter setting: Rotary encoder Supply voltage: 230 V L, N, PE (± 10%) Communication interface: DALI bus system (9.5 22.5 V) to 3 pairs of terminals Relay contact: Potential-free to 2 pairs of terminals (I max = 3 A Ohmic load) Data logger: MultiSensor type: Surface mounting / Luminaire installation / Ceiling installation MovementSensor type: Surface mounting for high installation heights for movement detection Ambient temperature: 0 C...50 C Dimensions (LxWxH): 126 x 90 x 68 mm Casing material: PC, white Short-circuit protection: Yes Power consumption: 9 W Connection terminals: Push-in terminals, max. 1.5 mm² Protection class: I Degree of protection: IP20 LiCS Controller L_GB 6/6 February, 2014 6